Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A new GEM based neutron diagnostic concept for high flux neutron beams

Fusion-fission hybrid reactors will need high flux neutron detectors to diagnose the deuterium-tritium fusion plasmas as well as the fission reactions. A candidate detection technique is the Gas Electron Multiplier (GEM). New GEM based detectors are being developed for application to a neutral deuterium beam test facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission due to interaction of the deterium beam with the deuterons implanted in the beam dump surface. This is done by placing a detector in close contact, right behind the dump. CNESM uses nGEM detectors, i.e. GEM detectors equipped with a cathode that also serves as neutron-proton converter foil. A small size prototype of nGEM detector has been built and is ready to be tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Thomson scattering measurements from shock-compressed deuterium

X-ray Thomson scattering has recently been shown to be an effective method of diagnosing a variety of high energy density plasma conditions. We apply this powerful technique to the widely studied problem of shock-compressed liquid deuterium. The behavior of deuterium under extreme conditions has received considerable attention due to its central role in models of giant planets and the importance of the high-pressure insulator-metal transition. We have used spectrally resolved x-ray scattering from electron-plasma waves to perform microscopic observations of ionization during compression. In these experiments, a single shock was launched in cryogenic deuterium reaching compressions of 3x. The 2 keV Ly-{alpha} line in silicon was used as an x-ray source in a forward scattering geometry. In addition to elastic scattering from tightly bound electrons, this low probe energy accessed the collective plasmon oscillations of delocalized electrons. Inelastic scattering from the plasmons allowed accurate measurements of the free electron density through the spectral position of the resonance and provided an estimate of the temperature through its ratio with the elastic feature. Combined with velocity interferometry from the reflective shock front, this lead to a direct determination of the ionization state. We compare the measured ionization conditions with computational models. Additionally, we discuss the possibility of using this technique to determine electrical conductivity and to directly observe pressure-induced molecular dissociation along the Hugoniot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aspect ratio effects on neoclassical tearing modes from comparison between DIII-D and National Spherical Torus Experiment

Neoclassical tearing mode islands are sustained by helically perturbed bootstrap currents arising at finite beta from toroidal effects that trap a fraction of the particles in non-circulating orbits. DIII-D and NSTX are here operated with similar shape and cross-sectional area but almost a factor of two difference in inverse aspect ratio a/R. In these experiments, destabilized n=1 tearing modes were self-stabilized (reached the 'marginal point') by reducing neutral-beam power and thus beta. The measure of the marginal island gives information on the small-island stabilizing physics that in part (with seeding) governs onset. The marginal island width on NSTX is found to be about three times the ion banana width and agrees with that measured in DIII-D, except for DIII-D modes closer to the magnetic axis, which are about two times the ion banana width. There is a balance of the helically perturbed bootstrap term with small island effects with the sum of the classical and curvature terms in the modified Rutherford equation for tearing-mode stability at the experimental marginal point. Empirical evaluation of this sum indicates that while the stabilizing effect of the curvature term is negligible in DIII-D, it is important in NSTX. The mode temporal behavior from the start of neutral-beam injection reduction also suggests that NSTX operates closer to marginal classical tearing stability; this explains why there is little hysteresis in beta between mode onset, saturation, and self-stabilization (while DIII-D has large hysteresis in beta). NIMROD code module component calculations based on DIII-D and NSTX reconstructed experimental equilibria are used to diagnose and confirm the relative importance of the stabilizing curvature effect, an advantage for low aspect ratio; the relatively greater curvature effect makes for less susceptibility to NTM onset even if the classical tearing stability index is near marginal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual transmission grating based imaging radiometer for tokamak edge and divertor plasmas

The designs of single transmission grating based extreme ultraviolet (XUV) and vacuum ultraviolet (VUV) imaging spectrometers can be adapted to build an imaging radiometer for simultaneous measurement of both spectral ranges. This paper describes the design of such an imaging radiometer with dual transmission gratings. The radiometer will have an XUV coverage of 20-200 A with a {approx}10 A resolution and a VUV coverage of 200-2000 A with a {approx}50 A resolution. The radiometer is designed to have a spatial view of 16 Degree-Sign , with a 0.33 Degree-Sign resolution and a time resolution of {approx}10 ms. The applications for such a radiometer include spatially resolved impurity monitoring and electron temperature measurements in the tokamak edge and the divertor. As a proof of principle, the single grating instruments were used to diagnose a low temperature reflex discharge and the relevant data is also included in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diagnosis of intense ion beam by CR-39 detectors analyzing the back scattered particles

A new diagnosis method has been developed utilizing back scattered particles for high energy intense ion beams. The CR-39 detector mounted on the uniform back-scatterer was irradiated with {sup 4}He{sup 2+} ions with an energy 25 MeV/n, which is never recorded as etchable track in CR-39. We found that it is possible to diagnose by analyzing the etch pits on the rear surface of CR-39 that directly contacted on the back-scatterers. It turns out that most of etch pits in the rear surface are made by the backscattered particles by investigating the growth pattern of each etch pit with multi-step etching technique. This method allows simple diagnosis of the ion beam profile and intensity distribution in mixed radiation field such as laser-driven ion acceleration experiments.

43 PARTICLE ACCELERATORS↗

Applications of laser produced ion beams to nuclear analysis of materials

Laser produced ion beams have unique characteristics which are ultra-short pulse, very low emittance, and variety of nuclear species. These characteristics could be used for analyzing various materials like low Z ion doped heavy metals or ceramics. Energies of laser produced ion beam extend from 0.1MeV to 100MeV. Therefore, various nuclear processes can be induced in the interactions of ion beams with samples. The ion beam driven nuclear analysis has been developed for many years by using various electrostatic accelerators. To explore the applicability of laser ion beam to the analysis of the Li ion battery, a proton beam with the diameter of {approx} 1.0 {mu}m at Takasaki Ion Acceleration for Advanced Radiation Application (TIARA), JAEA was used. For the analysis, the PIGE (Particle-Induced Gamma Ray Emission) is used. The proton beam scans over Li battery electrode samples to diagnose Li density in the LiNi{sub 0.85}Co{sub 0.15}O{sub 2} anode. As the results, PIGE images for Li area density distributions are obtained with the spatial resolution of better than 1.5{mu}m FWHM. By the Li PIGE images, the depth dependence of de-intercalation levels of Li in the anode is obtained. By the POP experiments at TIARA, it is clarified that laser produced ion beam is appropriate for the Li ion battery analysis. 41.85.Lc, 41.75.Jv, 42.62.cf.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Suppression of spurious mode oscillation in mega-watt 77-GHz gyrotron as a high quality probe beam source for the collective Thomson scattering in LHD

Collective Thomson scattering (CTS) diagnostic requires a strong probing beam to diagnose a bulk and fast ion distribution function in fusion plasmas. A mega-watt gyrotron for electron cyclotron resonance heating is used as a probing beam in the large helical device. Spurious mode oscillations are often observed during the turning on/off phase of the modulation. The frequency spectra of the 77-GHz gyrotron output power have been measured, and then one of the spurious modes, which interferes with the CTS receiver system, is identified as the TE{sub 17,6} mode at the frequency of 74.7 GHz. The mode competition calculation indicates that the increase of the magnetic field strength at the gyrotron resonator can avoid such a spurious mode and excite only the main TE{sub 18,6} mode. The spurious radiation at the 74.7 GHz is experimentally demonstrated to be suppressed in the stronger magnetic field than that optimized for the high-power operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1.5D quasilinear model and its application on beams interacting with Alfven eigenmodes in DIII-D

We propose a model, denoted here by 1.5D, to study energetic particle (EP) interaction with toroidal Alfvenic eigenmodes (TAE) in the case where the local EP drive for TAE exceeds the stability limit. Based on quasilinear theory, the proposed 1.5D model assumes that the particles diffuse in phase space, flattening the pressure profile until its gradient reaches a critical value where the modes stabilize. Using local theories and NOVA-K simulations of TAE damping and growth rates, the 1.5D model calculates the critical gradient and reconstructs the relaxed EP pressure profile. Local theory is improved from previous study by including more sophisticated damping and drive mechanisms such as the numerical computation of the effect of the EP finite orbit width on the growth rate. The 1.5D model is applied on the well-diagnosed DIII-D discharges no. 142111 [M. A. Van Zeeland et al., Phys. Plasmas 18, 135001 (2011)] and no. 127112 [W. W. Heidbrink et al., Nucl. Fusion. 48, 084001 (2008)]. We achieved a very satisfactory agreement with the experimental results on the EP pressure profiles redistribution and measured losses. This agreement of the 1.5D model with experimental results allows the use of this code as a guide for ITER plasma operation where it is desired to have no more than 5% loss of fusion alpha particles as limited by the design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerologia de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at risk were not surpassed and the patient manifested no extensive morbidity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Freely decaying turbulence in two-dimensional electrostatic gyrokinetics

In magnetized plasmas, a turbulent cascade occurs in phase space at scales smaller than the thermal Larmor radius ('sub-Larmor scales') [Tatsuno et al., Phys. Rev. Lett. 103, 015003 (2009)]. When the turbulence is restricted to two spatial dimensions perpendicular to the background magnetic field, two independent cascades may take place simultaneously because of the presence of two collisionless invariants. In the present work, freely decaying turbulence of two-dimensional electrostatic gyrokinetics is investigated by means of phenomenological theory and direct numerical simulations. A dual cascade (forward and inverse cascades) is observed in velocity space as well as in position space, which we diagnose by means of nonlinear transfer functions for the collisionless invariants. We find that the turbulence tends to a time-asymptotic state, dominated by a single scale that grows in time. A theory of this asymptotic state is derived in the form of decay laws. Each case that we study falls into one of three regimes (weakly collisional, marginal, and strongly collisional), determined by a dimensionless number D{sub *}, a quantity analogous to the Reynolds number. The marginal state is marked by a critical number D{sub *}=D{sub 0} that is preserved in time. Turbulence initialized above this value become increasingly inertial in time, evolving toward larger and larger D{sub *}; turbulence initialized below D{sub 0} become more and more collisional, decaying to progressively smaller D{sub *}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A large volume uniform plasma generator for the experiments of electromagnetic wave propagation in plasma

A large volume uniform plasma generator is proposed for the experiments of electromagnetic (EM) wave propagation in plasma, to reproduce a 'black out' phenomenon with long duration in an environment of the ordinary laboratory. The plasma generator achieves a controllable approximate uniform plasma in volume of 260 mm Multiplication-Sign 260 mm Multiplication-Sign 180 mm without the magnetic confinement. The plasma is produced by the glow discharge, and the special discharge structure is built to bring a steady approximate uniform plasma environment in the electromagnetic wave propagation path without any other barriers. In addition, the electron density and luminosity distributions of plasma under different discharge conditions were diagnosed and experimentally investigated. Both the electron density and the plasma uniformity are directly proportional to the input power and in roughly reverse proportion to the gas pressure in the chamber. Furthermore, the experiments of electromagnetic wave propagation in plasma are conducted in this plasma generator. Blackout phenomena at GPS signal are observed under this system and the measured attenuation curve is of reasonable agreement with the theoretical one, which suggests the effectiveness of the proposed method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic simulations of reverse shear Alfven eigenmodes in DIII-D plasmas

A gyrokinetic ion/mass-less fluid electron hybrid model as implemented in the GEM code [Y. Chen and S. E. Parker, J. Comput. Phys. 220, 837 (2007)] is used to study the reverse shear Alfven eigenmodes (RSAE) observed in DIII-D, discharge no. 142111. This is a well diagnosed case with measurement of the core-localized RSAE mode structures and the mode frequency, which can be used to compare with simulations. Simulations reproduce many features of the observation, including the mode frequency up-sweeping in time and the sweeping range. A new algorithmic feature is added to the GEM code for this study. Instead of the gyrokinetic Poisson equation itself, its time derivative, or the vorticity equation, is solved to obtain the electric potential. This permits a numerical scheme that ensures the E Multiplication-Sign B convection of the equilibrium density profiles of each species cancel each other in the absence of any finite-Larmor-radius effects. These nonlinear simulations generally result in an electron temperature fluctuation level that is comparable to measurements, and a mode frequency spectrum broader than the experimental spectrum. The spectral width from simulations can be reduced if less steep beam density profiles are used, but then the experimental fluctuation level can be reproduced only if a collision rate above the classical level is assumed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of spatially resolved Z-pinch spectra to investigate the nature of 'bright spots'

Localized, intensely radiating regions are often observed in Z pinches. High resolution images of such areas have been recorded at least as far back as the 1970s. However, there is as yet no widely accepted consensus on the nature of these 'bright spots' or how they are formed. This phenomenon has also been referred to 'hot spots' or 'micropinches.' To shed further light on this issue, we have analyzed axially resolved K-shell spectra from 4 Z pinches driven by the refurbished Z generator ('ZR') at Sandia National Laboratories, and the previous version of the Z machine ('Z'). The atomic numbers of the loads varied from 13 to 29. We find that higher spatial K-shell intensity in the Al pinch correlates with density. The K-shell intensity within a copper shot taken on ZR correlates strongly with increased electron temperature, but another, somewhat less well-diagnosed copper shot from Z shows correlation with density. The bright spots in a Ti pinch correlate with neither density nor temperature, but do correlate with the product of density and diameter (proportional to opacity). This opacity correlation is also observed in the other 3 pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact stilbene crystal neutron spectrometer for EAST D-D plasma neutron diagnostics

A new compact stilbene crystal neutron spectrometer has been investigated and applied in the neutron emission spectroscopy on the EAST tokamak. A new components analysis method is presented to study the anisotropic light output in the stilbene crystal detector. A Geant4 code was developed to simulate the neutron responses in the spectrometer. Based on both the optimal light output function and the fitted pulse height resolution function, a reliable neutron response matrix was obtained by Geant4 simulations and validated by 2.5 MeV and 14 MeV neutron measurements at a 4.5 MV Van de Graaff accelerator. The spectrometer was used to diagnose the ion temperature in plasma discharges with lower hybrid wave injection and ion cyclotron resonance heating on the EAST tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of ion beam transport through the 400 Kv ion implanter at Michigan Ion Beam Laboratory

The Michigan Ion Beam Laboratory houses a 400 kV ion implanter. An application that simulates the ion beam trajectories through the implanter from the ion source to the target was developed using the SIMION Registered-Sign code. The goals were to have a tool to develop an intuitive understanding of abstract physics phenomena and diagnose ion trajectories. Using this application, new implanter users of different fields in science quickly understand how the machine works and quickly learn to operate it. In this article we describe the implanter simulation application and compare the parameters of the implanter components obtained from the simulations with the measured ones. The overall agreement between the simulated and measured values of magnetic fields and electric potentials is {approx}10%.

43 PARTICLE ACCELERATORS↗

EBIT spectroscopy of highly charged heavy ions relevant to hot plasmas

We present spectra of highly charged iron, gadolinium, and tungsten ions obtained with electron beam ion traps. Spectroscopic studies of these ions are important to diagnose and control hot plasmas in several areas. For iron ions, the electron density dependence of the line intensity ratio in extreme ultraviolet spectra is investigated for testing the model calculation used in solar corona diagnostics. Soft x-ray spectra of gadolinium are studied to obtain atomic data required in light source development for future lithography. Tungsten is considered to be the main impurity in the ITER plasma, and thus visible and soft x-ray spectra of tungsten have been observed to explore the emission lines useful for the spectroscopic diagnostics of the ITER plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Basis set expansion for inverse problems in plasma diagnostic analysis

A basis set expansion method [V. Dribinski, A. Ossadtchi, V. A. Mandelshtam, and H. Reisler, Rev. Sci. Instrum. 73, 2634 (2002)] is applied to recover physical information about plasma radiation sources from instrument data, which has been forward transformed due to the nature of the measurement technique. This method provides a general approach for inverse problems, and we discuss two specific examples relevant to diagnosing fast z pinches on the 20–25 MA Z machine [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats, J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, J. R. Woodworth, C. W. Mendel, K. R. Prestwich, R. W. Shoup, D. L. Johnson, J. P. Corley, K. C. Hodge, T. C. Wagoner, and P. E. Wakeland, in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, 2007), p. 979]. First, Abel inversion of time-gated, self-emission x-ray images from a wire array implosion is studied. Second, we present an approach for unfolding neutron time-of-flight measurements from a deuterium gas puff z pinch to recover information about emission time history and energy distribution. Through these examples, we discuss how noise in the measured data limits the practical resolution of the inversion, and how the method handles discontinuities in the source function and artifacts in the projected image. We add to the method a propagation of errors calculation for estimating uncertainties in the inverted solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-bandwidth polarimeter for a high density, accelerated spheromak

A three-beam heterodyne polarimeter has been built to diagnose the PI-1 plasma injector at General Fusion, Inc. The polarimeter measures plasma density and Faraday rotation, which can provide estimates of magnetic field magnitude and direction. Two important calibration steps are required for the polarimeter to produce reasonable Faraday rotation signals. Beam polarization ellipticity must be measured to ensure there is a linear Faraday rotation response. In addition, the two beams travelling through the plasma must be collinear to reduce error due to differences in plasma density. Once calibrated, the Faraday rotation signals are in much better agreement with other diagnostics. For a null signal, the Faraday rotation measurement noise floor is 0.1° at 0.5 MHz bandwidth. Comparing preliminary spheromak Faraday rotation measurements to a model, the maximum error is about 0.3° at 0.5 MHz bandwidth, which is primarily due to electrical noise during the injector's capacitor discharge and limitations of the model. At a bandwidth of 0.5 MHz, the polarimeter has an axial resolution between 6 cm and 30 cm depending on the speed of the spheromak, which varies between 30 km/s and 150 km/s. The spheromak length ranges from 0.75 m to 2 m. Additional polarimeter chords will be added in future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗