Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A high solids field-to-fuel research pipeline to identify interactions between feedstocks and biofuel production

Abstract Background Environmental factors, such as weather extremes, have the potential to cause adverse effects on plant biomass quality and quantity. Beyond adversely affecting feedstock yield and composition, which have been extensively studied, environmental factors can have detrimental effects on saccharification and fermentation processes in biofuel production. Only a few studies have evaluated the effect of these factors on biomass deconstruction into biofuel and resulting fuel yields. This field-to-fuel evaluation of various feedstocks requires rigorous coordination of pretreatment, enzymatic hydrolysis, and fermentation experiments. A large number of biomass samples, often in limited quantity, are needed to thoroughly understand the effect of environmental conditions on biofuel production. This requires greater processing and analytical throughput of industrially relevant, high solids loading hydrolysates for fermentation, and led to the need for a laboratory-scale high solids experimentation platform. Results A field-to-fuel platform was developed to provide sufficient volumes of high solids loading enzymatic hydrolysate for fermentation. AFEX pretreatment was conducted in custom pretreatment reactors, followed by high solids enzymatic hydrolysis. To accommodate enzymatic hydrolysis of multiple samples, roller bottles were used to overcome the bottlenecks of mixing and reduced sugar yields at high solids loading, while allowing greater sample throughput than possible in bioreactors. The roller bottle method provided 42–47% greater liquefaction compared to the batch shake flask method for the same solids loading. In fermentation experiments, hydrolysates from roller bottles were fermented more rapidly, with greater xylose consumption, but lower final ethanol yields and CO 2 production than hydrolysates generated with shake flasks. The entire platform was tested and was able to replicate patterns of fermentation inhibition previously observed for experiments conducted in larger-scale reactors and bioreactors, showing divergent fermentation patterns for drought and normal year switchgrass hydrolysates. Conclusion A pipeline of small-scale AFEX pretreatment and roller bottle enzymatic hydrolysis was able to provide adequate quantities of hydrolysate for respirometer fermentation experiments and was able to overcome hydrolysis bottlenecks at high solids loading by obtaining greater liquefaction compared to batch shake flask hydrolysis. Thus, the roller bottle method can be effectively utilized to compare divergent feedstocks and diverse process conditions.

09 BIOMASS FUELS↗

Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Rapid monitoring of biomass conversion processes using techniques such as near-infrared (NIR) spectroscopy can be substantially quicker and less labor-, resource-, and energy-intensive than conventional measurement techniques such as gas or liquid chromatography (GC or LC) due to the lack of solvents and preparation methods, as well as removing the need to transfer samples to an external lab for analytical evaluation. The purpose of this study was to determine the feasibility of rapid monitoring of a biomass conversion process using NIR spectroscopy combined with multivariate statistical modeling, and to examine the impact of (1) subsetting the samples in the original dataset by process location and (2) reducing the spectral range used in the calibration model on model performance. We develop multivariate calibration models for the concentrations of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids at multiple points in a biomass conversion process which produces and then purifies XOS compounds from sugar cane bagasse. A single model using samples from multiple locations in the process stream showed acceptable performance as measured by standard statistical measures. However, compared to the single model, we show that separate models built by segregating the calibration samples according to process location show improved performance. We also show that combining an understanding of the sample spectra with simple multivariate analysis tools can result in a calibration model with a substantially smaller spectral range that provides essentially equal performance to the full-range model. We demonstrate that real-time monitoring of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids concentration at multiple points in a process stream using NIR spectroscopy coupled with multivariate statistics is feasible. Segregation of sample populations by process location improves model performance. Models using a reduced spectral range containing the most relevant spectral signatures show very similar performance to the full-range model, reinforcing the importance of performing robust exploratory data analysis before beginning multivariate modeling.

09 BIOMASS FUELS↗

RNA Splicing Events in Circulation Distinguish Individuals With and Without New-onset Type 1 Diabetes

Context: Alterations in RNA splicing may influence protein isoform diversity that contributes to or reflects the pathophysiology of certain diseases. Whereas specific RNA splicing events in pancreatic islets have been investigated in models of inflammation in vitro, how RNA splicing in the circulation correlates with or is reflective of type 1 diabetes (T1D) disease pathophysiology in humans remains unexplored. Objective: To use machine learning to investigate if alternative RNA splicing events differ between individuals with and without new-onset T1D and to determine if these splicing events provide insight into T1D pathophysiology. Methods: RNA deep sequencing was performed on whole blood samples from 2 independent cohorts: a training cohort consisting of 12 individuals with new-onset T1D and 12 age- and sex-matched nondiabetic controls and a validation cohort of the same size and demographics. Machine learning analysis was used to identify specific isoforms that could distinguish individuals with T1D from controls. Results: Distinct patterns of RNA splicing differentiated participants with T1D from unaffected controls. Notably, certain splicing events, particularly involving retained introns, showed significant association with T1D. Machine learning analysis using these splicing events as features from the training cohort demonstrated high accuracy in distinguishing between T1D subjects and controls in the validation cohort. Gene Ontology pathway enrichment analysis of the retained intron category showed evidence for a systemic viral response in T1D subjects. Conclusion: Alternative RNA splicing events in whole blood are significantly enriched in individuals with new-onset T1D and can effectively distinguish these individuals from unaffected controls. Further, our findings also suggest that RNA splicing profiles offer the potential to provide insights into disease pathogenesis.

60 APPLIED LIFE SCIENCES↗

Single-shot imaging with randomized structured illumination at a free electron laser

Stroboscopic nanoscale imaging with free electron laser light is revolutionizing our understanding of fast dynamics in heterogeneous systems. The short wavelength of X-ray and extreme ultraviolet radiation makes it possible to achieve nanoscale resolution, while resonance with atomic transitions gives access to electronic and magnetic degrees of freedom. Here, we report on our implementation of a recently developed imaging method, randomized probe imaging, at a free electron laser. The advantage of randomized probe imaging over existing methods is its compatibility with extended and strongly scattering samples. Our implementation delivers robust single-shot reconstructions at up to a full-pitch resolution of 400 nm over a field of view with a 40 µm diameter. We also demonstrate single-shot imaging of magnetic domain structures using circular dichroism at resonance, paving the way to future time-resolved studies of magnetic dynamics, shock physics, and the dynamics of collective electronic phases.

47 OTHER INSTRUMENTATION↗

Ultrabroadband two-dimensional electronic spectroscopy in the pump–probe geometry using conventional optics

We report ultrabroadband two-dimensional electronic spectroscopy (2D ES) measurements obtained in the pump–probe geometry using conventional optics. A phase-stabilized Michelson interferometer provides the pump-pulse delay interval,τ 1 , necessary to obtain the excitation-frequency dimension. Spectral resolution of the probe beam provides the detection-frequency dimension,ω 3 . The interferometer incorporates active phase stabilization via a piezo stage and feedback from interference of a continuous-wave reference laser detected in quadrature. To demonstrate the method, we measured a well-characterized laser dye sample and obtained the known peak structure. The vibronic peaks are modulated as a function of the waiting time,τ 2 , by vibrational wave packets. The interferometer simplifies ultrabroadband 2D ES measurements and analysis.

Optics↗

Holographic Lithography for Industrial Nanomanufacturing

The participant constructed interference lithography experiments on their prototype of a coordinated holographic industrial-scale electromagnetic lithography (CHISEL) tool. These experiments involved generating several laser beams and interfering them in photosensitive materials, whereupon subsequent development resulted in micro- and nano-structured samples. We characterized these samples using scanning electron microscopy and various optical interrogation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total Moisture Analysis of Salts by Dissolution

This report discusses recent efforts within TA-48 in developing a robust, defensible, and straightforward procedure for determining the moisture content of alkali and alkaline metal halide salts utilizing a total dissolution Karl-Fischer titration method. Utilizing statistical analysis of blank and dissolved salt samples, we determine a (3 sigma) detection limit of 67 micrograms H 2 O/g salt, and a (10 sigma) quantification limit of 160 micrograms H 2 O/g salt. Several salts are analyzed, and suggestions for future efforts are given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Draft Rules for Alloy 617 Creep-Fatigue Design Using an EPP+SMT Approach

The report describes an improved new creep-fatigue design method for structural components in high temperature nuclear service. The new method uses an integrated elastic-perfectly plastic (EPP) analysis and Simplified Model Test (SMT) approach that greatly simplifies the design process by avoiding the separate evaluation of creep and fatigue damages and eliminating the requirement of stress classification. The report includes draft design rules, presented in a format compatible with an ASME nuclear Code Case, as well as a commentary on the rules and the validation of the rules using pressurized SMT (p-SMT) test data. Areas of potential improvement have been identified for further evaluation. The report also develops EPP+SMT design charts for Alloy 617 at temperatures between 800°C and 950°C by extrapolating high strain range, short hold test data to low strain range and long hold times, typical for structural components in high temperature nuclear service. The design charts are currently limited to 10,000 cycles to avoid excessive extrapolation outside the test database. More robust alternate extrapolation procedures will be considered in future work. The report includes several verification problems comparing the new EPP+SMT design method with current ASME creep-fatigue design methods. The comparison demonstrates that the EPP+SMT method significantly reduces the over-conservatism in current methods. Finally, the report includes a fully-documented sample problem with multiple load cases detailing the application of proposed EPP+SMT design rules.

36 MATERIALS SCIENCE↗

High-Performance Piezoelectric MEMS Manufacturing & Application on Micro Power Generators (CRADA Final Report)

This project aimed to develop and characterize a micro-fabrication technology for wafer-scale heterogeneous integration of bulk piezoelectric materials on silicon substrates that could enable manufacturing of high-performance micro transducers. Typical technical challenges for piezoelectric microfabrication technologies are high-temperature processing, non-uniform film quality, and low process repeatability, which will be addressed during this project. Progress was made on preliminary research towards development of a technology platform that will enable a new micro-fabrication process to provide the highest electromechanical coupling among any other thin/thick-film deposition methods available today. This work has tested and characterized samples that we hope will further our goal of refining and enabling existing micro transducers to achieve unprecedentedly high performance. This project focused solely on the characterization of the proposed microfabrication process technology, and it did not consist of design or manufacturing of new transducers, such as sensors, actuators or energy harvesters based on this fabrication process. Future work will be aimed at the research and development of process steps specifically to enable integration of on-chip electronics with piezoelectric materials.

36 MATERIALS SCIENCE↗

Mercury Speciation During Vitrification of LAW

n this work, laboratory and engineering-scale tests were conducted that mimic the reactive environment of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) low activity waste (LAW) melter and off-gas system in order to assess the speciation of mercury at select points in the processing system. The experimental protocols, test equipment, feed materials used, and rationale for testing are detailed in the Test Plan for this work. Particular attention was paid to the amount and speciation of mercury in submerged bed scrubber (SBS) solutions, which are intended to be recycled back to the melter feed at the WTP. Results are presented from detailed mercury analysis of these solutions using Environmental Protection Agency (EPA) Method 1630 and modifications to this method for dimethyl mercury and methyl mercury as well as EPA Method 1631 and modifications to this method for total, dissolved, elemental, suspended, and ionic mercury. Testing was conducted in two separate sets of experiments: (1) One set of tests (crucible-scale furnace tests) that involved heating small batches of mercury-spiked melter feed in crucibles to determine the amount of mercury retained in the glass and the species of mercury in the exhaust gases; (2) A second set of tests (DM10 melter tests) was planned that involved creating LAW melter plenum gas compositions using the DM10 melter system, injecting mercury into the off-gas stream, and passing that stream though a reactor that simulates various plenum gas conditions. Operational issues led to the need to use one of the VSL DM100 melters in place of the planned DM10 melter for these tests. The speciation of mercury after exposure to those conditions was monitored. In both sets of tests, the exhaust gases were run through a scrubber that was intended to mimic the LAW SBS in order to determine how much of the mercury exiting the melter would be retained in the primary off-gas system fluids and in what form. After passing through the SBS, the exhaust stream was analyzed to determine particulate, ionic, elemental, and total mercury passing downstream of the SBS. In tests employing gases derived from the DM100 melter that were spiked with elemental mercury, the processing system provided gas temperatures and residence times that are representative of the WTP LAW vitrification system in order to assess the effect of those conditions on mercury speciation. The Decontamination Factor (DF) across the system in the tests with mercury-spiked DM100 melter exhaust was determined using the analytical data from EPA Method 30B (Fluegas Adsorption Mercury Speciation (FAMS TM )) exhaust samples and the amount of mercury detected in the SBS solutions. Mercury species used in melter feed crucible scale tests were divalent (chloride and iodide), monovalent (chloride and fluoride), and elemental mercury. Individual tests included only a single form of mercury in the feed. The results for total mercury mass balances in the crucible tests are also presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-Gated Raman Spectroscopy (Intern Final Report)

Time-gated Raman spectroscopy is a powerful tool for rapid non-destructive analysis of chemical compounds, particularly when combined with other investigative methods. Time-gating the signal obtained from a sample during Raman spectroscopy allows for the removal of background emission and black body radiation, improving clarity and accuracy of scans. The main objectives of this project were to prove the lab’s time-gated Raman spectroscopy system works as proof of concept and to make select improvements to the in-house LabVIEW software used to run the time-gated system. This time-gated system will be added to the CTK’s TAP reactors in the future, but this is out of the scope of this internship project. This research is important, as understanding the mechanisms behind catalysts leads to designing better systems/materials and the perfection of catalysts, and energy-efficient chemical manufacturing is key when designing a greener future. The research for this project was done with samples at both ambient conditions in sample holders and at operando conditions (i.e., high temperature, unsteady-state) inside a small-volume chemical reactor. Numerous spectro-kinetic scans of the catalysts were obtained, but the advanced dynamics of these systems are still being interpreted. There is data that demonstrates that the time-gated system is correctly rejecting emission from samples, and one can observe real-time changes in the signal from the sample, due to coking or changes induced by redox chemistry. Chemical manufacturers and the planet are the main beneficiaries of catalysis research, as better catalysts will reduce carbon emissions.

36 MATERIALS SCIENCE↗

PE1 Site Characterization: Data Documentation on Geologic and Hydrologic Lab Testing

This data documentation report describes geologic and hydrologic laboratory analysis and data collected in support of site characterization of the Physical Experiment 1 (PE1) testbed, Aqueduct Mesa, Nevada. The documentation includes a summary of laboratory tests performed, discussion of sample selection for assessing heterogeneity of various testbed properties, methods, and results per data type.

58 GEOSCIENCES↗

Inconel 718 Oxide Coating Process for Mu2e Target Redesign

A method of growing an oxide coating on Inconel 718 samples was investigated to increase the emissivity of the redesigned Inconel Mu2e production target. Microscopy and emissivity measurements of a range of samples indicate excellent performance.

Williams, J. [Fermilab]↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗

Mitigation of Cu-Induced Grain Boundary Sensitization in Steel Wire Rods Through a Desensitization Heat Treatment

Steel wire rods are essential for manufacturing high-strength steel tire cords. Yet, the presence of residual copper (Cu) in recycled steel can cause grain-boundary sensitization, embrittlement, and deterioration of the mechanical performance of the final product. This study introduces a desensitization heat treatment step designed to redistribute Cu away from austenite grain boundaries after sensitization occurs. The treatment consists of a 10 min dwell at 1000 °C in a 5%H 2 -Ar reducing atmosphere followed by quench. The temperature and hold time were selected based on diffusion calculations to promote solid-state back diffusion of Cu without altering grain morphology. Experimental validation showed that the dwell step reduced the length of Cu-rich sensitized zones of steel wire rod samples containing 0.21 wt.% Cu by approximately 89% and restored the mechanical properties to nearly 95–98% relative to low-Cu baseline steel (0.01 wt.% Cu). Compared with sensitized and as-obtained samples, these results highlight the effectiveness of the proposed method in improving both the microstructure and tensile performance of recycled steel wire rods, enabling their potential application in tire manufacturing.

copper↗

Forward Modeling the Orbits of Companions to Pulsating Stars from Their Light Travel Time Variations

Mutual gravitation between a pulsating star and an orbital companion leads to a time-dependent variation in path length for starlight traveling to Earth. These variations can be used for coherently pulsating stars, such as the δ Scuti variables, to constrain the masses and orbits of their companions. Observing these variations for δ Scuti stars has previously relied on subdividing the light curve and measuring the average pulsation phase in equally sized subdivisions, which leads to undersampling near periapsis. We introduce a new approach that simultaneously forward models each sample in the light curve and show that this method improves upon current sensitivity limits—especially in the case of highly eccentric and short-period binaries. We find that this approach is sensitive enough to observe Jupiter mass planets around δ Scuti stars under ideal conditions, and use gravity-mode pulsations in the subdwarf B star KIC 7668647 to detect its companion without radial velocity data. We further provide robust detection limits as a function of the signal-to-noise ratio of the pulsation mode and determine that the minimum detectable light travel time amplitude for a typical Kepler δ Scuti is around 2 s. This new method significantly enhances the application of light travel time variations to detecting short-period binaries with pulsating components, and pulsating A-type exoplanet host stars, especially as a tool for eliminating false positives.

79 ASTRONOMY AND ASTROPHYSICS↗

The Twins Embedding of Type Ia Supernovae. II. Improving Cosmological Distance Estimates

We show how spectra of Type Ia supernovae (SNe Ia) at maximum light can be used to improve cosmological distance estimates. In a companion article, we used manifold learning to build a three-dimensional parameterization of the intrinsic diversity of SNe Ia at maximum light that we call the "Twins Embedding."In this article, we discuss how the Twins Embedding can be used to improve the standardization of SNe Ia. With a single spectrophotometrically calibrated spectrum near maximum light, we can standardize our sample of SNe Ia with an rms of 0.101 0.007 mag, which corresponds to 0.084 0.009 mag if peculiar velocity contributions are removed and to 0.073 0.008 mag if a larger reference sample were obtained. Our techniques can standardize the full range of SNe Ia, including those typically labeled as peculiar and often rejected from other analyses. We find that traditional light-curve width + color standardization such as SALT2 is not sufficient. The Twins Embedding identifies a subset of SNe Ia, including, but not limited to, 91T-like SNe Ia whose SALT2 distance estimates are biased by 0.229 0.045 mag. Standardization using the Twins Embedding also significantly decreases host-galaxy correlations. We recover a host mass step of 0.040 0.020 mag compared to 0.092 0.026 mag for SALT2 standardization on the same sample of SNe Ia. These biases in traditional standardization methods could significantly impact future cosmology analyses if not properly taken into account.

79 ASTRONOMY AND ASTROPHYSICS↗