Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Factorization and the synthesis of optimal feedback gains for distributed parameter systems

An approach based on Volterra factorization leads to a new methodology for the analysis and synthesis of the optimal feedback gain in the finite-time linear quadratic control problem for distributed parameter systems. The approach circumvents the need for solving and analyzing Riccati equations and provides a more transparent connection between the system dynamics and the optimal gain. The general results are further extended and specialized for the case where the underlying state is characterized by autonomous differential-delay dynamics. Numerical examples are given to illustrate the second-order convergence rate that is derived for an approximation scheme for the optimal feedback gain in the differential-delay problem.

Milman, Mark H.↗

Selecting an Architecture for a Safety-Critical Distributed Computer System with Power, Weight and Cost Considerations

This report presents an example of the application of multi-criteria decision analysis to the selection of an architecture for a safety-critical distributed computer system. The design problem includes constraints on minimum system availability and integrity, and the decision is based on the optimal balance of power, weight and cost. The analysis process includes the generation of alternative architectures, evaluation of individual decision criteria, and the selection of an alternative based on overall value. In this example presented here, iterative application of the quantitative evaluation process made it possible to deliberately generate an alternative architecture that is superior to all others regardless of the relative importance of cost.

Torres-Pomales, Wilfredo↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Validation of a Hot Water Distribution Model Using Laboratory and Field Data

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the ARBI team validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. In addition to completing validation activities, this project looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. Based on these datasets, we conclude that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws. This has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Energy Systems: Security Implications of the Grid of the Future

Distributed Energy Resources (DER) are being added to the nation's electric grid, and as penetration of these resources increases, they have the potential to displace or offset large-scale, capital-intensive, centralized generation. Integration of DER into operation of the traditional electric grid requires automated operational control and communication of DER elements, from system measurement to control hardware and software, in conjunction with a utility's existing automated and human-directed control of other portions of the system. Implementation of DER technologies suggests a number of gaps from both a security and a policy perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of a Hot Water Distribution Model Using Laboratory and Field Data

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the Building America research team ARBI validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. This project also looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. The team concluded that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws, which has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Suboptimal shape control for quasi-static distributed-parameter systems

An on-line control approach which will adjust the steady-state shape of a large antenna arbitrarily close to any achievable desired profile is approached. The method makes use of distributed-parameter system theory and allows refocusing using a limited number of control actuators and sensors. The controller gains are calculated by approximating the solution to an infinite-dimensional optimal quasi-static control problem. The controller gain calculation is computationally simpler than that previously proposed. The Galerkin (finite element) approximation method is used for model reduction. It is proved that both gain and state convergence can be achieved by using the proposed approximation scheme.

Balas, M. J.↗

Relaying for Distribution and Microgrids Evolving from Radial to Bidirectional Power Flow

As distributed energy resources (DERs) achieve higher penetration levels in distribution systems, the normal flow of power (and fault current) is no longer unidirectional, from substation source to load (or fault). The increased importance of DERs has also led to revisions in the DER interconnection standards, particularly voltage regulation and ride-through, with publication of a new IEEE Standard 1547 2018. These changes have complicated normal distribution system operation, and they will also complicate distribution system protection. The U.S. Department of Energy undertook a review of the protection state of the art for this new environment in order to identify gaps and propose near-term solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phasor-Based Adaptive Control of a Test-Feeder Distribution Network

Control in the power distribution system is needed to match the generation of electricity (that is, supply) with the demand for power (that is, load) at all times while maintaining a high level of power quality [1] (see "Summary"). The complexity of controlling the electric distribution system increases when distributed intermittent energy sources, such as solar photovoltaics (PVs), displace large-scale dispatchable generation [2]-[10]. Furthermore, if the supply from distributed resources exceeds the time-varying demand across a feeder, then the feeder-level voltage will increase. In extreme cases, large voltage increases will trigger the disconnection of distributed generation to protect electrical equipment and ensure customer safety. Consequently, coordinating renewable energy sources that are distributed throughout the distribution system-to match real-time demand across an entire power network-brings the additional challenge of maintaining a high level of supply reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilizing Electric Vehicles to Assist Integration of Large Penetrations of Distributed Photovoltaic Generation Capacity

This analysis provides detailed distribution-level insights into the leveraging potential of distributed rooftop photovoltaic (PV) technologies and electric vehicle (EV) charging. Either of the two technologies by themselves – at some high penetrations – may cause some voltage control challenges or overloading problems, respectively. But when combined, there could be synergistic effects, at least intuitively, whereby one technology mitigates the negative impacts of the other. High penetration of EV charging may overload existing distribution system components, most prominently the secondary transformer. If PV technology is installed at residential premises or anywhere downstream of the secondary transformer, it will provide another electricity source, thus relieving the loading on the transformers. Another synergetic or mitigating effect could be envisioned when high PV penetration reverses the power flow upward in the distribution system (from the homes upstream into the distribution system). Protection schemes may then no longer function as designed and voltage violations (exceeding the voltage upper limit of the American National Standards Institute (ANSI) voltage range) may occur. In this particular situation, EV charging could consume the generated energy from the PV, such that the reversal of power flow can be reduced or alleviated. Given these potential mutual synergistic behaviors of PV and EV technologies, this project attempted to quantify the benefits of combining the two technologies.

Tuffner, Francis K.↗

Software fault tolerance in computer operating systems

This chapter provides data and analysis of the dependability and fault tolerance for three operating systems: the Tandem/GUARDIAN fault-tolerant system, the VAX/VMS distributed system, and the IBM/MVS system. Based on measurements from these systems, basic software error characteristics are investigated. Fault tolerance in operating systems resulting from the use of process pairs and recovery routines is evaluated. Two levels of models are developed to analyze error and recovery processes inside an operating system and interactions among multiple instances of an operating system running in a distributed environment. The measurements show that the use of process pairs in Tandem systems, which was originally intended for tolerating hardware faults, allows the system to tolerate about 70% of defects in system software that result in processor failures. The loose coupling between processors which results in the backup execution (the processor state and the sequence of events occurring) being different from the original execution is a major reason for the measured software fault tolerance. The IBM/MVS system fault tolerance almost doubles when recovery routines are provided, in comparison to the case in which no recovery routines are available. However, even when recovery routines are provided, there is almost a 50% chance of system failure when critical system jobs are involved.

Iyer, Ravishankar K.↗

High-Penetration PV Deployment in the Arizona Public Service System, Phase 1 Update: Preprint

In an effort to better understand the impacts of high penetrations of photovoltaic generators on distribution systems, Arizona Public Service and its partners have begun work on a multi-year project to develop the tools and knowledge base needed to safely and reliably integrate high penetrations of utility- and residential-scale photovoltaics (PV). Building upon the APS Community Power Project --Flagstaff Pilot, this project will analyze the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.3 MW of PV that will be installed on the feeder (both smaller units at homes as well as large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters are being designed andinstalled to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models will be used to analyze the impacts of the PV on distribution circuit protection systems (including anti-islanding), predict voltage regulation and phase balance issues, and develop volt/var control schemes. This paper continues from a paper presented at the2011 IEEE PVSC conference that introduces the project and describes some of the preliminary consideration, as well as project plans and early results. This paper gives a status update of the project and presents selected results from Phase 2 of the project. It discusses baseline feeder modeling, load allocation, data acquisition, utility-scale PV integration, preliminary model validation, andplans for future phases.

14 SOLAR ENERGY↗

A framework for real-time distributed expert systems: On-orbit spacecraft fault diagnosis, monitoring and control

Control of on-orbit operation of a spacecraft requires retention and application of special purpose, often unique, knowledge of equipment and procedures. Real-time distributed expert systems (RTDES) permit a modular approach to a complex application such as on-orbit spacecraft support. One aspect of a human-machine system that lends itself to the application of RTDES is the function of satellite/mission controllers - the next logical step toward the creation of truly autonomous spacecraft systems. This system application is described.

Mullikin, Richard L.↗

Convergence properties of modal costs for certain distributed parameter systems

A complete modal cost analysis is presented for the vibration of various kinds of simple continua with different boundary conditions. Explicit formulas for the norm of the response (called the 'cost') are derived for these distributed parameter systems. The convergence theorems developed are useful in the model reduction of the equivalent continuum models of large space structures as well as in the selection of finite-element code for control design.

Hu, A.↗

Power System Concepts for the Lunar Outpost: A Review of the Power Generation, Energy Storage, Power Management and Distribution (PMAD) System Requirements and Potential Technologies for Development of the Lunar Outpost

This paper will review potential power system concepts for the development of the lunar outpost including power generation, energy storage, and power management and distribution (PMAD). In particular, the requirements of the initial robotic missions will be discussed and the technologies considered will include cryogenics and regenerative fuel cells (RFC), AC and DC transmission line technology, high voltage and low voltage power transmission, conductor materials of construction and power beaming concepts for transmitting power to difficult to access locations such as at the bottom of craters. Operating conditions, component characteristics, reliability, maintainability, constructability, system safety, technology gaps/risk and adaptability for future lunar missions will be discussed for the technologies considered.

Khan, Z.↗

Protective Relaying for Distribution and Microgrids Evolving from Radial to Bi-Directional Power Flow

As distributed energy resources (DER) achieve higher penetration levels in distribution systems, the normal flow of power (and fault current) is no longer unidirectional, from substation source to load (or fault). The increased importance of DER has also led to pending revisions in the DER interconnection standards, particularly voltage regulation and ride-through, with publication of a new IEEE Standard 1547 expected in early 2018. These changes have complicated normal distribution system operation, and they will also complicate distribution system protection. The U. S. Department of Energy undertook a review of protection state-of-the-art for this new environment in order to identify gaps and propose near-term solutions.

McDermott, Tom↗

Distributed expert systems for ground and space applications

Presented here is the Spacecraft Command Language (SCL) concept of the unification of ground and space operations using a distributed approach. SCL is a hybrid software environment borrowing from expert system technology, fifth generation language development, and multitasking operating system environments. Examples of potential uses for the system and current distributed applications of SCL are given.

Buckley, Brian↗

Towards Improved Real-Time Observability of Behind-Meter PhotoVoltaic Systems: A Data-Driven Approach

The stochasticity in energy supply introduced by increased PV penetration in grid distribution systems can lead to frequent and sudden supply-demand imbalances, thereby causing voltage and frequency fluctuations. Enhanced observability, in real-time, of grid attributes such as real and reactive power flows, power injections/consumption and voltages is becoming increasingly essential to ensure smooth grid operation under these new large-scale PV integration scenarios. Two significant challenges prevent grid operators from achieving this objective: 1) Computational complexity of quasi-static timeseries simulations, and 2) Partial observability of behind-meter grid assets. In this work, we take a step towards this objective by enhancing the observability of smart inverter equipped PV systems located behind AMI meters. Smart inverters convert the DC output of PV systems into real and reactive power, the ratio of which is governed by a power factor setting. This in turn is governed by the real-time voltage at its terminal, as per a pre-set volt/var curve. While it is possible to infer the power factor setting - thereby, real and reactive power injection of the PV system - at each time interval by quasi-static time series simulations, such methods are not scalable to large grid sizes. We propose to reduce the reliance on simulations by developing a deep neural network based data-driven model which predicts the time dependent power factors of the PV systems in the grid. The model uses a small amount of simulated data to learn the dependence of power factor on 1) load and apparent PV power injection (root mean square of real and reactive power) data, and 2) AMI net-load data (for BTM PV assets). Our results show that our model can predict power factors with mean absolute error of less than 6.2% under full observability scenario and under 8.6% under the partial observability scenario. Thus, our data-driven model can reduce the amount of simulations required to compute real and reactive injections from PV systems in the distribution system with or without complete information.

14 SOLAR ENERGY↗