Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “random testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Generalized density matrix reexamined: Microscopic approach to collective dynamics in soft spherical nuclei

The generalized density matrix method is used to calculate microscopically the parameters of the collective Hamiltonian. Higher-order anharmonicities are obtained consistently with the lowest-order results, the mean field (Hartree-Fock-Bogoliubov equation), and the harmonic potential (quasiparticle random-phase approximation). The method is applied to soft spherical nuclei, where the anharmonicities are essential for restoring the stability of the system, as the harmonic potential becomes small or negative. The approach is tested in three models of increasing complexity: the Lipkin model, model with factorizable forces, and the quadrupole plus pairing model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-114: Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms

Purpose: To evaluate whether a 3D patient-specific phantom is better able to detect known MLC errors in a clinically delivered treatment plan than conventional phantoms. 3D printing may make fabrication of such phantoms feasible. Methods: Two types of MLC errors were introduced into a clinically delivered, non-coplanar IMRT, partial brain treatment plan. First, uniformly distributed random errors of up to 3mm, 2mm, and 1mm were introduced into the MLC positions for each field. Second, systematic MLC-bank position errors of 5mm, 3.5mm, and 2mm due to simulated effects of gantry and MLC sag were introduced. The original plan was recalculated with these errors on the original CT dataset as well as cylindrical and planar IMRT QA phantoms. The original dataset was considered to be a perfect 3D patient-specific phantom. The phantoms were considered to be ideal 3D dosimetry systems with no resolution limitations. Results: Passing rates for Gamma Index (3%/3mm and no dose threshold) were calculated on the 3D phantom, cylindrical phantom, and both on a composite and field-by-field basis for the planar phantom. Pass rates for 5mm systematic and 3mm random error were 86.0%, 89.6%, 98% and 98.3% respectively. For 3.5mm systematic and 2mm random error the pass rates were 94.7%, 96.2%, 99.2% and 99.2% respectively. For 2mm systematic error with 1mm random error the pass rates were 99.9%, 100%, 100% and 100% respectively. Conclusion: A 3D phantom with the patient anatomy is able to discern errors, both severe and subtle, that are not seen using conventional phantoms. Therefore, 3D phantoms may be beneficial for commissioning new treatment machines and modalities, patient-specific QA and end-to-end testing.

60 APPLIED LIFE SCIENCES↗

K{sup {pi}}=8{sup -} isomers and K{sup {pi}}=2{sup -} octupole vibrations in N=150 shell-stabilized isotones

Isomers have been populated in {sup 246}Cm and {sup 252}No with quantum numbers K{sup {pi}}=8{sup -}, which decay through K{sup {pi}}=2{sup -} rotational bands built on octupole vibrational states. For N=150 isotones with (even) atomic number Z=94-102, the K{sup {pi}}=8{sup -} and 2{sup -} states have remarkably stable energies, indicating neutron excitations. An exception is a singular minimum in the 2{sup -} energy at Z=98, due to the additional role of proton configurations. The nearly constant energies, in isotones spanning an 18% increase in Coulomb energy near the Coulomb limit, provide a test for theory. The two-quasiparticle K{sup {pi}}=8{sup -} energies are described with single-particle energies given by the Woods-Saxon potential and the K{sup {pi}}=2{sup -} vibrational energies by quasiparticle random-phase approximation calculations. Ramifications for self-consistent mean-field theory are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Paired, Double-Blind, Randomized Comparison of a Moisturizing Durable Barrier Cream to 10% Glycerine Cream in the Prophylactic Management of Postmastectomy Irradiation Skin Care: Trans Tasman Radiation Oncology Group (TROG) 04.01

Purpose: A previous, unblinded study demonstrated that an alcohol-free barrier film containing an acrylate terpolymer (ATP) was effective in reducing skin reactions compared with a 10% glycerine cream (sorbolene). The different appearances of these products precluded a blinded comparison. To test the acrylate terpolymer principle in a double-blinded manner required the use of an alternative cream formulation, a moisturizing durable barrier cream (MDBC); the study was conducted by the Trans Tasman Radiation Oncology Group (TROG) as protocol 04.01. Methods and Materials: A total of 333 patients were randomized; 1 patient was ineligible and 14 patients withdrew or had less than 7 weeks' observations, leaving 318 for analysis. The chest wall was divided into medial and lateral compartments, and patients were randomized to have MDBC applied daily to the medial or lateral compartment and sorbolene to the other compartment. Weekly observations, photographs, and symptom scores (pain and pruritus) were collected to week 12 or resolution of skin reactions if earlier. Skin dose was confirmed by centrally calibrated thermoluminescent dosimeters. Results: Rates of medial and lateral compartment Common Toxicity Criteria (CTC), version 3, greater than or equal to grade 3 skin reactions were 23% and 41%, but rates by skin care product were identical at 32%. There was no significant difference between MDBC and sorbolene in the primary endpoint of peak skin reactions or secondary endpoints of area-under-the-curve skin reaction scores. Conclusions: The MDBC did not reduce the peak skin reaction compared to sorbolene. It is possible that this is related to the difference in the formulation of the cream compared with the film formulation. Skin dosimetry verification and double blinding are essential for radiation skin care comparative studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Tests of Single Photon Avalanche Diode for Space Applications

Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at −10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

radiation hardness↗

Rocket-in-a-Duct Performance Analysis

An axisymmetric, 110 N class, rocket configured with a free expansion between the rocket nozzle and a surrounding duct was tested in an altitude simulation facility. The propellants were gaseous hydrogen and gaseous oxygen and the hardware consisted of a heat sink type copper rocket firing through copper ducts of various diameters and lengths. A secondary flow of nitrogen was introduced at the blind end of the duct to mix with the primary rocket mass flow in the duct. This flow was in the range of 0 to 10% of the primary massflow and its effect on nozzle performance was measured. The random measurement errors on thrust and massflow were within +/-1%. One dimensional equilibrium calculations were used to establish the possible theoretical performance of these rocket-in-a-duct nozzles. Although the scale of these tests was small, they simulated the relevant flow expansion physics at a modest experimental cost. Test results indicated that lower performance was obtained at higher free expansion area ratios and longer ducts, while, higher performance was obtained with the addition of secondary flow. There was a discernable peak in specific impulse efficiency at 4% secondary flow. The small scale of these tests resulted in low performance efficiencies, but prior numerical modeling of larger rocket-in-a-duct engines predicted performance that was comparable to that of optimized rocket nozzles. This remains to be proven in large-scale, rocket-in-a-duct tests.

Schneider, Steven J.↗

Spatial curvature falsifies eternal inflation

Inflation creates large-scale cosmological density perturbations that are characterized by an isotropic, homogeneous, and Gaussian random distribution about a locally flat background. Even in a flat universe, the spatial curvature measured within one Hubble volume receives contributions from long wavelength perturbations, and will not in general be zero. These same perturbations determine the Cosmic Microwave Background (CMB) temperature fluctuations, which are O(10{sup −5}). Consequently, the low-l multipole moments in the CMB temperature map predict the value of the measured spatial curvature Ω{sub k}. On this basis we argue that a measurement of |Ω{sub k}| > 10{sup −4} would rule out slow-roll eternal inflation in our past with high confidence, while a measurement of Ω{sub k} < −10{sup −4} (which is positive curvature, a locally closed universe) rules out false-vacuum eternal inflation as well, at the same confidence level. In other words, negative curvature (a locally open universe) is consistent with false-vacuum eternal inflation but not with slow-roll eternal inflation, and positive curvature falsifies both. Near-future experiments will dramatically extend the sensitivity of Ω{sub k} measurements and constitute a sharp test of these predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast truncated SVD of sparse and dense matrices on graphics processors

We investigate the solution of low-rank matrix approximation problems using the truncated singular value decomposition (SVD). For this purpose, we develop and optimize graphics processing unit (GPU) implementations for the randomized SVD and a blocked variant of the Lanczos approach. Our work takes advantage of the fact that the two methods are composed of very similar linear algebra building blocks, which can be assembled using numerical kernels from existing high-performance linear algebra libraries. Furthermore, the experiments with several sparse matrices arising in representative real-world applications and synthetic dense test matrices reveal a performance advantage of the block Lanczos algorithm when targeting the same approximation accuracy.

Computer Science↗

Final Scientific/Technical Report. A closed path methane and water vapor gas analyzer

Robust, economical, low-power and reliable closed-path methane (CH 4 ), carbon dioxide (CO 2 ), and water vapor (H 2 O) analyzers suitable for long-term measurements are not readily available commercially. Such analyzers are essential for quantifying the amount of CH 4 and CO 2 released from various ecosystems (wetlands, rice paddies, forests, etc.) and other surface contexts (e.g. landfills, animal husbandry lots, etc.), and for understanding the dynamics of the atmospheric CH4 and CO 2 budget and their impact on climate change and global warming. The purpose of this project is to develop a closed-path methane, carbon dioxide gas and water vapor analyzer capable of long-term measurements in remote areas for global climate change and environmental research. The analyzer will be capable of being deployed over a wide range of ecosystems to understand methane and carbon dioxide exchange between the atmosphere and the surface. Measurements of methane and carbon dioxide exchange need to be made all year-round with limited maintenance requirements. During this Phase II effort, we successfully completed the design of the electronics, optical bench, trace gas detection method and mechanical infrastructure. We are using the technologies of two vertical cavity surface emitting lasers, a multiple-pass Herriott optical cell, wavelength modulation spectroscopy and direct absorption to measure methane, carbon dioxide, and water vapor. We also have designed the instrument application software, Field Programmable Gate Array (FPGA), along with partial completion of the embedded software. The optical bench has been tested in a lab setting with very good results. Major sources of optical noise have been identified and through design, the optical noise floor is approaching -60dB. Both laser modules can be temperature controlled to help maximize the stability of the analyzer. Additionally, a piezo electric transducer has been utilized to randomize the noise introduced from potential etalons. It is expected that all original specifications contained within the initial proposal will be met. We are currently in the beginning stages of assembling the first generation prototypes and finalizing the remaining design elements. The first prototypes will initially be tested in our environmental calibration chamber in which specific gas concentrations, temperature and humidity levels can be controlled. Once operation in this controlled setting is verified, the prototypes will be deployed at LI-COR's Experimental Research Station (LERS). Deployment at the LERS site will test the instrument's robustness in a real-world situation.

47 OTHER INSTRUMENTATION↗

Effects of Acute Exposures to Carbon Dioxide upon Cognitive Functions

Carbon dioxide (CO2) originates from human metabolism and typically remains about 10-fold higher in concentration on the International Space Station (ISS) than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the ISS that associates CO2 levels with reports of headaches by crewmembers. Consequently, flight rules have been employed to control CO2 below 3 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached, and there is evidence that CO2 has effects at levels below the threshold for headaches. This concern appears to be substantiated in reports that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. Therefore, we set out to determine if decision-making under volatile, uncertain, confusing and ambiguous circumstances, where feedback is delayed or absent, is correlated with low levels of CO2 during acute exposures (several hours) in crew-like subjects and to determine if additional cognitive domains are sensitive to concentrations of CO2 at, or below, current ISS levels by using a test battery that is currently available onboard ISS. We enrolled 22 volunteers (8 females, 14 males) between the ages of 30-55 (38.8 +/- 7.0) years whose training and professional experience reflect that of the astronaut corps. Subjects were divided among 4 study groups. Exposures occurred in the 20-foot environmental chamber in Bldg 7 at JSC. Each group was exposed to each of four concentrations of CO2 (600, 1200, 2500, and 5000 ppm), and the exposure order was balanced across the groups which were randomly assigned to 4 possible complete exposure orders. Study participants and investigators were blinded to the exposure order. Each exposure lasted 4 hours and occurred on the same day each week for 4 consecutive weeks. Testing included the Strategic Management Simulation (SMS) methodology and the Cognition battery of psychometric measures that are being utilized aboard the ISS. Subjects participated in a familiarization session one week prior to the start of exposure sessions. Each exposure session followed the schedule noted in Figure 1 below. On the morning of each exposure, subjects completed the Cognition battery in a conference room at indoor ambient CO2 levels. Subjects then entered the exposure chamber and were acclimated to the environment for 15 minutes before completing another round of the Cognition battery. After a 20 minute rest, subject completed the approx.80 minute SMS. Subjects were allowed another 20 minute rest period before completing the final Cognition test battery in the exposure chamber. Subjects then returned to the conference room where they completed one final round of Cognition. Data from both testing methodologies are currently being analyzed and will be presented. Study investigators have not yet been unblinded to the coded exposure concentrations, but preliminary results suggest differences.

Ryder, V. E.↗

Mushroom body input connections form independently of sensory activity in Drosophila melanogaster

Associative brain centers, such as the insect mushroom body, need to represent sensory information in an efficient manner. In Drosophila melanogaster, the Kenyon cells of the mushroom body integrate inputs from a random set of olfactory projection neurons, but some projection neurons—namely those activated by a few ethologically meaningful odors—connect to Kenyon cells more frequently than others. This biased and random connectivity pattern is conceivably advantageous, as it enables the mushroom body to represent a large number of odors as unique activity patterns while prioritizing the representation of a few specific odors. How this connectivity pattern is established remains largely unknown. Here, we test whether the mechanisms patterning the connections between Kenyon cells and projection neurons depend on sensory activity or whether they are hardwired. We mapped a large number of mushroom body input connections in partially anosmic flies—flies lacking the obligate odorant co-receptor Orco—and in wild-type flies. Statistical analyses of these datasets reveal that the random and biased connectivity pattern observed between Kenyon cells and projection neurons forms normally in the absence of most olfactory sensory activity. Finally, this finding supports the idea that even comparatively subtle, population-level patterns of neuronal connectivity can be encoded by fixed genetic programs and are likely to be the result of evolved prioritization of ecologically and ethologically salient stimuli.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

60 APPLIED LIFE SCIENCES↗

ELLIPTICAL WEIGHTED HOLICs FOR WEAK LENSING SHEAR MEASUREMENT. III. THE EFFECT OF RANDOM COUNT NOISE ON IMAGE MOMENTS IN WEAK LENSING ANALYSIS

This is the third paper on the improvement of systematic errors in weak lensing analysis using an elliptical weight function, referred to as E-HOLICs. In previous papers, we succeeded in avoiding errors that depend on the ellipticity of the background image. In this paper, we investigate the systematic error that depends on the signal-to-noise ratio of the background image. We find that the origin of this error is the random count noise that comes from the Poisson noise of sky counts. The random count noise makes additional moments and centroid shift error, and those first-order effects are canceled in averaging, but the second-order effects are not canceled. We derive the formulae that correct this systematic error due to the random count noise in measuring the moments and ellipticity of the background image. The correction formulae obtained are expressed as combinations of complex moments of the image, and thus can correct the systematic errors caused by each object. We test their validity using a simulated image and find that the systematic error becomes less than 1% in the measured ellipticity for objects with an IMCAT significance threshold of {nu} {approx} 11.7.

79 ASTRONOMY AND ASTROPHYSICS↗

Primary Analysis of a Phase II Randomized Trial Radiation Therapy Oncology Group (RTOG) 0212: Impact of Different Total Doses and Schedules of Prophylactic Cranial Irradiation on Chronic Neurotoxicity and Quality of Life for Patients With Limited-Disease Small-Cell Lung Cancer

Purpose: To determine the effect of dose and fractionation schedule of prophylactic cranial irradiation (PCI) on the incidence of chronic neurotoxicity (CNt) and changes in quality of life for selected patients with limited-disease small-cell lung cancer (LD SCLC). Methods and Materials: Patients with LD SCLC who achieved a complete response after chemotherapy and thoracic irradiation were eligible for randomization to undergo PCI to a total dose of 25 Gy in 10 daily fractions (Arm 1) vs. the experimental cohort of 36 Gy. Those receiving 36 Gy underwent a secondary randomization between daily 18 fractions (Arm 2) and twice-daily 24 fractions (Arm 3). Enrolled patients participated in baseline and follow-up neuropsychological test batteries along with quality-of-life assessments. Results: A total of 265 patients were accrued, with 131 in Arm 1, 67 in Arm 2, and 66 in Arm 3 being eligible. There are 112 patients (42.2%) alive with 25.3 months of median follow-up. There were no significant baseline differences among groups regarding quality-of-life measures and one of the neuropsychological tests, namely the Hopkins Verbal Learning Test. However, at 12 months after PCI there was a significant increase in the occurrence of CNt in the 36-Gy cohort (p = 0.02). Logistic regression analysis revealed increasing age to be the most significant predictor of CNt (p = 0.005). Conclusions: Because of the increased risk of developing CNt in study patients with 36 Gy, a total PCI dose of 25 Gy remains the standard of care for patients with LD SCLC attaining a complete response to initial chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring drought-responsive crucial genes in Sorghum

Drought severely affects global food production. Sorghum is a typical drought-resistant model crop. Based on RNA-seq data for Sorghum with multiple time points and the gray correlation coefficient, this paper firstly selects candidate genes via mean variance test and constructs weighted gene differential co-expression networks (WGDCNs); then, based on guilt-by-rewiring principle, the WGDCNs and the hidden Markov random field model, drought-responsive crucial genes are identified for five developmental stages respectively. Enrichment and sequence alignment analysis reveal that the screened genes may play critical functional roles in drought responsiveness. A multilayer differential co-expression network for the screened genes reveals that Sorghum is very sensitive to pre-flowering drought. Furthermore, a crucial gene regulatory module is established, which regulates drought responsiveness via plant hormone signal transduction, MAPK cascades, and transcriptional regulations. The proposed method can well excavate crucial genes through RNA-seq data, which have implications in breeding of new varieties with improved drought tolerance.

60 APPLIED LIFE SCIENCES↗

A large-scale comparison of Artificial Intelligence and Data Mining (AI&DM) techniques in simulating reservoir releases over the Upper Colorado Region

In recent years, the Artificial Intelligence and Data Mining (AI&DM) models have become popular tools in assisting various aspects of reservoir operation. However, the practical uses are still rarely reported. Comparison experiment of many AI&DM models over a large number of reservoir cases is particularly valuable to help reservoir operators first examine the usefulness and transferability of different AI&DM models, and then identify the most stable and reliable AI&DM model in assist of various decision-making processes. In this study, a total of 12 AI&DM models with different parameterizations and simulation scenarios are comprehensively tested out and compared in simulating the controlled reservoir outflows of 33 reservoir cases over the Upper Colorado Region, United States. Results show that the Random Forecast and the Long-Short-Term-Memory model could consistently derive the best statistical performance than other models under the baseline simulation scenario. The employed AI&DM models could obtain satisfactory statistical interquartile ranges (25–75%) between [0.6–0.9], [0.3–0.8], and [0.2–0.8], for CORR, NSE, and KGE measurements, respectively, and [1.5–6.5], [–15 to 20], and [0.5–8.5] for the normalized RMSE, PBIAS and RSR measurements, respectively. Results also show Multi-Layer Perceptron model and Extreme Gradient Boosting Tree Algorithm produced more stable and superior performance than other models under more complex input scenarios. We also found that the performance of different AI&DM models are closely relevant to the reservoir elevations, sizes, and functionalities. Discussions were made about the sensitivity of AI&DM models’ parameterizations and the key advantages of AI&DM models over the rule-based reservoir models. We further identify that the main advantage of AI&DM models is the flexibility in designing input structures, whereas the rule-based simulation model is rather limited. Future studies were suggested regarding the best way reservoir operators and researchers could use, select, and apply different AI&DM models in simulating reservoir releases under different natural and modeling environments. Finally, this comparison study also serves as a reference and a piece of groundwork for further promoting the practical uses of AI&DM models in assisting reservoir operation.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Material Design Principles for Calcium-Ion Mobility in Intercalation Cathodes

Multivalent-ion batteries offer an alternative to Li-based technologies, with the potential for greater sustainability, improved safety, and higher energy density, primarily due to their rechargeable system featuring a passivating metal anode. Although a system based on the Ca 2+ /Ca couple is particularly attractive given the low electrochemical plating potential of Ca 2+ , the remaining challenge for a viable rechargeable Ca battery is to identify Ca cathodes with fast ion transport. In this work, a high-throughput computational pipeline is adapted to (1) discover novel Ca cathodes in a largely unexplored space of empty intercalation hosts and (2) develop material design rules for Ca-ion mobility. One candidate from the screening, W 2 O 3 (PO 4 ) 2 , is confirmed to have a low Nudged Elastic Band (NEB) barrier of 168 meV within a one-dimensional (1D) ion percolation topology. This candidate is subsequently synthesized and electrochemically tested, achieving reversible Ca cycling with a capacity of 25 mA h/g. To further accelerate the screening for promising Ca intercalation electrodes, machine learning (ML) Random Forest (RF) and Extreme Gradient Boosting (XGB) classification models are created with local environment descriptors based on a large, structurally and chemically diverse dataset of minimum energy pathways, spanning over 5,000 density functional theory (DFT) site energy calculations. Accuracies of 92% are achieved, material design metrics are quantified, ML force-fields are leveraged in an accelerated iteration of the screening, and a total of 27 novel Ca cathode materials are highlighted for further investigation.

25 ENERGY STORAGE↗

Machine learning and process-based modeling of spatiotemporal changes in active layer thickness across Alaska

Permafrost degradation poses a growing threat to infrastructure stability and ecosystem resilience in the rapidly warming Arctic. We investigated the spatiotemporal dynamics of active layer thickness (ALT) across Alaska by integrating field observations, environmental datasets, a physically based Stefan model, and machine learning (ML) techniques. Using weather projections from the Coupled Model Intercomparison Project Phase 6 under two Shared Socioeconomic Pathways (SSP 2-4.5 and SSP 5-8.5), we assessed ALT sensitivity to projected future weather conditions. The random forest (RF) model outperformed the Stefan approach in predicting ALT on the training dataset (R² = 0.84 vs. 0.53) but demonstrated lower generalizability on the test dataset (R² = 0.24 vs. 0.54). The root mean square error (RMSE) for the RF model for training and testing ranged from 14 to 22 cm, compared to 17 and 18 cm for the Stefan model. Variable importance analysis revealed that mean annual temperature and slope angle were the strongest predictors of ALT, accounting for 19% and 18% of the variance, respectively, followed by sediment transport index (14%) and stream power index (11%). Comparative analysis of baseline ALT predictions showed the Stefan model tended to project a thicker active layer (mean ± SD: 65 ± 16 cm), compared to the RF model (mean ± SD: 59 ± 8.8) cm). Both models indicated a latitudinal gradient in ALT, with shallower depths at higher latitudes. Projected ALT increases by 2100 were estimated at 3.3 ± 2.2 cm under SSP 2-4.5 and 5.9 ± 4.0 cm under SSP 5-8.5 for the ML model, whereas the Stefan model projected substantially larger increases of 13 ± 2.6 cm (SSP 2-4.5) and 28 ± 4.4 cm (SSP5-8.5). Spatial analysis showed the greatest ALT increases in northern Alaska, with relatively smaller changes in southern regions. These findings highlight the complex, multifactorial nature of ALT dynamics and the value of hybrid modeling approaches. As rising temperatures accelerate permafrost thaw, changes in ALT can disrupt ecosystems, damage infrastructures, and enhance the release of stored soil carbon, highlighting the urgent need for improved predictive capabilities to inform adaptation strategies in the Arctic.

Climate sciences↗