SEARCH · Engineering Papers
Results for “study”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Inverse Liner Z-Pinch: An Experimental Pulsed Power Platform for Studying Radiative Shocks
Not Available
Structural and Physical Property Studies of Amorphous Zn-In-Sn-O Thin Films
The structures in amorphous (a-) Zn, Sn co-doped In 2 O 3 (ZITO) thin films grown by pulsed laser deposition on glass under varying oxygen pressure or with varying Sn:Zn ratios were determined using X-ray absorption spectroscopy and anomalous X-ray scattering. Typical structures around cations in a-ZITO films are described and compared with crystalline (c-) ZITO films. The results show that the Zn cations are fourfold coordinated with Zn–O bond lengths of 1.98 ± 0.02 Å, which is close to that in bulk ZnO. As a consequence, the second coordination shells around Zn contract. At longer distances away from Zn, the structure is commensurate with the averaged structure. The unit volume around In also contracts slightly compared to bulk In 2 O 3 , whereas the Sn–O bond length is similar to the one in bulk SnO 2 . These unique structural characteristics may account for the films' superior thermal stability over amorphous Sn-doped In 2 O 3 , and suggest that Zn and Sn act as network-forming cations. Like in c-ZITO, coordination numbers (N) around Sn, In, and Zn follow the order N Sn > N In > N Zn . Unlike in c-ZITO, where electrical properties change significantly with a slight variation in the Sn:Zn ratio, this variation does not markedly alter the electrical properties, or the local structures, of a-ZITO films. Dramatic changes in the electrical properties occur for films grown under various oxygen pressures, which point to oxygen “defects” as the source of charge carriers.
Electrical and hydrogen reduction enhances kinetics in doped zirconia and ceria: I. grain growth study
Not provided.
Effects of surface initial condition on aqueous corrosion of glass-A study with a model nuclear waste glass
Being a nonequilibrium material, the structure of glass varies with the sample history. Thus, the initial surface condition of a glass can vary with the preparation condition and have a large impact on its reactivity. This paper shows that the aqueous corrosion behavior of international simple glass (ISG) varies depending on the initial surface state. The ISG glass samples were prepared as-polished-only and polished-then-annealed and they were immersed in aqueous solution saturated with soluble SiO 2 at 30°C (modeling a mild condition) and at 90°C (modeling a severe condition). Molecular dynamics simulations were performed to obtain coordination numbers of network formers of ISG to assist oxygen speciation calculations. The surface structures of as-prepared and corroded ISG samples were analyzed using various imaging and spectroscopic techniques. Among these analyses, only the oxygen speciation with x-ray photoelectron spectroscopy showed discernable differences between two uncorroded surfaces with different preparation histories; all other methods could not differentiate the surface preparation history before aqueous corrosion. Such minor difference in chemical structures was found to have a profound impact on corrosion behaviors in the mild condition. In the harsh condition, the surface history dependence was not as drastic as the corrosion in the mild condition. The analysis results of the corroded surfaces suggested that the thickness and structure of the alteration layer formed on ISG in aqueous corrosion can vary with the initial surface state.
A COMPARATIVE STUDY OF CONTRASTING MACHINE LEARNING FRAMEWORKS APPLIED TO RANS MODELING OF JETS IN CROSSFLOW.
Abstract not provided.
An Experimental Study of Ductile Failure Under Multi-axial Loading.
Abstract not provided.
Optical emission spectroscopic studies and comparisons of CH{sub 3}F/CO{sub 2} and CH{sub 3}F/O{sub 2} inductively coupled plasmas
A CH{sub 3}F/CO{sub 2} inductively coupled plasma (ICP), sustained in a compact plasma reactor, was investigated as a function of power (5–400 W) and feed gas composition, at a pressure of 10 mTorr, using optical emission spectroscopy and rare gas actinometry. Number densities of H, F, and O increased rapidly between 74% and 80% CO{sub 2}, ascribed to the transition from polymer-covered to polymer-free reactor walls, similar to that found previously in CH{sub 3}F/O{sub 2} ICPs at 48% O{sub 2}. Below 40% O{sub 2} or CO{sub 2}, relative emission intensity ratios were almost identical for most key species in CH{sub 3}F/O{sub 2} and CH{sub 3}F/CO{sub 2} ICPs except for higher OH/Xe (a qualitative measure of OH and H{sub 2}O densities) over the full range of CH{sub 3}F/O{sub 2} composition. The number density of H, F, and O increased with power in CH{sub 3}F/CO{sub 2} (20%/80%) plasmas (polymer-free walls), reaching 4.0, 0.34, and 1.6 × 10{sup 13}/cm{sup 3}, respectively, at 300 W. The CO number density increased with power and was estimated, based on self-actinometry, to be 8.8 × 10{sup 13}/cm{sup 3} at 300 W. The CO{sub 2} number density was independent of power below 40 W (where very little decomposition occurred), and then decreased rapidly with increasing power, reaching 2.8 × 10{sup 13}/cm{sup 3} at 300 W, corresponding to 83% dissociation. Films deposited on p-Si, 10 cm from the open, downstream end of the plasma reactor, were analyzed by x-ray photoelectron spectroscopy. Between 10% and 40% CO{sub 2} or O{sub 2} addition to CH{sub 3}F, film deposition rates fell and O content in the films increased. Faster deposition rates in CH{sub 3}F/CO{sub 2} plasmas were ascribed mainly to a larger thermodynamic driving force to form solid carbon, compared with CH{sub 3}F/O{sub 2} plasmas. Oxygen content in the films increased with increasing CO{sub 2} or O{sub 2} addition, but for the same deposition rate, no substantial differences were observed in the composition of the films.
Real-time x-ray studies of indium island growth kinetics
The authors have investigated the early stages of indium island formation and growth by vapor phase deposition on room temperature sapphire using real-time grazing incidence small angle x-ray scattering (GISAXS), followed by ex-situ atomic force microscopy and scanning electron microscopy. The results are consistent with the formation and coalescence of hemispherical islands, as described by Family and Meakin. Monte Carlo simulations of systems of coalescing islands were used to supplement and quantify the results of GISAXS, and a good agreement is seen between the data and the simulations.
Thermal chemistry of copper acetamidinate atomic layer deposition precursors on silicon oxide surfaces studied by XPS
The thermal surface chemistry of copper(I)-N,N′-di-sec-butylacetamidinate, [Cu({sup s}Bu-amd)]{sub 2}, a metalorganic complex recently proposed for the chemical-based deposition of copper films, has been characterized on SiO{sub 2} films under ultrahigh vacuum conditions by x-ray photoelectron spectroscopy (XPS). Initial adsorption at cryogenic temperatures results in the oxidation of the copper centers with Cu 2p{sub 3/2} XPS binding energies close to those seen for a +2 oxidation state, an observation that the authors interpret as the result of the additional coordination of oxygen atoms from the surface to the Cu atoms of the molecular acetamidinate dimer. Either heating to 300 K or dosing the precursor directly at that temperature leads to the loss of one of its two ligands, presumably via hydrogenation/protonation with a hydrogen/proton from a silanol group, or following a similar reaction on a defect site. By approximately 500 K the Cu 2p{sub 3/2}, C 1s, and N 1s XPS data suggest that the remaining acetamidinate ligand is displaced from the copper center and bonds to the silicon oxide directly, after which temperatures above 900 K need to be reached to promote further (and only partial) decomposition of those organic moieties. It was also shown that the uptake of the Cu precursor is self-limiting at either 300 or 500 K, although the initial chemistry is somewhat different at the two temperatures, and that the nature of the substrate also defines reactivity, with the thin native silicon oxide layer always present on Si(100) surfaces being less reactive than thicker films grown by evaporation, presumably because of the lower density of surface nucleation sites.
Scandium function in "scandate" thermionic cathodes: A microspot synchrotron radiation x-ray photoelectron spectroscopy study of co-adsorbed Ba-Sc-O on W(100)
Explore the source record for details and available documents.
Modality comparison for small animal radiotherapy: A simulation study
Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by the SARRP plan due to the sensitivity of the lower energy microCT beam to target heterogeneities and image noise. Conclusions: The two treatment planning examples demonstrate that modern small animal radiotherapy techniques employing image guidance, variable collimation, and multiple beam angles deliver superior dose distributions to small animal tumors as compared to conventional treatments using a single-field irradiator. For deep-seated mouse tumors, however, higher-energy conformal radiotherapy could result in higher doses to critical organs compared to lower-energy conformal radiotherapy. Treatment planning optimization for small animal radiotherapy should therefore be developed to take full advantage of the novel conformal systems.
Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems
Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.