Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Lessons Learned From the Flight of the NASA In-Step Cryo System Experiment

The Cryo System Experiment was developed to validate in near zero-g space a 65 K cryogenic system for focal planes, optics, or other imaging instruments that require continuous cryogenic cooling. Two key cryogenic technologies, designed to improve performance of systems for scientific, commercial and defense applications in space, were successfully demonstrated on a February 1995 Shuttle mission. The two were a 2-watt 65 K long-life low- vibration Stirling cooler and a diode oxygen heat pipe thermal switch. Lessons learned are presented.

cryogenics↗

INFRARED SPECTRA AND OPTICAL CONSTANTS OF NITRILE ICES RELEVANT TO TITAN's ATMOSPHERE

Spectra and optical constants of nitrile ices known or suspected to be in Titan's atmosphere are presented from 2.0 to 333.3 {mu}m ({approx}5000-30 cm{sup -1}). These results are relevant to the ongoing modeling of Cassini CIRS observations of Titan's winter pole. Ices studied are: HCN, hydrogen cyanide; C{sub 2}N{sub 2}, cyanogen; CH{sub 3}CN, acetonitrile; C{sub 2}H{sub 5}CN, propionitrile; and HC{sub 3}N, cyanoacetylene. For each of these molecules, we also report new cryogenic measurements of the real refractive index, n, determined in both the amorphous and crystalline phases at 670 nm. These new values have been incorporated into our optical constant calculations. Spectra were measured and optical constants were calculated for each nitrile at a variety of temperatures, including, but not limited to, 20, 35, 50, 75, 95, and 110 K, in both the amorphous phase and the crystalline phase. This laboratory effort used a dedicated FTIR spectrometer to record transmission spectra of thin-film ice samples. Laser interference was used to measure film thickness during condensation onto a transparent cold window attached to the tail section of a closed-cycle helium cryostat. Optical constants, real (n) and imaginary (k) refractive indices, were determined using Kramers-Kronig analysis. Our calculation reproduces the complete spectrum, including all interference effects.

79 ASTRONOMY AND ASTROPHYSICS↗

A tabletop femtosecond time-resolved soft x-ray transient absorption spectrometer

A laser-based, tabletop instrument is constructed to perform femtosecond soft x-ray transient absorption spectroscopy. Ultrashort soft x-ray pulses produced via high-order harmonic generation of the amplified output of a femtosecond Ti:sapphire laser system are used to probe atomic core-level transient absorptions in atoms and molecules. The results provide chemically specific, time-resolved dynamics with sub-50-fs time resolution. In this setup, high-order harmonics generated in a Ne-filled capillary waveguide are refocused by a gold-coated toroidal mirror into the sample gas cell, where the soft x-ray light intersects with an optical pump pulse. The transmitted high-order harmonics are spectrally dispersed with a homebuilt soft x-ray spectrometer, which consists of a gold-coated toroidal mirror, a uniform-line spaced plane grating, and a soft x-ray charge coupled device camera. The optical layout of the instrument, design of the soft x-ray spectrometer, and spatial and temporal characterizations of the high-order harmonics are described. Examples of static and time-resolved photoabsorption spectra collected on this apparatus are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A table-top femtosecond time-resolved soft x-ray transient absorption spectrometer

A laser-based, table-top instrument is constructed to perform femtosecond soft x-ray transient absorption spectroscopy. Ultrashort soft x-ray pulses produced via high-order harmonic generation of the amplified output of a femtosecond Ti:sapphire laser system are used to probe atomic core-level transient absorptions in atoms and molecules. The results provide chemically specific, time-resolved dynamics with sub-50-fs time resolution. In this setup, high-order harmonics generated in a Ne-filled capillary waveguide are refocused by a gold-coated toroidal mirror into the sample gas cell, where the soft x-ray light intersects with an optical pump pulse. The transmitted high-order harmonics are spectrally dispersed with a home-built soft x-ray spectrometer, which consists of a gold-coated toroidal mirror, a uniform-line spaced plane grating, and a soft x-ray CCD camera. The optical layout of the instrument, design of the soft x-ray spectrometer, and spatial and temporal characterization of the high-order harmonics are described. Examples of static and time-resolved photoabsorption spectra collected on this apparatus are presented.

47 OTHER INSTRUMENTATION↗

Simulation of the Focusing DIRC Optics with Mathematica

The Focusing DIRC is considered for the Barrel PID at a possible Super-B factory. To reduce sensitivity to background, it would be desirable to reduce a size of the present BaBar photon detector. One way to do it is to replace it with a focusing optics and use smaller photon detector pixels. We have simulated the focusing optics with simulation software based on a 3D calculation performed with the Mathematica program. The software does not use Optica package, instead, it uses its own 3D algorithm. The advantage of the presented method is that it is transparent, fast and that it uses a full backing of the Mathematica graphics, and it does not require expertise to run Geat4 MC software.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The four- and five-band multispectral scanners for Landsat

The earth resources sensing Multispectral Scanner (MSS) for the Landsat satellite has two versions; one with four spectral bands from 0.5 to 1.1 microns, and one with five bands, the added band being 10.4 to 12.6 microns. This paper describes optical design and performance. The instrument uses a flat, object-space scanning mirror of near-linear motion, with a sensitive optical position monitor to detect mirror angular position. The 22.9-cm aperture telescope images the scene on an array of fiber optics, which dissect and transmit the scene energy to photomultiplier tubes detecting in Bands 1, 2, and 3, and silicon photodiodes detecting Band 4. Band 5 energy passes the fiber optic assembly and is reimaged on a radiatively cooled mercury cadmium telluride (HgCdTe) detector. The orbiting four-band scanner is furnishing data registered to better than 50-m band-to-band and resolving 80-m repetitive pattern over a 185-km swath width from 907-km altitude.

Lansing, J. C., Jr.↗

Investigation of High Temperature Silica Based Fiber Optic Materials (Final Report)

This report summarizes technical progress during the program “Investigation of High Temperature Silica Based Fiber Optic Materials”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to investigate and characterize the performance of commercially available optical fibers at elevated temperatures in replicated fuel gas streams. It also includes performing a comprehensive study of the interactions with the chemical constituents with respect to structural, optical, and mechanical stability and developing design strategies to assure reliable performance of deployed optical fibers and sensors. In the eight quarters of the project, work was done to complete the database of test results and findings for the creation of an optical fiber selection guide for high temperature applications. It is anticipated that this design tool will provide the scientific community with the information necessary to deploy sensing systems with the most robust and reliable fused silica optical fibers. Standard telecommunications grade germanium doped single and multimode fibers have been shown to perform reliably up to temperatures of 1100°C in non-hydrogen environments and/or properly designed sensor applications. Pure silica core single mode and low OH, large core step index multimode fibers, which have also shown to perform reliability up to temperatures of 1000ºC, are recommended for hydrogen and moist environments.

36 MATERIALS SCIENCE↗

A KB-Focusing Mirror Pair for a VUV-Raman Spectrometer at FLASH - Mirror Metrology and Ray Tracing Results

A plane mirror and two strongly curved plane elliptical mirrors comprising the refocusing system downstream the plane grating monochromator at FLASH in DESY have been characterized with the Nanometer Optical Component Measuring Machine at the BESSY-II Optics Laboratory of the Helmholtz Zentrum Berlin. Based on the measurement results the two elliptical cylinders were optimized by deterministic surface finishing technology (Ion Beam Finishing). The expected focusing performance was verified by ray tracings after each ion beam finish iteration using the measured topography results.

43 PARTICLE ACCELERATORS↗

Causes and Effects of AIRS Optics Temperature Cycles

In addition to the expected orbital thermal cycle, geophysical conditions with high thermal and reflected upwelling infrared (IR) drive measurable changes in the AIRS instrument with a period of 24 hours. Especially hot and bright scenes are important, with about 30% of the variability driven by thermal IR and 70% by reflected IR. We show how these cycles manifest in the instrument telemetry for temperatures and gain and with careful analysis can even be detected in spectral shifts.Thermal cycles are an unavoidable feature of instruments observing upwelling radiances from Earth, because the signal inherently carries varying amounts of energy into the instrument. Temperature control of the optical bench, on-board calibrator blackbody, and Focal Plane Array (FPA) in AIRS reduce the impacts of temperature variability to extremely small levels. This combined with good on-board telemetry of the temperatures and including temperature variability in our calibration algorithm has resulted in an instrument that achieves ‘climate quality’ measurements. Careful instrument and algorithm design allows us to characterize and document the impact of temperature variability and limit the effects to negligible levels, helping the instrument meet important climate-quality criteria specified in Ohring 2005

Overoye, Kenneth↗

Detailed diffraction imaging of x-ray optics crystals with synchrotron radiation

Rocking curve topography at the Advanced Photon Source’s beamline 1-BM measures the x-ray reflection from large (many cm 2 ) flat crystals on a sub-mm scale with microradian angular resolution. The $(01\bar{1}1)$ reflection at 8 keV is uniform across the crystal and close to theory for three thick quartz wafers well-polished with increasingly finer grit. However, the reflection is non-uniform for some ~ 0.1mmthin, bendable crystals that are made flat by optical contact with a flat substrate. Here, these thin crystals are bent to serve in certain x-ray diagnostics of plasmas, and similar non-uniformities could then occur in bent crystals as well. The same detail in x-ray reflection in bent crystals is unachievable with the existing topography setup: one way to get the desired resolution is with a standard microfocusing approach.

47 OTHER INSTRUMENTATION↗

Parametric oscillatory instability in a signal-recycled LIGO interferometer

The undesirable effect of parametric oscillatory instability in a LIGO (Laser Interferometer Gravitational-Wave Observatory) laser gravitational-wave antenna with a signal-recirculation mirror is analysed in detail. The instability is manifested in excitation of the Stokes optical mode and elastic mechanical mode of the mirror. It is shown that, if the eigenfrequencies of Fabry-Perot resonators in the interferometer arms are different, the parametric instability is quite small due to a small passband band width. (fifth seminar in memory of d.n. klyshko)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

Effect of Jitter on Linear Pulse-Characterization Techniques

Linear pulse-characterization techniques based on electrically driven temporal modulators can measure the electric field of optical pulses with high sensitivity and accuracy. Synchronization of the electric-drive signal to the optical source under test is paramount to their implementation, and it is important to understand the impact of relative synchronization jitter on the measured experimental trace and on the reconstructed electric field. Derivations and simulations are presented for linear spectrography, spectral shearing interferometry, and simplified chronocyclic tomography. For these three techniques, accurate characterization is obtained for relative jitter with a standard deviation as high as several times the pulse duration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical studies of X-ray sources with the MASCOT - A charge-coupled device /CCD/-based astronomical instrument

The performance levels achieved by the MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes) on the 1.3-m telescope at the McGraw-Hill observatory in March 1981 are discussed along with preliminary data obtained in searches for optical counterparts to four 'empty-field' X-ray sources. In the W band (4000-7000 A), the MASCOT achieved a sky-limited sensitivity of +24.4 mag per sq arcsec in an 1800 s integration. The ability to flatten pictures to a level consistent with (sky + source) photon statistics and readout noise was demonstrated. For the four sources observed, an optical counterpart was established for one source (1413+13) based on positional coincidence (better than 1.8 arcsec), four possible candidates were detected in the error box of another source (1009?35) and upper sensitivity limits were established for optical counterparts in the error boxes for the other two sources (0920+39 and 0931-11).

Ricker, G. R.↗

Reflection Effects in Multimode Fiber Systems Utilizing Laser Transmitters

A number of optical communication lines are now in use at NASA-Kennedy for the transmission of voice, computer data, and video signals. Now, all of these channels use a single carrier wavelength centered near 1300 or 1550 nm. Engineering tests in the past have given indications of the growth of systematic and random noise in the RF spectrum of a fiber network as the number of connector pairs is increased. This noise seems to occur when a laser transmitter is used instead of a LED. It has been suggested that the noise is caused by back reflections created at connector fiber interfaces. Experiments were performed to explore the effect of reflection on the transmitting laser under conditions of reflective feedback. This effort included computer integration of some of the instrumentation in the fiber optic lab using the Lab View software recently acquired by the lab group. The main goal was to interface the Anritsu Optical and RF spectrum analyzers to the MacIntosh II computer so that laser spectra and network RF spectra could be simultaneously and rapidly acquired in a form convenient for analysis. Both single and multimode fiber is installed at Kennedy. Since most are multimode, this effort concentrated on multimode systems.

Bates, Harry E.↗

Using AI for Wave-front Estimation with the Rubin Observatory Active Optics System

Abstract The Vera C. Rubin Observatory will, over a period of 10 yr, repeatedly survey the southern sky. To ensure that images generated by Rubin meet the quality requirements for precision science, the observatory will use an active-optics system (AOS) to correct for alignment and mirror surface perturbations introduced by gravity and temperature gradients in the optical system. To accomplish this, Rubin will use out-of-focus images from sensors located at the edge of the focal plane to learn and correct for perturbations to the wave front. We have designed and integrated a deep-learning (DL) model for wave-front estimation into the AOS pipeline. In this paper, we compare the performance of this DL approach to Rubin’s baseline algorithm when applied to images from two different simulations of the Rubin optical system. We show the DL approach is faster and more accurate, achieving the atmospheric error floor both for high-quality images and low-quality images with heavy blending and vignetting. Compared to the baseline algorithm, the DL model is 40× faster, the median error 2× better under ideal conditions, 5× better in the presence of vignetting by the Rubin camera, and 14× better in the presence of blending in crowded fields. In addition, the DL model surpasses the required optical quality in simulations of the AOS closed loop. This system promises to increase the survey area useful for precision science by up to 8%. We discuss how this system might be deployed when commissioning and operating Rubin.

79 ASTRONOMY AND ASTROPHYSICS↗

US Participation in the GOME and SCIAMACHY Projects

The research performed during this reporting period includes development and maintenance of scientific software for the GOME retrieval algorithms, consultation on operational software development for GOME, further sensitivity and instrument studies to help finalize the definition of the SCIAMACHY instrument, and consultation on optical and detector issues for both GOME and SCIAMACHY. The Global Ozone Monitoring Experiment was successfully launched on the ERS-2 satellite on April 20, 1995, during this reporting period, and is working in the expected fashion. The European Space Agency has made their selections from responses to the Announcement of Opportunity for GOME validation and science studies, part of the overall ERS AO. The Smithsonian Astrophysical Observatory (SAO) proposal has been selected. These proposals are primarily for access to the data; ESA does not provide research funding for the selected investigations. The SAO activities that are carried out as a result of selection by ESA are funded by the present grant, to the limit that can be accomplished at the present level of funding. SCIAMACHY is currently in Phase C/D. Instrument design is almost finalized and selection of infrared detectors from the initial production run has been made.

Chance, K. V.↗

THE ABUNDANCE PATTERN IN THE HOT ISM OF NGC 4472: INSIGHTS AND ANOMALIES

Important clues to the chemical and dynamical history of elliptical galaxies are encoded in the abundances of heavy elements in the X-ray emitting plasma. We derive the hot interstellar medium abundance pattern in inner (0-2.3 R{sub e}) and outer (2.3-4.6R{sub e}) regions of NGC 4472 from analysis of Suzaku spectra, supported by analysis of co-spatial XMM-Newton spectra. The low background and relatively sharp spectral resolution of the Suzaku X-ray Imaging Spectrometer detectors, combined with the high luminosity and temperature in NGC 4472, enable us to derive a particularly extensive abundance pattern that encompasses O, Ne, Mg, Al, Si, S, Ar, Ca, Fe, and Ni in both regions. We apply simple chemical evolution models to these data and conclude that the abundances are best explained by a combination of {alpha}-element enhanced stellar mass loss and direct injection of Type Ia supernova (SNIa) ejecta. We thus confirm the inference, based on optical data, that the stars in elliptical galaxies have supersolar [{alpha}/Fe] ratios, but find that that the present-day SNIa rate is {approx}4-6 times lower than the standard value. We find SNIa yield sets that reproduce Ca and Ar, or Ni, but not all three simultaneously. The low abundance of O relative to Ne and Mg implies that standard core collapse nucleosynthesis models overproduce O by {approx}2.

79 ASTRONOMY AND ASTROPHYSICS↗