Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Adaptive Online Model Update Algorithm for Predictive Control in Networked Systems

In this article, we introduce an adaptive on-line model update algorithm designed for predictive control applications in networked systems, particularly focusing on power distribution systems. Unlike traditional methods that depend on historical data for offline model identification, our approach utilizes real-time data for continuous model updates. This method integrates seamlessly with existing online control and optimization algorithms and provides timely updates in response to real-time changes. This methodology offers significant advantages, including a reduction in the communication network bandwidth requirements by minimizing the data exchanged at each iteration and enabling the model to adapt after disturbances. Furthermore, our algorithm is tailored for non-linear convex models, enhancing its applicability to practical scenarios. The efficacy of the proposed method is validated through a numerical study, demonstrating improved control performance using a synthetic IEEE test case.

data-driven model predictive control↗

Component Repair Times Obtained from MSPI Data

Information concerning times to repair or restore equipment to service given a failure is valuable to probabilistic risk assessments (PRAs). Examples of such uses in modern PRAs include estimation of the probability of failing to restore a failed component within a specified time period (typically tied to recovering a mitigating system before core damage occurs at nuclear power plants) and the determination of mission times for support system initiating event (SSIE) fault tree models. Information on equipment repair or restoration times applicable to PRA modeling is limited and dated for U.S. commercial nuclear power plants. However, the Mitigating Systems Performance Index (MSPI) program covering all U.S. commercial nuclear power plants provides up-to-date information on restoration times for a limited set of component types. This paper describes the MSPI program data available and analyzes the data to obtain median and mean component restoration times as well as non-restoration cumulative probability curves. The MSPI program provides guidance for monitoring both planned and unplanned outages of trains of selected mitigating systems deemed important to safety. For systems included within the MSPI program, plants monitor both train UA and component unreliability (UR) against baseline values. If the combined system UA and UR increases sufficiently above established baseline results (converted to an estimated change in core damage frequency or CDF), a “white” (or worse) indicator is generated for that system. That in turn results in increased oversight by the US Nuclear Regulatory Commission (NRC) and can impact a plant’s insurance rating. Therefore, there is pressure to return MSPI program components to service as soon as possible after a failure occurs. Three sets of unplanned outages might be used to determine the component repair durations desired in this article: all unplanned outages for the train type that includes the component of interest, only unplanned outages associated with failures of the component of interest, and only unplanned outages associated with PRA failures of the component of interest. The paper will describe how component repair times can be generated from each set and which approach is most applicable. Repair time information will be summarized for MSPI pumps and diesel generators using data over 2003 – 2007. Also, trend information over 2003 – 2012 will be presented to indicate whether the 2003 – 2007 repair time information is still considered applicable. For certain types of pumps, mean repair times are significantly higher than the typically assumed 24 h duration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modelling a Heaving Point-Absorber with a Closed-Loop Control System Using the DualSPHysics Code

The present work addresses the need for an efficient, versatile, accurate and open-source numerical tool to be used during the design stage of wave energy converters (WECs). The device considered here is the heaving point-absorber developed and tested by Sandia National Laboratories. The smoothed particle hydrodynamics (SPH) method, as implemented in DualSPHysics, is proposed since its meshless approach presents some important advantages when simulating floating devices. The dynamics of the power take-off system are also modelled by coupling DualSPHysics with the multi-physics library Project Chrono. A satisfactory matching between experimental and numerical results is obtained for: (i) the heave response of the device when forced via its actuator; (ii) the vertical forces acting on the fixed device under regular waves and; (iii) the heave response of the WEC under the action of both regular waves and the actuator force. This proves the ability of the numerical approach proposed to simulate accurately the fluid–structure interaction along with the WEC’s closed-loop control system. In addition, radiation models built from the experimental and WAMIT results are compared with DualSPHysics by plotting the intrinsic impedance in the frequency domain, showing that the SPH method can be also employed for system identification.

42 ENGINEERING↗

A two-level structure for advanced space power system automation

The tasks to be carried out during the three-year project period are: (1) performing extensive simulation using existing mathematical models to build a specific knowledge base of the operating characteristics of space power systems; (2) carrying out the necessary basic research on hierarchical control structures, real-time quantitative algorithms, and decision-theoretic procedures; (3) developing a two-level automation scheme for fault detection and diagnosis, maintenance and restoration scheduling, and load management; and (4) testing and demonstration. The outlines of the proposed system structure that served as a master plan for this project, work accomplished, concluding remarks, and ideas for future work are also addressed.

Loparo, Kenneth A.↗

Accelerating Transitions to Zero Carbon Power Systems

As power systems evolve, becoming increasingly renewable, distributed, dynamic, and digital, managing them becomes ever more challenging and complex. System operators serve as the "air traffic controllers" for electricity grids, working to balance supply and demand, manage evolving electricity markets, and ensure the safety and reliability of electricity systems. To adapt to the rapidly changing energy landscape and support the transition to modern, zero carbon power systems, system operators must develop and adopt new technologies, approaches, and frameworks. The Global Power System Transformation (G-PST) Consortium is a network of system operators, research institutions, and industry partners working to accelerate and scale the technical solutions required to transform our world's power systems. By developing and sharing robust models and tools, research and demonstration results, knowledge, and innovation, the G-PST Consortium is empowering system operators to transition to 100% renewable energy while ensuring the reliability, safety, and cost-effectiveness of grid operations.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

LOWERING THE LEVELIZED COST OF ELECTRICITY OF A CONCENTRATING SOLAR POWER TOWER WITH A SUPERCRITICAL CARBON DIOXIDE POWER CYCLE

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). The cost of CSP is assessed with the System Advisor Model (SAM) from the National Renewable Energy Laboratory (NREL). The performance of an integrally geared compressor-expander recuperated recompression cycle with supercritical carbon dioxide (sCO2) as the working fluid is modeled. A comparison of the cycle model to the integrated SAM cycle performance is made. The cycle model incorporates innovative cycle control methods to improve the range of efficiency, including inventory control. The SAM model is modified to accommodate the predicted cycle performance. The ultimate goal of minimizing the LCOE is targeted through multiple approaches, including the cost of the power block, the impact of system scale, the sizing of the thermal system relative to the power block system, the operating approach for changes in ambient temperature and availability of sunlight. Through reduced power block cost and a detailed cycle model, the LCOE is modeled to be 5.98 ¢/kWh, achieving targeted techno-economic performance. The LCOE of the CSP system is compared to the cost of hybrid solar and fossil-fired systems. An analysis is made on the efficacy of a fossil backup system with CSP and how that relates to potential future costs of carbon dioxide emissions

schmitt, josh↗

Thermal System Modeling for Lunar and Martian Surface Regenerative Fuel Cell Systems

The Advanced Exploration Systems (AES) Advanced Modular Power Systems (AMPS) Project is investigating different power systems for various lunar and Martian mission concepts. The AMPS Fuel Cell (FC) team has created two system-level models to evaluate the performance of regenerative fuel cell (RFC) systems employing different fuel cell chemistries. Proton Exchange Membrane fuel cells PEMFCs contain a polymer electrolyte membrane that separates the hydrogen and oxygen cavities and conducts hydrogen cations (protons) across the cell. Solid Oxide fuel cells (SOFCs) operate at high temperatures, using a zirconia-based solid ceramic electrolyte to conduct oxygen anions across the cell. The purpose of the modeling effort is to down select one fuel cell chemistry for a more detailed design effort. Figures of merit include the system mass, volume, round trip efficiency, and electrolyzer charge power required. PEMFCs operate at around 60 degrees Celsius versus SOFCs which operate at temperatures greater than 700 degrees Celsius. Due to the drastically different operating temperatures of the two chemistries the thermal control systems (TCS) differ. The PEM TCS is less complex and is characterized by a single pump cooling loop that uses deionized water coolant and rejects heat generated by the system to the environment via a radiator. The solid oxide TCS has its own unique challenges including the requirement to reject high quality heat and to condense the steam produced in the reaction. This paper discusses the modeling of thermal control systems for an extraterrestrial RFC that utilizes either a PEM or solid oxide fuel cell.

thermal modeling↗

Sensitivity of Concentrating Solar Power Trough Performance, Cost and Financing with Solar Advisor Model

A comprehensive solar technology systems analysis model, the Solar Advisor Model (SAM) was developed to support the federal R&D community and the solar industry. This model, developed by staff at NREL and Sandia National Laboratory, is able to model the costs, finances, and performance of concentrating solar power and photovoltaics (PV). Currently, parabolic troughs and concentrating PV are the two concentrating technologies modeled within the SAM environment.

14 SOLAR ENERGY↗

Reliability and Resiliency in South Asia's Power Sector - Pathways for Research, Modeling, and Implementation

Reliability and resilience are the core principles of power system planning and operations around the world. Power systems in South Asia are transforming with increasing penetration of clean energy generation resources, emerging technologies, increasing electricity demand and electrification. At the same time, these power systems are facing challenges posed by extreme weather events and climate change. All these factors would add furthermore importance to the reliability and resilience of future power systems in South Asia. This has motivated us to better understand the country specific challenges and chalk out the pathways for research, modelling and implementation in South Asia. Our research, experience in the region and feedback from key stakeholders indicate following as the key areas where more work is needed to improve reliability and resilience of power systems in the region: Renewable energy Data for power system studies, New Tools and Studies, Resilience Planning, Resource Adequacy, Advanced RE Forecasting, Cybersecurity, Load Forecasting, and Coordinated Planning and Operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

IM3 GO WEST Parameter Search Dataset

GO WEST is an open-source power grid modeling framework for U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It is developed to address weather and water dynamics, and associated vulnerabilities in this bulk power system. It covers 28 balancing authorities (BA) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of U.S. Western Interconnection created by Texas A&M University. Users can try and select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. Therefore, GO WEST can help researchers to strike a balance between model fidelity (i.e. accuracy) and computational complexity (i.e. runtime). This dataset includes model inputs and outputs from 600 model versions for each 2019, 2020, and 2021. The folder naming convention is as follows: Exp{Number of Nodes}_{Mathematical Formulation}_{Transmission Line Limit Scaling Factor in MW}_{Hurdle Rate Scaling Factor in %}_{Year}. Linear programming is designated with "simple" label whereas mixed-integer linear programming is designated with "coal" label. For example, "Exp100_simple_1000_50_2019" folder contains inputs and outputs from 2019 model version with 100 nodes, linear programming, +1000 MW transmission line limit scaling factor, and +50% hurdle rate scaling factor. GO WEST GitHub repository hosts all raw datasets, processing scripts, and model scripts. Please refer to the README file for a detailed description of the included files.

Economics↗

Modeling and Impact of Hyperloop Technology on the Electricity Grid

This paper provides an overview of hyperloop technologies, including a brief discussion of key components of a hyperloop system that determine the electric power requirements as a function of time. At-scale hyperloop systems do not yet exist, so a model was used to generate a set of load profiles for conceptual hyperloop realizations at four locations in the United States: two systems in California and one each in Colorado and Ohio. In all four cases, the modeled hyperloop load profiles included pulses in both active and reactive power. Grid modeling was performed to estimate the grid impacts and for dis-cussing grid integration challenges. The paper discusses how energy storage systems might be used to eliminate the pulsating load characteristics or significantly reduce it to accommodate current grid planning guidelines

24 POWER TRANSMISSION AND DISTRIBUTION↗

SURVEY OF COUPLING SCHEMES IN TRADITIONAL COUPLED NEUTRONICS AND THERMAL-HYDRAULICS CODES

The design and the analysis of nuclear power plants (NPPs) require computational codes to predict the behavior of the NPP nuclear components and other systems (i.e., reactor core, primary coolant system, emergency core cooling system, etc.). Coupled calculations are essential to the conduct of deterministic safety assessments. Inasmuch as the physical phenomena that govern the performance of a nuclear reactor are always present simultaneously, ideally computational modeling of a nuclear reactor should include coupled codes that represent all of the active physical phenomena. Such multi-physics codes are under development at several institutions and are expected to become operational in the future. However, in the interim, integrated codes that incorporate modeling capabilities for two to three physical phenomena will remain useful. For example, in the conduct of safety analyses, of paramount importance are codes that couple neutronics and thermal-hydraulics, especially transient codes. Other code systems of importance to safety analyses are those that couple primary system thermal-hydraulics to fission product chemistry, neutronics to fuel performance, containment behavior and structural mechanics to thermal-hydraulics, etc. This paper surveys the methods used traditionally in the coupling of neutronic and thermal-hydraulics codes. The neutron kinetics codes are used for computing the space-time evolution of the neutron flux and, hence, of the power distribution. The thermal-hydraulics codes, which compute mass, momentum and energy transfers, model the coolant flow and the temperature distribution. These codes can be used to compute the neutronic behavior and the thermal-hydraulic states separately. However, the need to account with fidelity for the dynamic feedback between the two sets of properties (via temperature and density effects on the cross section inputs into the neutronics codes) and the requirement to model realistically the transient response of nuclear power plants and to assess the associated emergency systems and procedures imply the necessity of modeling the neutronic and thermal-hydraulics simultaneously within a coupled code system. The focus of this paper is a comparison of the methods by which the coupling between neutron kinetics and thermal-hydraulics treatments has been traditionally achieved in various code systems. As discussed in the last section, the modern approaches to multi-physics code development are beyond the scope of this paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Properties of a finite fully spin-polarized free homogeneous one-dimensional electron gas

The homogeneous electron gas model has been quite successful to predict the bulk properties of systems of electrons at various densities. In many occasions, a simplified free homogeneous electron gas model represents a powerful first approximation to a real system. Despite our considerable knowledge on the bulk properties of a homogeneous electron gas, advances in nanoscience and nanotechnology call for a greater effort to understand the opposite limit of small finite systems of electrons with size-dependent properties. In this work, we provide a detailed description of the properties of a finite fully spin-polarized (spinless) free homogeneous one-dimensional electron gas, the simplest of the free homogeneous electron gases. We derive exact analytical results for various quantities such as the one-particle density function, two-particle density function, one-particle density matrix, pair correlation function and energy of finite systems with an arbitrary number of electrons. The results obtained provide a detailed view on how various quantities corresponding to a finite system approach their bulk (thermodynamic limit) value.

36 MATERIALS SCIENCE↗

Enhancements to Engineering-scale Reactor Pressure Vessel Fracture Capabilities in Grizzly

The Grizzly code is being developed to model the effect of aging in nuclear power plant systems, components, and structures. A significant part of this effort has been to develop capabilites to model the effects of embrittlement in reactor pressure vessels on their integrity. This includes both modeling of microstructure and engineering property evolution, and engineering-scale probabilistic fracture mechanics analysis. This report documents recent advances to the engineering-scale fracture mechanics capability for evaluation of RPV integrity under transient loading in Grizzly. These developments are in three areas: probabilistic fracture mechanics, general reduced order models for fracture a flaw locations, and improvments to the XFEM capability used in Grizzly for fracture mechanics analysis. The combination of these developments brings Grizzly closer to a state where it can be applied in production as a general tool for engineering-scale fracture mechanics analysis. The probabilistic fracture mechanics capabilities are included in the 1.5 testing version of Grizzly, and will be further refined in preparation for production use in the 2.0 released planned for fiscal year 2018.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flexibility Reserve in Power Systems: Definition and Stochastic Multi-Fidelity Optimization

This paper defines flexibility reserve trajectory as a single reserve product that not only supplies the energy imbalance in real-time operation but also the resulting ramping requirements by embedding the flexible ramping trajectories as time derivative of the reserve trajectories. Further, a stochastic optimization model is proposed for multi-fidelity co-optimization of energy and flexibility reserve in day-ahead power systems operation. The proposed model integrates operation decisions with different levels of modeling fidelity in a single stochastic optimization problem. More specifically, day-ahead energy trajectories, day-ahead flexibility reserve capacity trajectories, and real-time flexibility reserve deployment trajectories are modeled by Bernstein polynomials with different degrees as required to match the load and renewable generation with different levels of variability in day-ahead and real-time operations. The proposed model is implemented on the IEEE reliability test system using load and solar generation data of California ISO, where the numerical results demonstrate that the proposed model schedules a reserve capacity that more accurately matches the real-time energy imbalance and ramping requirements of net-load, while reducing the total operation cost of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗