Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficient buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What, why and when to go virtual: An international analysis of early adopters of virtual building energy codes inspections

To meet greenhouse gas reduction targets, several countries are pursuing more ambitious policies in their buildings and construction sectors, such as introducing zero net energy/carbon building codes. Countries often report not having enough qualified staff for performing building energy code inspections and many are exploring faster, easier, and more reliable methods to check the compliance of buildings with their codes. Building inspections are a critical element for ensuring code compliance and they have traditionally been performed in person. However, in-person inspections can be labor and travel intensive, costly, and prone to human error. In this paper, the authors explore how virtual inspections, particularly in light of the recent COVID-19 pandemic, have impacted processes for building code compliance checks in jurisdictions and communities around the world. Here, the authors collected data on four key parameters (time and financial savings, scope of inspections, changing practices and technological innovation, and benefits to consumers) from six jurisdictions and communities in five countries (Australia, Canada, Singapore, United Arab Emirates, and the United States) to analyze the impacts of virtual inspections on code compliance checks. The analysis found the greatest value from virtual inspections in geographically dispersed regions and for cities experiencing rapid building construction. The study also explored emerging technologies that are being piloted for virtual inspections. Although many of these technologies hold promise, more resources and capacity are needed to make them viable for use in building energy code inspections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On the importance of the heat and mass transfer resistances in internally-cooled liquid desiccant dehumidifiers and regenerators

Liquid desiccant heat and mass exchangers are a promising technology for efficient humidity control in buildings. Many researchers have investigated these exchangers, often using numerical models to predict their performance. However, there is a lack of information in the literature on the magnitude of the heat and mass transfer resistances, both for the dehumidifier (which absorbs moisture from the air) and the regenerator (which heats the liquid desiccant to re-concentrate it). This article focuses on internally-cooled, 3-fluid exchangers in a parallel plate geometry. Water heats or cools a desiccant across a plate, and the desiccant absorbs or releases water into an airstream through a membrane. A sensitivity analysis was used to estimate the importance of each of the heat and mass transfer resistances (air, membrane, desiccant, plate, water), and how it changes with different design geometries. The results show that, for most designs, the latent and sensible heat transfer of the dehumidifier is dominated by the air mass transfer resistance and air heat transfer resistance, respectively. The air mass transfer resistance is also important for the regenerator, but much less so; the change in the desiccant equilibrium humidity ratio due to a change in either temperature or desiccant mass fraction is much higher at the regenerator's higher temperatures. This increases the importance of (1) getting heat from the water to the desiccant/membrane interface, and (2) diffusing salt ions quickly away from the desiccant/membrane interface. The membrane heat transfer and water heat transfer resistances were found to be the least important. These results can help inform decisions about what simplifying assumptions to make in numerical models, and can also help in designing these exchangers by understanding which resistances are most important.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Urban flood modeling using shallow water equations with depth-dependent anisotropic porosity

The shallow water model with anisotropic porosity conceptually takes into account the unresolved subgrid-scale features, e.g. microtopography or buildings. This enables computationally efficient simulations that can be run on coarser grids, whereas reasonable accuracy is maintained via the introduction of porosity. This article presents a novel numerical model for the depth-averaged equations with anisotropic porosity. The porosity is calculated using the probability mass function of the subgrid-scale features in each cell and updated in each time step. The model is tested in a one-dimensional theoretical benchmark before being evaluated against measurements and high-resolution predictions in three case studies: a dam-break over a triangular bottom sill, a dam-break through an idealized city and a rainfall-runoff event in an idealized urban catchment. The physical processes could be approximated relatively well with the anisotropic porosity shallow water model. The computational resolution influences the porosities calculated at the cell edges and therefore has a large influence on the quality of the solution. The computational time decreased significantly, on average three orders of magnitude, in comparison to the classical high-resolution shallow water model simulation.

finite volume method↗

Spatially Patterned Architectures to Modulate CO 2 Reduction Cascade Catalysis Kinetics

Electrochemical CO 2 reduction using renewable sources of electrical energy holds promise for converting CO 2 into fuels and chemicals. The complex interactions among chemical/electrochemical reactions and mass transport make it difficult to analyze the effect of an individual process on electrode performance based only on experimental methods. Here, we developed a generalized steady-state simulation to describe an electrode surface in which sequential cascade catalysts are patterned in a periodic trench design. If appropriately constructed, this trench geometry is hypothesized to be able to yield a higher net current density for a CO 2 reduction (CO 2 R) cascade reaction. We have used realistic experimental reaction kinetics to investigate the role of trench geometry in mass transport, local microenvironments, and selectivity for a model CO 2 R cascade reaction. The model considers local concentration gradients of bicarbonate species at quasi-equilibrium and catalytic surface reactions based on concentration-dependent Butler–Volmer kinetics. Our results suggest that varying the spatial distribution of active sites plays a significant role in facilitating effective mass transport between active sites, modulating selectivity for the cascade reaction, and enhancing the yield of desirable cascade products. Moreover, we observe that this trench geometry significantly alters the cascade reaction rate by affecting the local pH, which can cause inadvertent depletion of available aqueous CO 2 to limit the CO 2 R cascade kinetics and modest suppression of the hydrogen evolution reaction (HER). The results highlight the trade-offs between mass transport, pH, and reaction kinetics that become apparent only when considering the coupled physics of all processes at the electrode surface. Here, this model can thus serve as a primary tool to build more selective and efficient patterned architectures for the CO 2 R cascade catalysis.

CO2 reduction↗

A labeled dataset for building HVAC systems operating in faulted and fault-free states

Abstract Open data is fueling innovation across many fields. In the domain of building science, datasets that can be used to inform the development of operational applications - for example new control algorithms and performance analysis methods - are extremely difficult to come by. This article summarizes the development and content of the largest known public dataset of building system operations in faulted and fault free states. It covers the most common HVAC systems and configurations in commercial buildings, across a range of climates, fault types, and fault severities. The time series points that are contained in the dataset include measurements that are commonly encountered in existing buildings as well as some that are less typical. Simulation tools, experimental test facilities, and in-situ field operation were used to generate the data. To inform more data-hungry algorithms, most of the simulated data cover a year of operation for each fault-severity combination. The data set is a significant expansion of that first published by the lead authors in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Passive Cooling Potential of Thermal Mass Inherent in Medium to Large Commercial Buildings

Typical commercial construction inherently contains large surface areas of relatively thin mass located in the floor slabs. This research asks how effective this mass could be for passive cooling, relative to other mass depths, if it were to be exposed and used as thermal mass. Although much of the rich literature on thermal mass has been conducted with far greater mass depths, a more limited amount of research suggests that because the surface heat transfer rate is limited, the focus should be on the surface area of exposed mass, not its depth. This presents an opportunity for more buildings to behave more thermally massively, if the mass inherent in typical floor slabs contains utility, particularly over diurnal cycles. In all climates analyzed, it was found that there is a pronounced shoulder where energy savings from passive cooling of increasing mass depths was steep until roughly 7.5–10 cm, and beyond this point the achieved energy savings diminished rapidly. When considering the embodied energy of concrete, the incremental benefit of added mass beyond a typical topping slab of 10 cm does not justify the incremental embodied energy cost from a total energy standpoint alone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Discrete Hankel Transform Approach to Nuclear Data Processing for Fusion Applications

This study introduces advancements to the numerical solutions employed in the processing of nuclear data for fusion applications. It leverages the convolution theorem and Fourier transform techniques to enhance computational efficiency and broaden applicability. Building upon a previously reported discrete Hankel transform approach for Doppler broadening, this work refines the solution of convolution integrals central to these applications. The methodology provides a general and unified framework for evaluating any convolution operation, regardless of whether the underlying problem involves temperature effects in nuclear reactions. The applicability to the nuclear data processing for fusion is demonstrated by deriving the convolution integrals for some of the fusion-related quantities. As before, the convolution operation utilizes a Gaussian-based kernel; however, the discrete Hankel transform of order $𝛼$ = $\frac{1}{2}$ is now applied to the forward Fourier transform of the nonkernel argument, rather than the inverse Fourier transform. This modification eliminates the need for the integration of the nonkernel, cross section–based function, which is a step that posed challenges for certain pointwise cross-section representations. It also removes the requirement for cross-section linearization. Optimized for graphics processing unit architectures, the approach significantly improves computational performance. These advancements are currently under evaluation as the foundation for the next-generation thermonuclear data file processing codes being developed at Lawrence Livermore National Laboratory.

Nuclear science and engineering↗

A Low Voltage DC Power Electronic Hub to Support Buildings

This paper presents the communication, control, and architecture, for a low voltage (nominal 480V) hybrid AC/DC microgrid for supporting small commercial buildings with critical data center loads. The proposed system is based on a dc-power electronic hub (PEH) that seamlessly integrates renewable energy resources, energy storage, and back-up generation to support commercial building economical energy management and reliability. This PEH concept provides a parallelization of critical power to the commercial and industrial buildings leading to increased efficiency and reliability compared to traditional uninterruptable power supplies. The demonstration of the proposed PEH architecture and controls is conducted through a controller hardware in the loop validation.

Starke, Michael↗

Prediction of DIII-D Pedestal Structure From Externally Controllable Parameters

The sharp increase of pressure at the edge of a high confinement mode (H-mode) plasma, the pedestal, strongly impacts overall plasma performance. Predicting the pedestal is a necessity to control and optimize tokamak operations. Here, an experimental data-driven machine learning (ML) approach is presented that predicts the pedestal heights and widths of electron density (n e ) and electron temperature (T e ) profiles as well as the separatrix ne from externally controllable parameters such as the plasma shape, heating method and power, and gas puff rate and integrated gas puff. The OMFIT framework was used with DIII-D data to efficiently, robustly, and automatically build a database of pedestal parameters to train machine learning models. Database creation was enabled by the search engine tool for DIII-D data, TokSearch, which parallelizes data fetching, enabling fast searches through basic signals of thousands of DIII-D shots and selection of relevant time intervals. Principal Component Analysis (PCA) separated the database into three clusters that represent classes of plasma shapes that are regularly used in DIII-D. The most important parameters for setting the pedestal structure were plasma current (I p ), toroidal magnetic field (B Φ ), neutral beam heating power (P NBI ) and shaping quantities. The Deep Jointly Informed Neural Networks (DJINN) algorithm was applied to identify suitable neural network (NN) architectures that appropriately capture the features of the pedestal database. Separate NNs were implemented for each pedestal parameter, and ensembling methods were used to improve the prediction accuracy and allowed estimation of the prediction uncertainty. The pedestal predictions of the test dataset lie within the measurement uncertainties of the pedestal parameters. The NN outperformed simple Linear Regression (LR) analysis, indicating non-linear dependencies in the pedestal structure. The presented achievements illustrate a promising path for future research, using feature extraction to infer experimental trends and thereby improve pedestal models as well as deploying NN for a fast pedestal prediction in DIII-D scenario development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FORK: fine grained occupancy estimatoR using kinect on ARM embedded platforms

Occupancy estimation is very useful for a wide range of smart building applications including energy efficiency, safety, and security. In this demonstration, we present a novel solution called FORK, which uses a Kinect depth sensor for estimating occupancy in real-time. Unlike other camera-based solutions, FORK is much less privacy invasive (even if the sensor is compromised) and it does not require a powerful machine like a Microsoft XBOX or an Intel® Core™ i7 processor to process the depth data. Our system performs the entire depth data processing on a cheaper and lower-power ARM processor, in real-time. In order to do that, FORK uses a novel lightweight human model by leveraging anthropometric properties of human bodies for detecting individuals. We will show how FORK detects, tracks, and counts occupants accurately in real-time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polynomial Chaos Characterization of Uncertainty in Multiscale Models and Behavior of Carbon Reinforced Composites

Design of non-crimp fabric (NCF) composites entails major challenges pertaining to (1) the complex fine-scale morphology of the constituents, (2) the manufacturing-produced inconsistency of this morphology spatially, and thus (3) the ability to build reliable, robust, and efficient computational surrogate models to account for this complex nature. Traditional approaches to construct computational surrogate models have been to average over the fluctuations of the material properties at different scale lengths. This fails to account for the fine-scale features and fluctuations in morphology, material properties of the constituents, as well as fine-scale phenomena such as damage and cracks. In addition, it fails to accurately predict the scatter in macroscopic properties, which is vital to the design process and behavior prediction. In this work, funded in part by the Department of Energy, we present an approach for addressing these challenges by relying on polynomial chaos representations of both input parameters and material properties at different scales. Moreover, we emphasize the efficiency and robustness of integrating the polynomial chaos expansion with multiscale tools to perform multiscale assimilation, characterization, propagation, and prediction, all of which are necessary to construct the data-driven surrogate models required to design under the uncertainty of composites. These data-driven constructions provide an accurate map from parameters (and their uncertainties) at all scales and the system-level behavior relevant for design. While this perspective is quite general and applicable to all multiscale systems, NCF composites present a particular hierarchy of scales that permits the efficient implementation of these concepts.

42 ENGINEERING↗

LED Surgical Task Lighting Scoping Study: A Hospital Energy Alliance Project

Tungsten-halogen (halogen) lamps have traditionally been used to light surgical tasks in hospitals, even though they are in many respects ill-suited to the application due to the large percentage of radiant energy outside the visible spectrum and issues with color rendering/quality. Light-emitting diode (LED) technology offers potential for adjustable color and improved color rendition/quality, while simultaneously reducing side-effects from non-visible radiant energy. It also has the potential for significant energy savings, although this is a fairly narrow application in the larger commercial building energy use sector. Based on analysis of available products and Hospital Energy Alliance member interest, it is recommended that a product specification and field measurement procedure be developed for implementation in demonstration projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Standard 90.1-2007 for Commercial Buildings at State Level

This report examines the requirements of Standard 90.1-2007 on commercial buildings on a state-by-state basis with a separate, stand-alone chapter for each state. Standard 90.1-2007 is compared to the current state code for most states. This is the final version of the draft previously cleared and assigned ERICA # PNNL-18544, titled "Commercial Nationwide Report."

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗