Application of the Hartmann–Tran profile to precise experimental data sets of 12 C 2 H 2

Self- and nitrogen-broadened line shape data for the P e (11) line of the ν₁ + ν₃ band of acetylene, recorded using a frequency comb-stabilized laser spectrometer, have been analyzed using the Hartmann–Tran profile (HTP) line shape model in a multispectrum fitting. In total, the data included measurements recorded at temperatures between 125 K and 296 K and at pressures between 4 and 760 Torr. New, sub-Doppler, frequency comb-referenced measurements of the positions of multiple underlying hot band lines have also been made. These underlying lines significantly affect the P e (11) line profile at temperatures above 240 K and poorly known frequencies previously introduced errors into the line shape analyses. Thus, the behavior of the HTP model was compared to the quadratic speed dependent Voigt profile (QSDVP) expressed in the frequency and time domains. A parameter uncertainty analysis was carried out using a Monte Carlo method based on the estimated pressure, transmittance and frequency measurement errors. From the analyses, the P e (11) line strength was estimated to be 1.2014(50) × 10 -20 in cm.molecules⁻¹ units at 296 K with the standard deviation in parenthesis. For analyzing these data, we found that a reduced form of the HTP, equivalent to the QSDVP, was most appropriate because the additional parameters included in the full HTP were not well determined. As a supplement to this work, expressions for analytic derivatives and a lineshape fitting code written in Matlab for the HTP are available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global optimization of data quality checks on 2-D and 3-D networks of GPR cross-well tomographic data for automatic correction of unknown well deviations

Significant errors related to poor time zero estimation, well deviation or mislocation of the transmitter (TX) and receiver (RX) stations can render even the most sophisticated modeling and inversion routine useless. Previous examples of methods for the analysis and correction of data errors in geophysical tomography include the works of Maurer and Green (1997), Squires et al. (1992) and Peterson (2001). Here we follow the analysis and techniques of Peterson (2001) for data quality control and error correction. Through our data acquisition and quality control procedures we have very accurate control on the surface locations of wells, the travel distance of both the transmitter and receiver within the boreholes, and the change in apparent zero time. However, we often have poor control on well deviations, either because of economic constraints or the nature of the borehole itself prevented the acquisition of well deviation logs. Also, well deviation logs can sometimes have significant errors. Problems with borehole deviations can be diagnosed prior to inversion of travel-time tomography data sets by plotting the apparent velocity of a straight ray connecting a transmitter (TX) to a receiver (RX) against the take-off angle of the ray. Issues with the time-zero pick or distances between wells appear as symmetric smiles or frown in these QC plots. Well deviation or dipping-strong anisotropy will result in an asymmetric correlation between apparent velocity and take-off angle (Figure 1-B). In addition, when a network of interconnected GPR tomography data is available, one has the additional quality constraint of insuring that there is continuity in velocity between immediately adjacent tomograms. A sudden shift in the mean velocity indicates that either position deviations are present or there is a shift in the pick times. Small errors in well geometry may be effectively treated during inversion by including weighting, or relaxation, parameters into the inversion (e.g. Bautu et al., 2006). In the technique of algebraic reconstruction tomography (ART), which is used herein for the travel time inversion (Peterson et al., 1985), a small relaxation parameter will smooth imaging artifacts caused by data errors at the expense of resolution and contrast (Figure 2). However, large data errors such as unaccounted well deviations cannot be adequately suppressed through inversion weighting schemes. Previously, problems with tomograms were treated manually. However, in large data sets and/or networks of data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Mislocation of the transmitter and receiver stations of GPR cross-well tomography data sets can lead to serious imaging artifacts if not accounted for prior to inversion. Previously, problems with tomograms have been treated manually prior to inversion. In large data sets and/or networks of tomographic data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Our approach is to use cross-well data quality checks and a simplified model of borehole deviation with particle swarm optimization (PSO) to automatically correct for source and receiver locations prior to tomographic inversion. We present a simple model of well deviation, which is designed to minimize potential corruption of actual data trends. We also provide quantitative quality control measures based on minimizing correlations between take-off angle and apparent velocity, and a quality check on the continuity of velocity between adjacent wells. This methodology is shown to be accurate and robust for simple 2-D synthetic test cases. Plus, we demonstrate the method on actual field data where it is compared to deviation logs. This study shows the promise for automatic correction of well deviations in GPR tomographic data. Analysis of synthetic data shows that very precise estimates of well deviation can be made for small deviations, even in the presence of static data errors. However, the analysis of the synthetic data and the application of the method to a large network of field data show that the technique is sensitive to data errors varying between neighboring tomograms.

54 ENVIRONMENTAL SCIENCES↗

Spurious Shear in Weak Lensing with LSST

The complete 10-year survey from the Large Synoptic Survey Telescope (LSST) will image {approx} 20,000 square degrees of sky in six filter bands every few nights, bringing the final survey depth to r {approx} 27.5, with over 4 billion well measured galaxies. To take full advantage of this unprecedented statistical power, the systematic errors associated with weak lensing measurements need to be controlled to a level similar to the statistical errors. This work is the first attempt to quantitatively estimate the absolute level and statistical properties of the systematic errors on weak lensing shear measurements due to the most important physical effects in the LSST system via high fidelity ray-tracing simulations. We identify and isolate the different sources of algorithm-independent, additive systematic errors on shear measurements for LSST and predict their impact on the final cosmic shear measurements using conventional weak lensing analysis techniques. We find that the main source of the errors comes from an inability to adequately characterise the atmospheric point spread function (PSF) due to its high frequency spatial variation on angular scales smaller than {approx} 10{prime} in the single short exposures, which propagates into a spurious shear correlation function at the 10{sup -4}-10{sup -3} level on these scales. With the large multi-epoch dataset that will be acquired by LSST, the stochastic errors average out, bringing the final spurious shear correlation function to a level very close to the statistical errors. Our results imply that the cosmological constraints from LSST will not be severely limited by these algorithm-independent, additive systematic effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prognostics Health Management Model for LED Package Failure Under Contaminated Environment

The reliability consideration of LED products includes both luminous flux drop and color shift. Previous research either talks about luminous maintenance or color shift, because luminous flux degradation usually takes very long time to observe. In this paper, the impact of a VOC (volatile organic compound) contaminated luminous flux and color stability are examined. As a result, both luminous degradation and color shift had been recorded in a short time. Test samples are white, phosphor-converted, high-power LED packages. Absolute radiant flux is measured with integrating sphere system to calculate the luminous flux. Luminous flux degradation and color shift distance were plotted versus aging time to show the degradation pattern. A prognostic health management (PHM) method based on the state variables and state estimator have been proposed in this paper. In this PHM framework, unscented kalman filter (UKF) was deployed as the carrier of all states. During the estimation process, third order dynamic transfer function was used to implement the PHM framework. Both of the luminous flux and color shift distance have been used as the state variable with the same PHM framework to exam the robustness of the method. Predicted remaining useful life is calculated at every measurement point to compare with the tested remaining useful life. The result shows that state estimator can be used as the method for the PHM of LED degradation with respect to both luminous flux and color shift distance. The prediction of remaining useful life of LED package, made by the states estimator and data driven approach, falls in the acceptable error-bounds (20%) after a short training of the estimator.

Lall, Pradeep↗

Robust verification of stochastic simulation codes

We introduce a robust verification tool for computational codes, which we call Stochastic Robust Extrapolation based Error Quantification (StREEQ). Unlike the prevalent Grid Convergence Index (GCI) [1] method, our approach is suitable for both stochastic and deterministic computational codes and is generalizable to any number of discretization variables. Building on ideas introduced in the Robust Verification [2] approach, we estimate the converged solution and orders of convergence with uncertainty using multiple fits of a discretization error model. In contrast to Robust Verification, we perform these fits to many bootstrap samples yielding a larger set of predictions with smoother statistics. Here, bootstrap resampling is performed on the lack-of-fit errors for deterministic code responses, and directly on the noisy data set for stochastic responses. This approach lends a degree of robustness to the overall results, capable of yielding precise verification results for sufficiently resolved data sets, and appropriately expanding the uncertainty when the data set does not support a precise result. For stochastic responses, a credibility assessment is also performed to give the analyst an indication of the trustworthiness of the results. Furthermore, this approach is suitable for both code and solution verification, and is particularly useful for solution verification of high-consequence simulations..

97 MATHEMATICS AND COMPUTING↗

An AFM Dynamic Contact Model with Finite Thickness Correction to Study Micro-Rheology of Biological Cells

One of the major sources of error in Atomic Force Microscopy based Force Spectroscopic studies is bottom substrate effect, which comes due to assumption of infinite sample thickness. In the present work, anew experimentally validated mathematical correction for finite thickness of thesample is incorporated into a dynamic indentation model. This model is an extension of Sneddon’s static indentation contact model developed for conical tip indenters by incorporating the tip geometric effects, correction to hydrodynamic drag, viscoelastic nature of the sample and its finite thickness. The new model is applied to extract the viscoelastic properties of primary mesenchymal stem cells (MSC’s) extracted from human bone marrow and HCT-116 aggressive epithelial colorectal cancer cells. The micro-rheological studies indicated the presence of profound influence of infinite thickness assumption depending upon indentation depth and sample thickness at the point of indentation. The present model nullified this error and provided a better estimate of the rheological properties. The tests were conducted over a wide frequency bandwidth (0.5 to 126 Hz) and frequency dependent material properties were analyzed using power law structural damping model. It was found that MSC’s are stiffer and less viscous in nature compared to cancer cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also necessary to have the accurate spectrum information about the source-detector system. When dealing with experimental data, the spectrum can be predicted by a Monte Carlo simulator. For the materials between water and bone, less than 5% separation errors are observed on the estimated decomposition fractions.Conclusions: The proposed approach is a statistical reconstruction approach based on a nonlinear forward model counting the full beam polychromaticity and applied directly to the projections without taking negative-log. Compared to the approaches based on linear forward models and the BHA correction approaches, it has advantages in noise robustness and reconstruction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using the electron localization function to correct for confinement physics in semi-local density functional theory

We have previously proposed that further improved functionals for density functional theory can be constructed based on the Armiento-Mattsson subsystem functional scheme if, in addition to the uniform electron gas and surface models used in the Armiento-Mattsson 2005 functional, a model for the strongly confined electron gas is also added. However, of central importance for this scheme is an index that identifies regions in space where the correction provided by the confined electron gas should be applied. The electron localization function (ELF) is a well-known indicator of strongly localized electrons. We use a model of a confined electron gas based on the harmonic oscillator to show that regions with high ELF directly coincide with regions where common exchange energy functionals have large errors. This suggests that the harmonic oscillator model together with an index based on the ELF provides the crucial ingredients for future improved semi-local functionals. For a practical illustration of how the proposed scheme is intended to work for a physical system we discuss monoclinic cupric oxide, CuO. A thorough discussion of this system leads us to promote the cell geometry of CuO as a useful benchmark for future semi-local functionals. Very high ELF values are found in a shell around the O ions, and take its maximum value along the Cu–O directions. An estimate of the exchange functional error from the effect of electron confinement in these regions suggests a magnitude and sign that could account for the error in cell geometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Online quantitative analysis of multispectral images of human body tissues

A method is developed for online monitoring of structural and morphological parameters of biological tissues (haemoglobin concentration, degree of blood oxygenation, average diameter of capillaries and the parameter characterising the average size of tissue scatterers), which involves multispectral tissue imaging, image normalisation to one of its spectral layers and determination of unknown parameters based on their stable regression relation with the spectral characteristics of the normalised image. Regression is obtained by simulating numerically the diffuse reflectance spectrum of the tissue by the Monte Carlo method at a wide variation of model parameters. The correctness of the model calculations is confirmed by the good agreement with the experimental data. The error of the method is estimated under conditions of general variability of structural and morphological parameters of the tissue. The method developed is compared with the traditional methods of interpretation of multispectral images of biological tissues, based on the solution of the inverse problem for each pixel of the image in the approximation of different analytical models. (biomedical optics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diamagnetic loop measurement in Korea Superconducting Tokamak Advanced Research machine

Diamagnetic loop (DL), which consists of two poloidal loops inside the vacuum vessel, is used to measure the diamagnetic flux during a plasma discharge in the Korea Superconducting Tokamak Advanced Research (KSTAR) machine. The vacuum fluxes in the DL signal can be compensated up to 0.1 mWb by using the coefficients, which are obtained from experimental investigations, in the vacuum flux measurements during vacuum shots under same operational conditions of magnetic coils for plasma experiment in the KSTAR machine. The maximum error in the diamagnetic flux measurement due to the errors of the coefficients was estimated as {approx}0.22 mWb. From the diamagnetic flux measurements for the ohmically heated circular plasmas in the KSTAR machine, the stored energy agrees well with the estimated kinetic energy within the discrepancy of 25%. When the electron cyclotron heating, the neutral beam injection, and the ion cyclotron resonance heating are added to the ohmically heated limiter plasmas, the additional heating effects can be clearly observed from the increase of the stored energy evaluated in the DL measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transfer learning for analysis of collective and non-collective Thomson scattering spectra

Thomson scattering (TS) diagnostics provide reliable, minimally perturbative measurements of fundamental plasma parameters, such as electron density (⁠n e ) and electron temperature (⁠T e ⁠). Deep neural networks can provide accurate estimates of ⁠n e and T e when conventional fitting algorithms may fail, such as when TS spectra are dominated by noise, or when fast analysis is required for real-time operation. Although deep neural networks typically require large training sets, transfer learning can improve model performance on a target task with limited data by leveraging pre-trained models from related source tasks, where select hidden layers are further trained using target data. We present five architecturally diverse deep neural networks, pre-trained on synthetic TS data and adapted for experimentally measured TS data, to evaluate the efficacy of transfer learning in estimating n e and T e in both the collective and non-collective scattering regimes. We evaluate errors in n e and T e estimates as a function of training set size for models trained with and without transfer learning, and we observe decreases in model error from transfer learning when the training set contains ≲ 200 experimentally measured spectra.

Artificial neural networks↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

Design of error-compensating algorithms for sinusoidal phase shifting interferometry

An improved approach to interferometry using sinusoidal phase shifting balances several harmonic components in the interference signal against each other. The resulting computationally efficient phase-estimation algorithms have low sensitivity to errors such as spurious intensity noise, vibration, and errors in the phase shift pattern. Specific example algorithms employing 8 and 12 camera frames illustrate design principles that are extendable to algorithms of any length for applications that would benefit from a simplified, sinusoidal phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Assessment of Global Positioning System Velocity Uncertainty in California

We analyze data from 580 continuous global positioning system (GPS) stations in California to quantify differences in published velocity estimates from five analysis centers. Horizontal and vertical rates for individual stations can differ up to 5 mm/yr, with systematic differences in some areas comparable to deformation rates. Published velocity uncertainties vary between analysis centers and are systematically underreported in the horizontal relative to empirical uncertainties calculated from the scatter of analysis center velocities. In the vertical, published velocity uncertainties are both over and underreported and vary more widely between centers. An interpolated ensemble vertical velocity field shows high-subsidence regions in the Central Valley and Salton Trough have the largest empirical uncertainties, while station density has a modest impact on uncertainties. Applications that rely on subcentimeter GPS accuracy should consider the possibility that formal errors published with velocity rate estimates understate true velocity uncertainties in both the horizontal and vertical.

54 ENVIRONMENTAL SCIENCES↗

Trip Energy Estimation Methodology and Model Based on Real-World Driving Data for Green Routing Applications: Preprint

A data-informed model to predict energy use for a proposed vehicle trip has been developed in this paper. The methodology leverages nearly 1 million miles of real-world driving data to generate the estimation model. Driving is categorized at the sub-trip level by average speed, road gradient, and road network geometry, then aggregated by category. An average energy consumption rate is determined for each category, creating an energy rates look-up table. Proposed vehicle trips are then categorized in the same manner, and estimated energy rates are appended from the look-up table. The methodology is robust and applicable to almost any type of driving data. The model has been trained on vehicle global positioning system data from the Transportation Secure Data Center at the National Renewable Energy Laboratory and validated against on-road fuel consumption data from testing in Phoenix, Arizona. The estimation model has demonstrated an error range of 8.6% to 13.8%. The model results can be used to inform control strategies in routing tools, such as change in departure time, alternate routing, and alternate destinations to reduce energy consumption. This work provides a highly extensible framework that allows the model to be tuned to a specific driver or vehicle type.

25 ENERGY STORAGE↗

A maximum likelihood approach to estimating correlation functions

We define a maximum likelihood (ML for short) estimator for the correlation function, ξ, that uses the same pair counting observables (D, R, DD, DR, RR) as the standard Landy and Szalay (LS for short) estimator. The ML estimator outperforms the LS estimator in that it results in smaller measurement errors at any fixed random point density. Put another way, the ML estimator can reach the same precision as the LS estimator with a significantly smaller random point catalog. Moreover, these gains are achieved without significantly increasing the computational requirements for estimating ξ. We quantify the relative improvement of the ML estimator over the LS estimator and discuss the regimes under which these improvements are most significant. We present a short guide on how to implement the ML estimator and emphasize that the code alterations required to switch from an LS to an ML estimator are minimal.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-D-210-05: The Accuracy of Raw and B-Mode Image Data for Ultrasound Speckle Tracking in Radiation Therapy

Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation template matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion would also be prudent. This work is support by Cancer Research UK Programme Grant C33589/A19727.