Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

Roman-WFI: characterization of widefield chromatic response

Characterization of filter transmission is essential to control systematic chromatic errors in photometric surveys. Widefield surveys employ large filter optics viewed from high angles of incidence. Large optics may have variations in edge wavelength definition across their surface, and their spectral response shifts at high incidence angles. I will describe the characterization of the band definitions for the Wide Field Instrument of the Roman Space Telescope as part of its thermal vacuum test campaigns and through preparatory work. The measurement approach and analysis enable joint retrieval of chromatic response variations across the filter and focal plane. Additional tests probe out-of-band response and thermal straylight paths.

Eric Switzer↗

PVQAT TG2 Update

Thermal and mechanical fatigue: What are the appropriate number of thermal cycles for a long-term reliability test? Should this number be climate specific? What is the effect and appropriate level of DML testing?

14 SOLAR ENERGY↗

Nuclear code case development of printed-circuit heat exchangers with thermal and mechanical performance testing

The U.S. Department of Energy has agreed to fund a three-year integrated research project to close technical gaps involved with compact heat exchangers to be used in nuclear applications. This paper introduces the goals of the project, the research institutions, and industrial partners working in collaboration to develop a draft Boiler and Pressure Vessel Code Case for this technology. Heat exchanger testing, as well as non-destructive and destructive evaluation, will be performed by researchers across the country to understand the performance of compact heat exchangers. Testing will be performed using coolants and conditions proposed for Gen IV Reactor designs. Preliminary observations of the mechanical failure mechanisms of the heat exchangers using destructive and non-destructive methods is presented. Unit-cell finite element models assembled to help predict the mechanical behavior of these high-temperature components are discussed as well. Performance testing methodology is laid out in this paper along with preliminary modeling results, an introduction to x-ray and neutron inspection techniques, and results from a recent pressurization test of a printed-circuit heat exchanger. The operational and quality assurance knowledge gained from these models and validation tests will be useful to developers of supercritical CO 2 systems, which commonly employ printed-circuit heat exchangers.

42 ENGINEERING↗

Environmental testing of a Q-switched Nd:YLF laser and a Nd:YAG ring laser

A Q-switched Nd:YLF laser (model 110-02) and a Nd:YAG ring laser (model 120-04) from Lightwave Electronics were subjected to thermal and vibration tests similar to what can be expected during launch and flight on a spacecraft. Even though these lasers were not designed for space flight, environmental tests were performed to identify major design weaknesses. Laser performance (output power, energy, pulsewidth, lasing threshold etc.) were measured prior to and after thermal vibration tests. Average output power of the Q-switched laser degraded 15-20 percent after thermal tests and an additional 20-25 percent after vibration tests. Post diagnostic tests revealed that degradation of the Q-switched laser was due to misalignment of pump focusing optics and the laser cavity.

Robinson, D. L.↗

Thermal fatigue performance of integrally cast automotive turbine wheels

Fluidized bed thermal fatigue testing was conducted on 16 integrally cast automotive turbine wheels for 1000-10,000 (600 sec total) thermal cycles at 935/50 C. The 16 wheels consisted of 14 IN-792 + 1% Hf and 2 gatorized AF2-1DA wheels; 6 of the IN-792 + Hf wheels contained crack arrest pockets inside the blade root flange. Temperature transients during the thermal cycling were measured in three calibration tests using either 18 or 30 thermocouples per wheel. Thermal cracking based on crack length versus accumulated cycles was greatest for unpocketed wheels developing cracks in 8-13 cycles compared to 75-250 cycles for unpocketed wheels. However, pocketed wheels survived up to 10,000 cycles with crack lengths less than 20 mm, whereas two unpocketed wheels developed 45 mm long cracks in 1000-2000 cycles.

Humphreys, V. E.↗

Accelerated Fuel Qualification of Fast Modular Reactor Fuel in a Thermal Reactor: Modeling and Simulation Paired with Irradiation Testing

The accelerated fuel qualification (AFQ) methodology is applied by simulating accelerated fuel tests of the General Atomics Electromagnetic Systems’ fuel system for its 44-MW(electric) gas-cooled, fast-spectrum fast modular reactor (FMR). This fuel is comprised of UO 2 pellets in SiGA® cladding, a silicon carbide ceramic matrix composite. Fast reactors, like the FMR, offer many benefits, including high fuel utilization and flexibility, but may require a lengthy material design process if tests are performed using fast neutron irradiation alone. A thermal neutron irradiation can instead be used to rapidly test how well key components of the current material models extend to high burnup. Thermal neutrons produce a different radial power distribution within the pin than fast neutrons. However, the temperature and burnup values for the two neutron types are comparable, and the differences between the simulated fuel responses are relatively small, demonstrating the weak sensitivity of the physics-based fuel model calculations on the neutron type and the irradiation rate. Furthermore, the deformation of the SiGA cladding saturates after about 1 displacement per atom for both neutron spectra. In an accelerated fuel test, the irradiation time required to reach the target fuel burnup can be reduced by a factor of 3 by using a small rodlet with a 45% smaller pellet diameter while maintaining the same linear power. Therefore, the time for data collection up to high burnup can be significantly reduced while maintaining the same temperature profile, which largely determines the material response. Tests of fuel rodlets of standard and compact size will be carried out in the Idaho National Laboratory’s Advanced Test Reactor (ATR), including full size and compact rodlets with varying gap sizes. By applying physics-based mechanistic modeling and simulation in accordance with the AFQ methodology, this type of compact rodlet testing in a thermal test reactor captures the necessary phenomena to test fuel material models up to high burnup and to simulate the expected impact of fast neutron radiation on the fuel in FMR operations. Finally, this approach to testing fast reactor fuels in existing thermal test reactors, paired with advanced physics-based mechanistic modeling and simulation, is expected to be applicable to a range of advanced fuels and will decrease the overall fuel qualification timeframe from decades to years.

Advanced test reactor (ATR)↗

A thermal active restrained shrinkage ring test to study the early age concrete behaviour of massive structures

In massive concrete structures, cracking may occur during hardening, especially if autogenous and thermal strains are restrained. The concrete permeability due to this cracking may rise significantly and thus increase leakage (in tank, nuclear containment...) and reduce the durability. The restrained shrinkage ring test is used to study the early age concrete behaviour (delayed strains evolution and cracking). This test shows, at 20 {sup o}C and without drying, for a concrete mix which is representative of a French nuclear power plant containment vessel (w/c ratio equal to 0.57), that the amplitude of autogenous shrinkage (about 40 {mu}m/m for the studied concrete mix) is not high enough to cause cracking. Indeed, in this configuration, thermal shrinkage is not significant, whereas this is a major concern for massive structures. Therefore, an active test has been developed to study cracking due to restrained thermal shrinkage. This test is an evolution of the classical restrained shrinkage ring test. It allows to take into account both autogenous and thermal shrinkages. Its principle is to create the thermal strain effects by increasing the temperature of the brass ring (by a fluid circulation) in order to expand it. With this test, the early age cracking due to restrained shrinkage, the influence of reinforcement and construction joints have been experimentally studied. It shows that, as expected, reinforcement leads to an increase of the number of cracks but a decrease of crack widths. Moreover, cracking occurs preferentially at the construction joint.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗