Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linearity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A mixed integer linear programming approach for the design of chemical process families

Tackling climate change goals requires widespread deployment of process technology variants across many decentralized sites with different geographical, environmental, and operational requirements. Conventional engineering approaches focus on unique designs for each installation (process variant), while missing opportunities for manufacturing standardization. Here, instead we seek to optimize a process platform of common unit designs while simultaneously designing an entire family of process variants that make use of that platform. This reduces engineering effort, deployment timelines, and manufacturing costs. We propose a nonlinear generalized disjunctive programming formulation and convert this to an efficient mixed-integer linear programming (MILP) formulation through discretization of the design space. We formulate our optimization in Pyomo with costing from IDAES, and we demonstrate the computational performance and solution quality on a water treatment desalination system from the PARETO framework and a carbon capture system built in Aspen Plus as part of CCSI2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of temperature and time on supercritical methanol Co-Liquefaction of rice straw and linear low-density polyethylene wastes

We report that biofuels are particularly attractive and play an increasingly important role in sustainable energy. However, biofuels originating from lignocellulosic biomass (LCB) are extremely challenging because of their low carbon content, low stability, and high oxygen content. This work evaluates the supercritical methanol (scMeOH) co-liquefaction of rice straw and linear low-density polyethylene (LLDPE) at temperature range of 240-340 °C for 0-2 h, to obtain hydrocarbons (HCs)-rich oil and carbon-rich solid product. Results show that reaction temperature dominated the yield and properties of products, but not the holding time. Among parameters tested, 30.07 wt% oil yield with 75.79% HCs content and 33.05 wt% oil yield with 70.91% HCs content were obtained at 300 °C for 1 h and 1.5 h, respectively. Simultaneously, the remaining solid products were still as high as 53.85 wt% with a carbon content of 79.59% and 48.28 wt% with carbon content of 81.34% under 300 °C for 1 h and 1.5 h, respectively. Ultimate analysis, FT-IR, TGA, and SEM show that solid products could be used as sustainable carbon resources, and solid fuel rather than soil amendment because of risk of micro plastic or adsorbent due to smooth surface without pores.

09 BIOMASS FUELS↗

Application of Box-Behnken design in optimizing product properties of supercritical methanol co -liquefaction of rice straw and linear low-density polyethylene

We report co-processing of plastic and biomass wastes to produce high-quality fuel has been attracting considerable interest in energy recovery. This work employed Box-Behnken Design (BBD) to optimize yield and properties of oil from supercritical methanol (scMeOH) co-liquefaction of rice straw (RS) and linear low-density polyethylene (LLDPE). Three independent variables of reaction temperature (270, 300, and 330°C), holding time (60, 90, and 120 mins), and RS/LLDPE mass ratio (0.15, 0.50, and 0.85) were selected for experiments. A maximum oil yield of 34.17 wt% was achieved at 303°C, 96 mins, and RS/LLDPE ratio of 0.59 according to BBD. Temperature and RS/LLDPE ratio dominated the oil yield and synergistic effects during co-liquefaction, whereas time was an insignificant factor. Optimum oil from co-liquefaction contained substantial hydrocarbons content of 32.91% compared to that from single RS-derived oil of 7.77%. Solid product obtained at the optimum condition could be used as solid fuel, due to its relatively high HHV of 43.08 MJ/kg compared to the other solid fuels (13.90–32.14 MJ/kg). This work provides a deep understanding of the co-processing of solid biomass and plastic wastes.

09 BIOMASS FUELS↗

Alternative mixed integer linear programming optimization for joint job scheduling and data allocation in grid computing

This paper presents a novel approach to the joint optimization of job scheduling and data allocation in grid computing environments. We formulate this joint optimization problem as a mixed integer quadratically constrained program. To tackle the nonlinearity in the constraint, we alternatively fix a subset of decision variables and optimize the remaining ones via Mixed Integer Linear Programming (MILP). We solve the MILP problem at each iteration via an off-the-shelf MILP solver. Our experimental results show that our method significantly outperforms existing heuristic methods, employing either independent optimization or joint optimization strategies. We have also verified the generalization ability of our method over grid environments with various sizes and its high robustness to the algorithm setting.

97 MATHEMATICS AND COMPUTING↗

Tuning successive linear programming to solve AC optimal power flow problem for large networks

Successive linear programming (SLP) is a practical approach for solving large-scale nonlinear optimization problems. Alternating current optimal power flow (ACOPF) is no exception, particularly the large size of real-world networks. However, in order to achieve tractability, it is essential to tune the SLP algorithm presented in the literature. This paper presents a modified SLP algorithm to solve the ACOPF problem, specified by the U.S. Department of Energy’s (DOE) Grid Optimization (GO) Competition Challenge 1, within strict time limits. The algorithm first finds a near-optimal solution for the relaxed problem (i.e., Stage 1). Then, it finds a feasible solution in the proximity of the near-optimal solution (i.e., Stage 2 and Stage 3). The numerical experiments on test cases ranging from 500-bus to 30,000-bus systems show that the algorithm is tractable. Here the results show that our proposed algorithm is tractable and can solve more than 80% of test cases faster than the well-known Interior Point Method while significantly reduce the number of iterations required to solve ACOPF. The number of iterations is considered an important factor in the examination of tractability which can drastically reduce the computational time required within each iteration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linear Accelerator and Gamma Knife-Based Stereotactic Cranial Radiosurgery: Challenges and Successes of Existing Quality Assurance Guidelines and Paradigms

Intracranial stereotactic radiosurgery has been practiced since 1951. The technique has expanded from a single dedicated unit in Stockholm in 1968 to hundreds of centers performing an estimated 100,000 Gamma Knife and linear accelerator cases in 2005. The radiation dosimetry of small photon fields used in this technique has been well explored in the past 15 years. Quality assurance recommendations have been promulgated in refereed reports and by several national and international professional societies since 1991. The field has survived several reported treatment errors and incidents, generally reacting by strengthening standards and precautions. An increasing number of computer-controlled and robotic-dedicated treatment units are expanding the field and putting patients at risk of unforeseen errors. Revisions and updates to previously published quality assurance documents, and especially to radiation dosimetry protocols, are now needed to ensure continued successful procedures that minimize the risk of serious errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complications Following Linear Accelerator Based Stereotactic Radiation for Cerebral Arteriovenous Malformations

Purpose: Primarily, gamma knife centers are predominant in publishing results on arteriovenous malformations (AVM) treatments including reports on risk profile. However, many patients are treated using a linear accelerator-most of these at smaller centers. Because this setting is different from a large gamma knife center, the risk profile at Linac departments could be different from the reported experience. Prescribed radiation doses are dependent on AVM volume. This study details results from a medium sized Linac department center focusing on risk profiles. Method and Materials: A database was searched for all patients with AVMs. We included 50 consecutive patients with a minimum of 24 months follow-up (24-51 months). Results: AVM occlusion was verified in 78% of patients (39/50). AVM occlusion without new deficits (excellent outcome) was obtained in 44%. Good or fair outcome (AVM occlusion with mild or moderate new deficits) was seen in 30%. Severe complications after AVM occlusion occurred in 4% with a median interval of 15 months after treatment (range, 1-26 months). Conclusions: We applied an AVM grading score developed at the Mayo Clinic to predict probable outcome after radiosurgery in a large patient population treated with Gamma knife. A cutoff above and below a score of 1.5 could not discriminate between the likelihood of having an excellent outcome (approximately 45%). The chance of having an excellent or good outcome was slightly higher in patients with an AVM score below 1.5 (64% vs. 57%).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irradiated Volume as a Predictor of Brain Radionecrosis After Linear Accelerator Stereotactic Radiosurgery

Purpose: To investigate the correlation between volume of brain irradiated by stereotactic radiosurgery (SRS) and the incidence of symptomatic and asymptomatic brain radionecrosis (RN). Methods and Materials: A retrospective analysis was performed of patients treated with single-fraction SRS for brain metastases at our institution. Patients with at least 6-month imaging follow-up were included and diagnosed with RN according to a combination of criteria, including appearance on serial imaging and histology. Univariate and multivariate analyses were performed to determine the predictive value of multiple variables, including volume of brain receiving a specific dose (V8 Gy-V18 Gy). Results: Sixty-three patients were reviewed, with a total of 173 lesions. Most patients (63%) had received previous whole-brain irradiation. Mean prescribed SRS dose was 18 Gy. Symptomatic RN was observed in 10% and asymptomatic RN in 4% of lesions treated. Multivariate regression analysis showed V8 Gy-V16 Gy to be most predictive of symptomatic RN (p < 0.0001). Threshold volumes for significant rise in RN rates occurred between the 75th and 90th percentiles, with a midpoint volume of 10.45 cm{sup 3} for V10 Gy and 7.85 cm{sup 3} for V12 Gy. Conclusions: Analysis of patient and treatment variables revealed V8 Gy-V16 Gy to be the best predictors for RN using linear accelerator-based single-fraction SRS for brain metastases. We propose that patients with V10 Gy >10.5 cm{sup 3} or V12 Gy >7.9 cm{sup 3} be considered for hypofractionated rather than single-fraction treatment, to minimize the risk of symptomatic RN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hippocampal-Sparing Whole-Brain Radiotherapy: A 'How-To' Technique Using Helical Tomotherapy and Linear Accelerator-Based Intensity-Modulated Radiotherapy

Purpose: Sparing the hippocampus during cranial irradiation poses important technical challenges with respect to contouring and treatment planning. Herein we report our preliminary experience with whole-brain radiotherapy using hippocampal sparing for patients with brain metastases. Methods and Materials: Five anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. The hippocampus was contoured, and hippocampal avoidance regions were created using a 5-mm volumetric expansion around the hippocampus. Helical tomotherapy and linear accelerator (LINAC)-based intensity-modulated radiotherapy (IMRT) treatment plans were generated for a prescription dose of 30 Gy in 10 fractions. Results: On average, the hippocampal avoidance volume was 3.3 cm{sup 3}, occupying 2.1% of the whole-brain planned target volume. Helical tomotherapy spared the hippocampus, with a median dose of 5.5 Gy and maximum dose of 12.8 Gy. LINAC-based IMRT spared the hippocampus, with a median dose of 7.8 Gy and maximum dose of 15.3 Gy. On a per-fraction basis, mean dose to the hippocampus (normalized to 2-Gy fractions) was reduced by 87% to 0.49 Gy{sub 2} using helical tomotherapy and by 81% to 0.73 Gy{sub 2} using LINAC-based IMRT. Target coverage and homogeneity was acceptable with both IMRT modalities, with differences largely attributed to more rapid dose fall-off with helical tomotherapy. Conclusion: Modern IMRT techniques allow for sparing of the hippocampus with acceptable target coverage and homogeneity. Based on compelling preclinical evidence, a Phase II cooperative group trial has been developed to test the postulated neurocognitive benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimized Doses for Linear Accelerator Radiosurgery of Brainstem Metastasis

Purpose: Treatment of cerebral metastases located inside the brainstem remains a challenge, as the brainstem is considered to be a neurological organ at risk, whatever the treatment strategy. We report a retrospective study of 30 consecutive patients treated in our institution between 2005 and 2007 with micromultileaf linear accelerator (LINAC) -radiosurgery for brainstem metastases, with reduced doses compared to those usually reported in the literature. Methods and Materials: Mean follow-up was 311 days (range, 41-1351). Median age was 57 years (range, 37-82), Mean Karnofsky Index (KI) was 80. Primary tumor site was lung (n = 13), breast (n = 4), kidney (n = 4), skin (melanoma; n = 3), and others (n = 6). Primary tumor was controlled in 17 cases; extracranial metastases were controlled in 12 cases. Mean number of metastases was 1.46 (one to three); median volume was 2.82 cc (0.06-18). Dose was delivered by a micromultileaf collimator 6-MV LINAC . Results: Dose administered at the 70% isodose was 13.4 Gy (range, 8.2-15). Median survival was 10 months. Local control rates at 3, 6, and 12 months were 100%, 100%, and 79% respectively. Median neurological control duration was 5 months. Neurological control rates at 3, 6, and 12 months were 73%, 42%, and 25%, respectively. No parameter was found to significantly correlate with survival, local, or cerebral control. No patients had severe side effects (Grade III-IV), according to the Radiation Therapy Oncology Group (RTOG) scale. Conclusion: Lower doses than previously reported can achieve the same local control and survival rates in brain metastases, with minimal side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dedicated Linear Accelerator Radiosurgery for Trigeminal Neuralgia: A Single-Center Experience in 179 Patients With Varied Dose Prescriptions and Treatment Plans

Purpose: Dedicated linear accelerator radiosurgery (D-LINAC) has become an important treatment for trigeminal neuralgia (TN). Although the use of gamma knife continues to be established, few large series exist using D-LINAC. The authors describe their results, comparing the effects of varied target and dose regimens. Methods and Materials: Between August 1995 and January 2008, 179 patients were treated with D-LINAC radiosurgery. Ten patients (5.58%) had no clinical follow-up. The median age was 74.0 years (range, 32-90 years). A total of 39 patients had secondary or atypical pain, and 130 had idiopathic TN. Initially, 28 patients received doses between 70 and 85 Gy, with the 30% isodose line (IDL) touching the brainstem. Then, using 90 Gy, 82 consecutive patients were treated with a 30% IDL and 59 patients with a 50% IDL tangential to the pons. Results: Of 169 patients, 134 (79.3%) experienced significant relief at a mean of 28.8 months (range, 5-142 months). Average time to relief was 1.92 months (range, immediate to 6 months). A total of 31 patients (19.0%) had recurrent pain at 13.5 months. Of 87 patients with idiopathic TN without prior procedures, 79 (90.8%) had initial relief. Among 28 patients treated with 70 Gy and 30% IDL, 18 patients (64.3%) had significant relief, and 10 (35.7%) had numbness. Of the patients with 90 Gy and 30% IDL at the brainstem, 59 (79.0%) had significant relief and 48.9% had numbness. Among 59 consecutive patients with similar dose but the 50% isodoseline at the brainstem, 49 patients (88.0%) had excellent/good relief. Numbness, averaging 2.49 on a subjective scale of 1 to 5, was experienced by 49.7% of the patients, Conclusions: Increased radiation dose and volume of brainstem irradiation may improve clinical outcomes with the trade-off of trigeminal dysfunction. Further study of the implications of dose and target are needed to optimize outcomes and to minimize complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of Photon Beams of a Flattening Filter-Free Linear Accelerator and the Accuracy of Beam Modeling Using an Anisotropic Analytical Algorithm;TrueBeam; Flattening filter free; Commissioning; Anisotropic analytical algorithm

Purpose: To investigate dosimetric characteristics of a new linear accelerator designed to deliver flattened, as well as flattening filter-free (FFF), beams. To evaluate the accuracy of beam modeling under physical conditions using an anisotropic analytical algorithm. Methods and Materials: Dosimetric data including depth dose curves, profiles, surface dose, penumbra, out-of-field dose, output, total and scatter factors were examined for four beams (X6, X6FFF, X10, and X10FFF) of Varian's TrueBeam machine. Beams modeled by anisotropic analytical algorithm were compared with measured dataset. Results: FFF beams have lower mean energy (tissue-phantom ratio at the depths of 20 and 10 cm (TPR 20/10): X6, 0.667; X6FFF, 0.631; X10, 0.738; X10FFF, 0.692); maximum dose is located closer to the surface; and surface dose increases by 10%. FFF profiles have sharper but faster diverging penumbra. For small fields and shallow depths, dose outside a field is lower for FFF beams; however, the advantage fades with increasing phantom scatter. Output increases 2.26 times for X6FFF and 4.03 times for X10FFF and is less variable with field size; collimator exchange effect is reduced. A good agreement between modeled and measured data is observed. Criteria of 2% depth-dose and 2-mm distance-to-agreement are always met. Conclusion: Reference dosimetric characteristics of TrueBeam photon bundles were obtained, and successful modeling of the beams was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Irradiation of the Postoperative Resection Cavity for Brain Metastasis: A Frameless Linear Accelerator-Based Case Series and Review of the Technique

Purpose: Whole-brain radiation therapy (WBRT) is the standard of care after resection of a brain metastasis. However, concern regarding possible neurocognitive effects and the lack of survival benefit with this approach has led to the use of stereotactic radiosurgery (SRS) to the resection cavity in place of WBRT. We report our initial experience using an image-guided linear accelerator-based frameless stereotactic system and review the technical issues in applying this technique. Methods and Materials: We retrospectively reviewed the setup accuracy, treatment outcome, and patterns of failure of the first 18 consecutive cases treated at Brigham and Women's Hospital. The target volume was the resection cavity without a margin excluding the surgical track. Results: The median number of brain metastases per patient was 1 (range, 1-3). The median planning target volume was 3.49 mL. The median prescribed dose was 18 Gy (range, 15-18 Gy) with normalization ranging from 68% to 85%. In all cases, 99% of the planning target volume was covered by the prescribed dose. The median conformity index was 1.6 (range, 1.41-1.92). The SRS was delivered with submillimeter accuracy. At a median follow-up of 12.7 months, local control was achieved in 16/18 cavities treated. True local recurrence occurred in 2 patients. No marginal failures occurred. Distant recurrence occurred in 6/17 patients. Median time to any failure was 7.4 months. No Grade 3 or higher toxicity was recorded. A long interval between initial cancer diagnosis and the development of brain metastasis was the only factor that trended toward a significant association with the absence of recurrence (local or distant) (log-rank p = 0.097). Conclusions: Frameless stereotactic irradiation of the resection cavity after surgery for a brain metastasis is a safe and accurate technique that offers durable local control and defers the use of WBRT in select patients. This technique should be tested in larger prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators

Purpose: Failure mode and effects analysis (FMEA) represents a prospective approach for risk assessment. A multidisciplinary working group of the Italian Association for Medical Physics applied FMEA to electron beam intraoperative radiation therapy (IORT) delivered using mobile linear accelerators, aiming at preventing accidental exposures to the patient. Methods and Materials: FMEA was applied to the IORT process, for the stages of the treatment delivery and verification, and consisted of three steps: 1) identification of the involved subprocesses; 2) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system, based on the product of three parameters (severity, frequency of occurrence and detectability, each ranging from 1 to 10); 3) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. Results: Twenty-four subprocesses were identified. Ten potential failure modes were found and scored, in terms of RPN, in the range of 42-216. The most critical failure modes consisted of internal shield misalignment, wrong Monitor Unit calculation and incorrect data entry at treatment console. Potential causes of failure included shield displacement, human errors, such as underestimation of CTV extension, mainly because of lack of adequate training and time pressures, failure in the communication between operators, and machine malfunctioning. The main effects of failure were represented by CTV underdose, wrong dose distribution and/or delivery, unintended normal tissue irradiation. As additional safety measures, the utilization of a dedicated staff for IORT, double-checking of MU calculation and data entry and finally implementation of in vivo dosimetry were suggested. Conclusions: FMEA appeared as a useful tool for prospective evaluation of patient safety in radiotherapy. The application of this method to IORT lead to identify three safety measures for risk mitigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Predictive of Symptomatic Radiation Injury After Linear Accelerator-Based Stereotactic Radiosurgery for Intracerebral Arteriovenous Malformations

Purpose: To investigate predictive factors in the development of symptomatic radiation injury after treatment with linear accelerator-based stereotactic radiosurgery for intracerebral arteriovenous malformations and relate the findings to the conclusions drawn by Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC). Methods and Materials: Archived plans for 73 patients who were treated at the British Columbia Cancer Agency were studied. Actuarial estimates of freedom from radiation injury were calculated using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used for analysis of incidence of radiation injury. Log-rank test was used to search for dosimetric parameters associated with freedom from radiation injury. Results: Symptomatic radiation injury was exhibited by 14 of 73 patients (19.2%). Actuarial rate of symptomatic radiation injury was 23.0% at 4 years. Most patients (78.5%) had mild to moderate deficits according to Common Terminology Criteria for Adverse Events, version 4.0. On univariate analysis, lesion volume and diameter, dose to isocenter, and a V{sub x} for doses {>=}8 Gy showed statistical significance. Only lesion diameter showed statistical significance (p < 0.05) in a multivariate model. According to the log-rank test, AVM volumes >5 cm{sup 3} and diameters >30 mm were significantly associated with the risk of radiation injury (p < 0.01). The V{sub 12} also showed strong association with the incidence of radiation injury. Actuarial incidence of radiation injury was 16.8% if V{sub 12} was <28 cm{sup 3} and 53.2% if >28 cm{sup 3} (log-rank test, p = 0.001). Conclusions: This study confirms that the risk of developing symptomatic radiation injury after radiosurgery is related to lesion diameter and volume and irradiated volume. Results suggest a higher tolerance than proposed by QUANTEC. The widely differing findings reported in the literature, however, raise considerable uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of Photon Beams of a Flattening Filter-free Linear Accelerator for Hypofractionated Volumetric Modulated Arc Therapy in Localized Prostate Cancer

Purpose: To evaluate the potential usage of flattening filter-free (FFF) photon beams in the treatment of prostate cancer. Methods and Materials: Volumetric-modulated arc therapy (VMAT) treatment planning was performed for 7 patients using TrueBeam{sup Registered-Sign} linear accelerator and photon beams with (X6, X10) and without (X6FFF, X10FFF) flattening filter. Prescribed dose was 19 Multiplication-Sign 3 Gy = 57 Gy. One or two 360 Degree-Sign arcs with dose rate of 600 MU/min for flattened beams, and 1,200 MU/min for FFF beams were used. Results: No difference was detected between the four beams in PTV coverage, conformity, and homogeneity. Mean body dose and body volume receiving 50% of the prescribed dose decreased with increasing mean energy (r{sup 2} = 0.8275, p < 0.01). X6FFF delivered 3.6% more dose compared with the X6 (p < 0.01). X10FFF delivered 3.0% (p < 0.01), and the X10 5.8% (p < 0.01) less mean body dose compared with X6. There was a significant increase in the mean dose to the rectum for the X10 compared with X6 (2.6%, p < 0.01). Mean dose to the bladder increased by 1.3% for X6FFF and decreased by 2.3% for X10FFF. Using a single arc and FFF, treatment time was reduced by 35% (2 SD = 10%). Conclusion: FFF beams resulted in dose distributions similar to flattened beams. X10FFF beam provided the best solution, sparing rectum and bladder and minimizing whole-body dose. FFF beams lead to a time efficient treatment delivery, particularly when combined with hypofractionated VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Accelerator-Based Radiosurgery Alone for Arteriovenous Malformation: More Than 12 Years of Observation

Purpose: Although radiosurgery is an accepted treatment method for intracranial arteriovenous malformations (AVMs), its long-term therapeutic effects have not been sufficiently evaluated, and many reports of long-term observations are from gamma-knife facilities. Furthermore, there are few reported results of treatment using only linear accelerator (LINAC)-based radiosurgery (LBRS). Methods and Materials: Over a period of more than 12 years, we followed the long-term results of LBRS treatment performed in 51 AVM patients. Results: The actuarial obliteration rates, after a single radiosurgery session, at 3, 5, 10, and 15 years were 46.9%, 54.0%, 64.4%, and 68.0%, respectively; when subsequent radiosurgeries were included, the rates were 46.9%, 61.3%, 74.2%, and 90.3%, respectively. Obliteration rates were significantly related to target volumes ≥4 cm{sup 3}, marginal doses ≥12 Gy, Spetzler-Martin grades (1 vs other), and AVM scores ≥1.5; multivariate analyses revealed a significant difference for target volumes ≥4 cm{sup 3}. The postprocedural actuarial symptomatic radiation injury rates, after a single radiation surgery session, at 5, 10, and 15 years were 12.3%, 16.8%, and 19.1%, respectively. Volumes ≥4 cm{sup 3}, location (lobular or other), AVM scores ≥1.5, and the number of radiosurgery were related to radiation injury incidence; multivariate analyses revealed significant differences associated with volumes ≥4 cm{sup 3} and location (lobular or other). Conclusions: Positive results can be obtained with LBRS when performed with a target volume ≤4 cm{sup 3}, an AVM score ≤1.5, and ≥12 Gy radiation. Bleeding and radiation injuries may appear even 10 years after treatment, necessitating long-term observation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

62 RADIOLOGY AND NUCLEAR MEDICINE↗