Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat engine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

A critical evaluation of various methods for the analysis of flow-solid interaction in a nest of thin cylinders subjected to cross flows

Various experimental, analytical, and numerical analysis methods for flow-solid interaction of a nest of cylinders subjected to cross flows are reviewed. A nest of cylinders subjected to cross flows can be found in numerous engineering applications including the Space Shuttle Maine Engine-Main Injector Assembly (SSME-MIA) and nuclear reactor heat exchangers. Despite its extreme importance in engineering applications, understanding of the flow-solid interaction process is quite limited and design of the tube banks are mostly dependent on experiments and/or experimental correlation equations. For future development of major numerical analysis methods for the flow-solid interaction of a nest of cylinders subjected to cross flow, various turbulence models, nonlinear structural dynamics, and existing laminar flow-solid interaction analysis methods are included.

Kim, Sang-Wook↗

NASA Lewis Stirling engine computer code evaluation

In support of the U.S. Department of Energy's Stirling Engine Highway Vehicle Systems program, the NASA Lewis Stirling engine performance code was evaluated by comparing code predictions without engine-specific calibration factors to GPU-3, P-40, and RE-1000 Stirling engine test data. The error in predicting power output was -11 percent for the P-40 and 12 percent for the Re-1000 at design conditions and 16 percent for the GPU-3 at near-design conditions (2000 rpm engine speed versus 3000 rpm at design). The efficiency and heat input predictions showed better agreement with engine test data than did the power predictions. Concerning all data points, the error in predicting the GPU-3 brake power was significantly larger than for the other engines and was mainly a result of inaccuracy in predicting the pressure phase angle. Analysis into this pressure phase angle prediction error suggested that improvements to the cylinder hysteresis loss model could have a significant effect on overall Stirling engine performance predictions.

Sullivan, Timothy J.↗

An h-adaptive finite element method for turbulent heat transfer

A two-equation turbulence closure model (k-{omega}) using an h-adaptive grid technique and finite element method (FEM) has been developed to simulate low Mach flow and heat transfer. These flows are applicable to many flows in engineering and environmental sciences. Of particular interest in the engineering modeling areas are: combustion, solidification, and heat exchanger design. Flows for indoor air quality modeling and atmospheric pollution transport are typical types of environmental flows modeled with this method. The numerical method is based on a hybrid finite element model using an equal-order projection process. The model includes thermal and species transport, localized mesh refinement (h-adaptive) and Petrov-Galerkin weighting for the stabilizing the advection. This work develops the continuum model of a two-equation turbulence closure method. The fractional step solution method is stated along with the h-adaptive grid method (Carrington and Pepper, 2002). Solutions are presented for 2d flow over a backward-facing step.

54 ENVIRONMENTAL SCIENCES↗

Operations manual: On Site Monitor (OSM), solar heating and cooling systems

The on-site monitor is a portable device which, when connected to a solar system site data acquisition subsystem; allows readouts of clock and sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The unit is described and procedures for its proper operation are presented.

Source record↗

Subsystem design package for the on-site monitor at solar heating and cooling sites

The on-site monitor is a portable device which can be easily connected to a Site Data Acquisition Subsystem to allow readouts of realtime sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The design package consists of the performance specification, performance requirements cross reference, and the acceptance test procedure.

Source record↗

Boiling peak heat flux for steady inhomogeneous heat transfer in superfluid He 4

Superfluid helium-4 (He II) is a widely adopted coolant in scientific and engineering applications owing to its exceptional heat transfer capabilities. However, boiling can spontaneously occur on a heating surface in He II when the heat flux exceeds a threshold value $q^*$, referred to as the peak heat flux. While the parameter $q^*$ holds paramount importance in the design of He II based cooling systems, extensive research has primarily focused on its behavior in steady homogeneous heat transfer from a flat heating surface. For inhomogeneous heat transfer from curved surfaces, $q^*$ exhibits intricate dependance on parameters such as the He II bath temperature $T_b$, the immersion depth $h$, and the curvature radius $R_0$ of the heating surface. A comprehensive understanding on how $q^*$ depends on these parameters remains elusive. In this paper, we report our systematic study on $q^*$ for steady heat transfer from cylindrical and spherical heaters in He II. We compute $q^*$ for a wide range of parameter combinations $(T_b, h, R_0)$ by solving the He II two-fluid equations of motion. The generated data have allowed us to develop a robust correlation that accurately reproduces $q^*$ for all the parameter combinations we explored. Furthermore, our findings, particularly the establishment of the correlation, carry valuable implications for emergent applications that involve steady inhomogeneous heat transfer in He II systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solar Thermal Propulsion

This paper presents viewgraphs on Solar Thermal Propulsion (STP). Some of the topics include: 1) Ways to use Solar Energy for Propulsion; 2) Solar (fusion) Energy; 3) Operation in Orbit; 4) Propulsion Concepts; 5) Critical Equations; 6) Power Efficiency; 7) Major STP Projects; 8) Types of STP Engines; 9) Solar Thermal Propulsion Direct Gain Assembly; 10) Specific Impulse; 11) Thrust; 12) Temperature Distribution; 13) Pressure Loss; 14) Transient Startup; 15) Axial Heat Input; 16) Direct Gain Engine Design; 17) Direct Gain Engine Fabrication; 18) Solar Thermal Propulsion Direct Gain Components; 19) Solar Thermal Test Facility; and 20) Checkout Results.

Gerrish, Harold P., Jr.↗

Application of High Performance Computing for Studying Cyclic Variability in Dilute Internal Combustion Engines

Combustion instabilities in dilute internal combustion engines are manifest in cyclic variability (CV) in engine performance measures such as integrated heat release or shaft work. Understanding the factors leading to CV is important in model-based control, especially with high dilution where experimental studies have demonstrated that deterministic effects can become more prominent. Observation of enough consecutive engine cycles for significant statistical analysis is standard in experimental studies but is largely wanting in numerical simulations because of the computational time required to compute hundreds or thousands of consecutive cycles. We have proposed and begun implementation of an alternative approach to allow rapid simulation of long series of engine dynamics based on a low-dimensional mapping of ensembles of single-cycle simulations which map input parameters to output engine performance. This paper details the use Titan at the Oak Ridge Leadership Computing Facility to investigate CV in a gasoline direct-injected spark-ignited engine with a moderately high rate of dilution achieved through external exhaust gas recirculation. The CONVERGE™ CFD software was used to perform single-cycle simulations with imposed variations of operating parameters and boundary conditions selected according to a sparse grid sampling of the parameter space. Using an uncertainty quantification technique, the sampling scheme is chosen similar to a design of experiments grid but uses algorithms designed to minimize the number of samples required to achieve a desired degree of accuracy. The simulations map input parameters to output metrics of engine performance for a single cycle, and by mapping over a large parameter space, results can be interpolated from within that space. This interpolation scheme forms the basis for a low-dimensional ‘metamodel’ (or model of a model) which can be used to mimic the dynamical behavior of corresponding high-dimensional simulations. Simulations of high-EGR spark-ignition combustion cycles within a parametric sampling grid were performed and analyzed statistically, and sensitivities of the physical factors leading to high CV are presented. With these results, the prospect of producing low-dimensional metamodels to describe engine dynamics at any point in the parameter space will be discussed. Additionally, modifications to the methodology to account for nondeterministic effects in the numerical solution environment are proposed.

Finney, Charles E. A.↗

Additively manufactured heat exchangers: a review on opportunities and challenges

Heat Exchangers (HXs) are crucial engineering components for thermal management. The broad range of applications and the current limits of traditional manufacturing techniques has directed designers and researchers to utilize additive manufacturing (AM) technologies to open a new chapter in HXs design and development. AM has created a world of opportunity to redesign HXs in pioneering forms, shapes, and sizes. In other words, AM technologies provides significant opportunities to increase surface area to volume ratio in heat transfer devices. On the other hand, there are certain challenges to overcome in order to fully grasp the benefits of AM technologies. This thorough review study is different from other published review as it intends to highlight the challenges and opportunities in design and manufacturing of HXs. In addition, part of this study is dedicated to investigate the experimental characterization of additively manufactured HXs. Furthermore, the significant details associated with experimental characterization are normally overlooked in review studies.

42 ENGINEERING↗

Mutual Influence of Capillary Pumps in Heat-Pipe Systems with Different Evaporator Loads

Thermal management systems that are not hermetically sealed have been developed for use in spacecraft; in such systems, scientific equipment and instruments operate in open space. Accordingly, new methods of thermal regulation have been developed: axial and loop heat pipes; and honeycomb thermal panels with embedded axial heat pipes. Heat transfer in heating systems with heat pipes is based on evaporation and condensation in a two-phase loop. The working fluid moves under the action mainly of capillary forces that appear in capillary channels or honeycomb structures for axial heat pipes and in the porous heated medium (capillary pump) of the loop heat pipes.

42 ENGINEERING↗

Analytical Study to Use the Excess Digester Gas of Wastewater Treatment Plants

This study presents an analytical method that can be used to enhance the power production rate and the energy-saving at wastewater treatment plants. The digester used at wastewater treatment plants produces digester gas by anaerobic digestion, with which biofuel production can be achieved. Biofuels can be used to meet some of the energy requirements of the wastewater treatment facility through combined heat and power (CHP) gas engines (cogeneration). Using micro gas turbine (MGT), a CHP technology can be introduced in wastewater treatment plants (WWTPs). The combination of MGTs and absorption chillers is a promising technology as it produces electricity, heating, and cooling simultaneously. The study demonstrated how the waste heat of MGTs could be used to drive absorption chillers. In this analytical study, a detailed technical and economic analysis is provided on the trigeneration system, i.e., the integration of MGTs and absorption chillers driven by waste digester gas of the wastewater treatment plants. It can meet the heating and cooling demands of the plants, which promote the reduction of utility costs. The technology presented is also useful for other thermal energy users.

09 BIOMASS FUELS↗

Low heat transfer oxidizer heat exchanger design and analysis

The RL10-IIB engine, a derivative of the RLIO, is capable of multi-mode thrust operation. This engine operates at two low thrust levels: tank head idle (THI), which is approximately 1 to 2 percent of full thrust, and pumped idle (PI), which is 10 percent of full thrust. Operation at THI provides vehicle propellant settling thrust and efficient engine thermal conditioning; PI operation provides vehicle tank pre-pressurization and maneuver thrust for log-g deployment. Stable combustion of the RL10-IIB engine at THI and PI thrust levels can be accomplished by providing gaseous oxygen at the propellant injector. Using gaseous hydrogen from the thrust chamber jacket as an energy source, a heat exchanger can be used to vaporize liquid oxygen without creating flow instability. This report summarizes the design and analysis of a United Aircraft Products (UAP) low-rate heat transfer heat exchanger concept for the RL10-IIB rocket engine. The design represents a second iteration of the RL10-IIB heat exchanger investigation program. The design and analysis of the first heat exchanger effort is presented in more detail in NASA CR-174857. Testing of the previous design is detailed in NASA CR-179487.

Kanic, P. G.↗

Space shuttle orbit maneuvering engine reusable thrust chamber. Task 13: Subscale helium ingestion and two dimensional heating test report

Descriptions are given of the test hardware, facility, procedures, and results of electrically heated tube, channel and panel tests conducted to determine effects of helium ingestion, two dimensional conduction, and plugged coolant channels on operating limits of convectively cooled chambers typical of space shuttle orbit maneuvering engine designs. Helium ingestion in froth form, was studied in tubular and rectangular single channel test sections. Plugged channel simulation was investigated in a three channel panel. Burn-out limits (transition of film boiling) were studied in both single channel and panel test sections to determine 2-D conduction effects as compared to tubular test results.

Tobin, R. D.↗

guideline36_conformance_test 0.1

The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) has established a set of standardized high performance sequences of operation for Heating, Ventilation and Air Conditioning (HVAC) systems in buildings through their "Guideline 36". In order to achieve the intended performance, these sequences must be translated and programmed accurately in the Building Automation System (BAS) controllers. Standardizing these sequences will allow for a more efficient product delivery mechanism where the sequences are programmed and tested centrally by each manufacturer, and then distributed to their dealers/engineering contractors. This approach would minimize the need for each installer to re-interpret and program the sequences, reduces risk of errors, and reduces the time required for commissioning in the field. To achieve this goal, a performance validation method is needed to provide independent confirmation that each manufacturer has programmed the Guideline 36 sequences accurately. A standardized method of test would also avoid the need for manual interpretation (and the associated human variability) that is required with typical functional testing approaches by automating the inputs and the range of expected responses. This software "guideline36_conformance_test" has been developed to conduct standardized, repeatable and manufacturer independent tests to validate that a BAS controller has been programmed in conformance with Guideline 36. Manufacturers would provide the controller (or the control program) and the software would run a suite of tests by setting a set of inputs to the controller and verifying the output signals from the controller matches the expected output as set by Guideline 36.

Pritoni, Marco↗

Heat-transfer tests of aqueous ethylene glycol solutions in an electrically heated tube

As part of an investigation of the cooling characteristics of liquid-cooled engines, tests were conducted with an electrically heated single-tube heat exchanger to determine the heat-transfer characteristics of an-e-2 ethylene glycol and other ethylene glycol-water mixtures. Similar tests were conducted with water and commercial butanol (n-butyl alcohol) for check purposes. The results of tests conducted at an approximately constant liquid-flow rate of 0.67 pound per second (Reynolds number, 14,500 to 112,500) indicate that at an average liquid temperature 200 degrees f, the heat-transfer coefficients obtained using water, nominal (by volume) 30 percent-70 percent and 70 percent-30 percent glycol-water mixtures are approximately 3.8, 2.8, and 1.4 times higher, respectively, than the heat-transfer coefficients obtained using an-e-2 ethylene glycol.

Bernardo, Everett↗