At least 163 records · Page 9

High voltage series resonant inverter ion engine screen supply

A high-voltage, high-power LC series resonant inverter using SCRs has been developed for an Ion Engine Power Processor. The inverter operates within 200-400Vdc with a maximum output power of 2.5kW. The inverter control logic, the screen supply electrical and mechanical characteristics, the efficiency and losses in power components, regulation on the dual feedback principle, the SCR waveforms and the component weight are analyzed. Efficiency of 90.5% and weight density of 4.1kg/kW are obtained.

Biess, J. J.↗

Low cost composite materials for wind energy conversion systems

A winding process utilizing a low-cost E-glass fabric called transverse-filament tape for low-cost production of wind turbine generators (WTG) is described. The process can be carried out continuously at high speed to produce large one-piece parts with tapered wall thicknesses on a tapered mandrel. It is being used to manufacture blades for the NASA/DOE 200-ft-diameter MOD-1 WTG and Rockwell/DOE 40-kW small wind energy conversion system (SWECS).

Weingart, O.↗

High power density dc-to-dc converters for aerospace applications

Three dc-to-dc converter topologies aimed at high-power high-frequency applications are introduced. Major system parasitics, namely, the leakage inductance of the transformer and the device output capacitance are efficiently utilized. Of the three circuits, the single-phase and three-phase versions of the dual active bridge topology demonstrate minimal stresses, better utilization of the transformer, bidirectional, and buck-boost modes of operation. All circuits operate at a constant switching frequency, thus simplifying design of the reactive elements. The power transfer characteristics and soft-switching regions on the Vout-Iout plane are identified. Two coaxial transformers with different cross-sections were built for a rating of 50 kVA. Based on the single-phase dual active bridge topology, a 50 kW, 50 kHz converter operating at an input voltage of 200 Vdc and an output voltage of 1600 Vdc was fabricated. Characteristics of current-fed output make the dual active bridge topologies amenable to paralleling and hence extension to megawatt power levels. Projections to a 1 MW system operating from a 500 Vdc input, at an output voltage of 10 kVdc and a switching frequency of 50 kHz, using MOS-controlled thyristors, coaxially wound transformers operating at three times the present current density with cooling, and multilayer ceramic capacitors, suggests an overall power density of 0.075 to 0.08 kg/kW and an overall efficiency of 96 percent.

Divan, Deepakraj M.↗

Stagnation Point Heat Transfer with Gas Injection Cooling

The present paper deals with an experimental study of the stagnation-point heat transfer to a cooled copper surface with gas injection under subsonic conditions. Test were made with a probe that combined a steady-state water-cooled calorimeter that allows the capability to study convective blockage and to perform heat transfer measurements in presence of gas injection in the stagnation region. The copper probe was pierced by 52 holes, representing 2.4% of the total probe surface. The 1.2 MW high enthalpy plasma wind tunnel was operated at anode powers between 130 and 230 kW and a static pressures from 35 hPa up to 200 hPa. Air, carbon dioxide and argon were injected in the mass flow range 0-0.4 g/s in the boundary layer developed around the 50 mm diameter probe. The measured stagnation-point heat transfer rates are reported and discussed.

Vancrayenest, B.↗

Effects of an Internally-Mounted Cathode on Hall Thruster Plume Properties

The effects of cathode position on the plume properties of an 8 kW BHT-8000 Busek Hall thruster are discussed. Experiments were conducted at the Jet Propulsion Laboratory (JPL) in a vacuum chamber suitable for the development and qualification of high-power Hall thrusters. Multi-mode Hall thruster operation was demonstrated at operating conditions ranging from 200-500 V discharge voltage, 10-40 A discharge current, and 2-8 kW discharge power. Reductions in plume divergence and increased near-field plume symmetries were found to result from the use of an internally-mounted cathode instead of the traditional externally-mounted configuration. High-current hollow cathodes developed at JPL utilizing lanthanum hexaboride (LaB6) emitters were also demonstrated. Discharge currents up to 100 A were achieved with the cathode operating alone and up to 40 A during operation with the Hall thruster. LaB6 cathodes were investigated because of their potential to reduce overall system cost and risk due to less stringent xenon purity and handling requirements.

electric propulsion↗

Effects of an internally-mounted cathode on hall thruster plume properties

The effects of cathode position on the plume properties of an 8 kW BHT-8000 Busek Hall thruster are discussed. Experiments were conducted at the Jet Propulsion Laboratory (JPL) in a vacuum chamber suitable for the development and qualification of high-power Hall thrusters. Multi-mode Hall thruster operation was demonstrated at operating conditions ranging from 200-500 V discharge voltage, 10-40 A discharge current, and 2-8 kW discharge power. Reductions in plume divergence and increased near-field plume symmetries were found to result from the use of an internally-mounted cathode instead of the traditional externally-mounted configuration. High-current hollow cathodes developed at JPL utilizing lanthanum hexaboride (LaB6) emitters were also demonstrated. Discharge currents up to 100 A were achieved with the cathode operating alone and up to 40 A during operation with the Hall thruster. LaB6 cathodes were investigated because of their potential to reduce overall system cost and risk due to less stringent xenon purity and handling requirements.

Fitzgerald, Dennis J.↗

200 Deg C Demonstration Transformer Operates Efficiently at 50 kHz

A compact, high temperature demonstration transformer was constructed, using a moly permalloy powder core and Teflon -insulated copper wire. At 50 kHz and 200 C, this 1:2 ratio transformer is capable of 98 percent efficiency when operating at a specific power of 6.1 kW/kg at 4 kW. This roughly 7 cm diameter transformer has a mass of 0.65 kg. Although Teflon is unstable above 200 C, about the same electrical performance was seen at 250 C. A plot of winding loss versus frequency illustrates the need to control these losses at high frequency.

Niedra, Janis M.↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10’s of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with 7 kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5 kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

insulation resistance↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation: Preprint

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10's of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with $7$\,kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5\,kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Tapering-enhanced high-efficiency THz waveguide oscillator

Using a waveguide in a THz FEL has been shown to maximize the coupling and enable efficient extraction of relativistic electron beam energy from a single passage through a tapered helical undulator. An oscillator configuration can further boost energy extraction above the single-pass limits and open the door toward very high average power THz sources. Embedding the undulator in an oscillator cavity is particularly useful in combination with high repetition rate electron sources, even if at reduced peak brightness, since recycling a fraction of the radiation as an intense seed can compensate for lower single-pass gain. In this paper, we investigate the efficiency scaling of a tapering-enhanced waveguide oscillator, showcasing its capability for frequency-tuning operation and high-efficiency operation at different wavelengths. Using a thermionic-driven beamline equipped with compression elements, numerical start-to-end simulation results indicate a 16% efficiency at 200 GHz and a 2.1% efficiency at 1.5 THz, resulting in kW-level average power out-coupled in radiation pulses with few hundred μ J energy and tens of MW peak power. Published by the American Physical Society 2024

Yang, Y. N. (ORCID:0009000849540151)↗

High power density dc/dc converter: Component selection and design

Further work pertaining to design considerations for the new high power, high frequency dc/dc converters is discussed. The goal of the project is the development of high power, high power density dc/dc converters at power levels in the multi-kilowatt to megawatt range for aerospace applications. The prototype converter is rated for 50 kW at a switching frequency of 50 kHz, with an input voltage of 200 Vdc and an output of 2000 Vdc. The overall power density must be in the vicinity of 0.2 to 0.3 kg/kW.

Divan, Deepakraj M.↗

Performance evaluation of the Russian SPT-100 thruster at NASA LeRC

Performance measurements of a Russian flight-model SPT-100 thruster were obtained as part of a comprehensive program to evaluate engineering issues pertinent to integration with Western spacecraft. Power processing was provided by a US Government developed laboratory power conditioner. When received the thruster had been subjected to only a few hours of acceptance testing by the manufacturer. Accumulated operating time during this study totalled 148 h and included operation of both cathodes. Cathode flow fraction was controlled both manually and using the flow splitter contained within the supplied xenon flow controller. Data were obtained at current levels ranging from 3 A to 5 A and thruster voltages ranging from 200 V to 300 V. Testing centered on the design power of 1.35 kW with a discharge current of 4.5 A. The effects of facility pressure on thruster operation were examined by varying the pressure via injection of xenon into the vacuum chamber. The facility pressure had a significant effect on thruster performance and stability at the conditions tested. Periods of current instabilities were noted throughout the testing period and became more frequent as testing progressed. Performance during periods of stability agreed with previous data obtained in Russian laboratories.

Sankovic, John M.↗

High-Efficiency Hall Thruster Discharge Power Converter

Busek Company, Inc., is designing, building, and testing a new printed circuit board converter. The new converter consists of two series or parallel boards (slices) intended to power a high-voltage Hall accelerator (HiVHAC) thruster or other similarly sized electric propulsion devices. The converter accepts 80- to 160-V input and generates 200- to 700-V isolated output while delivering continually adjustable 300-W to 3.5-kW power. Busek built and demonstrated one board that achieved nearly 94 percent efficiency the first time it was turned on, with projected efficiency exceeding 97 percent following timing software optimization. The board has a projected specific mass of 1.2 kg/kW, achieved through high-frequency switching. In Phase II, Busek optimized to exceed 97 percent efficiency and built a second prototype in a form factor more appropriate for flight. This converter then was integrated with a set of upgraded existing boards for powering magnets and the cathode. The program culminated with integrating the entire power processing unit and testing it on a Busek thruster and on NASA's HiVHAC thruster.

Jaquish, Thomas↗

Test for Reconditioning RA Waste with Simulated Bitumen and Concrete in a 1,2 MW Plasma Test Facility - 20092

The operation and maintenance of nuclear power plants, the non nuclear fuel cycle, etc generate low-level radioactive waste which, along with the historical radioactive waste from past nuclear activities, needs to be treated and stored, awaiting final disposal. Plasma technology offers a very effective way of treating this waste with a high volume reduction factor (VRF), free from organics, liquids and moisture, and meets without a doubt the acceptance criteria for safe storage and disposal. By means of a plasma beam of approximately 5000 deg. C, the inorganic materials are melted into a glassy slag, containing most of the radioactive isotopes while the organic material is gasified, oxidized and purified in an off-gas cleaning system. First the paper describes the new full-scale Plasma Melting Facility (PMF) at the Kozloduy Nuclear Power Plant in Bulgaria which was taken in nuclear operation In May 2018. The plant has a capacity of 250 tons per year and the maximum contact dose rates of the incoming waste is 2 mSv/h. Different mixtures of radioactive waste packed in 200 l drums were successfully treated resulting in a glassy slag free from liquids and organic material with an important volume reduction factor (VRF). The Project was co-financed through a grant by Kozloduy International Decommissioning fund (KIDSF) administrated by the EBRD through Bulgarian national funding. Plasma is a suitable technology for treatment of problematic waste or even reconditioning waste so Belgoprocess was contracted to do plasma tests with simulated conditioned waste types. One can do tests on a laboratory scale on smaller samples and torch capacities of e.g. 50 kW but Belgoprocess wanted to do more realistic and reliable tests. So Belgoprocess contracted Phoenix Solutions Co who has a full-scope test facility equipped with a 1200 kW plasma torch for full-scope treatment of simulated conditioned waste. For a first confidential contract simulated 200 l (55 gallon) bitumen drums were treated. The drums contained different pucks of compacted waste such as rags, used filters, granulates, etc. The pucks were stacked in the 200 l drums and subsequently embedded with bitumen. A total of 6 drums were treated in the plasma facility. For a second contract simulated homogeneous 200 l (55 gallon) concrete drums with on the one hand concentrates and on the other hand spent resins were selected. A total of 6 drums with concrete and spent resins were treated and melted in the plasma testing facility. The paper describe the test facility, volume reduction factor (VRF) of different waste streams and most important parameters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Static and Turn-on Switching Characteristics of 4H-Silicon Carbide SITs to 200 deg C

Test results are presented for normally-off 4H-SiC Static Induction Transistors (SITs) intended for power switching and are among the first normally-off such devices realized in SiC. At zero gate bias, the gate p-n junction depletion layers extend far enough into the conduction channel to cut off the channel. Application of forward gate bias narrows the depletion regions, opening up the channel to conduction by majority carriers. In the present devices, narrow vertical channels get pinched by depletion regions from opposite sides. Since the material is SiC, the devices are usable at temperatures above 150 C. Static curve and pulse mode switching observations were done at selected temperatures up to 200 C on a device with average static characteristics from a batch of similar devices. Gate and drain currents were limited to about 400 mA and 3.5 A, respectively. The drain voltage was limited to roughly 300 V, which is conservative for this 600 V rated device. At 23 C, 1 kW, or even more, could be pulse mode switched in 65 ns (10 to 90 percent) into a 100 load. But at 200 C, the switching capability is greatly reduced in large part by the excessive gate current required. Severe collapse of the saturated drain-to-source current was observed at 200 C. The relation of this property to channel mobility is reviewed.

Niedra, Janis M.↗

Ultra-low-mass flexible planar solar arrays using 50-micron-thick solar cells

A conceptual design study has been completed which has shown the feasibility of ultra-low-mass planar solar arrays with specific power of 200 watts/kilogram. The beginning of life (BOL) power output of the array designs would be 10 kW at 1 astronomical unit (AU) and a 55C deg operating temperature. Two designs were studied: a retractable rollout design and a non-retractable fold-out. The designs employed a flexible low-mass blanket and low-mass structures. The blanket utilized 2 x 2 cm high-efficiency (13.5% at 28C deg AM0), ultra-thin (50 micron), silicon solar cells protected by thin (75 micron) plastic encapsulants. The structural design utilized the 'V'-stiffened approach which allows a lower mass boom to be used. In conjunction with the conceptual design, modules using the thin cells and plastic encapsulant were designed and fabricated.

Costogue, E. N.↗