Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Two-Stage Reinforcement Learning Policy Search for Grid-Interactive Building Control

This paper develops an intelligent grid-interactive building controller, which optimizes building operation during both normal hours and demand response (DR) events. To avoid costly on-demand computation and to adapt to non-linear building models, the controller utilizes reinforcement learning (RL) and makes real-time decisions based on a near-optimal control policy. Learning such a policy typically amounts to solving a hard non-convex optimization problem. We propose to address this problem with a novel global-local policy search method. In the first stage, an RL algorithm based on zero-order gradient estimation is leveraged to search for the optimal policy globally, due to its scalability and the potential to escape some poor performing local optima. The obtained policy is then fine-tuned locally to bring the first-stage solution closer to that of the original unsmoothed problem. Experiments on a simulated five-zone commercial building demonstrate the advantages of the proposed method over existing learning approaches. They also show that the learned control policy outperforms a pragmatic linear model predictive controller (MPC) and approaches the performance of an oracle MPC in testing scenarios. Using a state-of-the-art advanced computing system, we demonstrate that the controller can be learned and deployed within hours of training.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anoxia begets anoxia: A positive feedback to the deoxygenation of temperate lakes

Abstract Declining oxygen concentrations in the deep waters of lakes worldwide pose a pressing environmental and societal challenge. Existing theory suggests that low deep‐water dissolved oxygen (DO) concentrations could trigger a positive feedback through which anoxia (i.e., very low DO) during a given summer begets increasingly severe occurrences of anoxia in following summers. Specifically, anoxic conditions can promote nutrient release from sediments, thereby stimulating phytoplankton growth, and subsequent phytoplankton decomposition can fuel heterotrophic respiration, resulting in increased spatial extent and duration of anoxia. However, while the individual relationships in this feedback are well established, to our knowledge, there has not been a systematic analysis within or across lakes that simultaneously demonstrates all of the mechanisms necessary to produce a positive feedback that reinforces anoxia. Here, we compiled data from 656 widespread temperate lakes and reservoirs to analyze the proposed anoxia begets anoxia feedback. Lakes in the dataset span a broad range of surface area (1–126,909 ha), maximum depth (6–370 m), and morphometry, with a median time‐series duration of 30 years at each lake. Using linear mixed models, we found support for each of the positive feedback relationships between anoxia, phosphorus concentrations, chlorophyll a concentrations, and oxygen demand across the 656‐lake dataset. Likewise, we found further support for these relationships by analyzing time‐series data from individual lakes. Our results indicate that the strength of these feedback relationships may vary with lake‐specific characteristics: For example, we found that surface phosphorus concentrations were more positively associated with chlorophyll a in high‐phosphorus lakes, and oxygen demand had a stronger influence on the extent of anoxia in deep lakes. Taken together, these results support the existence of a positive feedback that could magnify the effects of climate change and other anthropogenic pressures driving the development of anoxia in lakes around the world.

54 ENVIRONMENTAL SCIENCES↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EQSIM—A multidisciplinary framework for fault-to-structure earthquake simulations on exascale computers, part II: Regional simulations of building response

The existing observational database of the regional-scale distribution of strong ground motions and measured building response for major earthquakes continues to be quite sparse. As a result, details of the regional variability and spatial distribution of ground motions, and the corresponding distribution of risk to buildings and other infrastructure, are not comprehensively understood. Utilizing high-performance computing platforms, emerging high-resolution, physics-based ground motion simulations can now resolve frequencies of engineering interest and provide detailed synthetic ground motions at high spatial density. This provides an opportunity for new insight into the distribution of infrastructure seismic demands and risk. In the work presented herein, the EQSIM fault-to-structure computational framework described in a companion paper, McCallen et al., is employed to investigate the regional-scale response of buildings to large earthquakes. A representative M = 7.0 strike-slip event is used to explore the distribution and amplitude of building demand, and comparisons are made between building response computed with fault-to-structure simulations and building response computed with existing measured near-fault earthquake records. New information on the distribution and variability of building response from high-performance parallel simulations is described and analyzed, and favorable first comparisons between building response predicted with both fault-to-structure simulations and real ground motions records are presented.

58 GEOSCIENCES↗

Pilgrim Hot Springs: GEOPHIRES Inputs and Outputs for Direct-Use Geothermal District Heating and Cooling

This dataset includes files for a techno-economic analysis conducted using the GEOPHIRES simulator to examine the feasibility of expanding a larger district heating site in a remote location: Pilgrim Hot Springs, Alaska. Files included here are GEOPHIRES inputs and outputs for five different scenarios with varying demand, cycle, and system design characteristics to analyze. Also included is the link to the GEOPHIRES GitHub, as well as a link to the dataset that contains the energy modelling used to determine the heating demand for the district. For a list of the differences between scenarios, see the included "Input Overview.txt" file. Fields included in the input files are: subsurface technical parameters, surface technical parameters, financial parameters, capital and O&M parameters, as well as simulation parameters. The output files are case reports that summarize all equipment, reservoir characteristics, costs, and heating profiles.

15 GEOTHERMAL ENERGY↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

End-Use Load Profiles for the U.S. Building Stock: Methodology and Results of Model Calibration, Validation, and Uncertainty Quantification

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High- quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation (Frick, Eckman, and Goldman 2017; Frick 2019). To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project - End-Use Load Profiles for the U.S. Building Stock - that culminated in the release of a publicly available dataset1 of simulated EULPs representing residential and commercial buildings across the contiguous United States. The motivation for this work is further detailed in a November 2019 report: Market Needs, Use Cases, and Data Gaps (Mims Frick et al. 2019). This Methodology and Results report provides detailed descriptions of how the dataset was developed, intended for an audience of dataset and model users interested in the technical details. These details include descriptions of all of the model improvements made for calibration and the final comparisons to empirical data sources. A companion report, End-Use Load Profiles for the U.S. Building Stock: Applications and Opportunities, will be published subsequently and will describe example applications and considerations for using the dataset, intended for an audience of general dataset users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Forecasting Distributed PV Adoption in Barranquilla, Colombia [Slides]

The objective of the dGen Colombia project is to provide projections to 2050 on distributed PV deployment by sector for a range of scenarios for Barranquilla, Colombia. NREL used the open-source Distributed Generation Market Demand Model (dGen) adapted for international projects for this analysis. As part of this analysis, technical potential, economic potential, and adoption projections of rooftop and groundmount PV for the city of Barranquilla are presented. Five main scenarios and their combinations were modeled to provide insight on the impact of increased demand from electric vehicles, air conditioning, and time-of-use tariffs.

14 SOLAR ENERGY↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bid-in Price-Sensitive Load: A Comparison with Fixed Load in a Realistic Test System

Bulk power systems operations, in both simulation and practice, are often built on the principle of minimizing production costs, which assumes to first order that demand is fixed and that the only degrees of freedom for balancing generation and load are supply-side unit commitment and dispatch decisions. The purpose of this report is to interrogate the value of welfare-maximizing markets that not only physically balance demand and supply but also ensure that market outcomes provide consumer value by directly maximizing welfare, defined as the value of consumption minus production costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗