Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

155 records · Page 9

Lowering post‐construction yield assessment uncertainty through better wind plant power curves

Abstract Many operational analyses of wind power plants require a statistical relationship, which can be called the wind plant power curve, to be developed between wind plant energy production and concurrent atmospheric variables. Currently, a univariate linear regression at monthly resolution is the industry standard for post‐construction yield assessments. Here, we evaluate the benefits in augmenting this conventional approach by testing alternative regressions performed with multiple inputs, at a finer time resolution, and using nonlinear machine‐learning algorithms. We utilize the National Renewable Energy Laboratory's open‐source software package OpenOA to assess wind plant power curves for 10 wind plants. When a univariate generalized additive model at daily or hourly resolution is used, regression uncertainty is reduced, in absolute terms, by up to 1.0 % and 1.2 % (corresponding to a −59 % and −80 % relative change), respectively, compared to a univariate linear regression at monthly resolution; also, a more accurate assessment of the mean long‐term wind plant production is achieved. Additional input variables also reduce the regression uncertainty: when temperature is added as an input to the conventional monthly linear regression, the operational analysis uncertainty connected to regression is reduced, in absolute terms, by up to 0.5 % (−43 % relative change) for wind power plants with strong seasonal variability. Adding input variables to the machine‐learning model at daily resolution can further reduce regression uncertainty, with up to a −10 % relative change. Based on these results, we conclude that a multivariate nonlinear regression at daily or hourly resolution should be recommended for assessing wind plant power curves.

17 WIND ENERGY↗

Ionic conductivity of Bi{sub 2}Ni{sub x}V{sub 1−x}O{sub 5.5−3x/2} (0.1 ≤ x ≤ 0.2) oxides prepared by a low temperature sol-gel route

Solid oxides fuel cells (SOFCs) is one technology that could contribute toward future sustainable energy. One of the most important components of an SOFC is the electrolyte, which must have high ionic conductivity. Cation substitution of vanadium in Bi{sub 4}V{sub 2}O{sub 11} yields a family of fast oxide ion conducting solids known collectively as the BIMEVOXes (bismuth metal vanadium oxide), which have the potential to be applied as electrolytes in SOFCs. The purpose of this work is to study the effect of Ni concentration, when used as a dopant, on the ionic conductivity of Bi{sub 2}Ni{sub x}V{sub 1−x}O{sub 5.5−3x/2} (BINIVOX) oxides (0.1 ≤ x ≤ 0.2) when prepared by a sol gel method. The gels were calcined at 600 °C for 24 h to produce pure BINIVOX. These oxides were found to exhibit the γ-phase structure with tetragonal symmetry in space group I4/mmm. Ionic conductivity of BINIVOX at 300 °C were 6.9 × 10{sup −3} S cm{sup −1}, 1.2 × 10{sup −3} S cm{sup −1}, and 8.2 × 10{sup −4} S cm{sup −1}, for x = 0.1; 0.15; and 0.2; respectively; and at 600 °C were 1.1 × 10{sup −1} S cm{sup −1}, 5.3 × 10{sup −2} S cm{sup −1}, and 2.8 ×10{sup −2} S cm{sup −1}, for x = 0.1; 0.15; and 0.2; respectively.

36 MATERIALS SCIENCE↗

TidGen LCOE Workbooks

Workbooks showing Annualized Energy Production, Cost Breakdown Structure, Levelized Cost of Electricity for DOE Refernce Tidal Project 1) Baseline TidGen Power System 2) TidGen Power System with the application of Advanced Controls 3) Advanced TidGen Power System with several enhancements These files are provided as a zipped set. Files are linked together and must be viewed in the same folder.

16 TIDAL AND WAVE POWER↗

LCOE Baseline for RME Surge WEC Device

This submission includes all the data to support an LCOE baseline assessment for the Resolute Marine Energy (RME) Surge WEC device

16 TIDAL AND WAVE POWER↗

Modular RivGen LCOE Content Model

The Modular RivGen LCOE Content Model contains estimates of levelized cost of energy (LCOE) for three array configurations operating in a theoretical river environment. The LCOE is distinguished by the CapEx, OpEx, and annual energy production and capture for each river environment.

16 TIDAL AND WAVE POWER↗

Tidal Currents in San Juan Archipelago, Washington

Re-analyzed acoustic Doppler current profiler (ADCP) data originally collected by NOAA CO-OPS (Center for Operational Oceanographic Products and Services) and equivalent point data from Pacific Northwest National Laboratory's FVCOM (Finite Volume Community Ocean Model) model of the region. Data are processed to products describing characteristics of tidal currents relevant to tidal turbines, as well as power output estimates for a notional turbine deployed from a surface platform or from the seabed at each location. These data underpin the results presented in their associated paper - see below.

16 TIDAL AND WAVE POWER↗

Wind Plant Performance Prediction Benchmark Phase 1 (Technical Report)

Financial risk resulting from the uncertainty associated with developing, owning, and operating wind power plants remains a barrier to reducing the levelized cost of energy (LCOE). On average, modern wind power plants in the U.S. underperform their expected annual energy output by 3.5-4.5% , with many underperforming by over 10%. To compensate for this uncertainty, investors require a larger return on investment (ROI) and apply "knock-down" factors that mask much of the underlying sources of uncertainty. Wind energy projects thus have reduced access to low-cost capital. Furthermore, operating wind plants often take a simple approach to estimating operations & maintenance (O&M) costs (e.g. straight-line estimates based on similar plants), which can eat into profits. To overcome these issues, the wind industry must improve the models they use for estimating wind plant performance and operations. An industry consortium (IC) requested that the National Renewable Energy Laboratory (NREL) lead a Department of Energy (DOE) working group to benchmark the accuracy of wind power plant energy predictions against real operational data. The IC was also motivated by DOE and NREL's potential to characterize systematic energy underperformance, identify sources of uncertainty, and explore root causes. The Wind Plant Performance Prediction (WP3) project was created out of this request, and this report represents the successful completion of Phase 1 of the WP3 project. During the project, wind plant owners provided both pre-construction and operational data to NREL. The pre-construction data was provided to wind resource assessment (WRA) consultants so they could conduct energy yield assessments (EYA). NREL took all of the completed EYAs, along with the operational data, and conducted an operational assessment to benchmark the EYA results against actual operational data. Given the large amounts of sensitive data required for this effort, as well as historical opposition to sharing data within industry, successful completion of Phase 1 represents an unprecedented milestone for industry data sharing. To improve the accuracy and confidence of pre-construction EYAs, wind plant owners and investors need better, more certain, energy yield predictions. The WP3 Benchmark Project is an industry-driven response to this reality. For the first time, industry has taken the important step of working together at scale, sharing valuable operational data with DOE and NREL in order to investigate the sources of bias and uncertainty in these energy estimates. This IC provides wind plant preconstruction and operational data to NREL in an organized and documented fashion and provides guidance and feedback as needed. The IC also provides introspection of the design of experiment, key metrics of success, data challenges, analysis best practices, and quality of results.

17 WIND ENERGY↗

Risk-Based Methodology for the Determination of Hall Thruster Performance Specifications

This work adapts manufacturing and metrology industry standards to create a risk-based approach for the determination of electric propulsion performance specifications. The developed process is applied to 208 total thrust measurements acquired using three different NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Unit (TDU) 12.5-kW Hall thrusters in three different test facilities in order to generate thrust specifications at the 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW operating conditions. These thrust specifications are used to perform a set of sample acceptance tests to illustrate the importance of adding additional conservatism using a parameter known of the Test Accuracy Ratio in order to control the risk to the thruster producer and consumer from false rejection and acceptance of thruster units.

HERMeS↗

Risk-based Methodology for the Determination of Hall Thruster Performance Specifications

This work adapts manufacturing and metrology industry standards to create a risk-based approach for the determination of electric propulsion performance specifications. The developed process is applied to 208 total thrust measurements acquired using three different NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Unit (TDU) 12.5-kW Hall thrusters in three different test facilities in order to generate thrust specifications at the 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW operating conditions. These thrust specifications are used to perform a set of sample acceptance tests to illustrate the importance of adding additional conservatism using a parameter known of the Test Accuracy Ratio in order to control the risk to the thruster producer and consumer from false rejection and acceptance of thruster units.

HERMeS↗