Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Photometric and polarimetric analysis of samples of lunar surface material returned by the Luna 16 automatic station

Polarimetric properties were determined for the L-16-19-1-116 samples, weighing 0.087 g. The measurements were made for five wavelengths between 3540 and 5850 AU. In addition, the normal albedo was determined for each of these wavelengths. The albedo for the measured sample was slightly lower than for the typical material of the dark lunar maria and in addition, there was a well developed branch of negative polarization, which resembles the branch obtained for carbonaceous chondrites crushed into powder, and the branch obtained for the powders of several terrestrial basaltic and ultrabasic rocks.

Dollfus, A.↗

Magnetic properties of lunar samples returned by Luna 16 automatic station

Results of measuring the specific magnetic susceptibility of regolith are presented. The data indicate that regolith samples from the Sea of Tranquillity and the Sea of Fertility are similar in order of magnitude of the specific magnetic susceptibility. Several stony meteorites of subgroup L have a similar value of this quantity. After comparison with artificial analogs, it can be concluded that the bulk content of ferromagnetic minerals in regolith samples is 3 to 4 percent.

Gorshkov, E. S.↗

Skylab program payload integration. TO27 sample array

The objective of the TO27 sample array was to determine the change in optical properties of various transmissive windows, mirrors, and diffraction gratings caused by the deposition of contaminants found about the orbital assembly. The expected information to be obtained from the total TO27 sample array program is as follows: (1) effect of space contaminants on transmittance, reflectance, grating efficiency, and polarization; (2) variations in deposition of contaminants due to substrate, solar radiation, period of exposure, direction of exposure, and geometry effects; (3) identification of contaminants and source of evolution; (4) time of contaminant evolution and lingering time; and (5) guidelines for a model of spacecraft contamination.

Muscari, J. A.↗

Apparatus for microbiological sampling

An automatic apparatus is described for microbiologically sampling surface using a cotton swab which eliminates human error. The apparatus includes a self-powered transport device, such as a motor-driven wheeled cart, which mounts a swabbing motor drive for a crank arm which supports a swab in the free end thereof. The swabbing motor is pivotably mounted and an actuator rod movable responsive to the cart traveling a predetermined distance provides lifting of the swab from the surface being sampled and reversal of the direction of travel of the cart.

Wilkins, J. R.↗

Petrological studies on lunar rock samples

Petrological studies were made on Apollo 14, 15, 16, and 17 lunar samples. High-pressure melting experiments were conducted, along with electron microprobe analyses. The composition of the samples is reported.

Kushiro, I.↗

Lunar sample analysis

Previous studies have shown that very small amounts of absorbed volatiles only removed by outgassing in high vacuum and elevated temperatures-drastically increase the internal friction in terrestrial analogs of lunar basalt. Recently room temperature Q values as high as 2000 were achieved by thorough outgassing procedures in 10 to the 8th power torr. Results are presented on Q measurements for lunar rock 70215.85, along with some data on the effect on Q of a variety of gases. Data show that substantially greater increases in Q are obtainable in a lunar rock sample than in the terrestrial analog samples studied, and that in addition to H2O other gases also can make non-negligible contributions to the internal friction.

Tittmann, B. R.↗

Summary of the proceedings of the Mars Surface Sample Return Symposium

A summary is made of various technical and scientific aspects of a Mars surface sample return mission. Particular attention was focused on the question of back contamination. Data are also given on problems inherent in the back contamination issue and return sample mission; areas where additional research is needed were pointed out. Quarantine procedures, safety measures, and sterilization effects on organic-inorganic data, and biological problems were also dealt with.

Devincenzi, D. L.↗

Melting behavior and phase relations of lunar samples

Cooling rate studies of 12002 were conducted and the results interpreted in terms of the crystallization history of this rock and certain other picritic Apollo 12 samples. Calculations of liquid densities and viscosities during crystallization, crystal settling velocities, and heat loss by the parent rock body are discussed, as are petrographic studies of other Apollo 12 samples. The process of magmatic differentiation that must have accompanied the early melting and chemical fractionation of the moon's outer layers was investigated. The source of regions of both high- and low-titanium mare basalts were also studied.

Hays, J. F.↗

Urine sampling and collection system optimization and testing

A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

Fogal, G. L.↗

The significance of observed rotational magnetic hysteresis in lunar samples

Rotational magnetic hysteresis curves for lunar soils 10084, 12070, and 14259, and rock 14053 have been published. There is no adequate explanation to date for the observed large hysteresis at high fields. Lunar rock magnetism researchers consider fine particle iron to be the primary source of stable magnetic remanence in lunar samples. Iron has cubic anisotropy with added shape anisotropy for extreme particle shapes. The observed high-field hysteresis must have its source in uniaxial or unidirectional anisotropy. This implies the existence of minerals with uniaxial anisotropy or exchange-coupled spin states. Therefore, the source of this observed high-field hysteresis must be identified and understood before serious paleointensity studies are made. It is probable that the exchange-coupled spin states and/or the source of uniaxial anisotropy responsible for the high-field hysteresis might be influenced by the lunar surface diurnal temperature cycling. The possible sources of high-field hysteresis in lunar samples are presented and considered.

Wasilewski, P.↗

The use of Whatman-41 filters for high volume air sampling

The feasibility of using W41 filter media on a routine TSP high-volume monitoring network was determined by comparison with glass fiber (GF) filtering. Results indicate that suspended particulate samples from GF filters averaged slightly, but not significantly, higher than those from Whatman-41 filters. Some extra handling procedures were required to avoid errors due to the hygroscopic nature of W41 filters; these added procedures are not overly burdensome, however, and they allow the performance of analytical work, thus extending the capabilities of high-volume sampling. It was demonstrated that W41 filters are practical for air quality monitoring and elemental analysis in environments similar to Cleveland's.

Neustadter, H. E.↗

A sample holding technique for study of crystal growth in silicate melts

A thin platinum wire loop is an effective way to hold silicate melts during experimentation in a gas-mixing furnace. This method results in a minimum of physical and chemical interaction between the sample and container but maximum interaction between sample and gas mixture. However, volatilization of sodium occurs while the silicate is molten. By minimizing the chance of heterogeneous nucleation, the method is ideal for experimental investigation of the origin of rock textures.

Donaldson, C. H.↗

Chemical studies of Apollo 16 and 17 samples

Instrumental neutron activation analyses were conducted to nine Apollo 16 samples and 23 Apollo 17 samples. Radiochemical neutron activation analyses were carried out in the case of six Apollo 16 boulder-2 rocks, five Apollo 17 soils, and one Apollo 16 soil. The elemental abundances obtained are presented in tables and the significance of the analytical results is discussed. Attention is also given to interelement correlations.

Laul, J. C.↗

Labile and nonlabile element relationships among Apollo 17 samples

Volatile and nonvolatile trace element contents in a suite of Apollo 17 soils and rocks are studied. It is found that the halogens exhibit a remarkable degree of coherence because of their apparent diverse geochemistry, that the F-Cl-P2O5 coherence previously noted persists among Apollo 17 samples, that both U and Ru-Os support lateral mixing of regolith on a local scale, and that the meteoritic Ru/Os ratios found in a few samples are attributed to primitive lunar material that has not been extensively recycled.

Jovanovic, S.↗

Determination of natural and cosmic ray induced radionuclides in Apollo 17 lunar samples

Natural and cosmic ray induced radionuclides have been determined in 15 rocks and 7 soils from the Apollo 17 mission by nondestructive gamma-ray spectroscopy. The Th and K contents of these rocks and soils are shown to be linear functions of the U contents. Large amounts of Co-56, Sc-46, and Mn-54 were found in these samples due to the large proton-accelerating flares which occurred between August 2 and 6, 1972. The behavior of the Co-56 activity as a function of the Mn-54 activity seems to be the result of variation in surface to volume ratios among the samples and exposure angle. It is not necessary to invoke an asymetric solar flare flux to explain this behavior.

Keith, J. E.↗

A fast sampling device for the mass spectrometric analysis of liquid rocket engine exhaust

The design of a device to obtain compositional data on rocket exhaust by direct sampling of reactive flow exhausts into a mass spectrometer is presented. Sampling at three stages differing in pressure and orifice angle and diameter is possible. Results of calibration with pure gases and gas mixtures are erratic and of unknown accuracy for H2, limiting the usefulness of the apparatus for determining oxidizer/fuel ratios from combustion product analysis. Deposition effects are discussed, and data obtained from rocket exhaust spectra are analyzed to give O/F ratios and mixture ratio distribution. The O/F ratio determined spectrometrically is insufficiently accurate for quantitative comparison with cold flow data. However, a criterion for operating conditions with improved mixing of fuel and oxidizer which is consistent with cold flow results may be obtained by inspection of contour plots. A chemical inefficiency in the combustion process when oxidizer is in excess is observed from reactive flow measurements. Present results were obtained with N2O4/N2H4 propellants.

Ryason, P. R.↗

Technology for return of planetary samples

Technological requirements of a planetary return sample mission were studied. The state-of-the-art for problems unique to this class of missions was assessed and technological gaps were identified. The problem areas where significant advancement of the state-of-the-art is required are: life support for the exobiota during the return trip and within the Planetary Receiving Laboratory (PRL); biohazard assessment and control technology; and quarantine qualified handling and experimentation methods and equipment for studying the returned sample in the PRL. Concepts for solving these problems are discussed.

Source record↗