Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Determination of the nonlinear thermo-optic coefficient of silicon nitride and oxide using an effective index method

There is little literature characterizing the temperature-dependent thermo-optic coefficient (TOC) for low pressure chemical vapor deposition (LPCVD) silicon nitride or plasma enhanced chemical vapor deposition (PECVD) silicon dioxide at temperatures above 300 K. In this study, we characterize these material TOC’s from approximately 300-460 K, yielding values of (2.51 ± 0.08) · 10 −5 K −1 for silicon nitride and (5.67 ± 0.53) · 10 −6 K −1 for silicon oxide at room temperature (300 K). We use a simplified experimental setup and apply an analytical technique to account for thermal expansion during the extraction process. We also show that the waveguide geometry and method used to determine the resonant wavelength have a substantial impact on the precision of our results, a fact which can be used to improve the precision of numerous ring resonator index sensing experiments.

36 MATERIALS SCIENCE↗

49 W carrier-envelope-phase-stable few-cycle 2.1 µm OPCPA at 10 kHz

We demonstrate a mid-infrared optical parametric chirped pulse amplifier (OPCPA), delivering 2.1 µm center wavelength pulses with 20 fs duration and 4.9 mJ energy at 10 kHz repetition rate. This self-seeded system is based on a kW-class Yb:YAG thin-disk amplifier driving a CEP stable short-wavelength-infrared (SWIR) generation and three consecutive OPCPA stages. Our SWIR source achieves an average power of 49 W, while still maintaining excellent phase and average power stability with sub-100 mrad carrier-envelope-phase-noise and 0.8% average power fluctuations. These parameters enable the OPCPA setup to drive attosecond pump probe spectroscopy experiments with photon energies in the water window.

47 OTHER INSTRUMENTATION↗

Multi-parameter distributed fiber optic sensing using double-Brillouin peak fiber in Brillouin optical time domain analysis

In this paper, we demonstrate a multi-parameter fiber sensing system based on stimulated Brillouin scattering in a double-Brillouin peak specialty fiber with enhanced Brillouin gain response. The amplitude level of the second Brillouin gain peak, which originated from the higher-order acoustic modes, has been improved with an approximately similar amplitude level to the first Brillouin gain peak from the fundamental acoustic mode. Compared to other multi-Brillouin peak fibers presented in the literature, the proposed fiber significantly reduces the measured Brillouin frequency shift error, thus improving strain and temperature accuracies. By utilizing the sensitivity values of the strain and temperature associated with each Brillouin gain spectrum (BGS) peak, a successful discriminative measurement of strain and temperature is performed with an accuracy of ±13 μɛ, and ±0.5 °C, respectively. The proposed double-Brillouin peak fiber appears to be a possible alternative to other multi-BGS peak fibers, for instance, large effective area fiber and dispersion compensating fibers, which are inherently accompanied by large measurement errors due to the weak Brillouin gain values originating from the higher-order acoustic modes. The demonstrated results show different strain and temperature coefficients of 47 kHz/µɛ, 1.15 MHz/°C for peak 1 and 51 kHz/µɛ, 1.37 MHz/°C for peak 2. Moreover, the enhanced BGS peak gains having nearly the same amplitude levels enable the discriminative measurement of strain and temperature. Such fibers in Brillouin interrogation eliminate the need for complex monitoring setups and reduce measurement errors. We recommend that for long-distance natural gas pipeline monitoring, where discriminative strain and temperature measurement is crucial, the proposed double-Brillouin peak fiber can be highly beneficial.

47 OTHER INSTRUMENTATION↗

Enhancement of terahertz fields in LiTaO 3 waveguides using a conical pulse front

The development of methods for the generation of strong ultrafast electromagnetic pulses in the terahertz (THz) spectral range has led to a surge of progress in nonlinear THz spectroscopy and THz control of molecular and collective responses. For spectroscopy in the 1-THz range, the submillimeter wavelengths and associated large spot sizes, large optical elements, and short distances between final focusing elements and samples can lead to cumbersome experimental setups that are incompatible with some sample environments. Here, we introduce a novel terahertz ring excitation (TREx) optical pumping geometry to generate superposing, focusing fields in planar THz waveguides made out of the electro-optic material lithium tantalate. High THz fields, >175 kV/cm, are generated and measured optically with no free-space THz propagation. The field level achieved by pumping with a sequence of concentric rings of excitation light exceeds by about 20× the result of a single cylindrically focused line of pump light that has been used routinely in previous work. The technique opens new prospects for compact waveguide-based linear and nonlinear THz spectroscopy and signal processing.

47 OTHER INSTRUMENTATION↗

Manufacturability-based optical design optimization for advanced Kirkpatrick–Baez X-ray focusing mirrors

The advanced Kirkpatrick–Baez (AKB) mirror setup is an effective and compelling solution to provide stable X-ray nano-focusing for synchrotron radiation or free-electron laser beamlines. We propose an AKB mirror design optimization approach to mitigate the difficulties associated with mirror fabrication by minimizing the total slope ranges of the four curved mirrors while achieving the expected focusing performance. In the optimization, we have considered geometry constraints to ensure the beam acceptance with the required clear aperture, the diffraction-limited focal size with the adequate numerical aperture, and the desired mirror gaps for adjustment and the necessary working distance for the sample stage. Additionally, practical constraints linked to mirror metrology and fabrication, such as mirror length limits and curvature uncertainty in measurement, are taken into account. Furthermore, progressive objective optimization eliminates the need for any initial guess, fully automating the AKB optimization process. This approach facilitates the development of an elegant Wolter-I or Wolter-III type AKB design solution that satisfies these multiple constraints. In cases where constraints cannot be simultaneously satisfied, the optimization results provide valuable insights into areas where trade-offs need to be considered. Simulations with ray tracing and wavefront propagation validate the optimized AKB design showing high tolerance to the beam incident angle.

36 MATERIALS SCIENCE↗

In situ characterization of two unknown ultrashort laser pulses using four-wave mixing in gas

Accurate characterization of two ultrashort laser pulses is of great interest in many ultrafast pump-probe experiments. We demonstrate a method based on four-wave mixing (FWM) in a gas which could be easily implemented into many existing pump-probe setups with minimal modifications for accurate, in situ characterization of both unknown pulses. This technique is tested on pairs of unknown pulses at wavelengths of 400/800 nm, and 266/400 nm. We measured the spectrogram of the pulse generated through FWM of the two unknown pulses by scanning the delay between two unknown pulses. The retrieval algorithm converges to accurately predict the intensity and the phase profiles of both unknown pulses with a trace error of < 1% and the accuracy is verified using an independent pulse characterization device.

Nambu, Noa (ORCID:0000000197303400)↗

Self-supervised physics-informed generative networks for phase retrieval from a single X-ray hologram

X-ray phase contrast imaging significantly improves the visualization of structures with weak or uniform absorption, broadening its applications across a wide range of scientific disciplines. Propagation-based phase contrast is particularly suitable for time- or dose-critical in vivo/in situ/operando (tomography) experiments because it requires only a single intensity measurement. However, the phase information of the wave field is lost during the measurement and must be recovered. Conventional algebraic and iterative methods often rely on specific approximations or boundary conditions that may not be met by many samples or experimental setups. In addition, they require manual tuning of reconstruction parameters by experts, making them less adaptable for complex or variable conditions. Here we present a self-learning approach for solving the inverse problem of phase retrieval in the near-field regime of Fresnel theory using a single intensity measurement (hologram). A physics-informed generative adversarial network is employed to reconstruct both the phase and absorbance of the unpropagated wave field in the sample plane from a single hologram. Unlike most state-of-the-art deep learning approaches for phase retrieval, our approach does not require paired, unpaired, or simulated training data. This significantly broadens the applicability of our approach, as acquiring or generating suitable training data remains a major challenge due to the wide variability in sample types and experimental configurations. The algorithm demonstrates robust and consistent performance across diverse imaging conditions and sample types, delivering quantitative, high-quality reconstructions for both simulated data and experimental datasets acquired at beamline P05 at PETRA III (DESY, Hamburg), operated by Helmholtz-Zentrum Hereon. Furthermore, it enables the simultaneous retrieval of both phase and absorption information.

36 MATERIALS SCIENCE↗

Overcoming energy limitation in post-compression of picosecond pulses by free beam propagation in air and temporal pulse splitting and recombining

Cryogenically cooled diode-pumped Yb:YAG has been demonstrated to efficiently generate pulses of >1 J energy and several picoseconds duration at a kilohertz repetition rate. Pulse broadening and post-compression techniques capable of operating at these high pulse energies will expand the use of these lasers in applications requiring shorter pulses. Towards this goal, we demonstrate the post-compression of 5.5 ps pulses with energy in the 0.1 J range by spectral broadening of self-collimated large area beams in air. In proof-of-principle experiments, pulses of 65 mJ energy from a cryogenically cooled Yb:YAG laser were compressed to 1.1 ps after 65 m propagation in a compact setup in which the beam was folded using flat mirrors. Further energy scaling was demonstrated by combining this spectral broadening technique with temporal pulse splitting and recombining. 120 mJ pulses were split into two pulses and coherently recombined with 85% efficiency after 50 m of propagation in air to yield 1.4 ps pulses.

High Energy Laser↗

Plasma mirror focal spot quality for glass and aluminum mirrors for laser pulses up to 20 ps

High-intensity short-pulse lasers are being pushed further as applications continue to demand higher laser intensities. Uses such as radiography and laser-driven particle acceleration require these higher intensities to produce the necessary x-ray and particle fluxes. Achieving these intensities, however, is limited by the damage threshold of costly optics and the complexity of target chambers. This is evidenced by the Advanced Radiographic Capability (ARC) short-pulse laser at the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory, producing four high-energy ≈1 kJ laser pulses at 30 ps pulse duration, being limited to an intensity of 10 18 W/cm 2 by the large focal spot size of ≈100 µm. Due to the setup complexity of NIF, changing the location of the final focusing parabola in order to improve the focal spot size is not an option. Therefore, this leads to the possible use of disposable ellipsoidal plasma mirrors (PMs) placed within the chamber, close to the target in an attempt to refocus the four ARC beams. However, the behavior of PMs at these relatively long pulse durations (tens of picoseconds) is not well characterized. The results from the COMET laser at the Jupiter Laser Facility carried out at 0.5 to 20 ps pulse durations on flat mirrors are presented as a necessary first step towards focusing curved mirrors. The findings show defocusing at longer pulse durations and higher intensities, with less degradation when using aluminum coated mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband polarization-entangled source for C+L-band flex-grid quantum networks

The rising demand for transmission capacity in optical networks has motivated steady interest in expansion beyond the standard C-band (1530–1565 nm) into the adjacent L-band (1565–1625 nm) for an approximate doubling of capacity in a single stroke. However, in the context of quantum networking, the L-band has yet to be fully leveraged with the suite of advanced tools for characterization and management available from classical lightwave communications. In this work, we demonstrate an ultrabroadband two-photon source integrating both C- and L-band wavelength-selective switches for complete control of spectral routing and allocation across 7.5 THz in a single setup. Polarization state tomography of all 150 pairs of 25-GHz-wide channels reveals an average fidelity of 0.98 and total distillable entanglement greater than 181 kebits/s. This source is explicitly designed for flex-grid optical networks and can facilitate optimal utilization of entanglement resources across the full C+L-band.

42 ENGINEERING↗

Light-field synthesizer based on multidimensional solitary states in hollow-core fibers

Few-cycle, long-wavelength sources for generating isolated attosecond soft x ray pulses typically rely upon complex laser architectures. Here, we demonstrate a comparatively simple setup for generating sub-two-cycle pulses in the short-wave infrared based on multidimensional solitary states in an N 2 O-filled hollow-core fiber and a two-channel light-field synthesizer. Due to the temporal phase imprinted by the rotational nonlinearity of the molecular gas, the redshifted (from 1.03 to 1.36 µm central wavelength) supercontinuum pulses generated from a Yb-doped laser amplifier are compressed from 280 to 7 fs using only bulk materials for dispersion compensation.

Truong, Tran-Chau (ORCID:0000000348940635)↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

Robust COTS objective for diffraction-limited, high-NA, long front working distance imaging

We present a robust objective lens optimized for applications requiring both high numerical aperture (NA) and long front working distance imaging, comprised of all commercial-off-the-shelf (COTS) spherical singlet lenses. Unlike traditional designs that require separate collimation and refocusing stages, our approach directly converges imaged light to the back focal plane using a single lens group. Our configuration corrects spherical aberrations and efficiently collects light to achieve diffraction-limited performance across a wide range of wavelengths while simplifying alignment and assembly. Using this approach, we design and construct an example objective lens that features a long front working distance of 61 mm and a clipped NA of 0.30 (limited by an aperture in our experimental setup). We experimentally verify that it achieves monochromatic diffraction-limited resolution at wavelengths from 375 nm to 866 nm without requiring replacement of the lenses or changing the inter-lens spacings, and its performance remains robust across a 46 mm range variation in total length (by adjusting mainly the back working distance). Additionally, we develop a quantitative method to measure the field of view (FOV) using an experimentally calibrated pinhole target. Under 397 nm illumination (i.e., from 40 Ca + ion fluorescence), the objective achieves a resolution of 0.87 μm with a 540 μm FOV. This robust, all-COTS, and versatile design is well-suited for a broad range of experiments, supporting high-precision measurements and exploring quantum phenomena.

Cui, Jiafeng [Oak Ridge National Laboratory (ORNL)↗

Beam combining of high-power terahertz lasers with semiconductor metasurface gratings

Spectral beam combining (SBC) of an array of single-mode lasers has the potential for realizing a chip-scale electrically tunable multispectral laser source without any moving parts and with emission at closely spaced discrete frequencies. Here, we demonstrate SBC of an array of single-mode THz quantum-cascade lasers (QCLs) with small frequency spacing. Semiconductor-based metasurface THz blazed gratings are developed for integration with QCLs in a compact cryocooler setup. Single-lobed beams of four QCLs emitting around 3.2 THz and spectrally separated by ~14 GHz are combined to achieve collinear propagation of spatially overlapped and collimated beams in the far field with ≲ 0.1° of pointing error. Peak optical power in the range 50–100 mW is detected from each of the QCLs after combining. The dense frequency spacing in our method provides a pathway to incorporate tens of QCLs on a chip to realize a high-power discretely tunable THz laser source for applications in THz spectroscopy.

Jia, Fei [Lehigh Univ., Bethlehem, PA (United Stat↗

Multifidelity computing for coupling full and reduced order models

Hybrid physics-machine learning models are increasingly being used in simulations of transport processes. Many complex multiphysics systems relevant to scientific and engineering applications include multiple spatiotemporal scales and comprise a multifidelity problem sharing an interface between various formulations or heterogeneous computational entities. To this end, we present a robust hybrid analysis and modeling approach combining a physics-based full order model (FOM) and a data-driven reduced order model (ROM) to form the building blocks of an integrated approach among mixed fidelity descriptions toward predictive digital twin technologies. At the interface, we introduce a long short-term memory network to bridge these high and low-fidelity models in various forms of interfacial error correction or prolongation. The proposed interface learning approaches are tested as a new way to address ROM-FOM coupling problems solving nonlinear advection-diffusion flow situations with a bifidelity setup that captures the essence of a broad class of transport processes.

59 BASIC BIOLOGICAL SCIENCES↗

Toward the validation of crowdsourced experiments for lightness perception

Crowdsource platforms have been used to study a range of perceptual stimuli such as the graphical perception of scatterplots and various aspects of human color perception. Given the lack of control over a crowdsourced participant’s experimental setup, there are valid concerns on the use of crowdsourcing for color studies as the perception of the stimuli is highly dependent on the stimulus presentation. Here, we propose that the error due to a crowdsourced experimental design can be effectively averaged out because the crowdsourced experiment can be accommodated by the Thurstonian model as the convolution of two normal distributions, one that is perceptual in nature and one that captures the error due to variability in stimulus presentation. Based on this, we provide a mathematical estimate for the sample size needed to produce a crowdsourced experiment with the same power as the corresponding in-person study. We tested this claim by replicating a large-scale, crowdsourced study of human lightness perception with a diverse sample with a highly controlled, in-person study with a sample taken from psychology undergraduates. Our claim was supported by the replication of the results from the latter. These findings suggest that, with sufficient sample size, color vision studies may be completed online, giving access to a larger and more representative sample. With this framework at hand, experimentalists have the validation that choosing either many online participants or few in person participants will not sacrifice the impact of their results.

97 MATHEMATICS AND COMPUTING↗