At least 1,603 records · Page 89

ADNDT's enduring distinct role in the scientific publishing ecosystem

September 2024 marks an important anniversary for Atomic Data and Nuclear Data Tables – the 55th year since the inaugural edition in September 1969 – and prompts noting the enduring distinct service the journal has delivered, and continues to deliver, to the scientific community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metal Organic Frameworks for Noble Gas Isotope Harvesting at FRIB (Final Technical Report)

This project was a collaborative effort between Lawrence Livermore National Laboratory (LLNL) and Michigan State University (MSU) to investigate the use of promising metal organic frameworks (MOFs) for radioactive noble gas capture, with a focus on harvesting exotic radiokryptons from FRIB. After screening several candidate materials, two MOFs were selected for testing: SIFSIX-3Cu and SBMOF-1. Further evaluation showed that although SIFSIX-3Cu has a high selectivity for Kr, SBMOF-1 is less sensitive to the humidity that is present in the FRIB harvesting system and is more readily integrated into the harvesting infrastructure. SBMOF-1 was then evaluated for temperature-dependent Kr and Xe uptake in order to determine the sorption enthalpy. The SBMOF-1 data led to the design of a noble gas capture system that will be fabricated and put into service for isotope harvesting at FRIB as part of a separate project.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kalispel Resident Fish Project : Annual Report, 2008.

In 2008, the Kalispel Natural Resource Department (KNRD) continued to implement its habitat enhancement projects for bull trout (Salvelinus confluentus) and westslope cutthroat trout (Oncorhynchus clarki lewisi). Baseline fish population and habitat assessments were conducted in Upper West Branch Priest River. Additional fish and habitat data were collected for the Granite Creek Watershed Assessment, a cooperative project between KNRD and the U.S. Forest Service Panhandle National Forest (FS) . The watershed assessment, funded primarily by the Salmon Recovery Funding Board of the State of Washington, will be completed in 2009.

13 HYDRO ENERGY↗

DNA Methylation Patterns of Chronic Explosive Breaching in U.S. Military Warfighters

Background: Injuries from exposure to explosions rose dramatically during the Iraq and Afghanistan wars, which motivated investigation of blast-related neurotrauma. We have undertaken human studies involving military “breachers” —exposed to controlled, low-level blast during a 3-days explosive breaching course. Methods: We screened epigenetic profiles in peripheral blood samples from 59 subjects (in two separate U.S. Military training sessions) using Infinium MethylationEPIC BeadChips. Participants had varying numbers of exposures to blast over their military careers (empirically defined as high ≥ 40, and conversely, low < 39 breaching exposures). Daily self-reported physiological symptoms were recorded. Tinnitus, memory problems, headaches, and sleep disturbances are most frequently reported. Results: We identified 14 significantly differentially methylated regions (DMRs) within genes associated with cumulative blast exposure in participants with high relative to low cumulative blast exposure. Notably, NTSR1 and SPON1 were significantly differentially methylated in high relative to low blast exposed groups, suggesting that sleep dysregulation may be altered in response to chronic cumulative blast exposure. In comparing lifetime blast exposure at baseline (prior to exposure in current training), and top associated symptoms, we identified significant DMRs associated with tinnitus, sleep difficulties, and headache. Notably, we identified KCNN3, SOD3, MUC4, GALR1, and WDR45B, which are implicated in auditory function, as differentially methylated associated with self-reported tinnitus. These findings suggest neurobiological mechanisms behind auditory injuries in our military warfighters and are particularly relevant given tinnitus is not only a primary disability among veterans, but has also been demonstrated in active duty medical records for populations exposed to blast in training. Additionally, we found that differentially methylated regions associated with the genes CCDC68 and COMT track with sleep difficulties, and those within FMOD and TNXB track with pain and headache. Conclusion: Sleep disturbances, as well as tinnitus and chronic pain, are widely reported in U.S. military service members and veterans. As we have previously demonstrated, DNA methylation encapsulates lifetime exposure to blast. The current data support previous findings and recapitulate transcriptional regulatory alterations in genes involved in sleep, auditory function, and pain. These data uncovered novel epigenetic and transcriptional regulatory mechanism underlying the etiological basis of these symptoms.

60 APPLIED LIFE SCIENCES↗

System Retrofits in Efficiency Programs: Track Record and Outlook

Commercial building retrofits are often limited to simple upgrades of individual building components such as equipment or lamp replacements. These equipment- or component-level retrofits have been shown to have less potential for whole building energy savings (50% less in studied cases) compared to comprehensive system-based approaches. System retrofits with their potential for much greater savings are critical to achieving aggressive energy reduction goals in the existing building stock but to date there has been little deep analysis of the track record and trends for systems retrofits in commercial buildings. This paper addresses several questions: 1. To what extent are systems retrofits taking place in the building retrofit marketplace today? 2. Do current systems retrofits in fact save more energy than component retrofits? 3. What kinds of efficiency measures are currently most prevalent in system retrofits? 4. Does systems adoption vary across different retrofit programmatic approaches (e.g. utility incentive programs, federal retrofit programs, ESCOs)? Findings, based on an analysis of retrofit data from 12,000 projects across the U.S. from custom utility incentive programs, federal retrofit programs, and Energy Service Companies (ESCOs), indicate the state of the current market with respect to adoption of systems technologies. A wide range of stakeholders were also interviewed to define the challenges and opportunities for greater deployment. A range of barriers is presented including technical and structural (i.e. programmatic, policy), along with recommendations to accelerate deployment of these strategic approaches.

Regnier, Cynthia↗

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Agent-based simulations of shared automated vehicle operations: reflecting travel-party size, season and day-of-week demand variations

Here, this paper explores the effects of day of week and season of year demand variations for shared rides, along with realistic travel party sizes, on shared autonomous vehicle (SAV) services across the Austin, Texas region. Using the agent-based POLARIS program, synthetic person-trips that reflect travel-party size (from one to four persons) and demand variations over days and months, as evident in the National Household Travel Survey data were simulated in each scenario over a 24 h travel day. Results show that realistic party sizes can bring considerable changes to SAV fleet performance, including up to 8.5% higher service rates (number of requests accepted within 15 min), 5 min shorter journey times (wait time + travel time), 28% higher vehicle occupancies on weekends, and roughly 4% lower empty fleet VMT. Weekend travel is most impacted by season of year, with weekday travel patterns looking more uniform (thanks to work and school trips). Various performance metrics for the Austin network, like total and empty VMT, change by up to 30% when considering realistic variations in party size and time of year. This paper underscores the value of recognizing day-to-day and month-to-month variations in travel demand, and the importance of agent-based model equations to reflect travel-party size. Such realism can help quantify SAV seat occupancies more accurately, highlighting the importance of shared mobility. However, it also creates demand and supply issues for operators that now need more information on party size to manage dynamic ride-sharing, or those that may wish to shift their fleet vehicles to other regions for special events to protect profits while offering reasonable wait times to customers throughout the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FIRE: A Failure-Adaptive RL Framework for Edge Computing Migrations

In edge computing, users' service profiles are migrated between edge servers due to user mobility. Reinforcement Learning (RL) frameworks have been proposed to do so, often trained on simulated data. However, existing RL frameworks overlook occasional server failures, which although rare, impact latency-sensitive applications like AR/VR and real- time obstacle detection. These rare failures, being not adequately represented in historical training data, pose a challenge for data-driven RL algorithms. We introduce FIRE, a framework that adapts to rare events by training a RL policy in an edge computing digital twin environment. We propose FIRE-ImRE, an importance sampling-based Q-learning algorithm, which samples rare events proportionally to their impact on the value function. FIRE considers delay, migration, failure, and backup placement costs across individual and shared service profiles. We prove FIRE-ImRE's boundedness and convergence to optimality. Next, we introduce novel deep Q-learning (FIRE-ImDQL) and actor critic (FIRE-ImACRE) versions of our algorithm to enhance scalability. Here, we extend our framework to accommodate users with varying risk tolerances of rare failure events. Through trace-driven experiments, we show that FIRE reduces edge computing costs compared to vanilla RL and the greedy baseline in the event of failures.

Edge computing↗

Calculating uncertainty on K-effective with MONK10 - 14583

Criticality safety assessments require a demonstration that a particular configuration of fissile material has an adequate sub-critical margin (k-effective sufficiently below unity) to ensure that the risk of criticality under normal operation and accident conditions is acceptable. The required sub-critical margin depends upon the uncertainty in the estimated value of k-effective. The uncertainty in the calculated value of k-effective arises from a number of sources, including: manufacturing tolerances on input data to the code (affecting geometry, compositions and densities), uncertainty in the nuclear data used by the code, stochastic uncertainty resulting from Monte Carlo simulation and modelling approximations/errors, including the inevitable bugs in the software. The ANSWERS Software Service, in collaboration with industrial partners, is developing a number of techniques to better understand and quantify uncertainty on predicted values of k-effective, using MONK. The SPRUCE utility code has been developed to allow uncertainty to be estimated using sampling methods. This can include the sampling of input parameters (including dimensions, compositions and densities) from statistical distributions. It can also include sampling different nuclear data libraries. A set of nuclear data libraries has been generated for this purpose by sampling from statistical distributions that represent the uncertainties in the published nuclear data evaluated files; a set of libraries has been produced for Latin Hypercube Sampling. By varying the input data and nuclear data, separate and combined uncertainties due to manufacturing tolerances and nuclear data can be derived. By performing least squares fitting on the results it is also possible to estimate the contribution of each of the uncertain inputs and a sensitivity method in MONK can break down the nuclear data uncertainty. (authors)

42 ENGINEERING↗

Market Implications of Alternative Operating Reserve Modeling in Wholesale Electricity Markets

Pricing and settlement mechanisms are crucial for efficient resource allocation, investment incentives, market competition, and regulatory oversight. In the United States, Regional Transmission Operators (RTOs) adopts a uniform pricing scheme that hinges on the marginal costs of supplying additional electricity. This study investigates the pricing and settlement impacts of alternative reserve constraint modeling, highlighting how even slight variations in the modeling of constraints can drastically alter market clearing prices, reserve quantities, and revenue outcomes. Focusing on the diverse market designs and assumptions in ancillary services by U.S. RTOs, particularly in relation to capacity sharing and reserve substitutions, the research examines four distinct models that combine these elements based on a large-scale synthetic power system test data. Our study provides a critical insight into the economic implications and the underlying factors of these alternative reserve constraints through market simulations and data analysis.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In-service Inspection of Radioactive Waste Tanks at the Savannah River Site – 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-service inspection of radioactive waste tanks at the Savannah River Site - 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The roles of learning mechanisms in services: Evidence from US residential solar installations

Non-hardware costs are majority of the cost of producing solar photovoltaic (PV) electricity. Here we use matched data on patents and over 125,000 residential PV installations to estimate the effects of three learning mechanisms in reducing PV costs: learning by doing, searching, and interacting. While previous work in this area has focused predominantly on learning by doing, we find that learning by searching and interacting are also significant mechanisms to facilitate non-hardware cost reductions. Including these two mechanisms reduces the effect of learning by doing in explaining non-hardware cost reductions by 43%. Our results suggest that prior work may overemphasize the role of learning by doing and the policies that help generate learning by doing. Analysis of the supplier-network between installers and their suppliers shows that concentrated supplier networks are associated with lower non-hardware costs, although there are key differences between installer-panel and installer-inverter manufacturer networks. An important implication is that policies for reducing non-hardware costs need to take a more complete view of how different learning mechanisms engender cost reductions. They should particularly consider the important role of learning in supplier networks in cost reductions—an effect that until now has largely been missing in analyses of solar non-hardware costs.

14 SOLAR ENERGY↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation and the results have proved the effectiveness of this method.

AMI↗

Digitalization, Management and Synthesis of Thermal Hydraulic Legacy Data Using Dynamical System Scaling

A unique attribute of the nuclear industry is the extent by which designers, developers, operators, and regulators pay attention to demonstrating the safety case. The safety case for nuclear systems is a written, traceable expression of safety, demonstrating the system’s protective measures against uncontrolled radiological releases. The nuclear installation resiliency or safety takes overriding priority over function and performance. The preparation of the safety case heavily relies on extensive experimental campaigns that challenge the target design under a spectrum of postulated accident scenarios. For safety reasons, these experiments are typically conducted in sub-scale test apparatuses intended to reproduce the postulated accident scenarios and event sequences realistically but subject to proven similarity criteria, often referred to as scaling analyses. Since the dawn of the nuclear industry, significant resources have been committed to the construction and operation of such test facilities and a massive amount of data has been generated. Such test data have been and are still used to validate the fundamental assumptions of nuclear power plant phenomena. As we move into the digital world, capturing this multi-decades worth of information in a transparent, easily accessible, and usable manner for the public and industry stakeholders is of paramount importance. Over the last few years FPoliSolutions has been actively developing an enterprise digital data ontology platform (FPoliDON) intended to do just that. The concept was introduced in a paper at the previous NURETH edition and has been significantly enhanced since. With the vision of helping designers use the data to assess their safety case evaluation models, the platform was designed not only to ontologically organize the experimental data, but also to guide the user in the complex analytics associated with the interpretation and use of such test results. A new feature which has been recently added is the ability for the user to access a library of sophisticated mathematical procedures for performing scaling analyses. For this purpose, the Dynamical System Scaling (DSS) procedure invented by Dr. Jose’ Reyes was formulated as one of the services in the digital platform. These methods have been demonstrated to provide an excelled mathematical apparatus to identify similarity criteria or quantify distortions between measured data and the target prototypical conditions. Moreover, DSS can provide a level of synthesis across SETs and IETs which has the promise to yield efficiency in the evaluation code assessment activities. This is often a daunting and expensive task to set up evaluation models that support the safety case of current and future nuclear power plants.

Reyes, Jose↗

Aging Management of Nuclear Power Plant Concrete Structures - Overview and Suggested Research Topics

Nuclear power plant concrete structures are described and their operating experience noted. Primary considerations related to management of their aging are noted and an indication of their status provided: degradation mechanisms, damage models, and material performance; assessment and remediation (i.e., component selection, in-service inspection, nondestructive examinations, and remedial actions); and estimation of performance at present or some future point in time (i.e., application of structural reliability theory to the design and optimization of in-service inspection/maintenance strategies, and determination of the effects of degradation on plant risk). Several activities are identified that provide background information and data on areas of concern with respect to nondestructive examination of nuclear power plant concrete structures: inspection of thick-walled, heavily-reinforced sections, basemats, and inaccessible areas of the containment metallic pressure boundary. Topics are noted where additional research would be of benefit to aging management of nuclear power plant concrete structures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Generalized Framework for Modeling Next Generation 911 Implementations

This document summarizes the current state of Sandia 911 modeling capabilities and then addresses key aspects of Next Generation 911 (NG911) architectures for expansion of existing models. Analysis of three NG911 implementations was used to inform heuristics ,associated key data requirements, and assumptions needed to capture NG911 architectures in the existing models. Modeling of NG911 necessitates careful consideration of its complexity and the diversity of implementations. Draft heuristics for constructing NG911 models are pres ented based on the analysis along with a summary of current challenges and ways to improve future NG911 modeling efforts. We found that NG911 relies on E nhanced 911 (E911) assets such as 911 selective routers to route calls originating from traditional tel ephony service which are a majority of 911 calls. We also found that the diversity and transitional nature of NG911 implementations necessitates significant and frequent data collection to ensure that adequate model s are available for crisis action support.