Three-Phase Power Factor Controller

Three-Phase Power-Factor Controller develops a control signal for each motor winding. As motor loading decreases, rms value of applied voltage is decreased by feedback-control circuit. Power consumption is therefore lower than in unregulated operation. Controller employs phase detector for each of three phases of delta-connected induction motor. Phase-difference sum is basis for control.

Nola, F. J.↗

Alternator control for battery charging

In accordance with an aspect of the present disclosure, an electrical system for an automotive vehicle has an electrical generating machine and a battery. A set point voltage, which sets an output voltage of the electrical generating machine, is set by an electronic control unit (ECU). The ECU selects one of a plurality of control modes for controlling the alternator based on an operating state of the vehicle as determined from vehicle operating parameters. The ECU selects a range for the set point voltage based on the selected control mode and then sets the set point voltage within the range based on feedback parameters for that control mode. In an aspect, the control modes include a trickle charge mode and battery charge current is the feedback parameter and the ECU controls the set point voltage within the range to maintain a predetermined battery charge current.

25 ENERGY STORAGE↗

Electron tunneling infrared sensor module with integrated control circuitry

In an integrated electron tunneling sensor, an automatic tunneling control circuit varies a high voltage bias applied to the sensor deflection electrode in response to changes in sensor output to maintain the proper gap between the sensor tip and membrane. The control circuit ensures stable tunneling activity in the presence of large signals and other disturbances to the sensor. Output signals from the module may be derived from the amplified sensor output. The integrated sensor module is particularly well adapted for use in blood glucose measurement and monitoring system.

Boyadzhyan-Sevak, Vardkes V.↗

Pressure-controlled magnetism in 2D molecular layers

Abstract Long-range magnetic ordering of two-dimensional crystals can be sensitive to interlayer coupling, enabling the effective control of interlayer magnetism towards voltage switching, spin filtering and transistor applications. With the discovery of two-dimensional atomically thin magnets, a good platform provides us to manipulate interlayer magnetism for the control of magnetic orders. However, a less-known family of two-dimensional magnets possesses a bottom-up assembled molecular lattice and metal-to-ligand intermolecular contacts, which lead to a combination of large magnetic anisotropy and spin-delocalization. Here, we report the pressure-controlled interlayer magnetic coupling of molecular layered compounds via chromium-pyrazine coordination. Room-temperature long-range magnetic ordering exhibits pressure tuning with a coercivity coefficient up to 4 kOe/GPa, while pressure-controlled interlayer magnetism also presents a strong dependence on alkali metal stoichiometry and composition. Two-dimensional molecular interlayers provide a pathway towards pressure-controlled peculiar magnetism through charge redistribution and structural transformation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Droop Compensation for the High Voltage Converter Modulators at the Spallation Neutron Source.

The Spallation Neutron Source (SNS) has been in operation since 2006 and routinely operates at 1 MW of beam power. At 1 MW, the High Voltage Converter Modulators (HVCMs) are delivering 8-11 MW pulsed power to the Klystrons for up to 1185 us at 60 Hz. The pulsed output of the modulator has a substantial voltage droop operating in open-loop mode. Achieving 1.4 MW operations require an increase in the output pulse width of the HVCM, resulting in loss of LLRF control margin due to modulator voltage reduction at the end of the pulse. Initially, the HVCM was designed with a pulse width modulation scheme for droop compensation but early operations at full duty revealed this technique unreliable. Increasing the output voltage of the modulator would likely compromise system reliability. This paper proposes the use of alternate modulation schemes to address the voltage droop. The effect of frequency modulation and phase modulation on voltage droop is studied. Experimental results will also be presented.

43 PARTICLE ACCELERATORS↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

Hierarchical Distributed Voltage Regulation in Networked Autonomous Grids

We propose a novel algorithm to solve optimal power flow (OPF) that aims at dispatching controllable distributed energy resources (DERs) for voltage regulation at minimum cost. The proposed algorithm features unprecedented scalability to large distribution networks by utilizing an information structure based on networked autonomous grids (AGs). Specifically, each AG is a subtree of a large distribution network that has a tree topology. The topology and line parameters of each AG are known only to a regional coordinator (RC) that is responsible for communicating with and dispatching the DERs within this AG. The reduced network, where each AG is treated as a node, is managed by a central coordinator (CC), which knows the topology and line parameters of the reduced network only and communicates with all the RCs. We jointly explore this information structure and the structure of the linearized distribution power flow (LinDistFlow) model to derive a hierarchical, distributed implementation of the primal-dual gradient algorithm that solves the OPF. The proposed implementation significantly reduces the computation burden compared to the centrally coordinated implementation of the primal-dual algorithm. Numerical results on a 4,521-node test feeder show that the proposed hierarchical distributed algorithm can achieve an improvement of more than tenfold in the speed of convergence compared to the centrally coordinated primal-dual algorithm.

Zhou, Xinyang↗

Hierarchical Distributed Voltage Regulation in Networked Autonomous Grids

We propose a novel algorithm to solve optimal power flow (OPF) that aims at dispatching controllable distributed energy resources (DERs) for voltage regulation at minimum cost. The proposed algorithm features unprecedented scalability to large distribution networks by utilizing an information structure based on networked autonomous grids (AGs). Specifically, each AG is a subtree of a large distribution network that has a tree topology. The topology and line parameters of each AG are known only to a regional coordinator (RC) that is responsible for communicating with and dispatching the DERs within this AG. The reduced network, where each AG is treated as a node, is managed by a central coordinator (CC), which knows the topology and line parameters of the reduced network only and communicates with all the RCs. We jointly explore this information structure and the structure of the linearized distribution power flow (LinDistFlow) model to derive a hierarchical, distributed implementation of the primal-dual gradient algorithm that solves the OPF. The proposed implementation significantly reduces the computation burden compared to the centrally coordinated implementation of the primal-dual algorithm. Numerical results on a 4,521-node test feeder show that the proposed hierarchical distributed algorithm can achieve an improvement of more than tenfold in the speed of convergence compared to the centrally coordinated primal-dual algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accurate Consensus-based Distributed Averaging with Variable Time Delay in Support of Distributed Secondary Control Algorithms

We report that distributed secondary control has been widely used in hierarchical control structures, where multiple distributed generators (DGs) need to coordinate to regulate system voltage and frequency. In these systems, consensus algorithms determine the average of a group of dynamic states (e.g. voltages measured by a group of DGs). To be useful, consensus algorithms must be computationally efficient, stable and accurate. In practice, numerous practical implementation challenges significantly affect the consensus equilibrium. In this paper, we quantify the accuracy deviations of the distributed average observer algorithms proposed in the literature to demonstrate the problems with the state-of-the-art distributed averaging techniques. A novel approach is proposed that achieves accurate average tracking in the presence of time-varying communication delays among agents. In our implementation, time synchronization of all distributed controllers is enabled by a novel software platform, called Resilient Information Architecture Platform for the Smart Grid (RIAPS). The proposed distributed average observer is implemented on hardware controllers and its effectiveness is validated in a controller hardware-in-the-loop testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Scheduling of Energy Storage Systems for Real-time Voltage Regulation in Unbalanced LV Networks with High PV Penetration

The ever-growing higher penetration of distributed energy resources (DERs) in low-voltage (LV) distribution systems brings both opportunities and challenges to voltage support and regulation. This paper proposes a deep reinforcement learning (DRL)-based scheduling scheme of energy storage systems (ESSs) to mitigate system voltage deviations in unbalanced LV distribution networks. The ESS-based voltage regulation problem is formulated as a multi-stage quadratic stochastic program, with the objective of minimizing the expected total daily voltage regulation cost while satisfying operational constraints. While existing voltage regulation methods are mostly focused on onetime- step control, this paper explores a day-horizon systemwide voltage regulation problem. In other words, the size of action and state spaces are extremely high-dimensional and need to be delicately handled. Furthermore, in order to overcome the difficulty of modeling uncertainties and develop a realtime solution, a learn-to-schedule feedback control framework is proposed by adapting the problem to a model-free DRL setting. The proposed algorithm is tested on a customized 6-bus system and a modified IEEE 34-bus system. Simulation results validate the effectiveness and near-optimality of voltage regulation by ESS in comparison with a deterministic quadratic program solution.

Wang, Shengyi↗

Three-phase power factor controller with induced EMF sensing

A power factor controller for an ac induction motor is provided which is of the type comprising thyristor switches connected in series with the motor, phase detectors for sensing the motor current and voltage and providing an output proportional to the phase difference between the motor voltage and current, and a control circuit, responsive to the output of the phase detector and to a power factor command signal, for controlling switching of the thyristor. The invention involves sensing the induced emf produced by the motor during the time interval when the thyristor is off and for producing a corresponding feedback signal for controlling switching of the thyristor. The sensed emf is also used to enhance soft starting of the motor.

Nola, F. J.↗

Single‐Domain Multiferroic Array‐Addressable Terfenol‐D (SMArT) Micromagnets for Programmable Single‐Cell Capture and Release

Abstract Programming magnetic fields with microscale control can enable automation at the scale of single cells ≈10 µm. Most magnetic materials provide a consistent magnetic field over time but the direction or field strength at the microscale is not easily modulated. However, magnetostrictive materials, when coupled with ferroelectric material (i.e., strain‐mediated multiferroics), can undergo magnetization reorientation due to voltage‐induced strain, promising refined control of magnetization at the micrometer‐scale. This work demonstrates the largest single‐domain microstructures (20 µm) of Terfenol‐D (Tb 0.3 Dy 0.7 Fe 1.92 ), a material that has the highest magnetostrictive strain of any known soft magnetoelastic material. These Terfenol‐D microstructures enable controlled localization of magnetic beads with sub‐micrometer precision. Magnetically labeled cells are captured by the field gradients generated from the single‐domain microstructures without an external magnetic field. The magnetic state on these microstructures is switched through voltage‐induced strain, as a result of the strain‐mediated converse magnetoelectric effect, to release individual cells using a multiferroic approach. These electronically addressable micromagnets pave the way for parallelized multiferroics‐based single‐cell sorting under digital control for biotechnology applications.

Khojah, Reem↗

Improving Primary Frequency Response to Support Networked Microgrid Operations

Individual microgrids have proven their ability to provide uninterrupted power to critical end-use load during severe events. Building on the performance of individual microgrids during extreme events, there has been an increasing interest in the operations of network microgrids. By networking microgrids during extreme events, it is possible to share resources, increase the duration for which they can operate islanded, and increase the resiliency of critical end-use loads. While there are benefits to networking the operations of resiliency-based microgrids, the switching operations that they require introduce transients which can result in a loss of dynamic stability. The issue of dynamic stability is especially acute in microgrids with high penetrations of inverter-connected generation, and a correspondingly low system inertia. While the low-inertia of these microgrids can be increased by over-sizing the rotating generators, the increased capital and operating costs can become a barrier to deployment. This work will present a method of augmenting primary frequency controls to support the switching transients necessary for the operation of networked microgrids, without the need to over-size rotating machines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Distributed Voltage Regulation in Networked Autonomous Grids: Preprint

We propose a novel algorithm to solve optimal power flow (OPF) that aims at dispatching controllable distributed energy resources (DERs) for voltage regulation at minimum cost. The proposed algorithm features unprecedented scalability to large distribution networks by utilizing an information structure based on networked autonomous grids (AGs). Specifically, each AG is a subtree of a large distribution network that has a tree topology. The topology and line parameters of each AG are known only to a regional coordinator (RC) that is responsible for communicating with and dispatching the DERs within this AG. The reduced network, where each AG is treated as a node, is managed by a central coordinator (CC), which knows the topology and line parameters of the reduced network only and communicates with all the RCs. We jointly explore this information structure and the structure of the linearized distribution power flow (LinDistFlow) model to derive a hierarchical, distributed implementation of the primal-dual gradient algorithm that solves OPF. The proposed implementation significantly reduces the computation burden compared to the centrally coordinated implementation of the primal-dual algorithm. Numerical results on a 4,521-node test feeder show that the proposed hierarchical distributed algorithm can achieve more than 10-fold improvement in the speed of convergence compared to the centrally coordinated primal-dual algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast rise breakdown in dielectric filled air gap for surge protection

Electric discharge across an air gap can be self-healing, providing a unique capability for repetitive, fast, high-voltage/current switching applications through arc conduction. Furthermore, incorporating dielectric granules in the air gap stimulates gas ionization, which lowers the breakdown voltage and narrows breakdown voltage distribution, thereby enabling engineered surge protection from multiple lightning strikes on aerospace vehicles and sensitive solid-state electronics in critical systems. This study investigates the effect of the permittivity of dielectric granules, gap filling, surface roughness, and metal work function on fast-rising, high-voltage breakdowns. In addition to the air gap width, these factors play important roles in gas ionization, field concentration, and initiation of electrical discharge and arcing. Therefore, they could potentially be used to control and narrow operational breakdown voltages for practical applications. Additionally, a modified Langevin–Debye model is developed to correlate the breakdown voltage and the permittivity of the dielectric filler. These investigations identify and highlight key underpinning mechanisms governing the gas discharge behavior across a dielectric filled air gap during voltage surge events.

42 ENGINEERING↗

Terahertz rectification in ring-shaped quantum barriers

Tunneling is the most fundamental quantum mechanical phenomenon with wide-ranging applications. Matter waves such as electrons in solids can tunnel through a one-dimensional potential barrier, e.g. an insulating layer sandwiched between conductors. A general approach to control tunneling currents is to apply voltage across the barrier. Here, we form closed loops of tunneling barriers exposed to external optical control to manipulate ultrafast tunneling electrons. Eddy currents induced by incoming electromagnetic pulses project upon the ring, spatiotemporally changing the local potential. The total tunneling current which is determined by the sum of contributions from all the parts along the perimeter is critically dependent upon the symmetry of the loop and the polarization of the incident fields, enabling full-wave rectification of terahertz pulses. By introducing global geometry and local operation to current-driven circuitry, our work provides a novel platform for ultrafast optoelectronics, macroscopic quantum phenomena, energy harvesting, and multi-functional quantum devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical mechanism for coercivity tunability in the electrically controlled FePt perpendicular films with small grain size

This article reports property manipulations and related dynamical evolution in electromigration controlled FePt perpendicular films. Through altering voltage and treatment time of the power supply applied on the films, electronic momentum was fleetly controlled to manipulate the kinetic energy of Fe and Pt atoms based on momentum exchanges. The electromigration control behavior was proven to cause steerable ordering degree and grain growth in the films without thermal treatment. Processed FePt films with small grain size, high magnetocrystalline anisotropy, and controllable coercivity can be easily obtained. The results provide a novel method for tuning magnetic properties of other L1{sub 0} structured films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗