Feasibility study of a point-of-care positron emission tomography system with interactive imaging capability
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been recommended as a reference design for the proposed Electron-Ion Collider (EIC) program. Here, this paper presents simulation studies of exclusive J/$\psi$ detection and selected physics impact results in EIC using the projected ECCE detector concept. Exclusive quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. Preliminary results estimate the excellent statistics benefited from the large cross section of J/$\psi$ photoproduction and superior performance of ECCE detector concept. The precise measurement of exclusive J/$\psi$ photoproduction at EIC will help us to more deeply understand nuclear gluon distributions, near threshold production mechanism and nucleon mass structure.
The collection of a large number of B hadron decays to hadronic final states at the CDF II detector is possible due to the presence of a trigger that selects events based on track impact parameters. However, the nature of the selection requirements of the trigger introduces a large bias in the observed proper decay time distribution. A lifetime measurement must correct for this bias and the conventional approach has been to use a Monte Carlo simulation. The leading sources of systematic uncertainty in the conventional approach are due to differences between the data and the Monte Carlo simulation. In this paper they present an analytic method for bias correction without using simulation, thereby removing any uncertainty between data and simulation. This method is presented in the form of a measurement of the lifetime of the B{sup -} using the mode B{sup -} {yields} D{sup 0}{pi}{sup -}. The B{sup -} lifetime is measured as {tau}{sub B{sup -}} = 1.663 {+-} 0.023 {+-} 0.015 ps, where the first uncertainty is statistical and the second systematic. This new method results in a smaller systematic uncertainty in comparison to methods that use simulation to correct for the trigger bias.
In the past three years the groups supported by the DOE have all made significant progress and posted major successes. The Minnesota CMS group has played leading roles in five data analyses and has had major roles in detector operations, the data management and the detector upgrades that are planned for for the LHC and those that are planned for the high-luminosity LHC. The CDMS-II experiment held the lead in WIMP sensitivity over the last decade, and is still the most sensitive detector in the world in the low WIMP mass region, with a recent 3σ hint of 8 GeV/c 2 WIMP candidates in the silicon data. SuperCDMS, with three orders of magnitude better electron recoil background rejection, has been collecting data since October 2011. Since all dark matter experiments require a better understanding of neutron backgrounds to make further advances in sensitivity, Cushman has expanded the Minnesota effort on backgrounds to the national level, where she is leading a coordinated effort in neutron simulations for underground physics. The work of Mandic on 100 mm detectors both for Super-CDMS and beyond has advanced rapidly. Also at the Intensity Frontier, the BESIII experiment has had a successful year of operation largely focused on searches for and studies of new "charmonium-like" states above DD threshold. At least one new state has been observed so far, with hints of others. An intensive effort to understand their nature and gain new insight into the strong interaction continues. BESIII has also produced a large number of other results in charmonium decay and light-hadronic physics.
Device for detection of explosives, radioactive and heavily shielded nuclear materials in luggage and cargo containers based on Nanosecond Neutron Analysis/Associated Particles Technique (NNA/APT) is under construction. Detection module consists of a small neutron generator with built-in position-sensitive detector of associated alpha-particles, and several scintillator-based gamma-ray detectors. Explosives and other hazardous chemicals are detected by analyzing secondary high-energy gamma-rays from reactions of fast neutrons with materials inside a container. The same gamma-ray detectors are used to detect unshielded radioactive and nuclear materials. An array of several neutron detectors is used to detect fast neutrons from induced fission of nuclear materials. Coincidence and timing analysis allows one to discriminate between fission neutrons and scattered probing neutrons. Mathematical modeling by MCNP5 and MCNP-PoliMi codes was used to estimate the sensitivity of the device and its optimal configuration. Comparison of the features of three gamma detector types--based on BGO, NaI and LaBr{sub 3} crystals is presented.
The ATLAS inner detector is used to reconstruct secondary vertices due to hadronic interactions of primary collision products, so probing the location and amount of material in the inner region of ATLAS. Data collected in 7 TeV pp collisions at the LHC, with a minimum bias trigger, are used for comparisons with simulated events. The reconstructed secondary vertices have spatial resolutions ranging from ~ 200μm to 1 mm. The overall material description in the simulation is validated to within an experimental uncertainty of about 7%. This will lead to a better understanding of the reconstruction of various objects such as tracks, leptons, jets, and missing transverse momentum.
Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.
Lateral shearing interferometry (LSI) provides a simple means for characterizing the aberrations in optical systems at EUV wavelengths. In LSI, the test wavefront is incident on a low-frequency grating which causes the resulting diffracted orders to interfere on the CCD. Due to its simple experimental setup and high photon efficiency, LSI is an attractive alternative to point diffraction interferometry and other methods that require spatially filtering the wavefront through small pinholes which notoriously suffer from low contrast fringes and improper alignment. In order to demonstrate that LSI can be accurate and robust enough to meet industry standards, analytic models are presented to study the effects of unwanted grating and detector tilt on the system aberrations, and a method for identifying and correcting for these errors in alignment is proposed. The models are subsequently verified by numerical simulation. Finally, an analysis is performed of how errors in the identification and correction of grating and detector misalignment propagate to errors in fringe analysis.
Purpose: The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. Methods: The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 {mu}Gy air KERMA) to the detector. Results: The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r{sup 2} = 0.9999). The dependence was greater than unity (m = 1.101 {+-} 0.006), and the difference from unity was statistically significant (p < 0.005). The SD of mean SNR after calibration also exhibited linear dependence on the SD of the mean SNR before calibration (r{sup 2} = 0.9997). This dependence was less than unity (m = 0.822 {+-} 0.008), and the difference from unity was also statistically significant (p < 0.005). Systems were separated into two groups: systems with a precalibration SNR higher than the median SNR (N = 7), and those with a precalibration SNR lower than the median SNR (N = 7). Posthoc analysis was performed to correct for expanded false positive results. After calibration, the authors noted differences in mean SNR within both high and low groups, but these differences were not statistically significant at the 0.05 level. SNR data from four additional systems and one system from those previously tested after replacement of its detector were compared to the 95% confidence intervals (CI) calculated from the postcalibration SNR data. The comparison indicated that four of these five systems were consistent with the CI derived from the previously tested 14 systems after calibration. Two systems from the paired group that remained outside the CI were studied further. One system was remedied with a grid replacement. The nonconformant behavior of the other system was corrected by replacing the image receptor. Conclusions: Exposure-dependent SNR measurements under conditions simulating thoracic imaging allowed us to develop criteria for digital flat-panel imaging systems from a single manufacturer. These measurements were useful in identifying systems with discrepant performance, including one with a defective grid, one with a defective detector, and one that had not been calibrated for gain and offset. The authors also found that the gain and offset calibration reduces variation in exposure-dependent SNR performance among the systems.
We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.
Purpose: Beam range uncertainty in proton treatment comes primarily from converting the patient's X-ray CT (xCT) dataset to relative stopping power (RSP). Current practices use a single curve for this conversion, produced by a stoichiometric calibration based on tissue composition data for average, healthy, adult humans, but not for the individual in question. Proton radiographs produce water-equivalent path length (WEPL) maps, dependent on the RSP of tissues within the specific patient. This work investigates the use of such WEPL maps to optimize patient-specific calibration curves for reducing beam range uncertainty. Methods: The optimization procedure works on the principle of minimizing the difference between the known WEPL map, obtained from a proton radiograph, and a digitally-reconstructed WEPL map (DRWM) through an RSP dataset, by altering the calibration curve that is used to convert the xCT into an RSP dataset. DRWMs were produced with Plastimatch, an in-house developed software, and an optimization procedure was implemented in Matlab. Tests were made on a range of systems including simulated datasets with computed WEPL maps and phantoms (anthropomorphic and real biological tissue) with WEPL maps measured by single detector proton radiography. Results: For the simulated datasets, the optimizer showed excellent results. It was able to either completely eradicate or significantly reduce the root-mean-square-error (RMSE) in the WEPL for the homogeneous phantoms (to zero for individual materials or from 1.5% to 0.2% for the simultaneous optimization of multiple materials). For the heterogeneous phantom the RMSE was reduced from 1.9% to 0.3%. Conclusion: An optimization procedure has been designed to produce patient-specific calibration curves. Test results on a range of systems with different complexities and sizes have been promising for accurate beam range control in patients. This project was funded equally by the Engineering and Physical Sciences Research Council (UK) and Ion Beam Applications (Louvain-La-Neuve, Belgium)
We present the first observation and cross section measurement of exclusive dijet production in pp interactions, pp{yields}p+dijet+p. Using a data sample of 310 pb{sup -1} collected by the Run II Collider Detector at Fermilab at {radical}(s)=1.96 TeV, exclusive cross sections for events with two jets of transverse energy E{sub T}{sup jet}{>=}10 GeV have been measured as a function of minimum E{sub T}{sup jet}. The exclusive signal is extracted from fits to data distributions based on Monte Carlo simulations of expected dijet signal and background shapes. The simulated background distribution shapes are checked in a study of a largely independent data sample of 200 pb{sup -1} of b-tagged jet events, where exclusive dijet production is expected to be suppressed by the J{sub z}=0 total angular momentum selection rule. Results obtained are compared with theoretical expectations, and implications for exclusive Higgs boson production at the pp Large Hadron Collider at {radical}(s)=14 TeV are discussed.
Purpose: Published methods for image-based material decomposition with multi-energy CT images have required the assumption of volume conservation or accurate knowledge of the x-ray spectra and detector response. The purpose of this work was to develop an image-based material-decomposition algorithm that can overcome these limitations. Methods: An image-based material decomposition algorithm was developed that requires only mass conservation (rather than volume conservation). With this method, using multi-energy CT measurements made with n=4 energy bins, the mass density of each basis material and of the mixture can be determined without knowledge of the tube spectra and detector response. A digital phantom containing 12 samples of mixtures from water, calcium, iron, and iodine was used in the simulation (Siemens DRASIM). The calibration was performed by using pure materials at each energy bin. The accuracy of the technique was evaluated in noise-free and noisy data under the assumption of an ideal photon-counting detector. Results: Basis material densities can be estimated accurately by either theoretic calculation or calibration with known pure materials. The calibration approach requires no prior information about the spectra and detector response. Regression analysis of theoretical values versus estimated values results in excellent agreement for both noise-free and noisy data. For the calibration approach, the R-square values are 0.9960+/−0.0025 and 0.9476+/−0.0363 for noise-free and noisy data, respectively. Conclusion: From multi-energy CT images with n=4 energy bins, the developed image-based material decomposition method accurately estimated 4 basis material density (3 without k-edge and 1 with in the range of the simulated energy bins) even without any prior information about spectra and detector response. This method is applicable to mixtures of solutions and dissolvable materials, where volume conservation assumptions do not apply. CHM receives research support from NIH and Siemens Healthcare.
We present results from an all-sky search for unmodeled gravitational-wave bursts in the data collected by the LIGO, GEO 600 and Virgo detectors between November 2006 and October 2007. The search is performed by three different analysis algorithms over the frequency band 50-6000 Hz. Data are analyzed for times with at least two of the four LIGO-Virgo detectors in coincident operation, with a total live time of 266 days. No events produced by the search algorithms survive the selection cuts. We set a frequentist upper limit on the rate of gravitational-wave bursts impinging on our network of detectors. When combined with the previous LIGO search of the data collected between November 2005 and November 2006, the upper limit on the rate of detectable gravitational-wave bursts in the 64-2048 Hz band is 2.0 events per year at 90% confidence. We also present event rate versus strength exclusion plots for several types of plausible burst waveforms. The sensitivity of the combined search is expressed in terms of the root-sum-squared strain amplitude for a variety of simulated waveforms and lies in the range 6x10{sup -22} Hz{sup -1/2} to 2x10{sup -20} Hz{sup -1/2}. This is the first untriggered burst search to use data from the LIGO and Virgo detectors together, and the most sensitive untriggered burst search performed so far.
For accelerator neutrino experiments, an accurate prediction of the incoming neutrino flux is crucial for reducing uncertainties for all physics measurements. In this exciting period for the Short-Baseline Neutrino program at Fermilab, with far detector (ICARUS) already operating and the near detector (SBND) nearing operation, an updated flux model for the Booster Neutrino Beam (BNB) is presented. The BNB delivers 8 GeV protons to a beryllium target, subsequently producing neutrinos from the decay of the secondary beam of hadrons. A updated Monte-Carlo simulation of beam production in GEANT4 has been created, allowing predictions to be made for detectors with different baselines, offsets and sizes. This new simulation contains new features, such as a full neutrino ancestry to handle hadron production systematics with more precision, with a view to storing all resulting particles - including neutral mesons - from the proton-Beryllium scatter to allow the study of exotic BSM scenarios. Results are presented, with comparisons to the original flux simulated for the MiniBooNE experiment.
We study the bunch field diffusion and energy dissipation in the beam pipe of the Super-B detector, which consists of two coaxial Be thin pipes (half a millimeter). Cooling water will run between these two pipes. Gold and nickel will be sputtered (several microns) onto the beryllium pipe at different sides. The Maxwell equations for the beam fields in these thin layers are solved numerically for the case of infinite pipes. We also calculate the amplitude of the electromagnetic fields outside the beam pipe, which may be noticeable as the beam current can reach 4 A in each beam. Results of simulations are used for the design of this central part of the Super-B detector.
In the past few years, the Consortium for Advanced Simulation of Light Water Reactors (CASL) has overseen a successful activity to extend the radiation transport capability from the reactor in-core geometry to the ex-core geometry by coupling the deterministic neutronics code MPACT, with the Monte Carlo code Shift. However, transient problems such as RIAs require an efficient prediction of the ex-core detector response to determine the timeframe for a reactor trip. Therefore, in addition to the high-fidelity MPACT-Shift coupled calculation, separate efforts have been made to explore simplified methods for ex-core detector response with MPACT standalone calculation. In a previous milestone L3_RTM.MCH.P17.06, several simplified methods for ex-core detector response were developed in MPACT. In particular, the double kernel method is based on the default MPACT core geometry, so extensive modeling or transport calculation with full reflector and ex-core details are not needed in this method. Since the 1-D diffusion and neutron streaming kernels are used for extended ex-core calculations, the extra computational efforts are very small. The work implemented in the current milestone provides a fully integrated option for MPACT to approximately calculate the ex-core detector response using the double kernel method. To overcome the difficulty of obtaining the consistent diffusion coefficients (these were obtained through separate CMFD calculation and edits), the 1-D diffusion solver is replaced by a 1-D Sn transport solver to compute the neutron flux at the vessel outer surface. The new VERA inputs for ex-core detector are processed in MPACT. The detector signals are linked to the SCRAM logic as an option to trip the core during transient calculation. Two sets of 3-D quarter core problems are run with MPACT standalone and VeraShift to verify the radial and axial effects on detector response by varying the moderator density and control rod position. For the cases with moderator density changes, the detector responses from MPACT are within 2 sigma error of VeraShift. For the cases at different control rod positions, the axial offsets computed from MPACT are within 2% error of VeraShift results.