Electron-radiation effects on the ac and dc electrical properties and unpaired electron densities of three aerospace polymers

The effects of gigarad-level total absorbed doses from 1-MeV electrons on the post-irradiation alternating-current (ac) and direct-current (dc) electrical properties and the unpaired electron densities have been studied for Kapton, Ultem, and Mylar. The unpaired electron densities (determined from electron paramagnetic resonance spectroscopy) and the dc electrical conductivities of the irradiated materials were monitored as functions of time following the exposures to determine their decay characteristics at room temperature. The elevated-temperature ac electrical dissipations of the Ultem and Mylar were affected by the radiation. The dc conductivity of the Kapton increased by five orders of magnitude, while the dc conductivities of the Ultem and Mylar increased by less than an order of magnitude, due to the radiation. The observed radiation-generated changes in the ac electrical dissipations are explained in terms of known radiation-generated changes in the molecular structures of the three materials. A preliminary model relating the dc electrical conductivity and the unpaired electron density in the Kapton is proposed.

Long, Sheila Ann T.↗

An electrochemical study of corrosion protection by primer-topcoat systems on 4130 steel with ac impedance and dc methods

To investigate metal surface corrosion and the breakdown of metal protective coatings, the ac impedance method is applied to six systems of primer coated and primer topcoated 4130 steel. Two primers were used: a zinc-rich epoxy primer and a red lead oxide epoxy primer. The epoxy-polyamine topcoat was used in four of the systems. The EG and G-PARC Model 368 ac impedance measurement system, along with dc measurements with the same system using the polarization resistance method, were used to monitor changing properties of coated 4230 steel disks immersed in 3.5 percent NaCl solutions buffered at pH 5.4 over periods of 40 to 60 days. The corrosion system can be represented by an electronic analog called an equivalent circuit consisting of resistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for the resistors and capacitors, that can be assigned in the equivalent circuit following a least-squares analysis of the data, describe changes that occur on the corroding metal surface and in the protective coatings. Two equivalent circuits have been determined that predict the correct Bode phase and magnitude of the experimental sample at different immersion times. The dc corrosion current density data are related to equivalent circuit element parameters. Methods for determining corrosion rate with ac impedance parameters are verified by the dc method.

Mendrek, M. J.↗

Development of a computer algorithm for the analysis of variable-frequency AC drives: Case studies included

The development of computer software for performance prediction and analysis of voltage-fed, variable-frequency AC drives for space power applications is discussed. The AC drives discussed include the pulse width modulated inverter (PWMI), a six-step inverter and the pulse density modulated inverter (PDMI), each individually connected to a wound-rotor induction motor. Various d-q transformation models of the induction motor are incorporated for user-selection of the most applicable model for the intended purpose. Simulation results of selected AC drives correlate satisfactorily with published results. Future additions to the algorithm are indicated. These improvements should enhance the applicability of the computer program to the design and analysis of space power systems.

Kankam, M. David↗

Development of software to improve AC power quality on large spacecraft

To insure the reliability of a 20 kHz, AC power system on spacecraft, it is essential to analyze its behavior under many adverse operating conditions. Some of these conditions include overloads, short circuits, switching surges, and harmonic distortions. Harmonic distortions can cause malfunctions in equipment that the power system is supplying, and during extreme distortions such as voltage resonance, it can cause equipment and insulation failures due to the extreme peak voltages. HARMFLO, a power flow computer program, which was capable of analyzing harmonic conditions on three phase, balanced, 60 Hz, AC power systems, was modified to analyze single phase, 20 kHz, AC power systems. Since almost all of the equipment used on spacecraft power systems is electrically different from equipment used on terrestrial power systems, it was also necessary to develop mathematical models for the equipment to be used on the spacecraft. The results are that (1) the harmonic power now has a model of a single phase, voltage controlled, full wave rectifier; and (2) HARMFLO was ported to the SUN workstation platform.

Kraft, L. Alan↗

Electromechanical systems with transient high power response operating from a resonant ac link

The combination of an inherently robust asynchronous (induction) electrical machine with the rapid control of energy provided by a high frequency resonant ac link enables the efficient management of higher power levels with greater versatility. This could have a variety of applications from launch vehicles to all-electric automobiles. These types of systems utilize a machine which is operated by independent control of both the voltage and frequency. This is made possible by using an indirect field-oriented control method which allows instantaneous torque control all four operating quadrants. Incorporating the ac link allows the converter in these systems to switch at the zero crossing of every half cycle of the ac waveform. This zero loss switching of the link allows rapid energy variations to be achieved without the usual frequency proportional switching loss. Several field-oriented control systems were developed under contract to NASA.

Burrows, Linda M.↗

Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

Hull, Gary↗

Max Launch Abort System (MLAS) Pad Abort Test Vehicle (PATV) II Attitude Control System (ACS) Integration and Pressurization Subsystem Dynamic Random Vibration Analysis

In order to mitigate catastrophic failures on future generation space vehicles, engineers at the National Aeronautics and Space Administration have begun to integrate a novel crew abort systems that could pull a crew module away in case of an emergency at the launch pad or during ascent. The Max Launch Abort System (MLAS) is a recent test vehicle that was designed as an alternative to the baseline Orion Launch Abort System (LAS) to demonstrate the performance of a "tower-less" LAS configuration under abort conditions. The MLAS II test vehicle will execute a propulsive coast stabilization maneuver during abort to control the vehicles trajectory and thrust. To accomplish this, the spacecraft will integrate an Attitude Control System (ACS) with eight hypergolic monomethyl hydrazine liquid propulsion engines that are capable of operating in a quick pulsing mode. Two main elements of the ACS include a propellant distribution subsystem and a pressurization subsystem to regulate the flow of pressurized gas to the propellant tanks and the engines. The CAD assembly of the Attitude Control System (ACS) was configured and integrated into the Launch Abort Vehicle (LAV) design. A dynamic random vibration analysis was conducted on the Main Propulsion System (MPS) helium pressurization panels to assess the response of the panel and its components under increased gravitational acceleration loads during flight. The results indicated that the panels fundamental and natural frequencies were farther from the maximum Acceleration Spectral Density (ASD) vibrations which were in the range of 150-300 Hz. These values will direct how the components will be packaged in the vehicle to reduce the effects high gravitational loads.

Ekrami, Yasamin↗

Study of the Dependence on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in the AC bias configuration. For x-ray photons at 6keV the AC biased pixel shows a best energy resolution of 3.7eV, which is about a factor of 2 worse than the energy resolution observed in identical DC-biased pixels. To better understand the reasons of this discrepancy, we investigated the detector performance as a function of temperature, bias working point and applied magnetic field. A strong periodic dependence of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recent weak-link behaviour observed inTES microcalorimeters.

Bandler, Simon↗

Enhancement of the AC RPA

The overall goal of this research project is to improve the response and sensitivity of the AC Retarding Potential Analyzer (RPA). The AC RPA can accurately measure the flux, energy, and energy distribution of charged particles in a space environment. The enhancement of the sensor derives from changes that increase sensitivity of flux measurements through reduction of the baseline noise. The enhanced AC RPA sensor allows diagnosis of required charge particle beams necessary for tests of materials, instruments and subsystems, for future exploration missions.

Israel, Mordecai Ben↗

Dual magnetic phase material rings for AC electric machines

An AC electric machine that includes a dual magnetic phase material ring is disclosed. The AC electric machine includes a stator assembly and a rotor assembly positioned within the stator assembly and configured to rotate relative thereto, the rotor assembly comprising a rotor core including a stack of rotor laminations that collectively form the rotor core, the rotor core including a plurality of rotor poles separated by gaps therebetween. The AC electric machine also includes a dual magnetic phase material ring positioned about the stack of rotor laminations, the dual magnetic phase material ring comprising a first ring portion comprising a magnetic portion and a second ring portion comprising a non-magnetic portion.

42 ENGINEERING↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiterminal Inverse AC Josephson Effect

When a Josephson junction is exposed to microwave radiation, it undergoes the inverse AC Josephson effect–the phase of the junction locks to the drive frequency. As a result, the I–V curves of the junction acquire “Shapiro steps” of quantized voltage. If the junction has three or more superconducting contacts, coupling between different pairs of terminals must be taken into account and the state of the junction evolves in a phase space of higher dimensionality. Here, we study the multiterminal inverse AC Josephson effect in a graphene sample with three superconducting terminals. We observe robust fractional Shapiro steps and correlated switching events, which can only be explained by considering the device as a completely connected Josephson network. We successfully simulate the observed behaviors using a modified two-dimensional RCSJ model. Our results suggest that multiterminal Josephson junctions are a playground to study highly connected nonlinear networks with novel topologies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic ac susceptibility of superconducting Ta films for quantum computing

Recently, breakthroughs were reported in the long coherence time (>0.5 ms) transmon qubit using tantalum films (Ta). Identifying the loss mechanism in Ta films will help further improve the performance of Ta-based superconducting qubits. We report a study of superconducting properties in two sets of Ta films grown on c-cut and a-cut sapphires respectively using contact transport and noncontact magnetic ac susceptibility measurements. Although the resistive transition appears to be similar in both films, we found strikingly different responses in their complex magnetic susceptibilities χ' + iχ'$^{'}$ .χ'$^{'}$ in the c-cut films exhibits a sharp peak at superconducting transition Tc and becomes featureless below Tc indicating a strongly coupled superconducting state. In contrast, χ'$^{'}$ \ in the a-cut films exhibits a broad peak near Tc and a second peak appears below Tc, indicating granular superconductivity behavior. This second peak χ'$^{'}$ in is associated with the hysteresis loss at weak-link-type grain boundaries, which is believed to be a leading source of decoherence in the a-cut Ta films. The derived magnetic loss tangent in the a-cut films is about one order of magnitude higher than in the c-cut films. This study demonstrates that ac susceptibility is an excellent probe for characterizing bulk superconducting properties of the constituent superconducting materials used in qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative Trade-Off in Distributed Secondary Control for Autonomous AC Microgrids

In this paper, we propose to quantify the trade-off between voltage regulation and reactive power sharing in autonomous AC microgrids with distributed secondary control. It is known that voltage regulation and reactive power sharing in droop-controlled autonomous AC microgrids are two conflicting control objectives that present a natural trade-off between voltage regulation towards the voltage magnitude reference and reactive power sharing accuracy. This trade-off is commonly shown qualitatively without sufficient quantification. In this work, to quantify the trade-off between the two objectives, we focus on distributed secondary control and utilize regression and polynomial surface fitting to identify the requisite parameter area to satisfy the predefined error bands for voltage magnitude regulation and reactive power sharing. Extensive case studies are presented to validate the proposed method.

autonomous AC microgrids↗

A High-Efficiency Isolated PFC AC-DC Topology with Reduced Number of Semiconductor Devices

A new three-level isolated ac-dc power factor correction (PFC) topology with a minimum number of semiconductor devices is the focus of this paper. This topology provides a high input power factor (PF), soft-switching, and higher efficiency than existing isolated ac-dc converters. Furthermore, the proposed circuit has lower voltage rating requirements for the secondary side devices, which leads to a lower total cost and minimizes total converter losses. This article presents a theoretical analysis describing the complete characterization of this new topology, and experimental results on a 1-kW prototype showing high PF and efficiency throughout the operating range.

42 ENGINEERING↗

Hysteresis Reduction in Tunneling Magnetoresistive Sensor With AC Modulation Magnetic Field

A simple and practical AC modulation method to reduce the hysteresis in tunneling magnetoresistive sensor is demonstrated. It is shown that with a suitable AC modulation magnetic field that is applied along the sensing direction of TMR sensor, the hysteresis in the sensor can be reduced to a negligible level. And depending on the amplitude of the modulation field, the sensitivity and the dynamic range of the TMR sensor can be tuned to meet practical requirements in specific applications. Here, the influence of the modulation on the noise of TMR sensor is also studied.

42 ENGINEERING↗

A PCB-Embedded 1.2 kV SiC MOSFET Half-Bridge Package for a 22 kW AC–DC Converter

This article presents the design and analysis of a double-side-cooled printed circuit board (PCB) embedded silicon carbide (SiC) MOSFET half-bridge package with low loop inductances and an integrated gate driver. The 1.2 kV SiC MOSFET dies used in the half-bridge package are embedded in the PCB using AT&S's patented technique. The dies are cooled and electrically connected to traces in the PCB through copper-filled microvias. The design methodology accounts for both electrical and thermal performance, limiting the power-loop inductance to 2.3 nH and the maximum package temperature to less than the 175 °C limit. The integration of the gate drive circuitry allows for a high power density and 2.2 nH gate-loop inductances. At 0.12 K/W, the measured junction-to-case thermal resistance with double-sided cooling is 57% lower than that of a TO-247 package. Under similar operating conditions, the PCB-embedded half-bridge package also achieves a 5.6 times lower voltage overshoot and a 0.5% higher peak efficiency than a TO-247-based half-bridge. This article reports the first demonstration of PCB-embedded 1.2 kV SiC MOSFET packages in buck, boost, and ac–dc converters. Furthermore, the prototype three-phase ac–dc converter for an electric vehicle on-board charger is composed of six PCB-embedded half-bridge packages and achieves an efficiency of 98.2% and a power density of 182 W/in 3 .

42 ENGINEERING↗

Applications of Lifted Nonlinear Cuts to Convex Relaxations of the AC Power Flow Equations

Here, we demonstrate that valid inequalities, or lifted nonlinear cuts (LNC), can be projected to tighten the Second Order Cone (SOC), Convex DistFlow (CDF), and Network Flow (NF) relaxations of the AC Optimal Power Flow (AC-OPF) problem. We conduct experiments on 38 cases from the PGLib-OPF library, showing that the LNC strengthen the SOC and CDF relaxations in 100% of the test cases, with average and maximum differences in the optimality gaps of 6.2% and 17.5% respectively. The NF relaxation is strengthened in 46.2% of test cases, with average and maximum differences in the optimality gaps of 1.3% and 17.3% respectively. We also study the trade-off between relaxation quality and solve time, demonstrating that the strengthened CDF relaxation outperforms the strengthened SOC formulation in terms of runtime and number of iterations needed, while the strengthened NF formulation is the most scalable with the lowest relaxation quality improvement due to these LNC.

24 POWER TRANSMISSION AND DISTRIBUTION↗