Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Global demand for rare earth resources and strategies for green mining

Rare earth elements (REEs) are essential raw materials for emerging renewable energy resources and ‘smart’ electronic devices. Global REE demand is slated to grow at an annual rate of 5% by 2020. This high growth rate will require a steady supply base of REEs in the long run. At present, China is responsible for 85% of global rare earth oxide (REO) production. To overcome this monopolistic supply situation, new strategies and investments are necessary to satisfy domestic supply demands. Concurrently, environmental, economic, and social problems arising from REE mining must be addressed. There is an urgent need to develop efficient REE recycling techniques from end-of-life products, technologies to minimize the amount of REEs required per unit device, and methods to recover them from fly ash or fossil fuel-burning wastes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct regeneration of degraded LiFePO4 cathodes via a separator-enabled prelithiation strategy

A persistent challenge in lithium-ion batteries is the loss of active lithium due to the solid electrolyte interphase (SEI) formation and associated side reactions. While prelithiation employing lithium replenishment separator (LRS) has been proven effective in compensating for lithium loss, previous studies have largely been accompanied by gas evolution or solid residue formation during the prelithiation process. To surmount this challenge, we present a LRS based on 4-fluoro-1,2-dihydroxybenzene lithium salt (LiDF), capable of mitigating lithium loss while producing decomposition products that integrate directly into the electrolyte as functional additives which can assist with the stability of the SEI, free from gas or solid formation, thus establishing a sustainable and environmentally benign strategy for lithium compensation. Incorporation of the LRS enables the pristine LiFePO4||graphite (Gr) full cell to achieve 10.8% higher capacity than the cell with a polypropylene separator (PPS) after 200 cycles at 0.5C. Remarkably, the degraded LiFePO4 (D-LFP)||Gr full cell with the LRS exhibits a 135.8% capacity improvement over the PPS-based cell after 500 cycles. These findings establish the LRS as a powerful approach for both boosting high-performance lithium-ion batteries and recovering the capacity of degraded batteries.

Tao, Fujun↗

Modeling strategy for progressive failure prediction in lithium-ion batteries under mechanical abuse

The prediction for the internal failure of lithium-ion batteries (LIBs) under external mechanical abuse loading remains a challenge for safe design. This paper systematically studies the modeling approach for progressive failure simulation and short-circuit prediction. Hemispherical indentation experiments are conducted on a battery specimen containing 5 representative sandwich (RS) layers to examine the deformation and progressive failure behavior of battery components. Three different models, viz, a high-fidelity detailed model, an intermediate homogenized model and a fully homogenized model, are developed and employed to simulate the progressive failure in a multi-layer battery specimen. The simulation results obtained using the three models all correlate well with experimental phenomena, capturing the overall stress-strain response and ultimate failure of the battery structure. The numerical results can help us understand the failure behavior and the mechanism for mechanical abuse-induced short circuit in LIBs. The feasibility of the three models for use in progressive failure prediction is compared by analyzing the capability of the models in predicting the critical failure events, the computational efficiency of the models, and the feasibility to implement coupled mechanical-electrochemical-thermal simulations. The results of this work provide useful insights on practical choices for the modeling strategy and safety design of LIBs under mechanical abuse conditions.

25 ENERGY STORAGE↗

An experimental study of fuel injection strategies in CAI gasoline engine

Combustion of gasoline in a direct injection controlled auto-ignition (CAI) single-cylinder research engine was studied. CAI operation was achieved with the use of the negative valve overlap (NVO) technique and internal exhaust gas re-circulation (EGR). Experiments were performed at single injection and split injection, where some amount of fuel was injected close to top dead centre (TDC) during NVO interval, and the second injection was applied with variable timing. Additionally, combustion at variable fuel-rail pressure was examined. Investigation showed that at fuel injection into recompressed exhaust fuel reforming took place. This process was identified via an analysis of the exhaust-fuel mixture composition after NVO interval. It was found that at single fuel injection in NVO phase, its advance determined the heat release rate and auto-ignition timing, and had a strong influence on NO{sub X} emission. However, a delay of single injection to intake stroke resulted in deterioration of cycle-to-cycle variability. Application of split injection showed benefits of this strategy versus single injection. Examinations of different fuel mass split ratios and variable second injection timing resulted in further optimisation of mixture formation. At equal share of the fuel mass injected in the first injection during NVO and in the second injection at the beginning of compression, the lowest emission level and cyclic variability improvement were observed. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Co-optimization of fuel properties, combustion system geometry, and injection strategy for conventional diesel fuel

Here, studies have shown that fuel properties can impact an engine’s operation in several ways, including ignition delay, sooting tendency, mixture formation, and combustion temperature. In mixing-controlled compression ignition (MCCI) engines, the fuel system design and piston bowl geometry significantly affect combustion performance and emissions. Based on current information, it is difficult to draw conclusions about fuel property effects and sensitivities. The central fuel hypothesis approach used in the US Department of Energy Co-Optima program has worked well for spark ignition fuels: identifying critical fuel property ranges is sufficient to screen fuel blends that are expected to maximize efficiency and reduce pollutant emissions. However, for MCCI-relevant fuels, the information gained from past studies is not sufficient to build such a merit function or to allow for performing a similar screening of fuel blends. It is hypothesized that a co-optimization of a fuel’s physical and chemical properties, combustion system geometry, and injection strategy could leverage synergies between the effects of the fuel properties and geometries, resulting in improved performance over state-of-the-art. A machine learning–assisted unconstrained global optimization algorithm was used to explore a design space comprising 23 independent variables. The results show that physical property effects were minimal even for large variations in fuel properties, and the only interaction effect that was observed was the effect of varied fuel density parameters on fuel/air mixture formation. Nevertheless, these interactions were not sufficient in magnitude to significantly affect optimization results. Therefore, analysis of the results suggests that fuel physical properties cannot be leveraged in a co-optimization context to increase engine efficiency.

33 ADVANCED PROPULSION SYSTEMS↗

Accelerating demand for residential solar photovoltaics: Can simple framing strategies increase consumer interest?

Household adoption of energy-efficient and renewable energy technologies has the potential to significantly reduce emissions from electricity generation. High upfront costs, however, are often a barrier to adoption, even when costs may be offset by future energy savings. Through a series of randomized experiments, we examine whether framing strategies grounded in behavioral economics and psychology can be used to increase the financial appeal of such products. Using mock ads for residential solar photovoltaics (PV), we test four frames: gain/loss framing, temporal framing, varied savings amounts, and simple vs. detailed savings calculations. Overall, we find that reframing the financial benefits of PV does not greatly influence the appeal of solar or the likelihood to respond to the mock ads. Instead, underlying consumer motivations and predispositions (i.e., perceived social support, consumer innovativeness, and personal pro-environmental norms) are the primary factors driving interest in adopting solar. Our findings suggest that tailoring messages to targeted consumer segments may be more effective than attempts to market the financial benefits of PV to broad audiences. Furthermore, the results also contribute to behavioral economics and psychology research by identifying contexts under which the gain/loss framing bias and the present/future framing bias may not apply.

14 SOLAR ENERGY↗

Containment strategy for subsurface H 2 storage based on time-dependent soft solids

Here, we propose an innovative containment strategy based on time-dependent soft solids, namely 2 wt% Laponite suspensions, to reinforce natural subsurface seals and engineer flow barriers, with an eye toward making H 2 subsurface storage scalable and geographically agnostic. This suspension can be injected at its initial low viscosity and elasticity into a porous medium, allowing for easy pumping and targeted delivery. Once inside the target zone, it matures into a soft solid with much higher viscosity and elasticity, acting as a potential flow barrier. We discuss the rheological properties of the suspensions and demonstrate that hydrogen does not adversely affect their microstructure, but rather increases the suspensions’ viscosity and elasticity. Moreover, the suspensions enhance the rock samples’ compressive strength, while hydrogen exposure increases their stiffness and ductility. The ability of rock samples saturated with the suspensions to contain higher injected gas pressures is enhanced by aging at higher temperatures.

08 HYDROGEN↗

Strategy for Online Correction of Rotational Organ Motion for Intensity-Modulated Radiotherapy of Prostate Cancer

Purpose: To develop and evaluate a correction strategy for prostate rotation using gantry and collimator angle adjustments. Methods and Materials: Gantry and collimator angle adjustments were used to correct for prostate rotation without rotating the table. A formula to partially correct for left-right (LR) rotations was derived through geometric analysis of rotation-induced clinical target volume (CTV) beam's-eye-view shape changes. For 10 prostate patients, intensity-modulated radiotherapy (IMRT) plans with different margins were created. Simulating CTV LR rotation and correcting each beam by a collimator rotation, the corrected CTV dose was compared with the original and uncorrected dose. Effects of residual geometric uncertainties were assessed using a Monte Carlo technique. A large number of treatments representative for prostate patients were simulated. Dose probability histograms of the minimum CTV dose (D{sub min}) were derived, with and without online correction, resulting in a more realistic margin estimate. Results: Dosimetric analysis of all IMRT plans showed that, with rotational correction and a 2-mm margin, D{sub min} was constant to within 3% for LR rotations up to {+-}15{sup o}. The Monte Carlo dose probability histograms showed that, with correction, a margin of 4 mm ensured that 90% of patients received a D{sub min} {>=}95% of the prescribed dose. Without correction a margin of 6 mm was required. Conclusions: We developed and tested a practical method for (online) correction of prostate rotation, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Motion Analysis of 100 Mediastinal Lymph Nodes: Potential Pitfalls in Treatment Planning and Adaptive Strategies

Purpose: The motion of mediastinal lymph nodes may undermine local control with involved-field radiotherapy. We studied patterns of nodal and tumor motion in 41 patients with lung cancer. Methods and Materials: Four-dimensional (4D) computed tomography planning scans were retrospectively evaluated to identify patients with clearly visible mediastinal lymph nodes. One hundred nodes from 14 patients with Stage I and 27 patients with Stage III were manually contoured in all 4D computed tomography respiratory phases. Motion was derived from changes in the nodal center-of-mass position. Primary tumors were also delineated in all phases for 16 patients with Stage III disease. Statistical analysis included a multivariate mixed-effects model of grouped data. Results: Average 3D nodal motion during quiet breathing was 0.68 cm (range, 0.17-1.64 cm); 77% moved greater than 0.5 cm, and 10% moved greater than 1.0 cm. Motion was greatest in the lower mediastinum (p = 0.002), and nodes measuring 2 cm or greater in diameter showed motion similar to that in smaller nodes. In 11 of 16 patients studied, at least one node moved more than the corresponding primary tumor. No association between 3D primary tumor motion and nodal motion was observed. For mobile primary tumors, phase offsets between the primary tumor and nodes of two or more and three or more phases were observed for 33% and 12% of nodes, respectively. Conclusions: Mediastinal nodal motion is common, with phase offsets seen between the primary tumor and different nodes in the same patient. Patient-specific information is needed to ensure geometric coverage, and adaptive strategies based solely on the primary tumor may be misleading.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Radiotherapy a Good Adjuvant Strategy for Men With a History of Cryptorchism and Stage I Seminoma?

Purpose: Men with cryptorchism can have aberrant abdominopelvic lymph node (LN) drainage or a different natural history if they develop Stage I seminoma. If so, the nodal echelons for metastases will not be reliable, and adjuvant radiotherapy (RT) would not be an ideal strategy. Methodsand Materials: Two prospectively maintained oncology databases were reviewed for men with a history of testicular seminoma and cryptorchidism. The primary endpoint was the 5-year relapse-free rate. Results: A total of 23 men were identified, most (n = 13) had had a tumor in a scrotal location after orchiopexy. After orchiectomy, 5 men were managed with surveillance, and 18 underwent RT to a median dose of 25 Gy (range, 20-30 Gy). All the radiation fields included the para-aortic LNs, and 13 included the ipsilateral pelvic LNs. After a median follow-up of 64 months (range, 2-148), 2 patients developed a relapse. One did so 4 months into a surveillance program in the para-aortic and ipsilateral pelvic LNs, sites that would have been treated had he undergone RT. The other patient developed a relapse in the contralateral testis 46 months after having undergone RT. It is likely that the latter patient had a metachronous primary rather than a relapse; hence, the 5-year relapse-free rate was 80% for surveillance and 100% for RT. Both patients underwent successful salvage treatment, and all patients were disease free and alive at the last follow-up visit. Conclusion: A history of cryptorchism does not appear to confer a greater risk of relapse for men with Stage I seminoma managed with radiotherapy. RT, surveillance, and adjuvant carboplatin chemotherapy are treatment options for these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter- and Intrafraction Patient Positioning Uncertainties for Intracranial Radiotherapy: A Study of Four Frameless, Thermoplastic Mask-Based Immobilization Strategies Using Daily Cone-Beam CT

Purpose: To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Methods and Materials: Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Results: Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts ({+-} SD) were 2.3 ({+-} 1.4), 2.2 ({+-} 1.1), 2.7 ({+-} 1.5), and 2.1 ({+-} 1.0) mm whereas intrafraction motion was 1.1 ({+-} 1.2), 1.1 ({+-} 1.1), 0.7 ({+-} 0.9), and 0.7 ({+-} 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. Conclusions: We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anal Cancer: An Examination of Radiotherapy Strategies

The Radiation Therapy Oncology Group 9811, ACCORD-03, and ACT II Phase III trials in anal cancer showed no benefit for cisplatin-based induction and maintenance chemotherapy, or radiation dose-escalation >59 Gy. This review examines the efficacy and toxicity of chemoradiation (CRT) in anal cancer, and discusses potential alternative radiotherapy strategies. The evidence for the review was compiled from randomized and nonrandomized trials of radiation therapy and CRT. A total of 103 retrospective/observational studies, 4 Phase I/II studies, 16 Phase II prospective studies, 2 randomized Phase II studies, and 6 Phase III trials of radiotherapy or chemoradiation were identified. There are no meta-analyses based on individual patient data. A 'one-size-fits-all' approach for all stages of anal cancer is inappropriate. Early T1 tumors are probably currently overtreated, whereas T3/T4 lesions might merit escalation of treatment. Intensity-modulated radiotherapy or the integration of biological therapy may play a role in future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Altered Cross-Linking of HSP27 by Zerumbone as a Novel Strategy for Overcoming HSP27-Mediated Radioresistance

Purpose: HSP27 or HSP25 negatively regulates apoptosis pathways after radiation or chemotherapeutic agents. Abrogation of HSP27 function may be a candidate target for overcoming radio- and chemoresistance. Methods and Materials: Zerumbone (ZER), a cytotoxic component isolated from Zingiber zerumbet smith. Clonogenic survival assay and flow cytometry after Annexin V staining were performed to determine in vitro sensitization effects of ZER with ionizing radiation. A nude mouse xenografting system was also applied to detect in vivo radiosensitizing effects of ZER. Results: ZER produced cross-linking of HSP27, which was dependent on inhibition of the monomeric form of HSP27. ZER was directly inserted between the disulfide bond in the HSP27 dimer and modified normal HSP27 dimerization. Pretreatment with ZER before radiation inhibited the binding affinity between HSP27 and apoptotic molecules, such as cytochrome c and PKC{delta}, and induced sensitization in vitro and in an in vivo xenografted nude mouse system. Structural analogs lacking only the carbonyl group in ZER, such as {alpha}-humulene (HUM) and 8-hydroxy-humulen (8-OH-HUM), did not affect normal cross-linking of HSP27 and did not induce radiosensitization. Conclusions: We suggest that altered cross-linking of HSP27 by ZER is a good strategy for abolishing HSP27-mediated resistance.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Clinical Release of an Online, Adaptive, Aperture-Based Image-Guided Radiotherapy Strategy in Intensity-Modulated Radiotherapy to Correct for Inter- and Intrafractional Rotations of the Prostate

Purpose: We developed and evaluated a correction strategy for prostate rotations using direct adaptation of segments in intensity-modulated radiotherapy (IMRT). Method and Materials: Implanted fiducials (four gold markers) were used to determine interfractional translations, rotations, and dilations of the prostate. We used hybrid imaging: The markers were automatically detected in two pretreatment planar X-ray projections; their actual position in three-dimensional space was reconstructed from these images at first. The structure set comprising prostate, seminal vesicles, and adjacent rectum wall was transformed accordingly in 6 degrees of freedom. Shapes of IMRT segments were geometrically adapted in a class solution forward-planning approach, derived within seconds on-site and treated immediately. Intrafractional movements were followed in MV electronic portal images captured on the fly. Results: In 31 of 39 patients, for 833 of 1013 fractions (supine, flat couch, knee support, comfortably full bladder, empty rectum, no intraprostatic marker migrations >2 mm of more than one marker), the online aperture adaptation allowed safe reduction of margins clinical target volume-planning target volume (prostate) down to 5 mm when only interfractional corrections were applied: Dominant L-R rotations were found to be 5.3 Degree-Sign (mean of means), standard deviation of means {+-}4.9 Degree-Sign , maximum at 30.7 Degree-Sign . Three-dimensional vector translations relative to skin markings were 9.3 {+-} 4.4 mm (maximum, 23.6 mm). Intrafractional movements in 7.7 {+-} 1.5 min (maximum, 15.1 min) between kV imaging and last beam's electronic portal images showed further L-R rotations of 2.5 Degree-Sign {+-} 2.3 Degree-Sign (maximum, 26.9 Degree-Sign ), and three-dimensional vector translations of 3.0 {+-}3.7 mm (maximum, 10.2 mm). Addressing intrafractional errors could further reduce margins to 3 mm. Conclusion: We demonstrated the clinical feasibility of an online adaptive image-guided, intensity-modulated prostate protocol on a standard linear accelerator to correct 6 degrees of freedom of internal organ motion, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of an Adaptive Strategy in Preoperative Radiochemotherapy for Rectal Cancer With Image-Guided Tomotherapy: Boosting the Dose to the Shrinking Tumor

Purpose: To investigate the feasibility of preoperative adaptive radiochemotherapy by delivering a concomitant boost to the residual tumor during the last 6 fractions of treatment. Methods and Materials: Twenty-five patients with T3/T4N0 or N+ rectal cancer were enrolled. Concomitant chemotherapy consisted of oxaliplatin 100 mg/m{sup 2} on days −14, 0, and +14, and 5-fluorouracil 200 mg/m{sup 2}/d from day −14 to the end of radiation therapy (day 0 is the start of radiation therapy). Radiation therapy consisted of 41.4 Gy in 18 fractions (2.3 Gy per fraction) with Tomotherapy to the tumor and regional lymph nodes (planning target volume, PTV) defined on simulation CT and MRI. After 9 fractions simulation CT and MRI were repeated for the planning of the adaptive phase: PTV{sub adapt} was generated by adding a 5-mm margin to the residual tumor. In the last 6 fractions a boost of 3.0 Gy per fraction (in total 45.6 Gy in 18 fractions) was delivered to PTV{sub adapt} while concomitantly delivering 2.3 Gy per fraction to PTV outside PTV{sub adapt}. Results: Three patients experienced grade 3 gastrointestinal toxicity; 2 of 3 showed toxicity before the adaptive phase. Full dose of radiation therapy, oxaliplatin, and 5-fluorouracil was delivered in 96%, 96%, and 88% of patients, respectively. Two patients with clinical complete response (cCR) refused surgery and were still cCR at 17 and 29 months. For the remaining 23 resected patients, 15 of 23 (65%) showed tumor regression grade 3 response, and 7 of 23 (30%) had pathologic complete response; 8 (35%) and 12 (52%) tumor regression grade 3 patients had ≤5% and 10% residual viable cells, respectively. Conclusions: An adaptive boost strategy is feasible, with an acceptable grade 3 gastrointestinal toxicity rate and a very encouraging tumor response rate. The results suggest that there should still be room for further dose escalation of the residual tumor with the aim of increasing pathologic complete response and/or cCR rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonisocentric Treatment Strategy for Breast Radiation Therapy: A Proof of Concept Study

Purpose: To propose a nonisocentric treatment strategy as a special form of station parameter optimized radiation therapy, to improve sparing of critical structures while preserving target coverage in breast radiation therapy. Methods and Materials: To minimize the volume of exposed lung and heart in breast irradiation, we propose a novel nonisocentric treatment scheme by strategically placing nonconverging beams with multiple isocenters. As its name suggests, the central axes of these beams do not intersect at a single isocenter as in conventional breast treatment planning. Rather, the isocenter locations and beam directions are carefully selected, in that each beam is only responsible for a certain subvolume of the target, so as to minimize the volume of irradiated normal tissue. When put together, the beams will provide an adequate coverage of the target and expose only a minimal amount of normal tissue to radiation. We apply the nonisocentric planning technique to 2 previously treated clinical cases (breast and chest wall). Results: The proposed nonisocentric technique substantially improved sparing of the ipsilateral lung. Compared with conventional isocentric plans using 2 tangential beams, the mean lung dose was reduced by 38% and 50% using the proposed technique, and the volume of the ipsilateral lung receiving ≥20 Gy was reduced by a factor of approximately 2 and 3 for the breast and chest wall cases, respectively. The improvement in lung sparing is even greater compared with volumetric modulated arc therapy. Conclusions: A nonisocentric implementation of station parameter optimized radiation therapy has been proposed for breast radiation therapy. The new treatment scheme overcomes the limitations of existing approaches and affords a useful tool for conformal breast radiation therapy, especially in cases with extreme chest wall curvature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗