At least 1,603 records · Page 89

Summary of Working Group 3: Laser and High-Gradient Structure-Based Acceleration

Accelerating particles at high gradients with high efficiencies is essential for reduction of size and cost of future accelerators for science and industry. This includes a future multi-TeV e+e- collider for particle, free-electron lasers for basic energy sciences and national security, industrial accelerators for energy and environmental applications, and accelerators for other applications. One way to achieve this is to use advanced externally-powered structures, both laser and RF driven. Working Group 3 (WG3) discussed novel accelerating structures with new geometries, new materials, frequencies from microwave to THz and optical spectrum, and operating conditions from room temperature to cryogenic. Presentations included recent advances in understanding RF breakdown and multipactor phenomena at different frequencies and materials, and other physics limitations to the accelerating gradient. Other relevant topics, such as developing high-gradient photoinjectors, high-efficiency RF power sources, and RF structures for a potential muon collider were discussed also. More details on each of the WG3 topics can be found in the articles published in these proceedings.

43 PARTICLE ACCELERATORS↗

Demonstration of Combined Zero-Valent Iron and Electrical Resistance Heating for In Situ Trichloroethene Remediation

The effectiveness of in situ treatment using zero-valent iron to remediate sites with non-aqueous phase or significant sediment-associated contaminant mass can be limited by relatively low rates of mass transfer to bring contaminants in contact with the reactive media. For a field test in a trichloroethene source area, combining moderate-temperature (maximum 50oC) subsurface electrical resistance heating with in situ ZVI treatment was shown to accelerate dechlorination and dissolution rates by a factor of 4 to 6 based on organic daughter products and a factor 8-16 using a chloride concentrations. A mass-discharge-based analysis was used to evaluate reaction, dissolution, and volatilization at ambient groundwater temperature (~10oC) and as temperature was increased up to about 50oC. Increased reaction and contaminant dissolution were observed with increased temperature, but volatilization was minimal during the test because in situ reactions maintained low aqueous-phase TCE concentrations.

54 ENVIRONMENTAL SCIENCES↗

Development of an Accelerated Test Design for Predicting the Service Life of the Solar Array at Mead, Nebraska

An accelerated life test is described which was developed to predict the life of the 25 kW photovoltaic array installed near Mead, Nebraska. A quantitative model for accelerating testing using multiple environmental stresses was used to develop the test design. The model accounts for the effects of thermal stress by a relation of the Arrhenius form. This relation was then corrected for the effects of nonthermal environmental stresses, such as relative humidity, atmospheric pollutants, and ultraviolet radiation. The correction factors for the nonthermal stresses included temperature-dependent exponents to account for the effects of interactions between thermal and nonthermal stresses on the rate of degradation of power output. The test conditions, measurements, and data analyses for the accelerated tests are presented. Constant-temperature, cyclic-temperature, and UV types of tests are specified, incorporating selected levels of relative humidity and chemical contamination and an imposed forward-bias current and static electric field.

Gaines, G. B.↗

FRIB cryogenic distribution system

The Michigan State University Facility for Rare Isotope Beams (MSU-FRIB) helium distribution system has been revised to include bayonet/warm valve type disconnects between each cryomodule and the transfer line distribution system, similar to the Thomas Jefferson National Accelerator Facility (JLab) and the Spallation Neutron Source (SNS) cryogenic distribution systems. The heat loads at various temperature levels and some of the features in the design of the distribution system are outlined. The present status, the plans for fabrication, and the procurement approach for the helium distribution system are also included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reliability of Electronics for Cryogenic Space Applications Being Assessed

Many future NASA missions will require electronic parts and circuits that can operate reliably and efficiently in extreme temperature environments below typical device specification temperatures. These missions include the Mars Exploration Laboratory, the James Webb Space Telescope, the Europa Orbiter, surface rovers, and deep-space probes. In addition to NASA, the aerospace and commercial sectors require cryogenic electronics in applications that include advanced satellites, military hardware, medical instrumentation, magnetic levitation, superconducting energy management and distribution, particle confinement and acceleration, and arctic missions. Besides surviving hostile space environments, electronics capable of low-temperature operation would enhance circuit performance, improve system reliability, extend lifetime, and reduce development and launch costs. In addition, cryogenic electronics are expected to result in more efficient systems than those at room temperature.

Patterson, Richard L.↗

Temporal signal stability of KCl:Eu{sup 2+} storage phosphor dosimeters

Purpose: Current KCl:Eu{sup 2+} prototype dosimeters require a wait time of 12 h between irradiation and dosimetric readout. Although irradiating the dosimeters in the evening and reading on the following day works well in the clinical schedule, reducing the wait time to few hours is desirable. The purposes of this work are to determine the origin of the unstable charge-storage centers and to determine if these centers respond to optical or thermal excitation prior to dosimetric readout. Methods: Pellet-style KCl:Eu{sup 2+} dosimeters were fabricated in-house for this study. A 6 MV photon beam was used to irradiate the dosimeters. After x ray irradiation, dosimeters were subjected to external excitation with near-infrared (NIR) light, ultraviolet (UV) light, or thermal treatment. Photostimulated luminescence (PSL) signal's temporal stability was subsequently measured at room temperature over a few hours using a laboratory PSL readout system. The dosimeters were also placed in a cryostat to measure the temperature dependence of the temporal stability down to 10 K. Results: Strong F-band was present in the PSL stimulation spectrum, indicating that F-centers were the electron-storage centers in KCl:Eu{sup 2+} where an electron was stored at a chlorine anion vacancy. Due to deep energy-depth (2.2 eV), F-centers were probably not responsible for the fast fading in the first a few hours post x ray irradiation. In addition, weak NIR bands were present. However, there was no change in PSL stabilization rate with intense NIR excitation, suggesting that the NIR bands played no role in the PSL fading. At temperatures lower than 77 K there was almost no signal fading with time. Noticeable PSL was observed for undoped KCl samples at room temperature, suggesting that Cl{sub 2}{sup -} V{sub k} centers served as hole-storage centers for both undoped and doped KCl where a hole was trapped by a chlorine molecular ion. V{sub k} centers were stable at low temperature and became mobile at room temperature, probably causing the observed PSL fading with time. On the other hand, V{sub k} center could be stabilized by Eu{sup 2+} activator or oxygen in the lattice, leading to the stable component in the PSL. A thermal process at elevated temperatures (60 Degree-Sign C or higher) was able to significantly accelerate the migration process resulting in a fast stabilization of PSL. However, this could not be accomplished using intense UV excitation. Conclusions: Thermal treatment enables KCl:Eu{sup 2+} prototypes to be ready for readout in 1 h without the need of applying a large time-dependent correction factor. However, this cannot be achieved using optical preexcitation.

36 MATERIALS SCIENCE↗

Interstellar clouds in high-speed, supersonic flows: Two-dimensional simulations

We present a series of gasdynamical simulations of the interaction of a dense, cool interstellar cloud with a high-speed, supersonic wind that confines and accelerates the embedded cloud. Our goal is to attempt to determine if such clouds can survive various potentially disruptive instabilities, that occur at their peripheries, long enough to be accelerated to speeds which are comparable to the wind velocity. These simulations are performed using two-dimensional, Eulerian gas dynamics on both an axisymmetric (about the cloud axis) and 'slab' geometric grid. The spatial and temporal resolutions of the simulations are varied over a wide range to investigate the effects of small-scale instabilities on the overall acceleration of clouds and the development of large-scale, disruptive instabilities. Also, we study the effects of wind/cloud Mach number variations by changing the wind speed constant at about 12 km/s (which corresponds to a cloud temperature of 10,000 K). The current simulations track the evolution of clouds as they are accelerated to speeds approximately 4-5 times greater than their internal sound speeds. Furthermore, the models with the highest resolution were extended far beyond quasi-linear Rayleigh-Taylor growth times reaching 6-7 Rayleigh-Taylor growth times for the largest scale instabilities before being terminated because of the accumulation of errors at the rear grid boundary.

Schiano, A. V. R.↗

The Cold and Hot Electron Populations, Temperatures and Their Transports in the Edge Plasma of the ORNL CAPRICE ECR Ion Source

The edge plasma of the ORNL CAPRICE ECR ion source is studied by directly measuring, with electrical probes, its local plasma parameters such as plasma density, temperature and electron energy distribution characteristics at different rf power levels, at various pressures, at various axial magnetic field strengths and different distances from the resonant zone. It is found that the edge plasma can be approximated to be bi-Maxwellian, whose characteristics become more pronounced at the more distant positions from the ECR zone, at lower source pressures and at increased magnetic field strengths. These trends are consistently explained in terms of long-range electron-electron and electron-ion Coulomb scattering collisions that occur during the transport of hot electrons from the ECR plasma to the probe and their frequency dependence on electron temperature and density.

43 PARTICLE ACCELERATORS↗

NMDQi Nuclear Materials Discovery and Qualification Initiative Conference Overview

The Nuclear Materials Discovery and Qualification Initiative (NMDQi) is designed to accelerate nuclear materials qualification to fulfill the promises of early and advanced reactor technologies as a safe, clean, and low-cost baseload energy. Materials development and qualification in the nuclear industry is by definition challenging due to stringent safety requirements, limited availability of specialized facilities for materials irradiation and testing, and the challenging high-temperature, high-radiation environment. NMDQi will establish tools and capabilities that will greatly accelerate the nuclear fuels and materials development process. These tools will provide both computationally informed insights and high-throughput infrastructure with the goal of completing qualification in a single pass. In this approach, materials must be fabricated with a range of properties of interest so that materials performance can be examined in parallel, rather than with multiple discrete specimens. Advanced manufacturing (AM) techniques, which can produce complex component geometries, microstructures, and compositions, are ideal. The improved process monitoring and control that AM can provide are ideal for ensuring and reducing material variability, which will be particularly important as standards committees pursue regulations for AM components. However, gaining these benefits requires overcoming the substantial barrier of qualifying AM processes and the resulting materials and components for supporting research campaigns and eventually nuclear service.

36 MATERIALS SCIENCE↗

Iodine Effects on Medical Isotope Producer Delay & Guard Bed Temperature and Performance in Support of NA-23 Program

In support of NA-23’s objective to accelerate the establishment of a reliable commercial United States (U.S.) domestic supply of 99Mo produced without the use of highly enriched uranium (HEU), the Pacific Northwest National Laboratory (PNNL) was tasked with modeling the performance of activated carbon delay and guard beds that may be typical for non-HEU 99Mo production processes. The specific tasks accomplished by PNNL included calculations of long-term effects of iodine on delay bed performance and development of a finite element simulation to better understand delay bed performance under various scenarios specifically with radioxenon and radioiodine decay heating of the delay beds. The main issue of interest in this study is understanding the effect of iodine on the abatement performance of the beds if iodine is not sufficiently removed from gases prior to reaching the delay beds. Finite element simulations of delay bed performance were developed using COMSOL Multiphysics® Software. These simulations are based on partial differential equations that describe xenon and iodine adsorption, heat transfer and decay of radioxenon and radioiodine isotopes. Heat transfer in the activated carbon beds is simulated with a heat source tied to the decay of radioactive xenon and iodine species. These simulations were used to investigate delay bed temperature and hold up time using radioxenon and radioiodine activities and flowrates expected from a non-HEU production process. A bounding case scenario was simulated, where all the iodine was released into the delay beds due to insufficient guarding of the delay beds. In addition, preliminary investigations of the guard beds were conducted.

07 ISOTOPE AND RADIATION SOURCES↗

OBSERVATION OF HEATING BY FLARE-ACCELERATED ELECTRONS IN A SOLAR CORONAL MASS EJECTION

We report a Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) observation of flare-accelerated electrons in the core of a coronal mass ejection (CME) and examine their role in heating the CME. Previous CME observations have revealed remarkably high thermal energies that can far surpass the CME's kinetic energy. A joint observation by RHESSI and the Atmospheric Imaging Assembly of a partly occulted flare on 2010 November 3 allows us to test the hypothesis that this excess energy is collisionally deposited by flare-accelerated electrons. Extreme ultraviolet (EUV) images show an ejection forming the CME core and sheath, with isothermal multifilter analysis revealing temperatures of ∼11 MK in the core. RHESSI images reveal a large (∼100 × 50 arcsec{sup 2}) hard X-ray (HXR) source matching the location, shape, and evolution of the EUV plasma, indicating that the emerging CME is filled with flare-accelerated electrons. The time derivative of the EUV emission matches the HXR light curve (similar to the Neupert effect observed in soft and HXR time profiles), directly linking the CME temperature increase with the nonthermal electron energy loss, while HXR spectroscopy demonstrates that the nonthermal electrons contain enough energy to heat the CME. This is the most direct observation to date of flare-accelerated electrons heating a CME, emphasizing the close relationship of the two in solar eruptive events.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the Relative and Absolute Microgravity Environment of Space Platforms, Recent Flight Results, and Determination of the Spatial Microgravity Field

Microgravity material processing in space, such as crystal growth, requires specific and accurate knowledge of the very low frequency, very low level microgravity. This means knowledge of absolute microgravity levels. Most acceleration measurement systems for space platforms only measure 'microvibrations,' the measurement of the absolute microgravity level being severely corrupted by bias errors, temperature hysteresis, nonlinearity by-products, and bias changes due to launch vibrations. An advanced system was developed incorporating a fixed 3-axis acceleration measurement system with improved signal conditioning and Invertible Accelerometers for absolute measurements. The higher sensitivity channels have lower frequency low pass filtering to meet crystal growers demands for recording of low level/low frequency disturbances. Also included is a pre-flight bias adjustment feature.

Bijvoet, J. A.↗

Plasma jet acceleration of dust particles to hypervelocities

A convenient method to accelerate simultaneously hundreds of micron-size dust particles to a few km/s over a distance of about 1 m is based on plasma drag. Plasma jets which can deliver sufficient momentum to the dust particles need to have speeds of at least several tens of km/s, densities of the order of 10{sup 22} m{sup -3} or higher, and low temperature {approx}1 eV, in order to prevent dust destruction. An experimental demonstration of dust particles acceleration to hypervelocities by plasma produced in a coaxial gun is presented here. The plasma flow speed is deduced from photodiode signals while the plasma density is measured by streaked spectroscopy. As a result of the interaction with the plasma jet, the dust grains are also heated to high temperatures and emit visible light. A hypervelocity dust shower is imaged in situ with a high speed video camera at some distance from the coaxial gun, where light emission from the plasma flow is less intense. The bright traces of the flying microparticles are used to infer their speed and acceleration by employing the time-of-flight technique. A simple model for plasma drag which accounts for ion collection on the grain surface gives predictions for dust accelerations which are in good agreement with the experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of emittance at low energy

Ideally, experimental measurements of all beam parameters should be made at the exit of the injector. This has not been possible on DARHT Axis-II for various practical reasons. In particular, the emittance has not been measured there. This note reviews the methods we have used for emittance measurements on the linear induction accelerator (LIA) at low-energy (< 10 MeV). It includes a discussion of some of the issues associated with making those measurements on a beam from the injector. A successful plan for emittance measurements at any energy should incorporate measures to deal with these issues. To begin with, it should be recognized that emittance measurements at the injector are not critical for beam physics in the accelerator. The emittance at the injector has very little effect on accelerator beam dynamics except for an increase in size near the end, where the beam becomes emittance dominated. Therefore, imperfect knowledge has little effect on the design and implementation of a tune. This point is illustrated in Fig. 1, which shows beam envelope calculations for our present tune over a wide range of emittances. Compare this with using the wrong diode voltage in the tune design. Figure 2 shows the effect on the beam envelope of a 2% error in the measurement of diode voltage. Therefore, a few years ago, when we made plans for beam measurements at the diode while we were upgrading the injector cells, our highest priority was on magnetic spectrometer measurements of energy. These measurements were to be used to cross calibrate the diode-voltage monitor, so that accurate diode voltage measurements could be made on every shot after the spectrometer was removed. If emittance measurements at the injector are required, then three widely used methods should be considered. These are focusing magnet scans, the use of an emittance mask (pepper pot), and optical transition radiation (OTR). We have used all three of these on our accelerators. These are invasive methods. There are noninvasive methods that we have not yet used. For example, under some conditions the beam size obtained with diamagnetic loops can be used in conjunction with the envelope equation to infer emittance. To date our diamagnetic loop data has not been of sufficient quality to do this. Another technique is to measure the beam-distribution quadrupole moment with BPMs dispersed in a quadrupole magnet lattice. Our BPMs have this capability, but the only quad lattice is in the downstream transport (DST), so this method is deferred until we operate the DST. All three methods reviewed here are invasive, and require the insertion of a target into the beam. Therefore, there is always the accompanying risk of inadvertent destruction of the target, and scattering of target material throughout the accelerator or injector. The target damage mechanism is target heating to a temperature hot enough to evolve gas, which is impact ionized by the beam, which is then ion focused to a small enough spot for the energy density to damage the target material, often destructively. Target heating is directly proportional to beam current density and pulse length. Therefore, the key to minimizing risk of target damage is to design for a large beam at the target, low current from the diode, and the shortest possible current pulse. The large-beam requirement compromises emittance measurements with OTR or focal scans, but not with the pepper pot technique. Finally, to ensure a short pulse even if the crowbar fails, the Marx generator should be reconfigured to produce the shortest possible pulse.

43 PARTICLE ACCELERATORS↗

Temperature Mapping analysis of Nitrogen-doped Niobium Radio Frequency Cavity

Nitrogen-doping of niobium superconducting radio-frequency (SRF) cavity has been shown to significantly improve the quality factors as compared to the standard treated niobium cavities. However, the nitrogen-doped cavities generally quench at lower accelerating gradients. To understand the possible sources of rf losses in nitrogen-doped cavities that could reduce the quench field, we used 576 thermometer sensors to map the temperature distribution of the outer cavity surface while increasing the accelerating field. Our measurements have revealed a strong effect of the cavity cooldown rate on the intensity of hot spots and their spatial distribution, indicating a significant contribution from trapped vortices on the RF losses.

Makita, Junki↗

Knowledge of coronal heating and solar-wind acceleration obtained from observations of the solar wind near 1 AU

Clues to the nature of the mechanisms responsible for heating the corona and accelerating the solar wind can be obtained by contrasting the properties of the quasi-stationary and transient states of the solar wind. Substantial differences exist in the proton temperatures and anisotropies, the entropy, the field strength, the Alfvenicity of fluctuations in the field, the distribution of MHD discontinuities, and the helium abundance of the two types of flow. Those differences are displayed as a function of the solar wind speed. Several signals of wave acceleration can be found in the data for quasi-stationary flows. The relatively smooth velocity dependences of proton temperature, helium abundance, and frequency of occurrence of rotational discontinuities suggest that the acceleration mechanisms for flow from coronal holes, coronal streamers, and the quasi-stationary low-speed flows between them may be basically the same, differing only in degree.

Neugebauer, M.↗

Imaging with Spherically Bent Crystals or Reflectors

This paper consists of two parts: Part I describes the working principle of a recently developed x-ray imaging crystal spectrometer, where the astigmatism of spherically bent crystals is being used with advantage to record spatially resolved spectra of highly charged ions for Doppler measurements of the ion-temperature and toroidal plasmarotation- velocity profiles in tokamak plasmas. This type of spectrometer was thoroughly tested on NSTX and Alcator C-Mod, and its concept was recently adopted for the design of the ITER crystal spectrometers. Part II describes imaging schemes, where the astigmatism has been eliminated by the use of matched pairs of spherically bent crystals or reflectors. These imaging schemes are applicable over a wide range of the electromagnetic radiation, which includes microwaves, visible light, EUV radiation, and x-rays. Potential applications with EUV radiation and x-rays are the diagnosis of laserproduced plasmas, imaging of biological samples with synchrotron radiation, and lithography.

43 PARTICLE ACCELERATORS↗