Experimental Study of the Invariance of Pressure Gain with Respect to the Dynamics of Multiple Competing Waves in a Rotating Detonation Combustor

Changes in the overall performance of a rotating detonation combustor with respect to changes in operation mode and wave dynamics arising by operation with fixed inlet/exit geometry but at different combustor, lengths are investigated experimentally. The air inlet, fuel injection, and exit constriction geometry are held constant while only the length of the detonation channel is varied from 71 to 137 mm (which corresponds to about 10 to 20 channel widths). Operation of H2/air over a range of air mass flow rates and equivalence ratios are considered for every chamber length. The number and speed of (primary) detonation and secondary waves are characterized through high-speed pressure measurements in the detonation channel and aft chemiluminescence videos. The number of waves is found to increase with length while detonation wave speed decreases significantly. Particular emphasis is given to characterize a phenomenon that is observed at operation with longer combustor lengths and higher mass flow rates. The phenomenon manifests as a super-cycle behavior with a period equal to many detonation wave rotational periods and is characterized by a periodic and structured ascending/descending sequence of the number, speed, and direction of both (primary) detonation and secondary waves. This phenomenon is likely a manifestation of the system failing in achieving operation with a higher number of detonation waves as length and/or mass flow rate are increased. The performance of the device is quantified in terms of measured thrust and pressure gain (through the use of the equivalent available pressure). Both metrics are essentially found to be invariant with respect to combustor length and most importantly, mode of operation. Surprisingly, even operation with complex wave dynamics arising from transitions between multiple competing wave systems does not appear to alter the overall global performance of the device but rather, it remains defined by the total (capture) air mass flow rate, equivalence ratio, and inlet/outlet areas.

33 ADVANCED PROPULSION SYSTEMS↗

Controlled dehumidification to extract clean water from a multicomponent gaseous mixture of organic contaminants

Rapid expansion of the unconventional oil and gas extraction has increased American energy independence, but also led to increased production of large amounts of contaminated water. Wastewater from the oil and gas industry contains a wide range of contaminants. Injecting such contaminated water into disposal wells or discharging it to the environment jeopardizes freshwater resources. Conventional and membrane-based wastewater treatment techniques are often not effective choices to treat highly contaminated wastewater; however, a suitable way to remove contaminants from wastewater is to selectively separate water in a process analogous to humidification-dehumidification (HDH). Only a few studies have investigated the use of HDH for wastewater treatment. In this study, a novel HDH system is introduced for treating highly contaminated water, such as oil and gas flowback and produced water. In this HDH process, a non-condensable gas, such as air, mixes with wastewater vapor to facilitate the separation of contaminants. As a result, clean water condenses from the multicomponent gaseous mixture while air carries organic contaminants out of the dehumidification section. A laboratory apparatus was constructed and experiments were performed to investigate the HDH process for wastewater treatment and to study the effects of flow dynamics including air flow rate on the composition of treated water. Different contaminants including benzene, toluene, 2-propanol and 2-butoxyethanol were tested. Experimental results showed that the system can be successfully applied for removing volatile and/or toxic organic contaminants from wastewater. A representative multicomponent mixture of fracking wastewater was successfully treated using the experimental setup and clean water with quality of 98.3% was obtained. It was revealed that increasing the air-to-vapor mass ratio improves purity of treated water. Quantitative analysis showed that by increasing the air-to-vapor mass ratio from 0.6 to 5.9, the fraction of separated 2-propanol through the air was improved from 43% to more than 96% of the initial amount. ASPEN software was employed to simulate equilibrium conditions. Finally, experimental results were observed to have lower mass fraction of residual contaminant in the treated water compared to equilibrium state.

42 ENGINEERING↗

Numerical analysis of air dehumidification through electrospray-enhanced vortical flow cyclone separator

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.

42 ENGINEERING↗

Mass flow rate effect on a rotating detonation combustor with an axial air injection

Changing the flow rate of reactants being injected into a rotating detonation combustor (RDC) results in interesting behavior of the system. Prior studies have found that an increase in mass flow rate gradually increases the detonation wave speed before splitting the wave into multiple fronts. Here, the focus of this study is in understanding the physics of such behavior through a combination of experiments and numerical simulations. For this purpose, the axial air inlet-based RDC geometry is used. In the experiments, the wave velocity increased similar to prior studies. Corresponding full-scale simulations show that increase in mass flow rate by increasing pressure of the feed plenums shortens the recovery time of the injectors. This causes a more uniform fuel–air mixture to form prior to the arrival of the detonation wave. As a result, a more ideal detonation is observed, which leads to an increased wave velocity. Details of the detonation structure and variation with mass flow rate are analyzed. The presence and variation of the different deflagration zones in such non-premixed RDCs are also discussed.

42 ENGINEERING↗

Air Dehumidification using Ionic Liquid-Based Fiber Bundle Membrane Contactor

Air dehumidification is essential since excess moisture in the buildings causes discomfort to the occupants, encourages the production of air pathogens such as mold or mildew, and causes corrosion and rotting that degrade building materials. Existing moisture removal processes are mainly focused on condensation and desiccant (liquid or solid) techniques with direct contact between air and desiccant. However, these methods are energy-intensive, or desiccant might be lost or cause corrosion in the process. The main objective of this study is to investigate an ionic liquid-based liquid desiccant absorber based on a membrane fiber bundle. The novel system consists of membrane contactors containing bundles of 10,000 polypropylene fibers. The fiber bundles have 0.3 micron diameter, with ionic liquid flowing inside, and air flowing outside. The fibers provide a high contact area among phases: 1.4 m2 contact surface area in a 0.00015 m3 volume. The ionic liquid as a sorbent stipulates the selectivity for air, prevents the loss of solvent in the operation due to negligible volatility, provides fast diffusion due to low viscosity compared to common ionic liquids, and has high affinity and solubility in water. The dehumidification capacity of the membrane technology was experimentally investigated. The experimental results show that the ionic-liquid based membrane system can effectively remove excess moisture from the air. The novel fiber bundle dehumidification system has a system volume of 0.00798 m3 (7.98 L) and active heat and mass transfer surface area of 8.4 m2. It achieved an average dehumidification of 320 ± 25 W with a volumetric air flowrate of 3.1 m3/min (108 ft3/min).

Turnaoglu, Tugba↗

Adaptive mesh based combustion simulations of direct fuel injection effects in a supersonic cavity flame-holder

Here, we present high-fidelity reacting simulations of a supersonic cavity flame-holder configuration. The focus of this work is on flame stabilization brought about by varying the location of fuel injection in a cavity stabilized supersonic flow of air. Central to our approach is a compressible multi-species reacting flow solver that uses adaptive-mesh-refinement (AMR), enabling the resolution of flame, shock-waves, boundary-layers, and small-scale structures in the computational domain. Our analysis indicates that fuel injection closer to the ramp at the aft end of the cavity allows for greater mixing and lower peak temperatures compared to fuel injection upstream that is closer to the backward facing step of the cavity. This difference is mainly due to greater turbulent fluctuations generated from the shear-layer towards the cavity ramp, thereby enhancing the mixing of fuel and air. A low frequency oscillatory behaviour in heat-release and pressure was also observed for the upstream injection case while a much higher-frequency phenomena was observed in the near-ramp injection case. By identifying the important physical determinants of the combustion processes, this study illustrates a promising pathway to design and optimize direct fuel injection strategies in supersonic cavity flame-holders that can improve flame stability, combustion efficiency, and reduce emissions.

42 ENGINEERING↗

Mapping the intrinsic photocurrent streamlines through micromagnetic heterostructure devices

Photocurrent in quantum materials is often collected at global contacts far away from the initial photoexcitation. This collection process is highly nonlocal. It involves an intricate spatial pattern of photocurrent flow (streamlines) away from its primary photoexcitation that depends sensitively on the configuration of current collecting contacts as well as the spatial nonuniformity and tensor structure of conductivity. Direct imaging to track photocurrent streamlines is challenging. Here, we demonstrate a microscopy method to image photocurrent streamlines through ultrathin heterostructure devices comprising platinum on yttrium iron garnet (YIG). We accomplish this by combining scanning photovoltage microscopy with a uniform rotating magnetic field. Here, local photocurrent is generated through a photo-Nernst type effect with its direction controlled by the external magnetic field. This enables the mapping of photocurrent streamlines in a variety of geometries that include conventional Hall bar-type devices, but also unconventional wing-shaped devices called electrofoils. In these, we find that photocurrent streamlines display contortion, compression, and expansion behavior depending on the shape and angle of attack of the electrofoil devices, much in the same way as tracers in a wind tunnel map the flow of air around an aerodynamic airfoil. This affords a powerful tool to visualize and characterize charge flow in optoelectronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Inlet Area Ratio on Operability of an Axial Air Inlet Rotating Detonation Combustor

This research presents the first results from a new Rotating Detonation Combustor (RDC) design with an axial air inlet and rear-facing angled fuel injection. This design features a variable air inlet that allows for the study of the effect of inlet area ratio on operation and to directly study the coupling between the air plenum and channel of the RDC while minimizing inlet pressure losses. This device maintains the same downstream channel configuration as those previously tested in our laboratory, which includes a 154 mm outer channel diameter and a constant area channel with a width of 7.6 mm. All tests were completed with a downstream hydrogen-air afterburner capable of flashing back in the channel to initiate detonation operation. Initial tests demonstrated successful operation at air mass flow rates from 160 to 770 g/s and equivalence ratios from 0.53 to 1.05 at multiple air inlet to channel area ratios, indicated that sensors installed within the air feed plenum are able to characterize the dynamic characteristics of waves within the detonation channel, and verified that the design goals for this configuration were achieved.

Shepard, Joshua↗

Numerical investigation of mass flow rate effects on multiplicity of detonation waves within a H 2 /Air rotating detonation combustor

This paper presents results from numerical simulations of a non-premixed hydrogen-air rotating detonation combustor with radial injection. The fuel and air mass flow rate are varied in order to hold a unity global equivalence ratio. The calculations show that multiple detonation waves co-exist when the mass flow rate is increased. Conditional statistics of the detonation structure and combustion processes suggest similarities across co-existing waves. Quantification of the injection response to the rotation of a detonation indicates that at higher flow rate the refill time is short enough to allow for a quick and well mixed composition prior to the new front passage. Details of the combustion characteristics are analyzed. Finally, the results elucidate the correlation between initial injection conditions and detonation multiplicity on the overall physics within the combustor.

08 HYDROGEN↗

Particle Handling in Particle-Based Pumped Thermal Energy Storage

A particle-based pumped thermal electricity storage system stores high-temperature heat (~1000 degrees C) in low-cost silica sand and generates power through an efficient power cycle. Central to this system is a counterflow direct-contact gas/particle fluidized-bed heat exchanger, which can significantly improve the heat exchange process due to the large heat transfer surface area of particles. To showcase a lab-scale 10- to 20-kWe heat exchange process with particles heating up to 300 degrees C, a comprehensive hydrodynamic analysis of the fluidization condition inside the heat exchanger was conducted. The heat exchanger was designed to target for heat exchange process of 10-20 kW and accommodate an air mass flow rate of 0.3-0.7 kg/s. The fluidization condition was set to maintain stable bubbling fluidization, thereby maximizing the particle-to-air heat transfer. An air distributor was designed to equally distribute air over the bed, which can avoid defluidized zones in the heat exchanger. Additionally, particle handling systems including L-valves, screw conveyors, and pneumatic conveyors were developed for the prototype heat exchanger, efficiently conveying high-temperature particles at 0.2-0.5 kg/s. This work lays the foundation for scaling up the system and integrating it into larger energy storage applications, demonstrating its potential for efficient, high-temperature thermal energy storage and power generation.

25 ENERGY STORAGE↗

Characterization of local parameters of inclined upward air–water bubbly two-phase flows in a round pipe

The present work seeks to develop a detailed experimental database and characterize the local effects of inclination on horizontal and upward bubbly air–water two-phase flows. Experimental conditions are selected to investigate bubbly flows at a variety of orientations while reducing the influence of flow regime transition. Detailed time-averaged data is collected using state-of-the-art four-sensor conductivity probes for measurements across the flow area for five flow conditions at five inclination orientations in a 25.4 mm inner diameter pipe. Using the newly established database, effects of inclination on bubbly flows are analyzed, as are changes in liquid and gas flow rate at different orientations. The observations include (1) bubble migration and agglomeration at the top pipe wall as orientation changes from vertical to horizontal; (2) reducing the angle from vertical reduces the local gas velocity, and correspondingly reduces the global slip from greater than unity at 90° to less than unity for 60° and lower; (3) changes in the bubble size distribution are primarily at the interface between the bubble cluster and the liquid region of the pipe, not coalescence within the bubble cluster. In conclusion, physical mechanisms for these observations are proposed, and the present trends at different orientations support previous experiments in horizontal two-phase flows.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and experimental validation of direct contact crossflow packed beds condenser used in HDH desalination systems

Humidification and dehumidification (HDH) desalination systems are alternatives to reverse osmosis desalination systems, especially for high salinity waters. A HDH system is essentially equipped with a humidifier (also called as evaporator) for air to pick up vapor from saline water, a dehumidifier (also called as condenser) to produce freshwater, and a heating source. HDH systems based on direct contact packed beds heat exchangers have remarkably lower costs than traditional HDH systems due to their inexpensive materials and simple configurations. This paper specifically focuses on direct contact crossflow packed beds condensers, in which cooling water vertically drips through the packed beds, directly contacting the horizontal air-vapor flow. A two-dimensional mathematical model that solves for the enthalpy values of the working fluids is proposed in this paper, and the PDEs are solved using finite differences. To validate the model, an experimental condenser was built and tested. Water temperatures inside the test section at twenty-nine locations were measured, as well as the air vapor temperatures of five locations at the outlet. The measured water and air-vapor temperatures agree with the simulation results with less than 10 % error in most of the compared domain.

42 ENGINEERING↗

Impact of Lateral Alignment for Cooling Airflow during Heavy-Truck Platooning

A truck platooning system was tested using two heavy-duty tractor-trailer trucks on a closed test track to investigate the thermal control/heat rejection system sensitivity to intentional lateral offsets over a range of intervehicle spacings. Previous studies have shown the following vehicle can experience elevated temperatures and reduced airflow through the cooling package as a result of close-formation platooning. Four anemometers positioned across the grille of the following trucks as well as aligned and multiple offset positions are used to evaluate the sensitivity of the impact. Straight sections of the track are isolated for the most accurate airflow impact measurements and to be most representative of on-highway driving. An intentional lateral offset in truck platooning is considered as a controls approach to mitigate reduced cooling efficacy at close following scenarios where the highest platoon savings are achieved. The truck platooning system was tested at four gap distances from 9 to 23 meters and the following truck was either aligned with the lead or offset with a 25% width (0.65 m) or 50% width (1.3 m) lateral distance. The experimental results clearly show that offset driving is effective at bringing cooling airflow from 56% with an aligned platoon back up to 75%-80% with minimal impact to fuel savings. In addition, the offset driving can also reduce the trailing truck’s engine coolant temperature by 2°C and the corresponding underhood temperature rise by 10°C. The test outcomes indicate a plausible controls strategy to mitigate reduced cooling flow during hot-weather truck platooning while still enabling the highest-energy-saving, close-following scenarios.

27 ARPA - Advanced Research Projects Agency-Energy↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

Numerical simulation of evaporating wavy falling liquid films in laminar gas streams

Numerical simulations are performed to investigate the interfacial heat and mass transfer from evaporating wavy falling liquid films in interaction with laminar gas streams. The OpenFOAM solver has been used to conduct the simulations where the liquid-gas interface is resolved using the Volume of Fluid method of solving for three phases, i.e., liquid, vapor, and air. The configuration considered is a falling liquid (water) film on a heated vertical plate with a confined laminar moist air (gas) flow that is either (a) co-current or (b) counter-current to the downward liquid flow. The evaporation at the liquid-gas interface is driven by the interfacial gradient of the vapor mass fraction. Interfacial waves are triggered using a monochromatic forcing disturbance that leads to sinusoidal or solitary waves forming at the liquid-gas interface under respective forcing frequencies. Further, the numerical model is validated with the available experimental data. The results show nearly a 15% enhancement in time-averaged Sherwood number (Sh) due to film waviness (sinusoidal or solitary) at the lower volumetric gas flow rate, Q g = +50 (co-current) and Q g = -50 (counter-current). This enhancement in the Sh for both the waves further increases by 11% with Q g = +800 and 196% with Q g = -800. A closer examination of the mass transfer process over a wave demonstrates that with Q g = +50, the concentration of the gas side streamlines at the trough locations of the wave leads to higher values of Sh at these locations. However, with Q g = +800, although the overall Sh increases, vortices appear at the wave trough locations, leading to a corresponding decrease in the local Sh values. Correlations are proposed for predicting Sh under co-current and counter-current gas flow effects.

36 MATERIALS SCIENCE↗