Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Illuminating Galaxy Evolution at Cosmic Noon with ISCEA: the Infrared Satellite for Cosmic Evolution Astrophysics

ISCEA (Infrared Satellite for Cosmic Evolution Astrophysics) is a small astrophysics mission whose Science Goal is to discover how galaxies evolved in the cosmic web of dark matter at cosmic noon. Its Science Objective is to determine the history of star formation and its quenching in galaxies as a function of local density and stellar mass when the Universe was 3-5 Gyrs old (1.2 10 Mpc in each of 50 protocluster (cluster and cosmic web) fields at 1.2 < z < 2.1. ISCEA measures the star formation quenching factor in those fields, and galaxy kinematics with a precision < 50 km/s to deduce the 3D spatial distribution in each field. ISCEA will transform our understanding of galaxy evolution at cosmic noon. ISCEA is a small satellite observatory with a 30cm equivalent diameter aperture telescope with a FoV of 0.32 deg^2, and a multi-object spectrograph with a digital micro-mirror device (DMD) as its programmable slit mask. ISCEA will obtain spectra of 1000 galaxies simultaneously at an effective resolving power of R=1000, with 2.8"x2.8" slits, over the NIR wavelength range of 1.1 to 2.0 microns, a regime not accessible from the ground without large gaps in coverage. ISCEA will achieve a pointing accuracy of <= 2" FWHM over 200s. ISCEA will be launched into a Low Earth Orbit, with a prime mission of 2.5 years. ISCEA's space-qualification of DMDs opens a new window for spectroscopy from space, enabling revolutionary advances in astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of Performance of an Active Well Coincidence Counter Equipped with Boron-Coated Straw Neutron Detectors - 13401

He-3, a very rare isotope of natural helium gas, has ideal properties for the detection of thermal neutrons. As such it has become the standard material for neutron detectors and sees ubiquitous use within many radiometric applications that require neutron sensitivity. Until recently, there has been a fairly abundant supply of He-3. However, with the reduction in nuclear weapons, production of tritium ceased decades ago and the stockpile has largely decayed away, reducing the available He-3 supply to a small fraction of that needed for neutron detection. A suitable and rapidly-deployable replacement technology for neutron detectors must be found. Many potential replacement technologies are under active investigation and development. One broad class of technologies utilizes B-10 as a neutron capture medium in coatings on the internal surfaces of proportional detectors. A particular implementation of this sort of technology is the boron-coated 'straw' (BCS) detectors under development by Proportional Technologies, Inc. (PTi). This technology employs a coating of B-10 enriched boron carbide (B{sub 4}C) on the inside of narrow tubes, roughly 4 mm in diameter. A neutron counter (e.g. a slab, a well counter, or a large assay counter designed to accommodate 200 liter drums) could be constructed by distributing these narrow tubes throughout the polyethylene body of the counter. One type of neutron counter that is of particular importance to safeguards applications is the Active Well Coincidence Counter (AWCC), which is a Los Alamos design that traditionally employs 42 He-3 detectors. This is a very flexible design which can accurately assay small samples of uranium- and plutonium-bearing materials. Utilizing the MCNPX code and benchmarking against measurements where possible, the standard AWCC has been redesigned to utilize the BCS technology. Particular aspects of the counter performance include the single-neutron ('singles') detection efficiency and the time constant for the decrease in neutron population in the counter following a fission event (a.k.a. the die-away time). Results of the modeling and optimization are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping the universe

Maps of the galaxy distribution in the nearby universe reveal large coherent structures. The extent of the largest features is limited only by the size of the survey. Voids with a density typically 20 percent of the mean and with diameters of 5000 km/s are present in every survey large enough to contain them. Many galaxies lie in thin sheet-like structures. The largest sheet detected so far is the 'Great Wall' with a minimum extent of 60/h Mpc x 170/h Mpc, where h is the Hubble constant in units of 100 km/s per Mpc. The frequent occurrence of these structures is one of several serious challenges to our current understanding of the origin and evolution of the large-scale distribution of matter in the universe.

Geller, Margaret J.↗

The Late Pliocene Eltanin Impact: Documentation From Sediment Core Analyses

The expeditions ANT-XII/4 (1995) and ANT-XVIII/5a (2001) of the RV POLARSTERN collected extensive bathymetric and seismic data sets as well as sediment cores from an area in the Bellingshausen Sea (eastern Pacific Southern Ocean) that allow the first comprehensive geoscientific documentation of an asteroid impact into a deep ocean (approx. 5 km) basin, named the Eltanin impact. Impact deposits have now been recovered from a total of more than 20 sediment cores collected in an area covering about 80,000 km2. Combined biomagnetostratigraphic dating places the impact event into the earliest Matuyama Chron, a period of enhanced climate variability. Sediment texture analyses and studies of sediment composition including grain size and microfossil distribution reveal the pattern of impact- related sediment disturbance and the sedimentary processes immediately following the impact event. The pattern is complicated by the San Martin Seamounts (approx. 57.5 S, 91 W), a large topographic elevation that rises up to 3000 m above the surrounding abyssal plain in the area affected by the Eltanin impact. The impact ripped up sediments as old as Eocene and probably Paleocene that have been redeposited in a chaotic assemblage. This is followed by a sequence sedimented from a turbulent flow at the sea floor, overprinted by fall-out of airborne meteoritic ejecta that settled trough the water column. Grain size distribution reveals the timing and interaction of the different sedimentary processes. The gathered estimate of ejecta mass deposited over the studied area, composed of shock-melted asteroidal material and unmelted meteorites including fragments up to 2.5 cm in diameter, point to an Eltanin asteroid larger than the 1 km in diameter size originally suggested as a minimum based on the ANT-XII/4 results. This places the energy released by the impact at the threshold of those considered to cause environmental disturbance at a global scale and it makes the impact a likely transport mechanism explaining the presence of extinct Cenozoic microfossils in the transantarctic Sirius Unit. Although a crater structure representing Eltanin ground zero has not been discovered, the distribution pattern of sediment disturbance and ejecta deposits now allows to better determine the central target area north of the San Martin Seamounts.

Gersonde, R.↗

Independent dosimetric assessment of the model EP917 episcleral brachytherapy plaque

Purpose: To investigate the influence of slot design on dose distributions and dose-volume histograms (DVHs) for the model EP917 plaque for episcleral brachytherapy. Methods: Dimensions and orientations of the slots were measured for three model EP917 plaques and compared to data in the Plaque Simulator (PS) treatment planning software (version 5.7.6). These independently determined coordinates were incorporated into the MCNP Monte Carlo simulation environment to obtain dose from the plaques in a water environment and in a clinical environment with ocular structures. A tumor volume was simulated as 5 mm in apical height and 11 mm in basal diameter. Variations in plaque mass density and composition; slot length, width, and depth; seed positioning; and Ag-marker rod positioning were simulated to examine their influence on plaque central axis (CAX) and planar dose distributions, and DVHs. Results: Seed shifts in a single slot toward the eye and shifts of the{sup 125}I-coated Ag rod within the capsule had the greatest impact on CAX dose distribution. A shift of 0.0994 mm toward the eye increased dose by 14%, 9%, 4.3%, and 2.7% at 1, 2, 5, and 10 mm, respectively, from the inner sclera. When examining the fully-modeled plaque in the ocular geometry, the largest dose variations were caused by shifting the Ag rods toward the sclera and shifting the seeds away from the globe when the slots were made 0.51 mm deeper, causing +34.3% and −69.4% dose changes to the outer sclera, respectively. At points along the CAX, dose from the full plaque geometry using the measured slot design was 2.4% ± 1.1% higher than the manufacturer-provided slot design and 2.2% ± 2.3% higher than the homogeneous calculation of PS treatment planning results. The ratio of D{sub 10} values for the measured slot design to the D{sub 10} values for the manufacturer-provided slot design was higher by 9%, 10%, and 19% for the tumor, inner sclera, and outer sclera, respectively. In comparison to the measured slot design, a theoretical plaque having narrower and deeper slots delivered 30%, 37%, and 62% lower D{sub 10} doses to the tumor, inner sclera, and outer sclera, respectively. Conclusions: While the measured positions of the slots on the model EP917 plaque were in close agreement (<0.7 mm) with the PS values, small differences in the slot shape caused substantial differences in dose distributions and DVH metrics. Increasing slot depth by 0.1 mm decreased outer scleral dose by 20%, yet shifting the Ag rods in the seeds toward the globe by 0.1 mm increased outer scleral dose by 35%. The clinical medical physicist is advised to measure these types of plaques upon acceptance testing before clinical use to inspect slot shape and position for comparison with data used for treatment planning purposes.

60 APPLIED LIFE SCIENCES↗

TU-F-BRE-04: Development of a High-Resolution EPID Based Dosimetry Strategy for Radiosurgery QA

Purpose: To systematically investigate a high spatial-resolution (0.2mm) electronic portal imaging device (EPID) for CyberKnife (CK) based radiosurgery system quality assurance (QA). Methods: An EPID-based dosimetric measurement technique is applied to CK output measurement and field size verification. A Monte Carlo (MC) simulated pixel-to-pixel EPID response specific to CK is used to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The output factors are measured using EPID for radiosurgery fields formed by fixed and variable aperture (Iris) cones. Circular fields of 5, 7.5, 10, 15, 30 and 60mm diameters are measured and compared with diode measurements. The equivalent diameters are determined by analyzing the area received dose greater than half maximum. Results: For both fixed and Iris cones, the EPID measured output factors of circular fields of 5mm to 60mm diameters are in good agreement with the radiosurgery diode measurements. The mean output differences are 1.0% and 1.5% for fixed and Iris cone respectively. The max differences are 2.2% for the 15mm fixed cone, and 1.8% for the 10mm Iris field. The equivalent diameters derived from the EPID measurements are in good agreement comparing to the water scan result with mean differences of 0.21±0.09mm and 0.02±0.22mm for fixed and Iris cone, respectively. The high detector density EPID is able to measure the whole radiation field and identify the field edge and center. Therefore, there is no need to align the detector center perfectly at field center and the setup time is greatly reduced for QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient dosimetric tool for radiosurgery QA and especially useful in Cyberknife QA for variable aperture collimators.

07 ISOTOPE AND RADIATION SOURCES↗

ALMA CONTINUUM OBSERVATIONS OF A 30 Myr OLD GASEOUS DEBRIS DISK AROUND HD 21997

Circumstellar disks around stars older than 10 Myr are expected to be gas-poor. There are, however, two examples of old (30-40 Myr) debris-like disks containing a detectable amount of cold CO gas. Here we present Atacama Large Millimeter/Submillimeter Array (ALMA) and Herschel Space Observatory observations of one of these disks, around HD 21997, and study the distribution and origin of the dust and its connection to the gas. Our ALMA continuum images at 886 μm clearly resolve a broad ring of emission within a diameter of ∼4.''5, adding HD 21997 to the dozen debris disks resolved at (sub)millimeter wavelengths. Modeling the morphology of the ALMA image with a radiative transfer code suggests inner and outer radii of ∼55 and ∼150 AU, and a dust mass of 0.09 M {sub ⊕}. Our data and modeling hints at an extended cold outskirt of the ring. Comparison with the morphology of the CO gas in the disk reveals an inner dust-free hole where gas nevertheless can be detected. Based on dust grain lifetimes, we propose that the dust content of this gaseous disk is of secondary origin and is produced by planetesimals. Since the gas component is probably primordial, HD 21997 is one of the first known examples of a hybrid circumstellar disk, a thus-far little studied late phase of circumstellar disk evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Variability and associated uncertainty in image analysis for soiling characterization in solar energy systems

The accumulation of soiling on photovoltaic modules and on the mirrors of concentrating solar power systems causes non-negligible energy losses with economic consequences. These challenges can be mitigated, or even prevented, through appropriate actions if the magnitude of soiling is known. Particle counting analysis is a common procedure to characterize soiling, as it can be easily performed on micrographs of glass coupons or solar devices that have been exposed to the environment. Particle counting does not, however, yield invariant results across institutions. The particle size distribution analysis is affected by the operator of the image analysis software and the methodology utilized. The results of a round-robin study are presented in this work to explore and elucidate the uncertainty related to particle counting and its effect on the characterization of the soiling of glass surfaces used in solar energy conversion systems. An international group of soiling experts analyzed the same 8 micrographs using the same open-source ImageJ software package. The variation in the particle analyses results were investigated to identify specimen characteristics with the lowest coefficient of variation (CV) and the least uncertainty among the various operators. The mean particle diameter showed the lowest CV among the investigated characteristics, whereas the number of particles exhibited the largest CV. Additional parameters, such as the fractional area coverage by particles and parameters related to the distribution's shape yielded intermediate CV values. These results can provide insights on the magnitude inter-lab variability and uncertainty for optical and microscope-based soiling monitoring and characterization.

14 SOLAR ENERGY↗

Laser beam-profile impression and target thickness impact on laser-accelerated protons

Experimental results on the influence of the laser focal spot shape onto the beam profile of laser-accelerated protons from gold foils are reported. The targets' microgrooved rear side, together with a stack of radiochromic films, allowed us to deduce the energy-dependent proton source-shape and size, respectively. The experiments show, that shape and size of the proton source depend only weakly on target thickness as well as shape of the laser focus, although they strongly influence the proton's intensity distribution. It was shown that the laser creates an electron beam that closely follows the laser beam topology, which is maintained during the propagation through the target. Protons are then accelerated from the rear side with an electron created electric field of a similar shape. Simulations with the Sheath-Accelerated Beam Ray-tracing for IoN Analysis code SABRINA, which calculates the proton distribution in the detector for a given laser-beam profile, show that the electron distribution during the transport through a thick target (50 {mu}m Au) is only modified due to multiple small angle scattering. Thin targets (10 {mu}m) show large source sizes of over 100 {mu}m diameter for 5 MeV protons, which cannot be explained by multiple scattering only and are most likely the result of refluxing electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an aerosol microphysical module: Aerosol Two-dimensional bin module for foRmation and Aging Simulation (ATRAS)

Number concentrations, size distributions, and mixing states of aerosols are essential parameters for accurate estimation of aerosol direct and indirect effects. In this study, we developed an aerosol module, designated Aerosol Two-dimensional bin module for foRmation and Aging Simulation (ATRAS), that can represent these parameters explicitly by considering new particle formation (NPF), black carbon (BC) aging, and secondary organic aerosol (SOA) processes. A two-dimensional bin representation is used for particles with dry diameters from 40 nm to 10 µm to resolve both aerosol size (12 bins) and BC mixing state (10 bins) for a total of 120 bins. The particles with diameters from 1 to 40 nm are resolved using an additional 8 size bins to calculate NPF. The ATRAS module was implemented in the WRF-chem model and applied to examine the sensitivity of simulated mass, number, size distributions, and optical and radiative parameters of aerosols to NPF, BC aging and SOA processes over East Asia during the spring of 2009. BC absorption enhancement by coating materials was about 50% over East Asia during the spring, and the contribution of SOA processes to the absorption enhancement was estimated to be 10 – 20% over northern East Asia and 20 – 35% over southern East Asia. A clear north-south contrast was also found between the impacts of NPF and SOA processes on cloud condensation nuclei (CCN) concentrations: NPF increased CCN concentrations at higher supersaturations (smaller particles) over northern East Asia, whereas SOA increased CCN concentrations at lower supersaturations (larger particles) over southern East Asia. Application of ATRAS to East Asia also showed that the impact of each process on each optical and radiative parameter depended strongly on the process and the parameter in question. The module can be used in the future as a benchmark model to evaluate the accuracy of simpler aerosol models and examine interactions between NPF, BC aging, and SOA processes under different meteorological conditions and emissions.

Matsui, H.↗

On the relationship between acoustic energy density flux near the jet axis and far field acoustic intensity

By measurement and analysis, the relationship between the distribution of the outflow of acoustic energy over the jet boundary and the far-field intensity is considered. The physical quantity used is the gradient of the pressure evaluated on a geometrical plane at the smallest possible radial distance from the jet axis, but outside the vortical region, in the area where the homogeneous wave equation is reasonably well satisfied. The numerical and experimental procedures involved have been checked out by using a known source. Results indicate that the acoustic power output per unit length of the jet, in the region from which the sound emanates, peaks at approximately 9 diameters downstream. The acoustic emission for a jet Strouhal number of about 0.3 exceeds the emission for all other Strouhal numbers nearly everywhere along the measurement plane. However, the far-field peak intensity distribution obtained from the contribution of each station was found to depend on the spatial extent of the region where sound emanates from the jet, which, in turn, depends more on the far-field angle than on the Strouhal number.

Maestrello, L.↗

Fermilab Muon Campus g-2 Cryogenic Distribution Remote Control System

The Muon Campus (MC) is able to measure Muon g-2 with high precision and comparing its value to the theoretical prediction. The MC has four 300 KW screw compressors and four liquid helium refrigerators. The centerpiece of the Muon g-2 experiment at Fermilab is a large, 50-foot-diameter superconducting muon storage ring. This one-of-a-kind ring, made of steel, aluminum and superconducting wire, was built for the previous g-2 experiment at Brookhaven. Due to each subsystem has to be far away from each other and be placed in the distant location, therefore, Siemens Process Control System PCS7-400, Automation Direct DL205 & DL05 PLC, Synoptic and Fermilab ACNET HMI are the ideal choices as the MC g-2 cryogenic distribution real-time and on-Line remote control system. This paper presents a method which has been successfully used by many Fermilab distribution cryogenic real-time and On-Line remote control systems.

43 PARTICLE ACCELERATORS↗

Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate {sup 125}I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for {approx}4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A semiconductor metasurface with multiple functionalities: A polarizing beam splitter with simultaneous focusing ability

We propose a semiconductor metasurface that simultaneously performs two independent functions: focusing and polarization filtering. The wavefronts of the reflected and transmitted light distributions are precisely manipulated by spatial parametric variation of a subwavelength thin-film Si grating, which inherently possesses polarization filtering properties. We design a 12-μm-wide metasurface containing only nineteen Si grating ridges. Under a 10-μm-wide unpolarized Gaussian beam incidence at wavelength of 1.55 μm, the resulting device shows promising theoretical performance with high power efficiency exceeding 80% and polarization extinction ratio of ∼10 dB with focal spot diameters near 1–2 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular-Weight-Dependent Infiltration and Adsorption of Polymers into Nanochannels

The mesoporous silica shell coating hydrogenolysis nano-catalysts alters the molecular weight distributions of cleaved polymer chains compared to catalysts without a shell. The shell, composed of radially aligned narrow cylindrical nanopores, reduces the formation of low-valued gaseous products and increases the median molecular weight of the product, thus enhancing the value of the products for polymer upcycling. Here, to understand the role of the mesoporous shell, we have studied the spatial distribution of polystyrene chains, used as a model polymer, in the nanochannels in both the melt phase and solution phase. In the melt, we observed from small-angle X-ray scattering experiments that the infiltration rate of the polymer into the nanochannels is inversely proportional to the molecular weight, which is consistent with theory. In theta solution experiments using UV–vis spectroscopy, we found that the shell significantly enhances polymer adsorption compared to nanoparticles without pores. In addition, the degree of polymer adsorption is not a monotonic function of molecular weight but initially increases with the molecular weight before eventually decreasing. The molecular weight for the peak adsorption increases with the pore diameter. This adsorption behavior is rationalized as resulting from a balance between the mixing entropy gain by surface adsorption and the conformational entropy penalty incurred by chains confined in the nanochannels. The spatial distribution of polymer chains in the nanochannels is visualized by energy-dispersive X-ray spectroscopy (EDX), and inverse Abel-transformed data reveals a less uniform polymer distribution along the primary pore axis for longer chains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation and nonlinear optical properties of indium nanocrystals in sodium borosilicate glass by the sol–gel route

Graphical abstract: The sodium borosilicate glass doped with indium nanocrystals have been successfully prepared by sol–gel methods. And the indium nanocrystals in tetragonal crystal system have formed uniformly in the glass, and the average diameter of indium nanocrystals is about 30 nm. The third-order optical nonlinear refractive index γ, absorption coefficient β, and susceptibility χ{sup (3)} of the glass are determined to be −4.77 × 10{sup −16} m{sup 2}/W, 2.67 × 10{sup −9} m/W, and 2.81 × 10{sup −10} esu, respectively. Highlights: ► Indium nanocrystals embedded in glass matrix have been prepared by sol–gel route. ► The crystal structure and composition are investigated by XRD and XPS. ► Size and distribution of indium nanocrystals is determined by TEM. ► The third-order optical nonlinearity is investigated by using Z-scan technique. -- Abstract: The sodium borosilicate glass doped with indium nanocrystals have been successfully prepared by sol–gel route. The thermal stability behavior of the stiff gel is investigated by thermogravimetric (TG) and differential thermal (DTA) analysis. The crystal structure of the glass is characterized by X-ray powder diffraction (XRD). Particle composition is determined by X-ray photoelectron spectroscopy (XPS). Size and distribution of the nanocrystals are characterized by transmission electron microscopy (TEM) as well as high-resolution transmission electron microscopy (HRTEM). Results show that the indium nanocrystals in tetragonal crystal structure have formed in glass, and the average diameter is about 30 nm. Further, the glass is measured by Z-scan technique to investigate the nonlinear optical (NLO) properties. The third-order NLO coefficient χ{sup (3)} of the glass is determined to be 2.81 × 10{sup −10} esu. The glass with large third-order NLO coefficient is promising materials for applications in optical devices.

36 MATERIALS SCIENCE↗

Soil oxidoreductase zymography: Visualizing spatial distributions of peroxidase and phenol oxidase activities at the root-soil interface

Decomposition of organic material in the rhizosphere – the most dynamic microbial habitat in soil – involves arrays of oxidoreductase and hydrolytic enzymes. Spatial distributions of various hydrolytic activities in soil have already been explored by zymographic techniques. However, the distribution of oxidative activity in the rhizosphere remains to be studied. Thus, we extended a Time-Lapse Zymography technique, using Amplex Red® reagent, to visualize and quantify distributions of phenol oxidase and peroxidase activities in the rhizosphere of Zea mays L. growing in a Haplic Phaeozem and the non-rhizospheric soil. The gross oxidative activity was greatest at the root surfaces, and fell to background soil levels 1.26 and 0.73 mm from seminal (>1 mm diameter) and lateral (<0.5 mm diameter) roots, respectively. The rhizosphere extent relative to the root radius was 59% broader around lateral than around seminal roots. The greatest activities, up to 30 nmol cm –2 min –1 , were peroxidase-dominated and closely associated with roots. Here, the results confirm the utility of the approach for studying spatio-temporal distributions of oxidative activities in soil. However, actual activity of oxidoreductases in the field will be strongly controlled by fluctuating environmental conditions such as soil aeration and the gradient of reactive oxygen species, which need to be considered especially in anoxic soils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational fluid dynamics study of full-scale aerobic bioreactors: Evaluation of gas-liquid mass transfer, oxygen uptake, and dynamic oxygen distribution

Hydrodynamics, oxygen transfer, and oxygen uptake in bubble-column and airlift bioreactors were studied using multiphase Euler-Euler computational fluid dynamics (CFD) simulations. Interphase mass transfer of oxygen was modeled with a liquid mass-transfer coefficient and sustained driving force provided by a phenomenological model for microbial oxygen uptake rate (OUR). Laboratory-scale reactor simulations of a bubble-column (0.15 m diameter and 0.75 m initial liquid height) showed reasonable agreement with gas holdup and mass transfer experiments reported in the literature. Commercial-scale bubble-column and airlift reactor simulations (5 m diameter and 25 m initial liquid height) were simulated using this validated model. Similar trends for the variation of overall gas holdup and oxygen concentrations with superficial velocity were observed for both of the commercial-scale reactors. However, the simulation results indicate differences in hydrodynamics, such as better recirculation in the airlift reactors that enables favorable distribution of oxygen in the reactor.

09 BIOMASS FUELS↗