Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Observation of Narrow-Band Terahertz Coherent Cherenkov Radiation from a Cylindrical Dielectric-Lined Waveguide

We report experimental observation of narrow-band coherent Cherenkov radiation driven by a subpicosecond electron bunch traveling along the axis of a hollow cylindrical dielectric-lined waveguide. For an appropriate choice of dielectric wall thickness, a short-pulse beam current profile excites only the fundamental mode of the structure, producing energetic pulses in the terahertz range. We present detailed measurements showing a narrow emission spectrum peaked at 367+-3 GHz from a 1 cm long fused silica capillary tube with submillimeter transverse dimensions, closely matching predictions. We demonstrate a 100 GHz shift in the emitted central frequency when the tube wall thickness is changed by 50 mum. Calibrated measurements of the radiated energy indicate up to 10 muJ per 60 ps pulse for an incident beam charge of 200 pC, corresponding to a peak power of approximately 150 kW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Steady-State Microbunching in a Storage Ring for Generating Coherent Radiation

Synchrotrons and storage rings deliver radiation across the electromagnetic spectrum at high repetition rates, and free electron lasers produce radiation pulses with high peak brightness. However, at present few light sources can generate both high repetition rates and high brightness outside the optical range. We propose to create steady-state microbunching (SSMB) in a storage ring to produce coherent radiation at a high repetition rate or in continuous wave mode. In this Letter we describe a general mechanism for producing SSMB and give sample parameters for extreme ultraviolet lithography and submillimeter sources. We also describe a similar arrangement to produce two pulses with variable spacing for pump-probe experiments. With technological advances, SSMB could reach the soft x-ray range (<10 nm).

43 PARTICLE ACCELERATORS↗

Polarized 3 He as a Probe for Short-Range Spin-Dependent Interactions

We have studied the relaxation of a spin-polarized gas in a magnetic field, in the presence of short-range spin-dependent interactions. As a main result we have established a link between the specific properties of the interaction and the dependence of the spin-relaxation rate on the magnitude of the holding magnetic field. This allows us to formulate a new, extremely sensitive method to study (pseudo) magnetic properties at the submillimeter scale, which are difficult to access by other means. The method has been used as a probe for nucleon-nucleon axionlike P, T violating interactions which yields a two-order-of-magnitude improved constraint on the coupling strength (g s g p ) as a function of the force range (&lambda;): g s g p &lambda;} 2 <3x10 -27 m 2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ringed Structures of the HD 163296 Protoplanetary Disk Revealed by ALMA

We present Atacama Large Millimeter and Submillimeter Array observations of the protoplanetary disk around the Herbig Ae star HD 163296 that trace the spatial distribution of millimeter-sized particles and cold molecular gas on spatial scales as small as 25 astronomical units (A.U.). The image of the disk recorded in the 1.3 mm continuum emission reveals three dark concentric rings that indicate the presence of dust depleted gaps at about 60, 100, and 160 A.U. from the central star. The maps of the 12 CO, 13 CO, and C 18 O J = 2 - 1 emission do not show such structures but reveal a change in the slope of the radial intensity profile across the positions of the dark rings in the continuum image. By comparing the observations with theoretical models for the disk emission, we find that the density of CO molecules is reduced inside the middle and outer dust gaps. However, in the inner ring there is no evidence of CO depletion. From the measurements of the dust and gas densities, we deduce that the gas-to-dust ratio varies across the disk and, in particular, it increases by at least a factor 5 within the inner dust gap compared to adjacent regions of the disk. The depletion of both dust and gas suggests that the middle and outer rings could be due to the gravitational torque exerted by two Saturn-mass planets orbiting at 100 and 160 A.U. from the star. On the other hand, the inner dust gap could result from dust accumulation at the edge of a magnetorotational instability dead zone, or from dust opacity variations at the edge of the CO frost line. Observations of the dust emission at higher angular resolution and of molecules that probe dense gas are required to establish more precisely the origins of the dark rings observed in the HD 163296 disk.

79 ASTRONOMY AND ASTROPHYSICS↗

The neutron and its role in cosmology and particle physics

Experiments with cold and ultracold neutrons have reached a level of precision such that problems far beyond the scale of the present standard model of particle physics become accessible to experimental investigation. Because of the close links between particle physics and cosmology, these studies also permit a deep look into the very first instances of our Universe. First addressed in this article, in both theory and experiment, is the problem of baryogenesis, the mechanism behind the evident dominance of matter over antimatter in the Universe. The question of how baryogenesis could have happened is open to experimental tests, and it turns out that this problem can be curbed by the very stringent limits on an electric dipole moment of the neutron, a quantity that also has deep implications for particle physics. Then the recent spectacular observation of neutron quantization in the Earth's gravitational field and of resonance transitions between such gravitational energy states is discussed. These measurements, together with new evaluations of neutron scattering data, set new constraints on deviations from Newton's gravitational law at the picometer scale. Such deviations are predicted in modern theories with extra dimensions that propose unification of the Planck scale with the scale of the standard model. These experiments start closing the remaining ''axion window'' on new spin-dependent forces in the submillimeter range. Another main topic is the weak-interaction parameters in various fields of physics and astrophysics that must all be derived from measured neutron-decay data. Up until now, about 10 different neutron-decay observables have been measured, much more than needed in the electroweak standard model. This allows various precise tests for new physics beyond the standard model, competing with or surpassing similar tests at high energy. The review ends with a discussion of neutron and nuclear data required in the synthesis of the elements during the ''first three minutes'' and later on in stellar nucleosynthesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Quasi-Periodic Linear Feeder for the Impurity Granular Injection on DIII-D

Injection of solid nonfuel pellets has been actively used as a tool for pacing and mitigation of edge localized modes (ELMs). In DIII-D, effective ELM pacing has been demonstrated by the high-frequency injection of lithium and carbon submillimeter spheres, using the impurity granule injector (IGI). This device injects granules into the plasma at speeds up to 150 m/s, through impact with a rotating impeller. In the IGI, high-frequency granule delivery was accomplished through a vibrational granule dropper, in which high time-average rates are obtained at the cost of lack of period control. Here, we present a new in-line granule feeder, capable of delivering granules of size 0.2-2 mm with no restriction of material properties, at quasi-periodic rates of up to 150 Hz, for 0.7-mm diameter lithium granules (600 Hz using 0.3-mm granules). The new dropper mechanism combines two piezo-in-line units; one which feeds the impeller and one which circulates granules that are filtered out of the feeder path. A remotely adjustable filter eliminates granules that are stacked, oversized, or side by side allowing the formation of a single moving granule injection line. The granules fall off the in-line feeder exit one at a time, achieving a quasi-periodic delivery rate proportional to the exit speed. At higher rates, the periodicity deteriorates. This behavior was studied using high-speed cameras and electrostatic measurements, and it was found that at drop rates <60 Hz, the granule delivery period has a variation of ±25% which appears to be caused by gaps which develop in the last centimeter of the injection line, as granules exit off the moving track. The linear feeder concept is robust against bridge instabilities and clogging issues, thanks to the simple diverter filter and constant recirculation of granules. Furthermore, the open-top design of the device facilitates refilling the device from separate reservoirs and has easy access for directly monitoring operation and adjustment. This paper describes the details of the in-line feeder design, along with several design iterations. The goal is a robust in-vacuum mechanism that can deliver granule flow ranging from a single particle to a line of particles at 150 per second, using different sizes and materials from the same apparatus.

42 ENGINEERING↗

Hoop Tensile Failure Stress of 500 µm-Diameter Ceramic Spheres

The tensile failure stress of a brittle-material sphere is important to the survival of the sphere itself but is particularly relevant to systems that employ such spheres for applications in which the sphere exterior is subjected to tension during system fabrication or operation. That maximum hoop or tangential stress can be measured by diametrally compressing a C-sphere specimen directly machined from such spheres. This combination of specimen geometry and test method was conceived at Oak Ridge National Laboratory around 20 years ago. Although the C-sphere geometry has been tested with larger spheres, the ease and efficacy of its testing are unknown for submillimeter sphere diameters. To consider this, C-sphere specimens were machined from yttria-stabilized zirconia (YSZ) spheres of ∼500 µm diameter. The maximum (hoop or tangential) tensile stress was determined as a function of compressive failure force and specimen dimensions using finite element analysis. Companion effective area and volume as a function of Weibull modulus were computed. Hoop tensile failure stresses were then measured and fractography conducted to examine flaw type and location and to estimate the mirror constant of this YSZ grade. This novel study demonstrates that hoop tensile failure stress can be determined with sub-millimeter brittle-material spheres.

Delia, Daniel [ORNL] (ORCID:0000000209023239)↗

A survey of fractured SrTiO{sub 3} surfaces : from the micro-meter to nano-meter scale.

Cross-sectional scanning tunneling microscopy was utilized to study fractured perovskite oxide surfaces. It was found that for the non-cleavable perovskite oxide, SrTiO{sub 3}, atomically flat terraces could be routinely created with a controlled fracturing procedure. Optical, scanning electron and scanning tunneling microscopies, and a profilometer were used to obtain information from submillimeter to submicrometer scales of the fractured surface topography.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is intended to be a fast-response, time-dependent beam diagnostic for measuring the spot size emitted from radiographic x-ray sources. It will measure spot sizes from submillimeters up to several millimeters for photon energies in the range of 150 keV to 20 MeV with doses as low as 0.03 rad up to 500 rad. The D-TRSD performs fast data acquisition as radiographic x-ray sources typically produce pulses in the tens of nanosecond ranges. The system will be optimized to capture multiple individual pulses in time within the same data record. The data collected will be used to support beam tuning and source optimization with on-the-fly evaluation of radiographic source performance. The diagnostic is based on penumbral imaging techniques. A scintillating fiber array of parallel aligned fibers is positioned in the beam path with a high-Z rolled edge inserted between the source and the array, thereby creating the penumbral x-ray signal that is captured by the D-TRSD system. The light from the scintillation conversion is recorded by individual avalanche photodiode detectors integrated into custom digitizer electronics. The penumbra is used to calculate the spot of the beam on the axis orthogonal to the fiber array based on the magnification from the rolled edge, the resolution of the spaced fibers, and the rotation of the array normal to the beam path. Many arrays can be used to capture additional spot widths about different rotations. The D-TRSD system is modular, software-driven, and easier to use than legacy TRSD systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MicroRT - Small animal conformal irradiator

A novel small animal conformal radiation therapy system has been designed and prototyped: MicroRT. The microRT system integrates multimodality imaging, radiation treatment planning, and conformal radiation therapy that utilizes a clinical {sup 192}Ir isotope high dose rate source as the radiation source (teletherapy). A multiparameter dose calculation algorithm based on Monte Carlo dose distribution simulations is used to efficiently and accurately calculate doses for treatment planning purposes. A series of precisely machined tungsten collimators mounted onto a cylindrical collimator assembly is used to provide the radiation beam portals. The current design allows a source-to-target distance range of 1-8 cm at four beam angles: 0 deg. (beam oriented down), 90 deg., 180 deg., and 270 deg. The animal is anesthetized and placed in an immobilization device with built-in fiducial markers and scanned using a computed tomography, magnetic resonance, or positron emission tomography scanner prior to irradiation. Treatment plans using up to four beam orientations are created utilizing a custom treatment planning system--microRTP. A three-axis computer-controlled stage that supports and accurately positions the animals is programmed to place the animal relative to the radiation beams according to the microRTP plan. The microRT system positioning accuracy was found to be submillimeter. The radiation source is guided through one of four catheter channels and placed in line with the tungsten collimators to deliver the conformal radiation treatment. The microRT hardware specifications, the accuracy of the treatment planning and positioning systems, and some typical procedures for radiobiological experiments that can be performed with the microRT device are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A prototype quantitative film scanner for radiochromic film dosimetry

We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction external-beam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RCF dosimetry. The scanner employed a stationary light source and detector with a moving antireflective glass film platen attached to a high precision computerized X-Y translation stage. An ultrabright red light emitting diode (LED) with a peak output at 633 nm and full width at half maximum (FWHM) of 16 nm was selected as the scanner light source to match the RCF absorption peak. A dual detector system was created using two silicon photodiode detectors to simultaneously measure incident and transmitted light. The LED light output was focused to a submillimeter (FWHM 0.67 mm) spot size, which was determined from a scanning knife-edge technique for measuring Gaussian optical beams. Data acquisition was performed with a 16-bit A/D card in conjunction with commercial software. The linearity of the measured densities on the scanner was tested using a calibrated neutral-density step filter. Sensitometric curves and three IMRT field scans were acquired with a spatial resolution of 1 mm for both radiographic film and RCF. The results were compared with measurements taken with a commercial diode array under identical delivery conditions. The RCF was rotated by 90 deg. and rescanned to study orientation effects. Comparison between the RCF and the diode array measurements using percent dose difference and distance-to-agreement criteria produced average passing rates of 99.0% using 3%/3 mm criteria and 96.7% using 2%/2 mm criteria. The same comparison between the radiographic film and diode array measurements resulted in average passing rates 96.6% and 91.6% for the above two criteria, respectively. No measurable light-scatter or interference scanner artifacts were observed. The RCF rotated by 90 deg. showed no measurable orientation effect. A scan of a 15x15 cm{sup 2} area with 1 mm resolution required 22 min to acquire. The LED densitometer provides an accurate film dosimetry system with 1 mm or better resolution. The scanner eliminates the orientation dependence of RCF dosimetry that was previously reported with commercial flatbed scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: A feasibility and accuracy study

Margin reduction for prostate radiotherapy is limited by uncertainty in prostate localization during treatment. We investigated the feasibility and accuracy of measuring prostate intrafraction motion using kV fluoroscopy performed simultaneously with radiotherapy. Three gold coils used for target localization were implanted into the patient's prostate gland before undergoing hypofractionated online image-guided step-and-shoot intensity modulated radiation therapy (IMRT) on an Elekta Synergy linear accelerator. At each fraction, the patient was aligned using a cone-beam computed tomography (CBCT), after which the IMRT treatment delivery and fluoroscopy were performed simultaneously. In addition, a post-treatment CBCT was acquired with the patient still on the table. To measure the intrafraction motion, we developed an algorithm to register the fluoroscopy images to a reference image derived from the post-treatment CBCT, and we estimated coil motion in three-dimensional (3D) space by combining information from registrations at different gantry angles. We also detected the MV beam turning on and off using MV scatter incident in the same fluoroscopy images, and used this information to synchronize our intrafraction evaluation with the treatment delivery. In addition, we assessed the following: the method to synchronize with treatment delivery, the dose from kV imaging, the accuracy of the localization, and the error propagated into the 3D localization from motion between fluoroscopy acquisitions. With 0.16 mAs/frame and a bowtie filter implemented, the coils could be localized with the gantry at both 0 deg. and 270 deg. with the MV beam off, and at 270 deg. with the MV beam on when multiple fluoroscopy frames were averaged. The localization in two-dimensions for phantom and patient measurements was performed with submillimeter accuracy. After backprojection into 3D the patient localization error was (-0.04{+-}0.30) mm, (0.09{+-}0.36) mm, and (0.03{+-}0.68) mm in the right-left (RL), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. Simulations showed that while oscillating (stationary) motion cannot be effectively represented in 3D, linearly drifting (nonstationary) motion is detectable with good accuracy. These results show that measuring prostate intrafraction motion using a single kV imager during radiotherapy is feasible and can be performed with acceptable accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of three-dimensional intrafraction motion through real-time DMLC tracking

Tumor tracking using a dynamic multileaf collimator (DMLC) represents a promising approach for intrafraction motion management in thoracic and abdominal cancer radiotherapy. In this work, we develop, empirically demonstrate, and characterize a novel 3D tracking algorithm for real-time, conformal, intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)-based radiation delivery to targets moving in three dimensions. The algorithm obtains real-time information of target location from an independent position monitoring system and dynamically calculates MLC leaf positions to account for changes in target position. Initial studies were performed to evaluate the geometric accuracy of DMLC tracking of 3D target motion. In addition, dosimetric studies were performed on a clinical linac to evaluate the impact of real-time DMLC tracking for conformal, step-and-shoot (S-IMRT), dynamic (D-IMRT), and VMAT deliveries to a moving target. The efficiency of conformal and IMRT delivery in the presence of tracking was determined. Results show that submillimeter geometric accuracy in all three dimensions is achievable with DMLC tracking. Significant dosimetric improvements were observed in the presence of tracking for conformal and IMRT deliveries to moving targets. A gamma index evaluation with a 3%-3 mm criterion showed that deliveries without DMLC tracking exhibit between 1.7 (S-IMRT) and 4.8 (D-IMRT) times more dose points that fail the evaluation compared to corresponding deliveries with tracking. The efficiency of IMRT delivery, as measured in the lab, was observed to be significantly lower in case of tracking target motion perpendicular to MLC leaf travel compared to motion parallel to leaf travel. Nevertheless, these early results indicate that accurate, real-time DMLC tracking of 3D tumor motion is feasible and can potentially result in significant geometric and dosimetric advantages leading to more effective management of intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical imaging analysis of microscopic radiation dose gradients in Gafchromic EBT film using a digital microscope

By providing superior localization and immobilization, stereotactic radiosurgery (SRS) is capable of delivering millimeter spheres of dose to intracranial targets with submillimeter precision. Several authors have proposed new SRS solutions to dramatically reduce beam penumbra to hundreds of microns. These solutions require new quality assurance methods capable of penumbra measurement at the micron scale. This article examines the capability of a digital microscope, with translation stage and associated software, to resolve dose gradients in Gafchromic EBT film at this level. To produce very steep penumbra, films were irradiated in phantom beneath pinhole collimators using lower energy x rays (100 kVp, 300 kVp, and Iridium-192) and minimal geometric penumbra contribution. For film analysis, a method was developed which improved the signal to noise ratio by finding the center of the irradiation spot, generating several radial dose profiles and averaging these to obtain the final off-axis dose profile. Optical density was converted to dose using a calibration curve. The experimentally determined off-axis dose profiles were compared with MCNP Monte Carlo simulations which replicated the irradiation geometry and served to validate our measured data. The measured 80%-20% penumbral widths were 46 {mu}m{+-}26 {mu}m (100 kVp, 2 mm field size), 69 {mu}m{+-}27 {mu}m (300 kVp, 2 mm field size), and 241 {mu}m{+-}31 {mu}m (Ir-192, 1 mm field size). These penumbral widths agreed with Monte Carlo simulations within experimental uncertainty. Our findings suggest that reading Gafchromic EBT films using a digital microscope with translation stage is suitable for the quality assurance of very sharp penumbra able to resolve gradients to within at least 30 {mu}m.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anniversary Paper: The role of medical physicists in developing stereotactic radiosurgery

This article is a tribute to the pioneering medical physicists over the last 50 years who have participated in the research, development, and commercialization of stereotactic radiosurgery (SRS) and stereotactic radiotherapy utilizing a wide range of technology. The authors have described the evolution of SRS through the eyes of physicists from its beginnings with the Gamma Knife in 1951 to proton and charged particle therapy; modification of commercial linacs to accommodate high precision SRS setups; the multitude of accessories that have enabled fine tuning patients for relocalization, immobilization, and repositioning with submillimeter accuracy; and finally the emerging technology of SBRT. A major theme of the article is the expanding role of the medical physicist from that of advisor to the neurosurgeon to the current role as a primary driver of new technology that has already led to an adaptation of cranial SRS to other sites in the body, including, spine, liver, and lung. SRS continues to be at the forefront of the impetus to provide technological precision for radiation therapy and has demonstrated a host of downstream benefits in improving delivery strategies for conventional therapy as well. While this is not intended to be a comprehensive history, and the authors could not delineate every contribution by all of those working in the pursuit of SRS development, including physicians, engineers, radiobiologists, and the rest of the therapy and dosimetry staff in this important and dynamic radiation therapy modality, it is clear that physicists have had a substantial role in the development of SRS and theyincreasingly play a leading role in furthering SRS technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical observation of energy loss distribution and practical range of positrons from a {sup 18}F water solution in a water-equivalent phantom

The energy loss distribution of {beta}{sup +} particles is closely related to their maximum penetration depth distribution and annihilation point distribution. The latter is of practical importance for positron emission tomography. Experimental data related to the energy loss distribution are important for comprehensive validation of physics and simulation models of {beta}{sup +} interactions. In this paper the authors present a new experimental approach that allows them to visually observe the {beta}{sup +} energy loss distribution of a solution of nuclear medicine radioisotopes in a plastic scintillator using an optical camera. The authors also report a set of the first experimental results. A water solution of {sup 18}F was localized in a small hole in a plastic scintillator (BC430). Optical imaging of the scintillator yielded visual images of the energy loss distribution with a submillimeter resolution. The radial dependence in the energy distribution was quantitatively measured by analysis of the images, and exponential fitting parameters were obtained. The authors observed that the results of Monte Carlo simulation with EGS5 (version 1.0.2) and GEANT4 (version 4.9.01.p01) were consistent with those obtained experimentally. The results of the Monte Carlo simulation indicated that for a linear scale, the energy loss distribution in the scintillator was approximately the same as that in water, and the relative shape of the energy loss distribution was close to those of the maximum penetration depth distribution and annihilation point distribution. This paper also presents discussions about the further possibilities of this optical imaging approach. Thus, optical observation of the {beta}{sup +} energy loss distribution in a scintillator is a promising technique for visual and quantitative experimental studies of {beta}{sup +} emission from a solution of radioisotopes that are used in nuclear medicine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources

Purpose: The x-ray transmitted beam from any material/tissue depends on the complex refractive index (n=1-{delta}+i{beta}), where {delta} is responsible for the phase shift and {beta} is for the beam attenuation. Although for human tissues, the {delta} cross section is about 1000 times greater than the {beta} ones in the x-ray energy range from 10 to 150 keV, the gain in breast tumor visualization of phase-contrast mammography (PCM) with respect to absorption contact imaging (AI) is limited by the maximum dose that can be delivered to the patient. Moreover, in-line PC imaging (PCI) is the simplest experimental mode among all available x-ray PCI techniques since no optics are needed. The latter is a fundamental requirement in order to transfer the results of laboratory research into hospitals. Alternative to synchrotron radiation sources, the implementation of relativistic Thomson-scattering (TS) x-ray sources is particularly suitable for hospital use because of their high peak brightness within a relatively compact and affordable system. In this work, the possibility to realize PCM using a TS source in a hospital environment is studied, accounting for the effect of a finite deliverable dose on the PC visibility enhancement with respect to AI. Methods: The contrast-to-noise ratio of tumor-tissue lesions in PCM has been studied on the bases of a recent theoretical model, describing image contrast formation by means of both wave-optical theory and the mutual coherence formalism. The latter is used to describe the evolution, during wave propagation, of the coherence of the wave field emitted by a TS source. The contrast-to-noise ratio for both PCI and AI has been analyzed in terms of tumor size, beam energy, detector, and source distances, studying optimal conditions for performing PCM. Regarding other relevant factors which could influence ''tumor'' visibility, the authors have assumed simplified conditions such as a spherical shape description of the tumor inclusion, a constant surrounding background, ideal conditions for the calculus of the contrast-to-noise ratio. Results: The results show the possibility to enhance with PCI the signal-to-noise ratio for features in the submillimeter scale. This finding could give PCM a great advantage with respect to AI, opening the possibility to decrease the number of wrong diagnoses before histological exams. The results agree with experimental evidences obtained by Dreossi et al.[D. Dreossi et al., ''The mammography project at the SYRMEP beamline,'' Eur. J. Radiol. 68, S58-S62 (2008)] with real PCM using synchrotron radiation. Conclusions: The challenging characteristics of TS sources, suitable for PCM, should be fluxes of at least 10{sup 11} photons/s emitted by very small sources of about 10 {mu}m, together with moderate energy spreads (less than 10%) in order to realize both sufficient spatial coherence and enough fluence on the patient, collecting images in reasonable exposure times. These fluxes will be achieved by next generation TS sources which are already under development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--Experiments, simulation, and dosimetry study

Purpose: To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. Methods: The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Results: Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage ({approx}2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to <2%) if the MLC blockage problem were relieved. The information acquired for repositioning using combined MV-kV images was found to have submillimeter accuracy. Conclusions: This work demonstrated with a current clinical setup that substantial reduction of adverse targeting effects of intrafraction prostate motion can be realized. The proposed adaptive imaging strategy incurs minimal imaging dose to the patient as compared to other stereoscopic imaging techniques.

60 APPLIED LIFE SCIENCES↗