Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “structure performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Digital Twins for Materials

Digital twins are emerging as powerful tools for supporting innovation as well as optimizing the in-service performance of a broad range of complex physical machines, devices, and components. A digital twin is generally designed to provide accurate in-silico representation of the form (i.e., appearance) and the functional response of a specified (unique) physical twin. This paper offers a new perspective on how the emerging concept of digital twins could be applied to accelerate materials innovation efforts. Specifically, it is argued that the material itself can be considered as a highly complex multiscale physical system whose form (i.e., details of the material structure over a hierarchy of material length) and function (i.e., response to external stimuli typically characterized through suitably defined material properties) can be captured suitably in a digital twin. Accordingly, the digital twin can represent the evolution of structure, process, and performance of the material over time, with regard to both process history and in-service environment. This paper establishes the foundational concepts and frameworks needed to formulate and continuously update both the form and function of the digital twin of a selected material physical twin. The form of the proposed material digital twin can be captured effectively using the broadly applicable framework of n-point spatial correlations, while its function at the different length scales can be captured using homogenization and localization process-structure-property surrogate models calibrated to collections of available experimental and physics-based simulation data.

36 MATERIALS SCIENCE↗

Numerical Simulations of Flow-Induced Deflections in MITR LEU Fuel Plate Due to Channel Size Disparity

The hydromechanical stability of the fuel plates in parallel coolant channels of a Materials Testing Reactor (MTR) fuel element design is of great importance to the safety of research and test reactors. Previous analytical, experimental, and numerical efforts focused on parallel channels with the same or similar size; also, in the prior numerical simulations, the fuel plate was often assumed to be perfectly flat. This work presents the results of a fluid-structure interaction simulation performed to evaluate the flow-induced deflections of the fuel plates in the low-enriched uranium (LEU, <20 wt% 235 U) fuel element design for the conversion (from highly enriched uranium) of the Massachusetts Institute of Technology Reactor (MITR-II, also referred to as MITR). Various manufacturing and assembly tolerances of the MITR LEU elements are considered in the analysis, and the effects of channel size disparity, nonideal plate shape, and flow rate uncertainty are investigated. Results show that, for all cases analyzed, the deflection occurs toward the larger channel, and the change in any channel stripe remains small (less than 0.021 mm) compared to fabrication tolerances. In addition to simulation work, a hydraulic performance test of the MITR LEU fuel element is currently planned to support conversion to the use of LEU fuel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Achieving 20.1% Efficiency in Organic Solar Cells Through Interconnected Fibrillar Networks via Local Molecular Stacking

ABSTRACT The performance of organic solar cells (OSCs) is governed by how molecular packing evolves into interconnected networks that facilitate exciton dissociation and charge transport. Using an all‐small‐molecule blend DR3TSBDT:Y6 as a model system, we study how local molecular stacking evolves into performance‐relevant morphology during solvent vapor annealing (SVA) and subsequent thermal annealing (TA). SVA promotes end‐to‐end stacking of amorphous acceptors to form interconnected fibrils, while TA compacts inter‐fibril spacing without disrupting favorable local order. Such molecular‐to‐morphological refinements broaden light absorption, enhance charge transport, and markedly improve device efficiency. Extending this approach to additional blend systems (D18:Y6, D18:L8‐BO, and DR3TSBDT:L8‐BO) yields similar structural evolution and performance gains, with the D18:L8‐BO system achieving up to 20.10% PCE. Our study establishes control over local stacking in amorphous acceptors into fibrillar networks as a general and effective route to realize high‐performance OSCs.

Wu, Junying↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of solid rocket motor for space shuttle booster, volume 2, book 5, appendices E thru H

Preliminary parametric studies were performed to establish size, weight and packaging arrangements for aerodynamic decelerator devices that could be used for recovery of the expended solid propellant rocket motors used in the launch phase of the Space Shuttle System. Computations were made using standard engineering analysis techniques. Terminal stage parachutes were sized to provide equilibrium descent velocities for water entry that are presently thought to be acceptable without developing loads that could exceed the boosters structural integrity. The performance characteristics of the aerodynamic parachute decelerator devices considered are based on analysis and prior test results for similar configurations and are assumed to be maintained at the scale requirements of the present problem.

Source record↗

Nonlinear structural analysis of cylindrical thrust chambers using viscoplastic models

The results are presented of a viscoplastic stress-strain analysis of a cylindrical thrust chamber used in experiments that were designed to simulate the SSME operating conditions. The inelastic strain was calculated by using a viscoplastic model, and a quasi-three-dimensional structural analysis was performed by using a finite element program MARC. The temperatures and pressures were calculated by using the loading cycles of experiments, and these temperatures and pressures were used in the computations. The deformed shape of the component was predicted after the end of each loading cycle. The predicted shape qualitatively replicated the deformed shape of the component as observed in experiments. The results indicate that the use of viscoplastic models for structural analysis may lead to more realistic life assessments of experimental thrust chambers.

Arya, Vinod K.↗

A Framework for Preliminary Design of Aircraft Structures Based on Process Information

This report discusses the general framework and development of a computational tool for preliminary design of aircraft structures based on process information. The described methodology is suitable for multidisciplinary design optimization (MDO) activities associated with integrated product and process development (IPPD). The framework consists of three parts: (1) product and process definitions; (2) engineering synthesis, and (3) optimization. The product and process definitions are part of input information provided by the design team. The backbone of the system is its ability to analyze a given structural design for performance as well as manufacturability and cost assessment. The system uses a database on material systems and manufacturing processes. Based on the identified set of design variables and an objective function, the system is capable of performing optimization subject to manufacturability, cost, and performance constraints. The accuracy of the manufacturability measures and cost models discussed here depend largely on the available data on specific methods of manufacture and assembly and associated labor requirements. As such, our focus in this research has been on the methodology itself and not so much on its accurate implementation in an industrial setting. A three-tier approach is presented for an IPPD-MDO based design of aircraft structures. The variable-complexity cost estimation methodology and an approach for integrating manufacturing cost assessment into design process are also discussed. This report is presented in two parts. In the first part, the design methodology is presented, and the computational design tool is described. In the second part, a prototype model of the preliminary design Tool for Aircraft Structures based on Process Information (TASPI) is described. Part two also contains an example problem that applies the methodology described here for evaluation of six different design concepts for a wing spar.

Rais-Rohani, Masoud↗

HVAC System Performance for Energy Codes (Technical Brief)

The prescriptive path is likely the most widely used approach for commercial code compliance in the United States. Though easy to implement, the prescriptive approach does not discriminate between high-performing and poorly performing heating, ventilation, air conditioning (HVAC) system configurations that are both minimally compliant. To meet aggressive energy and carbon reduction goals, energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. HVAC System Performance is a discipline performance path and provides a simpler solution to HVAC system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution that could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A web-based calculation tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach has also been evaluated by the ASHRAE Standard 90.1 Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Evaluation of Structural Analysis Methodologies for Space Deployable Structures

Benchmarks are introduced for evaluating the performance of numerical simulations of space deployable structures. These benchmarks embody the key challenges of interest to future large space deployable structures, including large angle motion, contact between flexible bodies, and the presence of both soft and stiff mechanical components. The benchmarks were used in companion studies to evaluate the ADAMS multibody dynamics code, the LS-Dyna nonlinear finite element code, and the Sierra large-scale parallel nonlinear finite element code. In the past, only multibody codes would have been considered for this application. This study found that all three codes could be used for these benchmarks, a finding that may lead to larger scale, higher fidelity simulations in the future.

Mobrem, Mehran↗

Hydrogen Bonding and Its Effect on the Orientational Dynamics of Water Molecules inside Polyelectrolyte Brush-Induced Soft and Active Nanoconfinement

Despite being the most ubiquitous compound on Earth, the fundamental properties of water are not fully understood, especially in nanoconfinement. Densely grafted polyelectrolyte (PE) molecules attain the configuration of a “brush”: these PE brushes, due to their ability to form hydrogen bonds (HBs) with water via the PE functional groups, act as a source of soft and active nanoconfinement for the brush-trapped water molecules. In this paper, we study the effects of PE brush-induced confinement on the structure, dynamics and energetics of the water-water and water-PE HBs. Our results indicate a significant weakening of the HBs from bulk to sparsely grafted to densely grafted brushes. i.e., by increasing the degree of brush-induced nanoconfinement. We explain that this weakening of water-water HBs is caused by the disruption of the extended network of water molecules within the brush-induced nanoconfinement. This is confirmed by performing a ring structure analysis of the water molecules, which yields a reduction in the average ring size at higher degrees of brush-induced nanoconfinement (i.e., at higher brush grafting densities). Furthermore, we investigate the role of HB on the orientational dynamics of the water molecules. Here, we observe that the rotational motion of the water molecules becomes sluggish inside the PE brushes. Recent findings have indicated that the water and counterions trapped in brush-induced nanoconfinement demonstrate structures (in combination with the PE functional group) analogous to that in “water-in-salt” electrolytes that have seen extensive recent uses for Li-ion battery applications. However, the rotational dynamics of water molecules inside the brush-induced nanoconfinement is found to be distinctly different from that of conventional “water-in-salt” electrolytes in absence of any confinement; therefore, the present study will provide the necessary platform towards conceptualizing polymer-based nanoconfinement for battery applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Project ARES 2: High-altitude battery-powered aircraft

A high-altitude, battery-powered, propeller-driven aircraft was designed and is being built by undergraduate students at California State University, Northridge. The aircraft will fly at an altitude of 104,000 ft at Mach 0.2 (190 ft/sec) and will be instrumented to record flight performance data, including low Reynolds number propeller and airfoil information. This project will demonstrate the feasibility of electric-powered flight in a low-density, low-temperature Earth environment that models the atmosphere of Mars. Data collected will be used to design a Mars aircraft to investigate the surface of Mars prior to manned missions. The instrumented payload and the mission profile for the high-altitude Earth flight were determined. Detailed aerodynamic and structural analyses were performed. Control, tracking, and data recording subsystems were developed. Materials were obtained and fabrication begun. The aircraft has a 32-ft wing span, a wing area of 105 sq ft, is 17.5 ft long, has a 12-in payload bay, and weighs 42 lb. It is composed primarily of lightweight materials, including Mylar, and composite materials, including graphite/epoxy and aramid core honeycomb sandwich. Low-altitude flight testing to check guidance and control systems and to calibrate data-gathering instruments will take place this summer, followed shortly by the 104,000-ft flight.

Source record↗

Comparison of the Experimental Performance of Ferroelectric CPW Circuits with Method of Moment Simulations and Conformal Mapping

Experimental measurements of coplanar waveguide (CPW) circuits atop thin films of ferroelectric Ba(x)Sr(1-x)TiO3 (BST) were made as a function bias from 0 to 200 V and frequency from 0.045 to 20 GHz. The resulting phase shifts are compared with method of moments electromagnetic simulations and a conformal mapping analysis to determine the dielectric constant of the BST films. Based on the correlation between the experimental and the modeled data, an analysis of the extent to which the electromagnetic simulators provide reliable values for the dielectric constant of the ferroelectric in these structures has been performed. In addition, to determine how well the modeled data compare with experimental data, the dielectric constant values were also compared to low frequency measurements of interdigitated capacitor circuits on the same films. Results of these comparisons will be presented.

VanKeuls, Fred W.↗

The Impact of Europium as a Fission Product Surrogate on Chromium Corrosion in Molten Chloride Salt

The rising interest in molten salts, both as thermal energy storage media and as high-temperature solvents for fissile materials in advanced nuclear reactors, has spurred significant growth in research on structural and functional salt-facing materials. Impurities, such as water, play a significant role in the degradation of materials in molten salt environments. Other impurities, such as fission products, are expected to accumulate in molten salts during normal reactor operation and can affect the properties of the salt and salt-facing materials. During normal reactor operation, rare-earth element species are expected to form as byproducts of fission reactions, potentially degrading or altering the performance of both structural and functional materials exposed to salts. Here, in this work, fission product surrogates, europium metal and EuCl 3 , were added to the KCl-MgCl 2 salt while exposing pure Cr specimens in the melt at 600 and 700 °C for 1000 h. Low reactivity was observed with the baseline salt, while both the Eu and EuCl 3 additions to the salt resulted in increased mass loss of Cr specimens. A capillary electrophoresis technique was developed to enable the detection of low parts-per-million (ppm) concentrations of europium (Eu) in chloride salt both before and after exposure of Cr metal. This technique provides a sensitive and reliable method for monitoring trace levels of Eu, which is critical for understanding the interactions and potential contamination effects in salt-facing materials during reactor operation. This quantification technique can be applied to other cationic and anionic contaminants in halide salts.

chloride salt↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in mid-2020, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center's Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20 K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is an assessment of thermal model pre-test prediction performance against actual payload response during the OTIS CV test. Overall, the thermal model performed exceedingly well at predicting schedule and payload response. Looking in depth, this work examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. The insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

Testing↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in early 2019, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center's Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is a preliminary assessment of thermal model performance against actual payload response during the OTIS CV test. It examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. It is hoped that the insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

JWST↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in early 2019, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center’s Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is a preliminary assessment of thermal model performance against actual payload response during the OTIS CV test. Overall, the thermal model performed exceedingly well at predicting schedule and payload response. Looking in depth, this work examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. It is hoped that the insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

Yang, Kan↗

Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Broadband Infrared Antireflection Structured Silicon Surfaces

Silicon and germanium are materials often used for IR windows and optical elements. However they have a very high index of refraction, in the order of three to four, which causes large reflection losses on each surface. These losses are especially high under large angles of incidence which are often desirable if signals are faint and fast optics are to be used. Solid antireflection coatings are either not available because materials with appropriate index of refraction do not exist, or their use is limited to a small wavelength range and small angles of incidence. We will present the status of our work to calculate, create, and test the performance of graded structures in Si to reduce its surface reflection. The structures are expected to work over the very broad wavelength range of 10 microns to 1000 microns and a wide range of angle of incidence. We have identified several high aspect ratio MEMS process techniques to create the structures and have done 3D electromagnetic modeling, which predicts significant effects. Measurements on different samples have validated our modeling.

Stewart, Kenneth↗