Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modal test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

THE ABUNDANCE OF BULLET GROUPS IN ΛCDM

We estimate the expected distribution of displacements between the two dominant dark matter (DM) peaks (DM-DM displacements) and between the DM and gaseous baryon peak (DM-gas displacements) in DM halos with masses larger than 10{sup 13} h {sup –1} M {sub ☉}. As a benchmark, we use the observation of SL2S J08544–0121, which is the lowest mass system (1.0 × 10{sup 14} h {sup –1} M {sub ☉}) observed so far, featuring a bi-modal DM distribution with a dislocated gas component. We find that (50 ± 10)% of the DM halos with circular velocities in the range 300-700 km s{sup –1} (groups) show DM-DM displacements equal to or larger than 186 ± 30 h {sup –1} kpc as observed in SL2S J08544–0121. For DM halos with circular velocities larger than 700 km s{sup –1} (clusters) this fraction rises to (70 ± 10)%. Using the same simulation, we estimate the DM-gas displacements and find that 0.1%-1.0% of the groups should present separations equal to or larger than 87 ± 14 h {sup –1} kpc, corresponding to our observational benchmark; for clusters, this fraction rises to (7 ± 3)%, consistent with previous studies of DM to baryon separations. Considering both constraints on the DM-DM and DM-gas displacements, we find that the number density of groups similar to SL2S J08544–0121 is ∼6.0 × 10{sup –7} Mpc{sup –3}, three times larger than the estimated value for clusters. These results open up the possibility for a new statistical test of ΛCDM by looking for DM-gas displacements in low mass clusters and groups.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicted and Measured Modal Sound Power Levels for a Fan Ingesting Distorted Inflow

Refinements have been made to a method for estimating the modal sound power levels of a ducted fan ingesting distorted inflow. By assuming that each propagating circumferential mode consists only of a single radial mode (the one with the highest cut-off ratio), circumferential mode sound power levels can be computed for a variety of inflow distortion patterns and operating speeds. Predictions from the refined theory have been compared to data from an experiment conducted in the Advanced Noise Control Fan at NASA Glenn Research Center. The inflow to the fan was distorted by inserting cylindrical rods radially into the inlet duct. The rods were placed at an axial location one rotor chord length upstream of the fan and arranged in both regular and irregular circumferential patterns. The fan was operated at 2000, 1800, and 1400 rpm. Acoustic pressure levels were measured in the fan inlet and exhaust ducts using the Rotating Rake fan mode measurement system. Far field sound pressure levels were also measured. It is shown that predicted trends in circumferential mode sound power levels closely match the experimental data for all operating speeds and distortion configurations tested. Insight gained through this work is being used to develop more advanced tools for predicting fan inflow distortion tone noise levels.

Koch, L. Danielle↗

IVGen Mini Techport May 2024

Intravenous (IV) fluids are an important treatment modality for multiple medical conditions that have the potential to occur during Mars missions and that may lead to adverse crew health and mission outcomes without appropriate treatment. However, carrying sufficient volumes of IV fluids with adequate shelf life to support such missions is currently not feasible due to anticipated mass and volume constraints of future vehicles and the relatively short shelf-life of terrestrial IV fluids. The goal of the IntraVenous Fluid Generation for Exploration Missions, Miniaturized, (IVGen Mini) project is to develop a low mass and volume IV fluid generation device that can produce IV fluids in situ and that reduces the need to launch and store large quantities of IV fluids. It builds on the original IVGEN system developed by the Human Research Program’s Exploration Medical Capability Element that successfully demonstrated the capability to produce in-situ IV fluids aboard the ISS in 2010 using an ISS potable water source. Flight demonstration objectives for this system included purification via packed bed resin, bubble removal, sterilization, passive mixing in microgravity, and United States Pharmacopeia (USP) tested compliance. The project will culminate in a flight technical demonstration on the ISS in 2025/2026.

Courtney M Schkurko↗

Development of a Dynamically Configurable, Object-Oriented Framework for Distributed, Multi-modal Computational Aerospace Systems Simulation: Second Year Progress Report

Mesh generation has long been recognized as a bottleneck in the CFD process. While much research on automating the volume mesh generation process have been relatively successful,these methods rely on appropriate initial surface triangulation to work properly. Surface discretization has been one of the least automated steps in computational simulation due to its dependence on implicitly defined CAD surfaces and curves. Differences in CAD peometry engines manifest themselves in discrepancies in their interpretation of the same entities. This lack of "good" geometry causes significant problems for mesh generators, requiring users to "repair" the CAD geometry before mesh generation. The problem is exacerbated when CAD geometry is translated to other forms (e.g., IGES )which do not include important topological and construction information in addition to entity geometry. One technique to avoid these problems is to access the CAD geometry directly from the mesh generating software, rather than through files. By accessing the geometry model (not a discretized version) in its native environment, t h s a proach avoids translation to a format which can deplete the model of topological information. Our approach to enable models developed in the Denali software environment to directly access CAD geometry and functions is through an Application Programming Interface (API) known as CAPRI. CAPRI provides a layer of indirection through which CAD-specific data may be accessed by an application program using CAD-system neutral C and FORTRAN language function calls. CAPRI supports a general set of CAD operations such as truth testing, geometry construction and entity queries.

Afjeh, Abdollah A.↗

A dual modality phantom for cone beam CT and ultrasound image fusion in prostate implant

In transrectal ultrasound (TRUS) guided prostate seed brachytherapy, TRUS provides good delineation of the prostate while x-ray imaging, e.g., C-arm, gives excellent contrast for seed localization. With the recent availability of cone beam CT (CBCT) technology, the combination of the two imaging modalities may provide an ideal system for intraoperative dosimetric feedback during implantation. A dual modality phantom made of acrylic and copper wire was designed to measure the accuracy and precision of image coregistration between a C-arm based CBCT and 3D TRUS. The phantom was scanned with TRUS and CBCT under the same setup condition. Successive parallel transverse ultrasound (US) images were acquired through manual stepping of the US probe across the phantom at an increment of 1 mm over 7.5 cm. The CBCT imaging was done with three reconstructed slice thicknesses (0.4, 0.8, and 1.6 mm) as well as at three different tilt angles (0 deg., 15 deg., 30 deg. ), and the coregistration between CBCT and US images was done using the Variseed system based on four fiducial markers. Fiducial localization error (FLE), fiducial registration error (FRE), and target registration error (TRE) were calculated for all registered image sets. Results showed that FLE were typically less than 0.4 mm, FRE were less than 0.5 mm, and TRE were typically less than 1 mm within the range of operation for prostate implant (i.e., <6 cm to surface of US probe). An analysis of variance test showed no significant difference in TRE for the CBCT-US fusion among the three slice thicknesses (p=0.37). As a comparison, the experiment was repeated with a US-conventional CT scanner combination. No significant difference in TRE was noted between the US-conventional CT fusion and that for all three CBCT image slice thicknesses (p=0.21). CBCT imaging was also performed at three different C-arm tilt angles of 0 deg., 15 deg., and 30 deg. and reconstructed at a slice thickness of 0.8 mm. There is no significant difference in TRE between 0 deg. and 15 deg. (p=0.191) as well as between 0 deg. and 30 deg. (p=0.275), which suggests that the C-arm may be tilted intraoperatively to acquire CBCT images without compromising the quality of image fusion. The results conclude a high degree of accuracy and precision for the CBCT-TRUS fusion, which could be useful toward achieving real time intraoperative dosimetry in prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancement of flow measurements using fluid-dynamic constraints

Novel experimental modalities acquire spatially resolved velocity measurements for steady state and transient flows which are of interest for engineering and biological applications. One of the drawbacks of such high resolution velocity data is their susceptibility to measurement errors. In this paper, we propose a novel filtering strategy that allows enhancement of the noisy measurements to obtain reconstruction of smooth divergence free velocity and corresponding pressure fields which together approximately comply to a prescribed flow model. The main step in our approach consists of the appropriate use of the velocity measurements in the design of a linearized flow model which can be shown to be well-posed and consistent with the true velocity and pressure fields up to measurement and modeling errors. The reconstruction procedure is then formulated as an optimal control problem for this linearized flow model. The resulting filter has analyzable smoothing and approximation properties. We briefly discuss the discretization of the approach by finite element methods and comment on the efficient solution by iterative methods. The capability of the proposed filter to significantly reduce data noise is demonstrated by numerical tests including the application to experimental data. In addition, we compare with other methods like smoothing and solenoidal filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-QI-15: Single Point Dosimetry by Means of Cerenkov Radiation Energy Transfer (CRET)

Purpose: Cerenkov light is generated when a charged particles with energy greater then 250 keV, moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons during the static megavoltage linear accelerator (LINAC) operational mode. Recently, Cerenkov radiation gained considerable interest as possible candidate as a new imaging modality. Optical signals generated by Cerenkov radiation may act as a surrogate for the absorbed superficial radiation dose. We demonstrated a novel single point dosimetry method for megavoltage photon and electron therapy utilizing down conversion of Cerenkov photons. Methods: The custom build signal characterization system was used: a sample holder (probe) with adjacent light tight compartments was connected via fiber-optic cables to a photon counting photomultiplier tube (PMT). One compartment contains a medium only while the other contains medium and red-shifting nano-particles (Q-dots, nanoclusters). By taking the difference between the two signals (Cerenkov photons and CRET photons) we obtain a measure of the down-converted light, which we expect to be proportional to dose as measured with an adjacent ion chamber. Experimental results are compared to Monte Carlo simulations performed using the GEANT4 code. Results: The signal correlation between CR signal, CRET readings and dose produced by LINAC at a single point were investigated. The experimental results were compared with simulations. The dose linearity, signal to noise ratio and dose rate dependence were tested with custom build CRET based probe. Conclusion: Performance characteristics of the proposed single point CRET based probe were evaluated. The direct use of the induced Cerenkov emission and CRET in an irradiated single point volume as an indirect surrogate for the imparted dose was investigated. We conclude that CRET is a promising optical based dosimetry method that offers advantages over those already proposed.

60 APPLIED LIFE SCIENCES↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

FY 2026 Midyear Report: Seismic Monitoring of Underground Vibration Sources Using Distributed Acoustic Sensing and Seismometers

Safeguards-relevant temporal changes in underground facilities can be observed using geophysical monitoring techniques. Seismic waves, in particular, provide valuable insights into subsurface activities and can serve as an important tool for detecting anomalous events that may indicate containment breaches at geological repositories. This midyear report summarizes ongoing efforts to automatically and rapidly detect and locate anomalous vibration signals that could be indicative of potential containment breaches. Previous work during FY25 focused on compiling continuous seismic datasets from two underground sites and developing a database of continuous waveforms and ground-truth event data derived from multiple sensing modalities. Building on this foundation, we are adapting anomaly detection and geolocation algorithms to explore methods for monitoring underground activities using two relatively low-maintenance sensing technologies: a dense surface geophone array deployed at the Pleasant Gap mine in Pennsylvania, and a three-dimensional fiber-optic cable array for distributed acoustic sensing (DAS) installed in the subsurface at the Sanford Underground Research Facility (SURF) in South Dakota. This report summarizes work conducted during the first two quarters of FY26, during which we refined a dynamic power spectral density (PSD)-based detector, applied it independently to each geophone station, and then combined the per‑station detections with density-based spatial clustering of applications with noise (DBSCAN) to cluster events and produce spatial maps over a nine‑day interval. In addition, we outline plans for a field trial at the Waste Isolation Pilot Plant (WIPP) in New Mexico to compare traditional seismic monitoring approaches with DAS techniques and to evaluate the benefits of combined data analysis. Activities during the past two quarters have included the preparation and submission of a Field Test Plan to WIPP for approval, as well as submission to headquarters for review and feedback.

58 GEOSCIENCES↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Reduced order models for thermal analysis : final report : LDRD Project No. 137807.

This LDRD Senior's Council Project is focused on the development, implementation and evaluation of Reduced Order Models (ROM) for application in the thermal analysis of complex engineering problems. Two basic approaches to developing a ROM for combined thermal conduction and enclosure radiation problems are considered. As a prerequisite to a ROM a fully coupled solution method for conduction/radiation models is required; a parallel implementation is explored for this class of problems. High-fidelity models of large, complex systems are now used routinely to verify design and performance. However, there are applications where the high-fidelity model is too large to be used repetitively in a design mode. One such application is the design of a control system that oversees the functioning of the complex, high-fidelity model. Examples include control systems for manufacturing processes such as brazing and annealing furnaces as well as control systems for the thermal management of optical systems. A reduced order model (ROM) seeks to reduce the number of degrees of freedom needed to represent the overall behavior of the large system without a significant loss in accuracy. The reduction in the number of degrees of freedom of the ROM leads to immediate increases in computational efficiency and allows many design parameters and perturbations to be quickly and effectively evaluated. Reduced order models are routinely used in solid mechanics where techniques such as modal analysis have reached a high state of refinement. Similar techniques have recently been applied in standard thermal conduction problems e.g. though the general use of ROM for heat transfer is not yet widespread. One major difficulty with the development of ROM for general thermal analysis is the need to include the very nonlinear effects of enclosure radiation in many applications. Many ROM methods have considered only linear or mildly nonlinear problems. In the present study a reduced order model is considered for application to the combined problem of thermal conduction and enclosure radiation. The main objective is to develop a procedure that can be implemented in an existing thermal analysis code. The main analysis objective is to allow thermal controller software to be used in the design of a control system for a large optical system that resides with a complex radiation dominated enclosure. In the remainder of this section a brief outline of ROM methods is provided. The following chapter describes the fully coupled conduction/radiation method that is required prior to considering a ROM approach. Considerable effort was expended to implement and test the combined solution method; the ROM project ended shortly after the completion of this milestone and thus the ROM results are incomplete. The report concludes with some observations and recommendations.

42 ENGINEERING↗

A quality assurance program for image quality of cone-beam CT guidance in radiation therapy

The clinical introduction of volumetric x-ray image-guided radiotherapy systems necessitates formal commissioning of the hardware and image-guided processes to be used and drafts quality assurance (QA) for both hardware and processes. Satisfying both requirements provides confidence on the system's ability to manage geometric variations in patient setup and internal organ motion. As these systems become a routine clinical modality, the authors present data from their QA program tracking the image quality performance of ten volumetric systems over a period of 3 years. These data are subsequently used to establish evidence-based tolerances for a QA program. The volumetric imaging systems used in this work combines a linear accelerator with conventional x-ray tube and an amorphous silicon flat-panel detector mounted orthogonally from the accelerator central beam axis, in a cone-beam computed tomography (CBCT) configuration. In the spirit of the AAPM Report No. 74, the present work presents the image quality portion of their QA program; the aspects of the QA protocol addressing imaging geometry have been presented elsewhere. Specifically, the authors are presenting data demonstrating the high linearity of CT numbers, the uniformity of axial reconstructions, and the high contrast spatial resolution of ten CBCT systems (1-2 mm) from two commercial vendors. They are also presenting data accumulated over the period of several months demonstrating the long-term stability of the flat-panel detector and of the distances measured on reconstructed volumetric images. Their tests demonstrate that each specific CBCT system has unique performance. In addition, scattered x rays are shown to influence the imaging performance in terms of spatial resolution, axial reconstruction uniformity, and the linearity of CT numbers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-FG-BRA-12: Research Work of the Radio-Dynamic Treatment Mechanism

Purpose: The finite penetration depth of Laser light has limited clinical applications for PDT. This present work investigates the activation of photosensitizers using Cerenkov light emission from 45MV photon beams produced in an LA45 cancer therapy accelerator. We have named this new treatment technique Radio-Dynamic Therapy (RDT). Methods: Monte Carlo simulations were made on various Cerenkov emission energies and their spectroscopy in excited target areas in order to estimate their photosensitizer inner activation efficiency. The Cerenkov light excitation efficiency used in RDT has been theoretically compared with the exotic excitation efficiency of external Laser light used in PDT. In addition, laboratory tests showed the differences of the excitation efficiencies between a patented catalyst coenzyme added as a substrate, and then without the coenzyme. A specific probe of DMA (Singlet Oxygen fluorescent probe-9, 10-dimethylanthracene) was also used to detect singlet oxygen. Finally, we also compared our results with similar previous experimental work reported in the scientific literature. Results: Our Monte Carlo results showed that the Cerenkov light intensity induced with 45MV beams from an LA45 is 8 – 10 times the Cerenkov light intensity induced with 6MV beams from conventional accelerators. Furthermore, the patented catalyst coenzyme enhanced the excitation efficiency of photosensitizers by 3–6 times under different conditions. In clinical situations, the new RDT technique also showed favorable outcomes for early and late stages of specific cancers and it is also good at metastatic cancer treatment. Conclusion: Our results indicated that the process of using the Cerenkov light emission to excite photosensitizers from 45MV photons has a similar process and efficiency as the conventional laser in PDT. Comparing the advantages of RDT with a conventional PDT, the RDT may be developed into a potential treatment modality for a wider range of cancers stages as well as for other diseases.

60 APPLIED LIFE SCIENCES↗

A spectral Galerkin method for the coupled Orr-Sommerfeld and induction equations for free-surface MHD.

We develop and test spectral Galerkin schemes to solve the coupled Orr-Sommerfeld and induction equations for parallel, incompressible MHD in free-surface and fixed-boundary geometries. The schemes discrete bases consist of Legendre internal shape functions, supplemented with nodal shape functions for the weak imposition of the stress and insulating boundary conditions. The orthogonality properties of the basis polynomials solve the matrix-coefficient growth problem, and eigenvalue-eigenfunction pairs can be computed stably at spectral orders at least as large as p=3000 with p-independent roundoff error. Accuracy is limited instead by roundoff sensitivity due to non-normality of the stability operators at large hydrodynamic and/or magnetic Reynolds numbers (Re,Rm {ge} 4 x 10{sup 4}). In problems with Hartmann velocity and magnetic-field profiles we employ suitable Gauss quadrature rules to evaluate the associated exponentially weighted sesquilinear forms without error. An alternative approach, which involves approximating the forms by means of Legendre-Gauss-Lobatto quadrature at the 2p?1 precision level, is found to yield equal eigenvalues within roundoff error. As a consistency check, we compare modal growth rates to energy growth rates in nonlinear simulations and record relative discrepancy smaller than 10{sup -5} for the least stable mode in free-surface flow at Re = 3 x 10{sup 4}. Moreover, we confirm that the computed normal modes satisfy an energy conservation law for free-surface MHD with error smaller than 10{sup -6}. The critical Reynolds number in free-surface MHD is found to be sensitive to the magnetic Prandtl number Pm, even at the Pm=O(10{sup -5}) regime of liquid metals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Autonomous 3D and Radiation Mapping in Tunnel Environments Using Aerial Robots - 18156

In this paper we present the algorithms and systems developed to enable autonomous 3D and radiation mapping, as well as radiological source localization in tunnel environments using aerial robots. The developed technologies aim to address the need of autonomous robotic inspection of nuclear sites such as facilities in the process of being decommissioned. As a motivational example, the PUREX tunnels at the Hanford Site are considered and the robot is designed to be able to conduct multi-modal 3D/radiation characterization of the tunnel environment without any prior knowledge or map provided beforehand. In order to enable the necessary GPS-denied simultaneous localization and mapping in dark, visually-degraded tunnel environments, a multi-modal mapping unit was developed which fuses the data from stereo vision cameras synchronized with flashing LEDs, inertial sensors, and three time-of-flight 3D depth sensors. The robot's pose and surrounding map are estimated at 20 Hz through a depth-enhanced visual- inertial localization and mapping framework. Provided this ability to estimate the robot's pose and develop a dense map in real-time, a receding horizon sampling-based autonomous exploration path planning algorithm was utilized and equips the robot with the ability to explore its environment given no prior map. The aforementioned key robotic functionalities are further extended through the integration of miniaturized fully solid-state scintillation detectors, utilizing advanced scintillators and Silicon Photomultipliers. The derived sensor data is employed for radiation mapping, which when fused with the 3D maps and the spectroscopic source localization methods, allow the aerial robotic platform to localize the radiation source and identify the specific source isotope. The source location is estimated through a geometric algorithm which can localize a source given only three measurements and short dwell times. The developed systems were tested using two small aerial robot platforms of the F450 and F550 frame classes with weights of 2.6 kg and 2.9 kg respectively. All localization and planning as well as high-level control algorithms are executed onboard. The scintillation detector is integrated on the robot and its data is collected through a dedicated microcontroller. A set of field experiments were conducted inside the dark and GPS-denied environment of a 4.25 m wide, 7.5 m tall, and 137 m long railroad tunnel. A Cs-137 source was placed within the tunnel, the associated 3D/radiation maps were derived, and the source location was estimated. Through these efforts, the goal is to develop the robotic technology that would enable the autonomous systematic inspection or emergency response in nuclear waste decommissioning facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cascading economic losses from port disruptions under capacity constrained multimodal freight networks

This study quantifies how throughput disruptions at major seaports cascade through capacity-constrained multimodal freight networks and interregional production systems. We couple an agent-based model (ABM) multimodal freight simulation that resolves rerouting, terminal queueing, and inventory drawdown under binding modal and facility capacities with a multiregional output loss input-output (MRIIM) model that propagates realized delivery shortfalls across regions and sectors. The framework is demonstrated for the Port of Los Angeles using Freight Analysis Framework flows and Bureau of Economic Analysis input-output accounts and is evaluated over a 52-week horizon under deterministic sector targeted shocks and stochastic disruption realizations with uncertain severity and duration. Results indicate nonlinear amplification: realized national losses concentrate in manufacturing and transportation/warehousing even when exogenous port shocks are dispersed, suggesting that congestion spillback and limited short-run substitution can dominate the initial shock allocation. We further evaluate a tabular reinforcement-learning (Q-learning) intervention layer that selects among a small set of implementable system level levers (truck-to-rail and truck-to-barge shift settings) without overriding shipper routing, finding that such interventions reduce total losses for moderate disruptions but yield diminishing returns once substitute modes approach capacity. By linking operational freight behavior to system wide impacts under uncertainty, the proposed ABM-MRIIM pipeline provides a reusable workflow for port disruption stress testing, identification of structurally critical sectors/corridors, and evaluation of resilience interventions under realistic capacity limits.

42 ENGINEERING↗

SU-E-T-441: Gamma Passing Rates for IMRT QA and VMAT QA

Purpose: This study compares gamma passing rates for a cohort of similar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA) plans to determine the equivalence of the patient specific QA plan delivery. The passing criterion is 90% gamma index with 3% dose difference (DD), 3mm distance-to-agreement (DTA) and a dose threshold of 10%. Methods: Gamma passing results of previously treated IMRT QA plans, delivered to Sun Nuclear MapCheck phantom, and VMAT QA plans, delivered to ScandiDos Delta4 phantom, are organized by anatomical site and treatment machine. Both Varian and Elekta machines are included. Pairs of IMRT and VMAT plans are matched based on site, machine, and PTV volume to ensure similar plan cohorts. A two-tailed t-test analysis of the data with an alpha of 0.05 determines if there exists a statistically significant difference. Power was calculated to detect a difference of 4%; all data sets were strong with above a 0.8 power. Results: The first data set consisting of 20 matched pairs of prostate plans was statistically insignificant (p-value=0.90, Power=0.99). The 14 matched pairs set of head and neck plans has a statistically significant Result (p-value=0.028, Power=0.88). The head and neck IMRT gamma indexes have a mean of 93.1% and range of 82%-100% while the VMAT gamma indexes have a mean of 96.7% and range of 92%-100%. The two combined data sets of matched plans had a statistically insignificant Result (p-value=0.073, Power=0.99). Conclusion: Overall, IMRT and VMAT have equivalent passing rates when comparing the gamma analysis using a passing criterion of 3% DD and 3mm DTA. When separated by site, prostate IMRT and VMAT plans have equivalent passing rates while head and neck plans have a statistically significant variation of passing rates. The passing rates for the two modalities are independent of delivery machine for matched PTV target volumes.

60 APPLIED LIFE SCIENCES↗

Effect of altered sensory conditions on multivariate descriptors of human postural sway

Multivariate descriptors of sway were used to test whether altered sensory conditions result not only in changes in amount of sway but also in postural coordination. Eigenvalues and directions of eigenvectors of the covariance of shnk and hip angles were used as a set of multivariate descriptors. These quantities were measured in 14 healthy adult subjects performing the Sensory Organization test, which disrupts visual and somatosensory information used for spatial orientation. Multivariate analysis of variance and discriminant analysis showed that resulting sway changes were at least bivariate in character, with visual and somatosensory conditions producing distinct changes in postural coordination. The most significant changes were found when somatosensory information was disrupted by sway-referencing of the support surface (P = 3.2 x 10(-10)). The resulting covariance measurements showed that subjects not only swayed more but also used increased hip motion analogous to the hip strategy. Disruption of vision, by either closing the eyes or sway-referencing the visual surround, also resulted in altered sway (P = 1.7 x 10(-10)), with proportionately more motion of the center of mass than with platform sway-referencing. As shown by discriminant analysis, an optimal univariate measure could explain at most 90% of the behavior due to altered sensory conditions. The remaining 10%, while smaller, are highly significant changes in posture control that depend on sensory conditions. The results imply that normal postural coordination of the trunk and legs requires both somatosensory and visual information and that each sensory modality makes a unique contribution to posture control. Descending postural commands are multivariate in nature, and the motion at each joint is affected uniquely by input from multiple sensors.

NASA Discipline Neuroscience↗