Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visualization techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Volumetric visualization of 3D data

In recent years, there has been a rapid growth in the ability to obtain detailed data on large complex structures in three dimensions. This development occurred first in the medical field, with CAT (computer aided tomography) scans and now magnetic resonance imaging, and in seismological exploration. With the advances in supercomputing and computational fluid dynamics, and in experimental techniques in fluid dynamics, there is now the ability to produce similar large data fields representing 3D structures and phenomena in these disciplines. These developments have produced a situation in which currently there is access to data which is too complex to be understood using the tools available for data reduction and presentation. Researchers in these areas are becoming limited by their ability to visualize and comprehend the 3D systems they are measuring and simulating.

Russell, Gregory↗

Display formatting techniques for improving situation awareness in the aircraft cockpit

Possible modifications of primary flight instruments for attitude control and navigation were examined including a display perspective, frames of reference, and the incorporation of directional color to enhance visual momentum. A low-fidelity fixed-wing flight simulation was evaluated. It is concluded that situation awareness measured by flight performance and recovery from disorientation events, was best maintained with the planar outside-in display, whereas color coding improved the performance on the planar inside-out display.

Andre, Anthony D.↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Imaging transient solidification behavior

Solidification processing offers the first opportunity to control microstructure, properties, and performance in metallic alloy components. Until recently, microstructural evaluations were limited to post-solidification characterization by destructive methods. We review the development of time-resolved, in situimaging techniques capable of capturing solid-liquid interfacial evolution in metallic alloys with high spatial and temporal resolution underdiverse solidification conditions relevant for applications ranging from conventional directional solidification, crystal growth, and casting,to welding and additive manufacturing. These experiments enable direct visualization of transient behaviors that would otherwise remain unknown, uniquely providinginsights into the physics that impact microstructure and defect development and strategies for microstructuralcontrol and defect mitigation. Understanding microstructural evolution and the characteristics that form under various solidification conditions is essential for the development of multiscale, experimentallyinformed predictive modeling. This is highlightedby solidification simulations that utilize in situmeasurements of solidification dynamics from state-of-the-art experimental techniques.

36 MATERIALS SCIENCE↗

Quantification of manganese for ChemCam Mars and laboratory spectra using a multivariate model

In this work, we report a new calibration model for manganese using the laser-induced breakdown spectroscopy instrument that is part of the ChemCam instrument suite onboard the NASA Curiosity rover. The model has been trained using an expanded set of 523 manganese-bearing rock, mineral, metal ore, and synthetic standards. The optimal calibration model uses the Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO) multivariate techniques, with a novel “double blending” technique. We determined the detection limit for manganese is 82 ppm using a method blank procedure and is possibly as low as 27 ppm based on visual inspection of the spectra. Based on a representative test set consisting of measurements on 93 standards, the double blended multivariate model shows a Root Mean Squared Error of Prediction (RMSEP) accuracy of 1.39 wt% MnO for the full blended model. Employing a local RMSEP estimate where the model performance is evaluated based on nearby test samples, the accuracy is 0.03 wt% at the quantification limit (0.05 wt% MnO), 0.4 wt% accuracy at 1.0 wt% MnO, and 4.4 wt% accuracy at 100 wt% MnO. Precision is estimated using the standard deviation of the test set measurements, and is ±0.01 wt% MnO at the quantification limit, ±0.09 wt% MnO at 1.0 wt% MnO, and ± 2.1 wt% MnO at 100 wt% MnO (all 1 standard deviation). This new calibration is important for understanding the variation of manganese in the bedrock with the Curiosity rover on Mars, which provides insight into past redox conditions on Mars.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development and use of metal-based probes for X-ray fluorescence microscopy

Abstract X-ray fluorescence microscopy (XFM) has become a widely used technique for imaging the concentration and distribution of metal ions in cells and tissues. Recent advances in synchrotron sources, optics, and detectors have improved the spatial resolution of the technique to <10 nm with attogram detection sensitivity. However, to make XFM most beneficial for bioimaging—especially at the nanoscale—the metal ion distribution must be visualized within the subcellular context of the cell. Over the years, a number of approaches have been taken to develop X-ray-sensitive tags that permit the visualization of specific organelles or proteins using XFM. In this review, we examine the types of X-ray fluorophore used, including nanomaterials and metal ions, and the approaches used to incorporate the metal into their target binding site via antibodies, genetically encoded metal-binding peptides, affinity labeling, or cell-specific peptides. We evaluate their advantages and disadvantages, review the scientific findings, and discuss the needs for future development.

36 MATERIALS SCIENCE↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Armstrong #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Marcellus Formation. The core is from a vertical well (Armstrong #1) drilled in Taylor County, West Virginia by the Petroleum Development Corporation (7,545 to 7,783.4 ft). Core was provided by Phillip Dinterman, West Virginia Geologic and Economical Survey (WVGES) and Tim Carr and Keithan Martin, West Virginia University (WVU). The primary impetus of this work is a collaboration between NETL, WVGES, and WVU to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale formations. As part of this effort, bulk scans of core were obtained from the Armstrong #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/armstrong-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Wabash No.1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize Mt. Simon core from the Wabash CarbonSAFE project, Wabash No. 1 well. The primary impetus of the work in this report is a collaboration between NETL Research and Innovation Center and the Illinois State Geological Survey at the Prairie Research Institute, University of Illinois Urbana-Champaign in Champaign, Illinois. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wabash-no-1-well. The Wabash No. 1 well was drilled as part of a U.S. Department of Energy (DOE) funded Carbon Storage Assurance Facility Enterprise field project to assess the feasibility of developing a commercial-scale geological storage complex at the Wabash Valley Resources Integrated Gasification Combined Cycle plant near Terre Haute, Indiana. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in fine-grained structures; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy-related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Patterson #5-25 Well in Western Kansas

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize core from the Patterson Field site. This core came from a vertical well (Patterson #5-25 well) that was obtained as part of the U.S. Department of Energy (DOE) sponsored Integrated Midcontinental Stacked Carbon Storage Hub. The primary impetus of this work is a collaboration between NETL and the Kansas Geological Survey to characterize core from the Patterson Field site. The 625 ft of whole core from the Atoka Formation to Precambrian Basement was characterized at NETL. As part of this effort, bulk scans of core were obtained. This report, and the associated scans, provide detailed datasets not typically made publicly available for carbon capture utilization and storage analysis. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/patterson-5-25-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL are useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Block adaptive rate controlled image data compression

A block adaptive rate controlled (BARC) image data compression algorithm is described. It is noted that in the algorithm's principal rate controlled mode, image lines can be coded at selected rates by combining practical universal noiseless coding techniques with block adaptive adjustments in linear quantization. Compression of any source data at chosen rates of 3.0 bits/sample and above can be expected to yield visual image quality with imperceptible degradation. Exact reconstruction will be obtained if the one-dimensional difference entropy is below the selected compression rate. It is noted that the compressor can also be operated as a floating rate noiseless coder by simply not altering the input data quantization. Here, the universal noiseless coder ensures that the code rate is always close to the entropy. Application of BARC image data compression to the Galileo orbiter mission of Jupiter is considered.

Rice, R. F.↗

Investigation of several aspects of LANDSAT 4/5 data quality

A technique under development uses a zoom transfer scope to register the photograph of the target with digitally enlarged photographic hardcopy of the TM data using a visual fit to the area surrounding the target. The first attempt using the Sacramento Scene (44/33) of February 1, 1983 indicated that relief displacement in the aerial photography would cause large errors. A second attempt is in progress using the aero-triangulated scene centers which have no relief displacement. Being calculated points, the scene centers have somewhat larger absolute errors in geolocation, approximately 3 meters instead of 1.5 meters. The average TM effective instantaneous field of view (EIFOV) calculated from modulation transfer functions (MTFs) is 52.7 m. This is smaller than the 55 and 65 m EIFOVs reported earlier using noisy MTFs but larger than the EIFOVs from the San Mateo Bridge analysis which ranged from 44.5 to 50.9 m and averaged 47.6 m for the same TM scene.

Wrigley, R. C.↗

The dynamics of orbital maneuvering: Design and evaluation of a visual display aid for human controllers

An interactive proximity operations planning system, which allows on-site planning of fuel-efficient, multi-burn maneuvers in a potential multi-spacecraft environment was developed and tested. Though this display system most directly assists planning by providing visual feedback to aid visualization of the trajectories and constraints, its most significant features include an inverse dynamics algorithm that removes control nonlinearities facing the operator and a trajectory planning technique that reduces the order of control and creates, through a geometric spread-sheet the illusion of an inertially stable environment. This synthetic environment provides the user with control of relevant static and dynamic properties of way-points during small orbital changes allowing independent solutions to the normally coupled problems of orbital maneuvering. An experiment was carried out in which experienced operators were required to plan a trajectory to retrieve an object accidently separated from a dual-keel space station. The time required to plan these maneuvers was found to be predicted by the direction of the insertion thrust and did not depend on the point of separation from the space station.

Ellis, Stephen R.↗

Applied high-speed imaging for the icing research program at NASA Lewis Research Center

The Icing Research Tunnel at NASA Lewis Research Center provides scientists a scaled, controlled environment to simulate natural icing events. The closed-loop, low speed, refrigerated wind tunnel offers the experimental capability to test for icing certification requirements, analytical model validation and calibration techniques, cloud physics instrumentation refinement, advanced ice protection systems, and rotorcraft icing methodology development. The test procedures for these objectives all require a high degree of visual documentation, both in real-time data acquisition and post-test image processing. Information is provided to scientific, technical, and industrial imaging specialists as well as to research personnel about the high-speed and conventional imaging systems will be on the recent ice protection technology program. Various imaging examples for some of the tests are presented. Additional imaging examples are available from the NASA Lewis Research Center's Photographic and Printing Branch.

Slater, Howard↗

Applied high-speed imaging for the icing research program at NASA Lewis Research Center

The Icing Research Tunnel at NASA Lewis Research Center provides scientists a scaled, controlled environment to simulate natural icing events. The closed-loop, low speed, refrigerated wind tunnel offers the experimental capability to test for icing certification requirements, analytical model validation and calibration techniques, cloud physics instrumentation refinement, advanced ice protection systems, and rotorcraft icing methodology development. The test procedures for these objectives all require a high degree of visual documentation, both in real-time data acquisition and post-test image processing. Information is provided to scientific, technical, and industrial imaging specialists as well as to research personnel about the high-speed and conventional imaging systems will be on the recent ice protection technology program. Various imaging examples for some of the tests are presented. Additional imaging examples are available from the NASA Lewis Research Center's Photographic and Printing Branch.

Slater, Howard↗

Quality metrics for sensor images

Methods are needed for evaluating the quality of augmented visual displays (AVID). Computational quality metrics will help summarize, interpolate, and extrapolate the results of human performance tests with displays. The FLM Vision group at NASA Ames has been developing computational models of visual processing and using them to develop computational metrics for similar problems. For example, display modeling systems use metrics for comparing proposed displays, halftoning optimizing methods use metrics to evaluate the difference between the halftone and the original, and image compression methods minimize the predicted visibility of compression artifacts. The visual discrimination models take as input two arbitrary images A and B and compute an estimate of the probability that a human observer will report that A is different from B. If A is an image that one desires to display and B is the actual displayed image, such an estimate can be regarded as an image quality metric reflecting how well B approximates A. There are additional complexities associated with the problem of evaluating the quality of radar and IR enhanced displays for AVID tasks. One important problem is the question of whether intruding obstacles are detectable in such displays. Although the discrimination model can handle detection situations by making B the original image A plus the intrusion, this detection model makes the inappropriate assumption that the observer knows where the intrusion will be. Effects of signal uncertainty need to be added to our models. A pilot needs to make decisions rapidly. The models need to predict not just the probability of a correct decision, but the probability of a correct decision by the time the decision needs to be made. That is, the models need to predict latency as well as accuracy. Luce and Green have generated models for auditory detection latencies. Similar models are needed for visual detection. Most image quality models are designed for static imagery. Watson has been developing a general spatial-temporal vision model to optimize video compression techniques. These models need to be adapted and calibrated for AVID applications.

Ahumada, AL↗