Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Meteorological environments associated with California wildfires and their potential roles in wildfire changes during 1984-2017

California has been seeing more wildfires in recent years, resulting in huge economic losses and threatening human health. Clarifying the meteorological environments of wildfires is foundational to improving the understanding and prediction of wildfires and their impacts. Here, 1535 California wildfires during 1984-2017 are systematically investigated. Based on two key meteorological factors - temperature and moisture anomalies - all wildfires are classified into four groups: hot-dry, hot-wet, cold-dry, cold-wet. Most (~60%) wildfires occurred on hot-dry days. Compositing the large-scale environments of the four groups shows that persistent high pressure and strong northeasterly wind descending from inland favor hot-dry conditions for wildfires. This analysis also reveals an important role of anomalies in southerly onshore flow that supports stronger convection, accompanied by more lightning flashes that provide a triggering mechanism for wildfires under hot-wet conditions. Self-organizing map analysis lends confidence in the large-scale meteorological pattern for dominating hot-dry wildfires in California. Besides wildfire occurrence, wildfire size is also influenced by meteorological anomalies through their magnitudes. Among them, moisture anomaly explains the largest fraction (~69%) of variability in wildfire sizes. Large-scale meteorological anomalies are found to play an important role in the devastating 2018 wildfire season in California. During 1984-2017, wildfire burned area has significantly increased by ~3.6% per year, indicating a doubling of burned area in 2017 relative to 1984, with the trend dominated by hot-dry wildfires in summer. Drying and warming in conjunction with strengthening of the high pressure in summer support more frequent and larger wildfires in California.

58 GEOSCIENCES↗

Estimation of Sea Spray Aerosol Surface Area Over the Southern Ocean Using Scattering Measurements

This study focuses on methods to estimate dry marine aerosol surface area (SA) from bulk optical measurements. Aerosol SA is used in many models' ice nucleating particle (INP) parameterizations, as well as influencing particle light scattering, hygroscopic growth, and reactivity, but direct observations are scarce in the Southern Ocean (SO). Two campaigns jointly conducted in austral summer 2018 provided co-located measurements of aerosol SA from particle size distributions and lidar to evaluate SA estimation methods in this region. Mie theory calculations based on measured size distributions were used to test a proposed approximation for dry aerosol SA, which relies on estimating effective scattering efficiency (Q) as a function of Ångström exponent (å). For distributions with dry å < 1, Q = 2 was found to be a good approximation within ±50%, but for distributions with dry å > 1, an assumption of Q = 3 as in some prior studies underestimates dry aerosol SA by a factor of 2 or more. We propose a new relationship between dry å and Q, which can be used for –0.2 < å < 2, and suggest å = 0.8 as the cutoff between primary and secondary marine aerosol-dominated distributions. Application of a published methodology to retrieve dry marine aerosol SA from lidar extinction profiles overestimated aerosol SA by a factor of 3–5 during these campaigns. Using Microtops aerosol optical thickness measurements, we derive alternative lidar conversion parameters from our observations, applicable to marine aerosol over the SO.

54 ENVIRONMENTAL SCIENCES↗

SU-D-204-04: Correlations Between Dosimetric Indices and Follow-Up Data for Salivary Glands Six Months After Radiation Therapy for Head and Neck Cancer

Purpose: To investigate the correlation between different dosimetric indices of salivary glands (as separate or combined structures) to patient-reported dry mouth 6 months post radiotherapy using the novel patient reported outcome version of the CTCAE (PRO-CTCAE). Methods: Forty-three patients with oropharyngeal squamous cell carcinoma were treated on a prospective multi-institutional study. All patients received de-intensified 60 Gy intensity modulated radiotherapy. Dosimetric constraints were used for the salivary glands (e.g. mean dose to the contralateral-parotid < 26 Gy). We investigated correlations of individual patient dosimetric data of the parotid and submandibular glands (as separate or combined structures) to their self-reported 6 month post-treatment dry mouth responses. Moderate dry mouth responses were most prevalent and were used as the clinical endpoint indicating response. The correlation of Dmean, Dmax and a range of dosevolume (VD) points were assessed through the area under the Receiver Operating Characteristic curve (ROC) and Odds Ratios (OR). Results: Patients reporting non/mild dry mouth response (N=22) had average Dmean = 19.6 ± 6.2Gy to the contralateral-parotid compared to an average Dmean = 28.0 ± 8.3Gy and an AUC = 0.758 for the patients reporting moderate/severe/very severe dry mouth (N=21). Analysis of the range of VD’s for patients who had reported dry mouth showed that for the contralateral-parotid the indices V18 through V22 had the highest area under the curves (AUC) (0.762 – 0.772) compared to a more traditional dosimetric index V30, which had an AUC = 0.732. The highest AUC was observed for the combination of contralateral parotid and contralateral submandibular glands, for which V16 through V28 had AUC = 0.801 – 0.834. Conclusion: Patients who report moderate/severe/very severe dry mouth 6 months post radiotherapy had on average higher Dmean. The V16-V28 of the combination of the contralateral glands showed the highest correlation with the clinical endpoint.

60 APPLIED LIFE SCIENCES↗

Utilization of Wet Forest Biomass as both the Feedstock and Electricity Source for an Integrated Biochar Production System

Abstract. A belt dryer and gasifier generator set were integrated into a biochar production plant to use process heat to dry biomass feedstock from forest residuals and to provide electric power to the plant using a side stream of dried biomass. Experiments were conducted to characterize the dryer throughput and drying capacity using process heat from a stack heat exchanger attached to the biochar machine flare. A matrix of tests was conducted at high and low flow rates for both the heat exchanger air flow rate (which varied the temperature and heat input to the dryer) and the residence time of feedstock in the belt dryer. Mean feedstock input moisture during dryer characterization was 45% and the mean moisture after exiting the dryer was 27%. The optimal test condition, providing the greatest water removal rate, was determined to have high air flow rate through the heat exchanger and short dryer residence time. This condition was used to demonstrate the integrated system for an 8-h production day. The integrated system dried incoming feedstock from 36% to 22% with a dryer throughput rate of 495 kg h -1 w.b. and an evaporation rate of 88.8 kg h -1 , providing the necessary dry feedstock for the 20-kW gasifier generator set and the biochar machine, which produced 75 kg h -1 of biochar. This system required the operational effort of 0.92 labor hours per production hour. Results from this demonstration indicate that the integrated system provides key benefits in a biochar production operation including greater control of feedstock drying and the ability to operate without an external (non-biomass) source of fuel for electricity generation. Keywords: Biochar, Biomass, Biomass drying, Forest residuals, Gasification, Pyrolysis.

Agriculture↗

Fast Pyrolysis Behavior of Banagrass as a Function of Temperature and Volatiles Residence Time in a Fluidized Bed Reactor

A reactor was designed and commissioned to study the fast pyrolysis behavior of banagrass as a function of temperature and volatiles residence time. Four temperatures between 400 and 600°C were examined as well as four residence times between ~1.0 and 10 seconds. Pyrolysis product distributions of bio-oil, char and permanent gases were determined at each reaction condition. The elemental composition of the bio-oils and chars was also assessed. The greatest bio-oil yield was recorded when working at 450°C with a volatiles residence time of 1.4 s, ~37 wt% relative to the dry ash free feedstock (excluding pyrolysis water). The amounts of char (organic fraction) and permanent gases under these conditions are ~4 wt% and 8 wt% respectively. The bio-oil yield stated above is for 'dry' bio-oil after rotary evaporation to remove solvent, which results in volatiles and pyrolysis water being removed from the bio-oil. The material removed during drying accounts for the remainder of the pyrolysis products. The 'dry' bio-oil produced under these conditions contains ~56 wt% carbon which is ~40 wt% of the carbon present in the feedstock. The oxygen content of the 450°C, 1.4 s 'dry' bio-oil is ~38 wt%, which accounts for ~33 wt% of the oxygen in the feedstock. At higher temperature or longer residence time less bio-oil and char is recovered and more gas and light volatiles are produced. Increasing the temperature has a more significant effect on product yields and composition than increasing the volatiles residence time. At 600°C and a volatiles residence time of 1.2 seconds the bio-oil yield is ~21 wt% of the daf feedstock, with a carbon content of 64 wt% of the bio-oil. The bio-oil yield from banagrass is significantly lower than from woody biomass or grasses such as switchgrass or miscanthus, but is similar to barley straw. In conclusion, the reason for the low bio-oil yield from banagrass is thought to be related to its high ash content (8.5 wt% dry basis) and high concentration of alkali and alkali earth metals (totaling ~2.8 wt% relative to the dry feedstock) which are catalytic and increase cracking reactions during pyrolysis.

60 APPLIED LIFE SCIENCES↗

Development of Technologies and Capabilities for Coal Energy Resources

This is the final report for the Aerojet Rocketdyne (AR) Advanced Gasification Systems Development (AGSD) project that was initiated on October 1, 2004. The project’s primary objective is to demonstrate technologies that improve the availability and efficiency of gasification-based power plants and to reduce plant capital and operational costs. The objective will be accomplished by (1) development and testing of cooled refractory liners, (2) feed system development and demonstration, (3) pilot plant definition and planning, (4) transport gasifier feed analysis, (5) coal-biomass mixture feed analysis, and (6) coal-biomass mixture pilot scale tests. Task 1, development and testing of cooled refractory liners, was conducted at CANMET Energy Technology Centre in Ottawa, Canada. The test objectives were to screen high conductivity CMC materials with alternate manufacturing methods and a variety of surface treatments for cooled metal tubes in a slagging gasifier environment. During the CMC testing, it was found that a constantly cooled CMC will survive in good conditions and that high porosity CMC resulted in high material erosion and corrosion. During cooled tube testing, it was found that hard metal spray coat and bare Haynes 188 performed the best. Task 2, feed system development and demonstration, was conducted at at the Energy and Environmental Research Center (EERC) at the University of North Dakota (UND). For tasks 2.1-2.6, the test objective was to demonstrate 400-tons/day coal feed system operation (to 1,000 psia gasifier pressures) in ultra-dense phase flow without plugging and to achieve multi-element injector flow-split non-uniformities below 2 %RSD. Testing was successfully completed with no feed system plugging of the feed system. The majority of the other Task 2 activities were associated with the Dry Solids Pump design (Task 2.8 and 2.11), development (Task 2.10), fabrication (Task 2.12), amd testing (Task 2.13-2.15). A variety of tests were performed that verified the capability of the Dry Solids Pump to consolidate various pulverized feedstocks to a state capable of sealing and sustaining downstream outlet pressures during mechanical operation of the pump as well as during periods when the pump was turned off. However, the final operating goals were not achieved. Task 3, pilot plant definition and planning, was to define requirements for an advanced commercial gasifier with a cooled liner and to establish a preferred commercial gasifier system configuration to serve as the reference point for an advanced gasifier pilot plant concept definition. A pilot plant concept was successfully defined that is scalable and traceable to the commercial gasifier configuration. The schedule and cost for design, installation, and long-duration test operation of a pilot plant were estimated at 33 months and $\$$25.6M. Taks 4, transport gasifier feed analysis, was to determine the effects of larger sized transport gasifier low rank coals within the AR dry solids pump. It was found for the two low-rank +100 mesh size transport gasifier coals that the cohesion of these larger materials was significantly less than the coals ground to minus 200 mesh. Also, the gas permeability of the MSL transport coal was found to be significantly higher than the permeability of the PRB transport coal. Task 5, coal-biomass mixture feed analysis, was to determine the effects of coal biomass blends within the AR ultra-dense phase feed system and dry solids pump, and to determine the cost of electricity increase of an integrated gasification combined cycle (IGCC) operating on coal/biomass blends with the AR dry solids pump and ultra-dense phase feed system. In summary, it was found that 75/25 wt% coal/corn stover blends produce reasonable economic results for IGCC operation with minimal dry solids pump modifications – especially if the coal is a low rank coal and the corn stover biomass is pelletized. The increase in electricity cost was found to be 1.1 cents/kWh. Task 6, coal-biomass mixture pilot scale tests, was to determine which coal/biomass blends could be tested in the current dry solids pump without major modifications. As reported in detail in the reports by Sprouse (2010) and Sprouse and Darby (2013), the coal/biomass blend having the least impact on pump configuration and operation is the 90/10 wt% Illinois #6 to corn stover ratio blend. The AGSD program was initiated on October 1, 2004. The interim final report was submitted on October 21, 2010 and covered Task 1, Task 2.1-2.9, and Task 3, performed during budget period 1. This final report covers Task 2.10-2.16, 4, 5, and 6, performed during budget period 2. The interim final report is attached as part of the appendix to this report.

Darby, Alan K.↗

THE USE OF DI WATER TO MITIGATE DUSTING FOR ADDITION OF DWPF FRIT TO THE SLURRY MIX EVAPORATOR

The Defense Waste Processing Facility (DPWF) presently is in the process to determine means to reduce water utilization in the Slurry Mix Evaporator (SME) process, thus reducing effluent and processing times. The frit slurry addition system mixes the dry frit with water, yielding approximately a 50 weight percent slurry containing frit and the other fraction water. This slurry is discharged into the SME and excess water is removed via boiling. To reduce this water load to the SME, DWPF has proposed using a pneumatic system in conveying the frit to the SME, in essence a dry delivery system. The problem associated with utilizing a dry delivery system with the existing frit is the generation of dust when discharged into the SME. The use of water has been shown to be effective in the mining industry as well in the DOE complex to mitigate dusting. The method employed by SRNL to determine the quantity of water to mitigate dusting in dry powders was effective, between a lab and bench scale tests. In those tests, it was shown that as high as five weight percent (wt%) of water addition was required to mitigate dust from batches of glass forming minerals used by the Waste Treatment Plant at Hanford, Washington. The same method used to determine the quantity of water to mitigate dusting was used in this task to determine the quantity of water to mitigate this dusting using as-received frit. The ability for water to mitigate dusting is due to its adhesive properties as shown in Figure 1-1. Wetting the frit particles allows for the smaller frit particles (including dust) to adhere to the larger frit particles or to agglomerate into large particles. Fluids other than water can also be used, but their adhesive properties are different than water and the quantity required to mitigate dusting is different, as was observed in reference 1. Excessive water, a few weight percentages greater than that required to mitigate dusting can cause the resulting material not to flow. The primary objective of this task is to perform bench scale testing on various frits that have been used at DWPF or in test programs at SRNL to determine the quantity of de-ionized (DI) water required to mitigate dusting per mass basis of frit. The quantity of DI water required was determined visually by observing the effluent port of the mixer, and DI water addition was made to the point where no visible dust was observed leaving the effluent port. A total of eight different frits were selected for testing. Secondary objectives in this task include the following: (1) Video taping of the de-dusting procedure, (2) Particle size distribution analyses of the dry and wetted frits at the weight fraction of water required for de-dusting, (3) Plate flow tests to determine angle of flow and quantity of material remaining on plate at 90 degrees, (4) Microscopy of dry and wetted frit, and (5) Effect of excess water for selected frits on plate flow. The above analyses were performed within one hour of water addition, to minimize the effect of evaporative water losses. To better understand the size of dust particles, perform settling tests on selected frits and capture the fines. Analyze the fines for particle size distribution. Finally, it is expected that the surface area of frit is an important parameter in the quantity of water required for dust mitigation. An analysis of particle size distribution (PSD) data of as-received frit analyzed by SRNL over the past two to three years will be performed to determine the variation in the distribution of as-received frit. The following objectives were stated in the Technical Task Request4 as objectives that given adequate time would provide insight in helping DWPF in assessing equipment or processes for de-dusting and processing of dry frit. Due to time constraints, commercial methods for dedusting are provided. These results are detailed in section 3.7. Obtain design information from Hanford with respective to equipment used for dedusting. Suggestions on enhanced design features, such as flush water, pipe air purges, humidified compressed air, options for agitation, and other base (SRNL) knowledge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Melting Behavior of Hydrogen Direct Reduced Iron in Molten Steel and Slag: An Integrated Computational and Experimental Study

Direct reduced iron (DRI) and hot briquetted iron (HBI) are essential feedstocks for tramp element control in the electric arc furnace (EAF). Due to greenhouse gas (GHG) concerns related to CO2 emissions, hydrogen as a substitute for natural gas and a reductant in DRI production is being widely explored to reduce GHG emissions in ironmaking. This study examines the melting behavior of hydrogen DRI (H-DRI) pellets in the EAF containing low-carbon (0.1 wt.%) molten steel and molten slag. A computational heat transfer model was developed to predict the melting behavior of H-DRI pellets. To validate the model, a set of experimental laboratory simulations was conducted by immersing H-DRI in a molten steel bath and slag. The temperature history at the center of the pellet during melting and the shell thickness at different melting stages were utilized to validate the model. The simulation results agree with the experimental measurements of steel balls and H-DRI in different metallic molten steel and slag baths.

Materials Science↗

Overview: Precipitation characteristics and sensitivities to environmental conditions during GoAmazon2014/5 and ACRIDICON-CHUVA

This study provides an overview of precipitation processes and their sensitivities to environmental conditions in the Central Amazon Basin near Manaus during the GoAmazon2014/5 and ACRIDICON-CHUVA experiments. Here, this study takes advantage of the numerous measurement platforms and instrument systems operating during both campaigns to sample cloud structure and environmental conditions during 2014 and 2015; the rainfall variability among seasons, aerosol loading, land surface type, and topography has been carefully characterized using these data. Differences between the wet and dry seasons were examined from a variety of perspectives. The rainfall rates distribution, total amount of rainfall, and raindrop size distribution (the mass-weighted mean diameter) were quantified over both seasons. The dry season generally exhibited higher rainfall rates than the wet season and included more intense rainfall periods. However, the cumulative rainfall during the wet season was 4 times greater than that during the total dry season rainfall, as shown in the total rainfall accumulation data. The typical size and life cycle of Amazon cloud clusters (observed by satellite) and rain cells (observed by radar) were examined, as were differences in these systems between the seasons. Moreover, monthly mean thermodynamic and dynamic variables were analysed using radiosondes to elucidate the differences in rainfall characteristics during the wet and dry seasons. The sensitivity of rainfall to atmospheric aerosol loading was discussed with regard to mass-weighted mean diameter and rain rate. This topic was evaluated only during the wet season due to the insignificant statistics of rainfall events for different aerosol loading ranges and the low frequency of precipitation events during the dry season. The impacts of aerosols on cloud droplet diameter varied based on droplet size. For the wet season, we observed no dependence between land surface type and rain rate. However, during the dry season, urban areas exhibited the largest rainfall rate tail distribution, and deforested regions exhibited the lowest mean rainfall rate. Airplane measurements were taken to characterize and contrast cloud microphysical properties and processes over forested and deforested regions. Vertical motion was not correlated with cloud droplet sizes, but cloud droplet concentration correlated linearly with vertical motion. Clouds over forested areas contained larger droplets than clouds over pastures at all altitudes. Finally, the connections between topography and rain rate were evaluated, with higher rainfall rates identified at higher elevations during the dry season.

54 ENVIRONMENTAL SCIENCES↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Techno-Economics for Conversion of Lignocellulosic Biomass to Ethanol by Indirect Gasification and Mixed Alcohol Synthesis

This techno-economic study investigates the production of ethanol and a higher alcohols coproduct by conversion of lignocelluosic biomass to syngas via indirect gasification followed by gas-to-liquids synthesis over a precommercial heterogeneous catalyst. The design specifies a processing capacity of 2,205 dry U.S. tons (2,000 dry metric tonnes) of woody biomass per day and incorporates 2012 research targets from NREL and other sources for technologies that will facilitate the future commercial production of cost-competitive ethanol. Major processes include indirect steam gasification, syngas cleanup, and catalytic synthesis of mixed alcohols, and ancillary processes include feed handling and drying, alcohol separation, steam and power generation, cooling water, and other operations support utilities. The design and analysis is based on research at NREL, other national laboratories, and The Dow Chemical Company, and it incorporates commercial technologies, process modeling using Aspen Plus software, equipment cost estimation, and discounted cash flow analysis. The design considers the economics of ethanol production assuming successful achievement of internal research targets and nth-plant costs and financing. The design yields 83.8 gallons of ethanol and 10.1 gallons of higher-molecular-weight alcohols per U.S. ton of biomass feedstock. A rigorous sensitivity analysis captures uncertainties in costs and plant performance.

09 BIOMASS FUELS↗

Oxide Growth and Validation for Aluminum Research Reactor Fuel - 19422

Aluminum fuel cladding will undergo general corrosion with resulting formation of adherent oxide films during in-reactor and post-discharge exposures under various water conditions and temperatures. These oxides include chemically-bound water that can pose challenges for extended dry storage. This paper describes laboratory experiments performed to produce hydroxide (oxide) films on aluminum 1100, 6061 and 5052 series alloy substrates immersed in water at controlled temperatures. The results are compared to the oxide film present on a spent fuel assembly irradiated in research reactor. This work is part of a broad investigation to address knowledge gaps and technical data needs for dry storage of aluminum-clad spent nuclear fuel (SNF). To adequately assess the risks posed by chemically-bound water on SNF in dry storage and strategies for removing chemically bound water, it is necessary to understand the expected composition and loading of oxide films on SNF of different service histories and to investigate the response of such oxides to irradiation and potential drying methods. These efforts require both the growth of films under controlled conditions and the production of non-radioactive surrogates for testing. The current work comprises experimental investigation of oxide growth via (1) laboratory experiments to produce hydroxide films on aluminum alloy substrates immersed in water at controlled temperatures and (2) characterization and comparison of laboratory-grown oxides to oxides on service-exposed aluminum alloys. The important factors affecting oxide growth and characteristics typical of oxide films formed by aqueous corrosion under conditions similar to in-reactor are reviewed. Aluminum oxide films were grown under a variety of controlled temperature conditions and durations to serve as surrogates for oxides found on aluminum-clad spent nuclear fuel due to aqueous corrosion. The chemically-bound water found in oxides formed by aqueous corrosion poses challenges for extended dry storage, requiring investigation of how the oxide loading and characteristics vary with exposure history and to provide the initial condition for investigation of drying methods. Characteristics including chemical composition, oxide morphology, and film thickness were measured to assess whether the surrogate films were representative of in-service-produced oxides on SNF. Tests were conducted in liquid water at atmospheric pressure in the temperature range 50-100 deg. C, with and without heat flux through the corroding surface, to replicate in-service conditions, and at 185 deg. C inside pressure vessels to replicate pre-filming procedures. Three different alloys commonly used in aluminum clad research reactor fuel were considered: Al-1100, Al-6061, and Al-5052. Specimens were characterized by weighing before and after exposure to measure oxide mass loading, X-ray diffraction to identify oxide composition, and scanning electron microscopy to examine the oxide morphology and film thickness. The oxide type and the morphological characteristics of the film on a fuel element from the Uruguay RU1 research reactor were determined and compared to the laboratory surrogates. The results show some differences compared to the 50 deg. C laboratory specimen that are rationalized with the service storage history of the element. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Consequence Analysis of Residual Water in a Storage Canister - 20484

Recent observations from projects sponsored under the DOE-Nuclear Energy Spent Fuel and Waste Disposition campaign show that residual free water, well above the 0.4 gm-moles that correspond to a 3 torr rebound pressure after a 30-minute hold following prototypic drying, may remain within SNF canisters used for long-term dry storage. Specifically, experimental observations in an Integrated Research Project showed subzero temperatures and a local pocket of frozen water in a mockup fuel assembly subjected to an industry practiced drying process. In gas sampling and analysis from the High Burnup (HBU) Demonstration project, using a fully loaded and dried SNF canister, indicated presence of 100 g of residual water had remained in the canister. The effects of residual water in terms of potential adverse impacts on the condition of the SNF and the canister internals during long-term dry storage has been rigorously evaluated to address inadvertent residual water contents. The impact of residual water on the fuel and canister internals, with a focus on the oxidation of the cladding and of postulated exposed (breached-clad) fuel, were evaluated using an integrated set of time-dependent environmental conditions with semi-empirical materials oxidation models. An 'integration model,' with coupled sub-models, developed and previously used by the Center for Nuclear Waste Regulatory Analysis (CNWRA), was applied and expanded with improved sub-models for water radiolysis, and for cladding and fuel oxidations. Cladding oxidation models for various alloys were developed using the rate constants for various cladding alloys in the dry storage temperature range. A burnup-dependent fuel oxidation model was developed; it accounted for inhibition effect of fission products on fuel oxidation rates. The potential for extension of the initial breach flaw (1 mm hole) was evaluated by two separate mechanics criteria. In the first case, a critical cladding strain criterion was used. In the second case, a critical stress intensity was used to evaluate stability of a planar axial flaw postulate. A failure condition exists when a sufficient amount of fuel oxidation (at the postulated breached-clad location) causes fuel pellet swelling to load the cladding to meet a mechanics criterion for flaw extension. The integration model's results provide the following insights. The radiolysis-generated oxygen is consumed with a partitioning between the cladding and the fuel. The extent of cladding oxidation is no more than 2 μm additional consumption of the cladding metal even with 10 moles of residual water, indicating that changes in cladding conditions due to water are expected to be negligible. The conditions for cladding failure (breach opening size extension) directly correlates with the extent of fuel oxidation. Fuel oxidation significant to extend the breach could occur even with 5.5 moles of residual water. The results indicate that fuel oxidation vis-a-vis cladding oxidation is more likely under a higher radiation field, i.e., when radiolytic decomposition of the residual water occurs in few years compared to several decades, and that the conditions to cause failure are increased with fuel and cladding temperatures approaching the peak storage temperature limit of 400 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water-insoluble Silk Films with Silk I Structure

Water-insoluble regenerated silk materials are normally produced by increasing the {beta}-sheet content (silk II). In the present study water-insoluble silk films were prepared by controlling the very slow drying of Bombyx mori silk solutions, resulting in the formation of stable films with a predominant silk I instead of silk II structure. Wide angle X-ray scattering indicated that the silk films stabilized by slow drying were mainly composed of silk I rather than silk II, while water- and methanol-annealed silk films had a higher silk II content. The silk films prepared by slow drying had a globule-like structure at the core surrounded by nano-filaments. The core region was composed of silk I and silk II, surrounded by hydrophilic nano-filaments containing random turns and {alpha}-helix secondary structures. The insoluble silk films prepared by slow drying had unique thermal, mechanical and degradative properties. Differential scanning calorimetry results revealed that silk I crystals had stable thermal properties up to 250 C, without crystallization above the T{sub g}, but degraded at lower temperatures than silk II structure. Compared with water- and methanol-annealed films the films prepared by slow drying had better mechanical ductility and were more rapidly enzymatically degraded, reflecting the differences in secondary structure achieved via differences in post processing of the cast silk films. Importantly, the silk I structure, a key intermediate secondary structure for the formation of mechanically robust natural silk fibers, was successfully generated by the present approach of very slow drying, mimicking the natural process. The results also point to a new mode of generating new types of silk biomaterials with enhanced mechanical properties and increased degradation rates, while maintaining water insolubility, along with a low {beta}-sheet content.

36 MATERIALS SCIENCE↗

Thermoelectric heating and cooling–integrated dishwasher with thermal energy storage

Household dishwashers must address several performance goals: maximize washing and drying performance, while minimizing cycle duration, energy consumption, and water consumption. This study develops and examines a novel thermoelectric heating and cooling (TEHC) system with thermal energy storage applied to a household dishwasher (DW), aiming to improve the energy and drying performance of a commercially-available dishwasher while maintaining its washing performance, water consumption, and cycle duration. Experimental testing conducted on the novel TEHC-DW system demonstrates an 8.7% reduction in total energy consumption, lowering the per-cycle usage to 0.952 kWh, and a 40% reduction in energy consumption for internal water heating. The novel TEHC-DW system also demonstrates better drying performance, shortening the drying time by 42% to reach the same remaining moisture content as a commercially-available system. In addition, a resistance-capacitance network model is developed that predicts total drying time, total energy consumption, and the highest temperature reached in the tub (53.4 °C). The model accuracy is validated with experimental data (within ±1 K), and the model functions as a design tool via a parametric study to evaluate the next-generation design and the effect of the number of thermoelectric modules and thermoelectric driving force (i.e., current). Overall, this study demonstrates the potential for TEHC technology to improve energy efficiency and drying performance in household dishwashers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of moisture on adsorption isotherms and adsorption capacities of CO{sub 2} on coals

The effect of moisture on the adsorption isotherms and adsorption capacities of CO{sub 2} on Argonne Premium coals has been investigated. In some experiments a small hysteresis was observed between the adsorption and desorption isotherms. The hysteresis was absent or negligible for high-rank and as-received coals but was discernible for lower rank and dried coals. An equation that accounted for the volumetric changes when an adsorbate alters the structure of an adsorbent was employed to interpret the data. The best-fit solutions indicate that the coal volume decreases upon drying. The microscopic shrinkage estimated using helium expansion was greater than the shrinkage reported using the bed-height technique. The microscopic shrinkage was 5-10% for low-moisture medium and high-rank coals and up to 40% for low-rank coals having higher moisture contents. The CO{sub 2} swelling of coals during adsorption isotherm measurements was estimated to be about the same as the shrinkage that occurred during the moisture loss. The adsorption capacity, isosteric heat of adsorption, average pore size, and surface area of the as-received (moist) and dried Argonne coals were estimated after accounting for the volume changes. The isosteric heat of adsorption of CO{sub 2} was found to be between 23 and 25 kJ/mol for as-received coals and between 25 and 27 kJ/mol for dried coals, regardless of the rank. The degree of drying was shown to affect the adsorption capacity and the calculated surface area. For dried coals, the adsorption capacity showed the typical 'U-shape' dependence on rank whereas the as-received coals displayed a more linear dependence. A relationship is proposed to quantify the effect of moisture on the adsorption capacity. The mechanism of CO{sub 2} adsorption on moist coals and the implications of the lower adsorption capacity of wet coals to coal seam sequestration of CO{sub 2} are presented. 70 refs., 12 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

HI-STORM Overpack and MPC-32 Thermal-Hydraulic Model with MOOSE Framework

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a MOOSE thermal model of the MPC-32 canister and HI-STORM overpack

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗