Green Ocean Amazon 2014/15 High-Volume Filter Sampling: Atmospheric Particulate Matter of an Amazon Tropical City and its Relationship to Population Health Field Campaign Report

Manaus, the capital of the Brazilian state of Amazonas, is developing very rapidly. Its pollution plume contains aerosols from fossil fuel combustion mainly due to vehicular emission, industrial activity, and a thermal power plant. Soil resuspension is probably a secondary source of atmospheric particles. The plume transports from Manaus to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility ARM site at Manacapuru urban pollutants as well as pollutants from pottery factories along the route of the plume. Considering the effects of particulate matter on health, atmospheric particulate matter was evaluated at this site as part of the ARM Facility’s Green Ocean Amazon 2014/15 (GoAmazon 2014/15) field campaign. Aerosol or particulate matter (PM) is typically defined by size, with the smaller particles having more health impact. Total suspended particulate (TSP) are particles smaller than 100 μm; particles smaller than 2.5 μm are called PM2.5. In this work, the PM2.5 levels were obtained from March to December of 2015, totaling 34 samples and TSP levels from October to December of 2015, totaling 17 samples. Sampling was conducted with PM2.5 and TSP high-volume samplers using quartz filters (Figure 1). Filters were stored during 24 hours in a room with temperature (21,1ºC) and humidity (44,3 %) control, in order to do gravimetric analyses by weighing before and after sampling. This procedure followed the recommendations of the Brazilian Association for Technical Standards local norm (NBR 9547:1997). Mass concentrations of particulate matter were obtained from the ratio between the weighted sample and the volume of air collected. Defining a relationship between particulate matter (PM2.5 and TSP) and respiratory diseases of the local population is an important goal of this project, since no information exists on that topic.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Manufacturing Technology Development for Visible Color Filters

Sandia National Laboratories (SNL) and Rockwell Collins Inc. (RCI) developed new metallic filters for separating red, green, and blue channels. These designs were not based on traditional absorptive dye layers. This technology is well-established, but difficult to change from pixel to pixel as pixels shrink in size and increase in number. These films are also quite lossy: throwing away needed light in low-light applications. The SNL-RCI technology investigated metal plasmonic filters. These patterns are a single thin layer and the metal pattern may be changed from one pixel to the next simply by varying the metal pattern shape or dimensions. This allows adjacent pixels to view different colors with an efficient processing method and without loss of as much loss as the dye technology.

36 MATERIALS SCIENCE↗

Nanomaterial-Treated Filters for the Uptake of Heavy Metals from Water Sources

We describe the synthesis and properties of ligand-modified gold nanoparticles (AuNPs) grown on stainless steel wool filters. Their selectivity and efficiency with regards to heavy metal uptake from groundwater and other sources of drinking water found at or near DOE facilities were also tested. The nanomaterial-treated filters are advantageous because they serve as inactive supports that allow for efficient flow of the contaminated water and can be easily replaced after heavy metal uptake. They are also comparable to nanomaterials free in solution with regards to the effectiveness of remediation of drinking water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

222-S Pre-Filter: Radiological Evaluation of Worker Potential Internal Dose

This report provides a radiological evaluation of the potential internal dose for workers located near 222-S Laboratory during the Plutonium Finishing Plant release event in December 2017 and for workers handling the 222-S Laboratory air handling unit intake pre-filters following this event. The maximum potential internal dose to workers was determined to be below 1 mrem committed effective dose. This was based on an evaluation of the near-field air monitoring station and the laboratory analysis of a sample taken from an air handling unit intake pre-filter.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and Characterization of Cementitious Waste Forms for Immobilization of Granular Activated Carbon, Silver Mordenite, and HEPA Filter Media Solid Secondary Waste

Solid secondary waste materials expected to be generated during Hanford Waste Treatment and Immobilization Plant (WTP) operations were characterized (using representative materials) with respect to their ability to retain technetium-99 (Tc), iodine-129 (I), and mercury (Hg) as input to future updates to the Integrated Disposal Facility (IDF) performance assessments (PAs). The waste materials included granular activated carbon (GAC), silver mordenite (AgM), and high-efficiency particulate air (HEPA) filter media; all are used for removal of contaminants and radionuclides from the gaseous effluent treatment systems within the WTP. It is expected that the GAC and AgM will be mixed into a cementitious waste form in which the GAC and AgM particles will be blended/stabilized into the cementitious material. It is also expected that the HEPA filter media will be compacted and placed in a container that is then backfilled with a grout to macroencapsulate the medium. Here we report Kds for all waste materials of interest, examine the physical properties of grout specimens containing the waste materials, and provide solid-state characterization information to further understand the interaction of the waste materials with the encapsulating grout. The Kds are used in PA calculations that estimate contaminant release from the disposal site. Monolithic test specimens were prepared with the GAC and AgM mixed in either a Cast Stone grout formulation (8 weight percent [wt%] ordinary Portland cement [OPC], 45 wt% fly ash [FA], 47 wt% blast furnace slag [BFS]) or a Hanford grout mix 5 (HGM-5) formulation (25 wt% OPC, 75 wt% FA). As the specimens were being prepared, the fluid grout mixes were characterized for processing properties including flowability, set time, and the presence of free liquids during curing. After curing, compressive strengths of the waste forms were measured; the compressive strengths were above 2000 psi, easily exceeding the 500 psi minimum requirement. The cured waste forms were also characterized for their density, porosity, hydraulic conductivity, and water characteristic curve—all properties needed in PA calculations of radionuclide release from the waste forms in the IDF. Finally, EPA Method 1315 leach tests were conducted on the GAC and AgM waste materials encapsulated in the Cast Stone and HGM-5 grouts to determine the rate of release of contaminants from the waste forms. Effective diffusivities are provided, which can be used in future PA analyses of the disposal of these solid secondary waste materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-Resolved Aerosol Filter Sampler Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook describes the principles and operations of the filter sampler.

54 ENVIRONMENTAL SCIENCES↗

Low Energy Photon Filter Box Optimization Study for the Gamma Irradiation Facility (GIF)

As a follow-up to results presented at the 16th International Symposium on Reactor Dosimetry, a new set of low energy photon filter box designs were evaluated for potential testing at the Gamma Irradiation Facility in Sandia National Laboratories' Technical Area V. The goal of this filter box design study is to produce the highest fidelity gamma ray test environment for electronic parts. Using Monte Carlo coupled photon/electron transport, approximately a dozen different designs were evaluated for the effectiveness in reducing the dose enhancement in a silicon sensor. The completion of this study provides the Radiation Metrology Laboratory staff with a starting point for experimental test plans that could lead to improvement in the gamma ray test environment at the Gamma Irradiation Facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

GraphAlign: Graph-Enabled Machine Learning for Seismic Event Filtering

This report summarizes results from a 2 year effort to improve the current automated seismic event processing system by leveraging machine learning models that can operated over the inherent graph data structure of a seismic sensor network. Specifically, the GraphAlign project seeks to utilize prior information on which stations are more likely to detect signals originating from particular geographic regions to inform event filtering. To date, the GraphAlign team has developed a Graphical Neural Network (GNN) model to filter out false events generated by the Global Associator (GA) algorithm. The algorithm operates directly on waveform data that has been associated to an event by building a variable sized graph of station waveforms nodes with edge relations to an event location node. This builds off of previous work where random forest models were used to do the same task using hand crafted features. The GNN model performance was analyzed using an 8 week IMS/IDC dataset, and it was demonstrated that the GNN outperforms the random forest baseline. We provide additional error analysis of which events the GNN model performs well and poorly against concluded by future directions for improvements.

58 GEOSCIENCES↗

Parametric Analysis of Holdup in HEPA Filters

This technical document (TECH) contains an analysis of several conditions deemed credible for plutonium oxide buildup in high-efficiency air particulate (HEPA) filters to determine the effect of holdup inside the filter on reactivity. This document is performed in accordance with NCS-AP-005, R3 [Ref. (1)].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A detection of the integrated sachs-wolfe imprint of cosmic superstructures using a matched-filter approach

We present a new method for detection of the integrated Sachs–Wolfe (ISW) imprints of cosmic superstructures on the cosmic microwave background (CMB), based on a matched-filtering approach. The expected signal-to-noise ratio for this method is comparable to that obtained from the full cross-correlation, and unlike other stacked filtering techniques it is not subject to an a posteriori bias. We apply this method to Planck CMB data using voids and superclusters identified in the CMASS galaxy data from the Sloan Digital Sky Survey Data Release 12, and measure the ISW amplitude to be A{sub ISW}=1.64±0.53 relative to the ΛCDM expectation, corresponding to a 3.1σ detection. In contrast to some previous measurements of the ISW effect of superstructures, our result is in agreement with the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Miniature lowpass filters in low loss 9k7 LTCC

DuPont 9k7 low temperature cofired ceramic (LTCC) is a low loss, or high quality factor Q, tape system targeting at radio frequency (RF) applications. This paper reports the effect of a critical process parameter, heating rate, on the densification and dielectric properties of the 9k7 LTCC. The role of competing densification and crystallization during the sintering of 9k7 is discussed. The high Q of DuPont 9K7 can be used to improve RF system performance, for example a better receiver noise figure, by designing embedded passive RF components such as inductors, capacitors and filters. As a result, miniaturized multilayer low pass filters (LPF) with a wide stopband were fabricated to showcase the technology.

36 MATERIALS SCIENCE↗

Broadband and filter radiometers at Ross Island, Antarctica: detection of cloud ice phase versus liquid water influences on shortwave and longwave radiation

Abstract. Surface radiometer data from Ross Island, Antarctica, collected during the austral summer 2015–2016 by the US Department of Energy Atmospheric Radiation Measurement (ARM) program West Antarctic Radiation Experiment (AWARE), are used to evaluate how shortwave and longwave irradiance respond to changing cloud properties as governed by contrasting meteorological regimes. Shortwave atmospheric transmittance is derived from pyranometer measurements, and cloud conservative-scattering optical depth is derived from filter radiometer measurements at 870 nm. With onshore flow associated with marine air masses, clouds contain mostly liquid water. With southerly flow over the Transantarctic Mountains, orographic forcing induces substantial cloud ice water content. These ice and mixed-phase clouds attenuate more surface shortwave irradiance than the maritime-influenced clouds and also emit less longwave irradiance due to colder cloud base temperature. These detected irradiance changes are in a range that can mean onset or inhibition of surface melt over ice shelves. This study demonstrates how basic and relatively low-cost broadband and filter radiometers can be used to detect subtle climatological influences of contrasting cloud microphysical properties at very remote locations.

54 ENVIRONMENTAL SCIENCES↗

Application of Statistical Filter Theory to the Optimal Estimation of Position and Velocity on Board a Circumlunar Vehicle

Concepts from statistical filter theory are applied to the problem of in-flight determination of the position and velocity of a space vehicle for the purposes of midcourse guidance. The source of information is assumed to be an arbitrary sequence of measurements of any desired set of "observables" (e.g., space angles), the measurements being corrupted by additive errors so that the position and velocity are never known perfectly. A state transition approach is employed which leads naturally to a computational scheme that is readily implemented by a digital computer. The scheme can be regarded as a dynamical time-varying filter which weights the incoming observations in an optimal sense for use in producing an up-to-date optimal estimate of position and velocity. The advantages of the scheme are (1) it provides the best possible estimate (minimum error) based upon ensemble statistics of injection conditions and measurement errors; (2) it is extremely versatile, not requiring adherence to a predetermined observation schedule or reference trajectory; and (3) the computations are sufficiently simple to be practical in an on-board computer. A digital computer simulation of the proposed system is employed to demonstrate the feasibility of an all on-board system and to illustrate the performance attainable in a hypothetical physical situation.

SPACE VEHICLE↗

Filter for high-pressure gases has easy take- down, assembly

A small metal filter body, for use in tubing supplying sterilization gases, has an inlet end that can be unscrewed. Inside, the high pressure filter is supported on both sides and sealed by an O ring. Design facilitates assembly and disassembly of parts.

Mac Glashan, W. F.↗

High-pass RF coaxial filter rejects dc and low frequency signals

A low-loss RF filter element for coaxial transmission provides dc isolation and eliminates low frequency signals. The characteristic impedance of the transmission line is not affected, as the design permits direct connection of the filter to the line.

Bailey, J. W.↗

PTFE-ALUMINUM films serve as neutral density filters

Polytetrafluoroethylene /PTFE/ films coated with aluminum films act as neutral density filters in the wavelength range 0.3 to 2.1 microns. These filters are effective in the calibration of photometric systems.

Burks, H. D.↗