Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Extrapolation of scattering data to the negative-energy region. III. Application to the p – O 16 system

Using scattering data may give valuable information on the features of bound states, particularly on asymptotic normalization coefficients (ANCs), which, in contrast to binding energies, cannot be directly measured. The ANCs are fundamental nuclear characteristics that are important, for example, for evaluating cross sections of peripheral astrophysical nuclear reactions. One of the direct ways to extract ANCs from experimental data is the analytic continuation in the energy plane of the partial-wave elastic scattering amplitudes, obtained by the phase-shift analysis, to the pole corresponding to a bound state. Such a procedure, in contrast to the method of constructing optical potentials fitted to scattering data, allows one to circumvent an ambiguity problem associated with the model dependence of potentials. In this work the problem of analytic continuation of the scattering data to the negative-energy region to obtain information on ANCs of bound states is discussed. We explore two different methods of analytic continuations of the elastic scattering phase shifts of the p– 16 O system which is of interest for nuclear astrophysics. As a result, the ANCs for the ground 5/2 + and excited 1/2 + states of 17 F are determined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

s -wave scattering lengths for the 7 $\hbox{Be} +$ p system from an R -matrix analysis

The astrophysical S factor for the radiative proton capture reaction on Be 7 ( S 17 ) at low energies is affected by the s -wave scattering lengths. Herein, we report the measurement of elastic and inelastic scattering cross sections for the Be 7 + p system in the center-of-mass energy range 0.474–2.740 MeV and center-of-mass angular range 70 ° – 150 ° . A radioactive Be 7 beam produced at Oak Ridge National Laboratory's (ORNL) Holifield Radioactive Ion Beam Facility was accelerated and bombarded a thin polypropylene ( CH 2 ) n target. Scattered ions were detected in the segmented Silicon Detector Array. Using an R -matrix analysis of ORNL and Louvain-la-Neuve cross-section data, the s -wave scattering lengths for channel spins 1 and 2 were determined to be 17 . 34 – 1.33 + 1.11 and – 3 . 18 – 0.50 + 0.55 fm, respectively. The uncertainty in the s -wave scattering lengths reported in this work is smaller by a factor of 5–8 compared to the previous measurement, which may reduce the overall uncertainty in S 17 at zero energy. The level structure of B 8 is discussed based upon the results from this work. Evidence for the existence of 0 + and 2 + levels in B 8 at 1.9 and 2.21 MeV, respectively, is observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detecting nanometer-scale new forces with coherent neutron scattering

Significant effort has been devoted to searching for new fundamental forces of nature. At short length scales (below approximately 10 nm), the strongest experimental constraints come from neutron scattering from individual nuclei in gases. The leading experiments at longer length scales instead measure forces between macroscopic test masses. We propose a hybrid of these two approaches: scattering neutrons off of a target that has spatial structure at nanoscopic length scales. Such structures will give a coherent enhancement to small-angle scattering, where the new force is most significant. This can considerably improve the sensitivity of neutron scattering experiments for new forces in the 0.1–100 nm range. We discuss the backgrounds due to Standard Model interactions and a variety of potential target structures that could be used, estimating the resulting sensitivities. We show that, using only one day of beam time at a modern neutron scattering facility, our proposal has the potential to detect new forces as much as 2 orders of magnitude beyond current laboratory constraints at the appropriate length scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining dark matter-baryon scattering with linear cosmology

Here, we derive constraints on elastic scattering between baryons and dark matter using the cosmic microwave background (CMB) data from the Planck satellite and the Lyman- α forest data from the Sloan Digital Sky Survey. Elastic scattering provides baryons and dark matter to exchange momentum, affecting the dynamics of linear density perturbations in the early universe. We derive constraints to scattering cross sections of the form σ ∝ v n , allowing for a wide range of velocity dependencies with - 4 ≤ n ≤ 2 . We improve and correct previous estimates where they exist, including velocity-independent cross section as well as dark matter millicharge and electromagnetic dipole moments. Lyman- α forest data dominate the constraints for n > - 3 , where the improvement over CMB data alone can be several orders of magnitude. Dark matter-baryon scattering cannot affect the halo mass function on mass scales M > 10 12 M ⊙ . Our results imply, model independently, that a baryon in the halo of a galaxy like our own Milky Way does not scatter from dark matter particles during the age of the galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Shallow Bound States and Hints for Broad Resonances with Quark Content b ¯ c ¯ u d in B − D ¯ and B * − D ¯ Scattering from Lattice QCD

We present the first determination of the energy dependence of the B − D ¯ and B * − D ¯ isospin-0, S -wave scattering amplitudes both below and above the thresholds using lattice QCD, which allows us to investigate rigorously whether mixed bottom-charm b ¯ c ¯ u d tetraquarks exist as bound states or resonances. The scattering phase shifts are obtained using Lüscher’s method from the energy spectra in two different volumes. To ensure that no relevant energy level is missed, we use large, symmetric 7 × 7 and 8 × 8 correlation matrices that include, at both source and sink, B ( * ) − D ¯ scattering operators with the lowest three or four possible back-to-back momenta in addition to local b ¯ c ¯ u d operators. We fit the energy dependence of the extracted scattering phase shifts using effective-range expansions. We observe sharp peaks in the B ( * ) − D ¯ scattering rates close to the thresholds, which are associated with shallow bound states, either genuine or virtual, a few MeV or less below the B ( * ) − D ¯ thresholds. In addition, we find hints for resonances with masses of order 100 MeV above the thresholds and decay widths of order 200 MeV. Published by the American Physical Society 2024

Alexandrou, Constantia↗

Fluctuation X-ray scattering from nanorods in solution reveals weak temperature-dependent orientational ordering

Higher-order statistical analysis of X-ray scattering from dilute solutions of polydisperse goethite nanorods was performed and revealed structural information which is inaccessible by conventional small-angle scattering. For instance, a pronounced temperature dependence of the correlated scattering from suspension was observed. The higher-order scattering terms deviate from those expected for a perfectly isotropic distribution of particle orientations, demonstrating that the method can reveal faint orientational order in apparently disordered systems. The observation of correlated scattering from polydisperse particle solutions is also encouraging for future free-electron laser experiments aimed at extracting high-resolution structural information from systems with low particle heterogeneity.

36 MATERIALS SCIENCE↗

Learning to Predict Material Structure from Neutron Scattering Data

Understanding structural properties of materials and how they relate to its atomic structure, while extremely challenging, is a key scientific quest that has dominated the landscape of materials research for decades. Neutron and X-ray scattering is a state-of-the-art method to investigate material structure on the atomic scale. Traditional methods of processing neutron scattering data to decipher the structure of target materials have relied on computing scattering patterns using physics-based forward models and comparing them with experimentally gathered scattering profiles within a computationally expensive optimization loop. Here, we report an initial design of a data-driven machine learning pipeline for material structure prediction that is computationally faster (once trained) and potentially more accurate. We describe the architecture of the ML pipeline and a preliminary benchmarking study of shallow machine learning models in terms of their prediction accuracy and limitations. We show that material structure prediction from neutron scattering data using shallow learning models is feasible to within 90% prediction accuracy for certain classes of materials but deeper models are required for more general material structure predictions.

Garcia Cardona, Cristina↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WAXS fat subtraction model to estimate differential linear scattering coefficients of fatless breast tissue: Phantom materials evaluation

Purpose: Develop a method to subtract fat tissue contributions to wide-angle x-ray scatter (WAXS) signals of breast biopsies in order to estimate the differential linear scattering coefficients μ{sub s} of fatless tissue. Cancerous and fibroglandular tissue can then be compared independent of fat content. In this work phantom materials with known compositions were used to test the efficacy of the WAXS subtraction model. Methods: Each sample 5 mm in diameter and 5 mm thick was interrogated by a 50 kV 2.7 mm diameter beam for 3 min. A 25 mm{sup 2} by 1 mm thick CdTe detector allowed measurements of a portion of the θ = 6° scattered field. A scatter technique provided means to estimate the incident spectrum N{sub 0}(E) needed in the calculations of μ{sub s}[x(E, θ)] where x is the momentum transfer argument. Values of μ{sup ¯}{sub s} for composite phantoms consisting of three plastic layers were estimated and compared to the values obtained via the sum μ{sup ¯}{sub s}{sup ∑}(x)=ν{sub 1}μ{sub s1}(x)+ν{sub 2}μ{sub s2}(x)+ν{sub 3}μ{sub s3}(x), where ν{sub i} is the fractional volume of the ith plastic component. Water, polystyrene, and a volume mixture of 0.6 water + 0.4 polystyrene labelled as fibphan were chosen to mimic cancer, fat, and fibroglandular tissue, respectively. A WAXS subtraction model was used to remove the polystyrene signal from tissue composite phantoms so that the μ{sub s} of water and fibphan could be estimated. Although the composite samples were layered, simulations were performed to test the models under nonlayered conditions. Results: The well known μ{sub s} signal of water was reproduced effectively between 0.5 < x < 1.6 nm{sup −1}. The μ{sup ¯}{sub s} obtained for the heterogeneous samples agreed with μ{sup ¯}{sub s}{sup ∑}. Polystyrene signals were subtracted successfully from composite phantoms. The simulations validated the usefulness of the WAXS models for nonlayered biopsies. Conclusions: The methodology to measure μ{sub s} of homogeneous samples was quantitatively accurate. Simple WAXS models predicted the probabilities for specific x-ray scattering to occur from heterogeneous biopsies. The fat subtraction model can allow μ{sub s} signals of breast cancer and fibroglandular tissue to be compared without the effects of fat provided there is an independent measurement of the fat volume fraction ν{sub f}. Future work will consist of devising a quantitative x-ray digital imaging method to estimate ν{sub f} in ex vivo breast samples.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-A-18C-06: A Scatter Elimination Scheme for Cone Beam CT Using An Oscillating Narrow Beam

Purpose: While cone beam CT (CBCT) has been widely used in image guided radiation therapy, its low image quality, primarily caused by scattered x-rays, hinders advanced clinical applications, e.g., CBCT based on-line adaptive re-planning. We propose in this abstract a new scheme called oscillating narrow beam CBCT (ONB-CBCT) to eliminate scatter signals. Methods: ONB-CBCT consists of two major components. 1) Oscillating narrow beam (ONB) scan and 2) partitioned flat panel containing multiple individual detector strips and their own readouts. Both the beam oscillation and detector partition are along the superior-inferior (SI) direction. During data acquisition, at a given projection, the narrow beam sweep through the detector region, and different portions of the detector acquires projection data in synchrony with the narrow beam. ONB can be generated by a rotating slit collimator design with conventional tube with single focal spot, or by directly using a new source with multiple focal spots. A proof-of-principle study via Monte Carlo simulation is conducted to demonstrate the feasibility of ONB-CBCT. Results: As the beam becomes narrower, more and more scatter signals are eliminated. For the case with a bowtie filter and using 15 ONBs, the maximum and the average intensity error due to scatter are below 20 and 10 HU, respectively. Conclusion: ONB yields a narrowed exposure field at each snapshot and hence an inherently negligible scatter effect. Meanwhile, the individualized detector units guarantee high frame rate detection and hence a same large volume coverage as that in conventional CBCT. In summary, ONB-CBCT is a promising design to achieve high-quality CBCT imaging. This study is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-206-04: Iterative CBCT Scatter Shading Correction Without Prior Information

Purpose: To estimate and remove the scatter contamination in the acquired projection of cone-beam CT (CBCT), to suppress the shading artifacts and improve the image quality without prior information. Methods: The uncorrected CBCT images containing shading artifacts are reconstructed by applying the standard FDK algorithm on CBCT raw projections. The uncorrected image is then segmented to generate an initial template image. To estimate scatter signal, the differences are calculated by subtracting the simulated projections of the template image from the raw projections. Since scatter signals are dominantly continuous and low-frequency in the projection domain, they are estimated by low-pass filtering the difference signals and subtracted from the raw CBCT projections to achieve the scatter correction. Finally, the corrected CBCT image is reconstructed from the corrected projection data. Since an accurate template image is not readily segmented from the uncorrected CBCT image, the proposed scheme is iterated until the produced template is not altered. Results: The proposed scheme is evaluated on the Catphan©600 phantom data and CBCT images acquired from a pelvis patient. The result shows that shading artifacts have been effectively suppressed by the proposed method. Using multi-detector CT (MDCT) images as reference, quantitative analysis is operated to measure the quality of corrected images. Compared to images without correction, the method proposed reduces the overall CT number error from over 200 HU to be less than 50 HU and can increase the spatial uniformity. Conclusion: An iterative strategy without relying on the prior information is proposed in this work to remove the shading artifacts due to scatter contamination in the projection domain. The method is evaluated in phantom and patient studies and the result shows that the image quality is remarkably improved. The proposed method is efficient and practical to address the poor image quality issue of CBCT images. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917).

60 APPLIED LIFE SCIENCES↗

SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads to the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation therapy. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)

60 APPLIED LIFE SCIENCES↗

TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Direct exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-07: A Planning CT-Guided Scatter Artifact Correction Method for CBCT Images

Purpose: Cone beam computed tomography (CBCT) imaging is on increasing demand for high-performance image-guided radiotherapy such as online tumor delineation and dose calculation. However, the current CBCT imaging has severe scatter artifacts and its current clinical application is therefore limited to patient setup based mainly on the bony structures. This study’s purpose is to develop a CBCT artifact correction method. Methods: The proposed scatter correction method utilizes the planning CT to improve CBCT image quality. First, an image registration is used to match the planning CT with the CBCT to reduce the geometry difference between the two images. Then, the planning CT-based prior information is entered into the Bayesian deconvolution framework to iteratively perform a scatter artifact correction for the CBCT mages. This technique was evaluated using Catphan phantoms with multiple inserts. Contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR), and the image spatial nonuniformity (ISN) in selected volume of interests (VOIs) were calculated to assess the proposed correction method. Results: Post scatter correction, the CNR increased by a factor of 1.96, 3.22, 3.20, 3.46, 3.44, 1.97 and 1.65, and the SNR increased by a factor 1.05, 2.09, 1.71, 3.95, 2.52, 1.54 and 1.84 for the Air, PMP, LDPE, Polystryrene, Acrylic, Delrin and Teflon inserts, respectively. The ISN decreased from 21.1% to 4.7% in the corrected images. All values of CNR, SNR and ISN in the corrected CBCT image were much closer to those in the planning CT images. The results demonstrated that the proposed method reduces the relevant artifacts and recovers CT numbers. Conclusion: We have developed a novel CBCT artifact correction method based on CT image, and demonstrated that the proposed CT-guided correction method could significantly reduce scatter artifacts and improve the image quality. This method has great potential to correct CBCT images allowing its use in adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

FINITE-ELEMENT DISTORED WAVE BORN APPROXIMATION FOR SURFACE SCATTERING

FE-DWBA is a software package that computes the x-ray scattering patterns of objects that locate on a surface or buried next to a surface, such as the nano-circuits and nano-patterns of the mask used in the extreme ultraviolet lithography. It can incorporate the dynamical scattering effect (photons scattered multiple times), which is predominant in surface scattering and yield high-fidelity scattering patterns. The application includes surface imaging using x-rays, and critical dimension determination for semiconductor manufacturing.

HU, MAIOQI↗

Measurement of Sauter mean diameter in diesel sprays using a scattering–absorption measurement ratio technique

A new diagnostic for the quantification of Sauter mean diameter in high-pressure fuel sprays has been recently developed using combined optical and X-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from X-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the scattering–absorption measurement ratio, quantifies two-dimensional distributions of path-integrated Sauter mean diameter, enabling the construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The methodology for quantification of Sauter mean diameter distributions using the scattering–absorption measurement ratio technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector; however, a more detailed treatment of measurement uncertainties has been needed. In this work, we present a summary of the various sources of measurement uncertainty in the scattering–absorption measurement ratio diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified Sauter mean diameter. The spatially resolved Sauter mean diameter measurements that result from the scattering–absorption measurement ratio diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine computational fluid dynamics codes. Careful evaluation and quantification of measurement uncertainties are important to support accurate model validation and to ensure the development of more predictive spray models.

42 ENGINEERING↗

Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments

Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.

42 ENGINEERING↗

Light scattering from laser induced pit ensembles on high power laser optics

Far-field light scattering characteristics from randomly arranged shallow Gaussian-like shaped laser induced pits, found on optics exposed to high energy laser pulses, is studied. Closed-form expressions for the far-field intensity distribution and scattered power are derived for individual pits and validated using numerical calculations of both Fourier optics and FDTD solutions to Maxwell’s equations. It is found that the scattered power is proportional to the square of the pit width and approximately also to the square of the pit depth, with the proportionality factor scaling with pit depth. As a result, the power scattered from shallow pitted optics is expected to be substantially lower than assuming complete scattering from the total visible footprint of the pits.

42 ENGINEERING↗