Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection

Purpose: Our purpose was to reduce image noise in spectral CT by exploiting data redundancies in the energy domain to allow flexible selection of the number, width, and location of the energy bins. Methods: Using a variety of spectral CT imaging methods, conventional filtered backprojection (FBP) reconstructions were performed and resulting images were compared to those processed using a Local HighlY constrained backPRojection Reconstruction (HYPR-LR) algorithm. The mean and standard deviation of CT numbers were measured within regions of interest (ROIs), and results were compared between FBP and HYPR-LR. For these comparisons, the following spectral CT imaging methods were used:(i) numerical simulations based on a photon-counting, detector-based CT system, (ii) a photon-counting, detector-based micro CT system using rubidium and potassium chloride solutions, (iii) a commercial CT system equipped with integrating detectors utilizing tube potentials of 80, 100, 120, and 140 kV, and (iv) a clinical dual-energy CT examination. The effects of tube energy and energy bin width were evaluated appropriate to each CT system. Results: The mean CT number in each ROI was unchanged between FBP and HYPR-LR images for each of the spectral CT imaging scenarios, irrespective of bin width or tube potential. However, image noise, as represented by the standard deviation of CT numbers in each ROI, was reduced by 36%-76%. In all scenarios, image noise after HYPR-LR algorithm was similar to that of composite images, which used all available photons. No difference in spatial resolution was observed between HYPR-LR processing and FBP. Dual energy patient data processed using HYPR-LR demonstrated reduced noise in the individual, low- and high-energy images, as well as in the material-specific basis images. Conclusions: Noise reduction can be accomplished for spectral CT by exploiting data redundancies in the energy domain. HYPR-LR is a robust method for reducing image noise in a variety of spectral CT imaging systems without losing spatial resolution or CT number accuracy. This method improves the flexibility to select energy bins in the manner that optimizes material identification and separation without paying the penalty of increased image noise or its corollary, increased patient dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Demonstration of Ion Beam Cooling with Pulsed Electron Beam

Cooling ion beams at high energy is presently considered for several ion colliders, in order to achieve high luminosities by enabling a significant reduction of emittance of hadron beams. Electron beam at cooling channel in a few to tens MeV can be accelerated by a RF/SRF linac, and thus using bunched electrons to cool bunched ions. To study such cooling process, the DC electron gun of EC35 cooler at the storage ring CSRm, IMP was modified by pulsing the grid voltage. A 0.07-3.5 micro-second pulse length with a repetition frequency of less than 250 kHz and synchronized with the ion revolution frequency was obtained. The first experimental demonstration of cooling of a coasting and bunched ion beam by a pulsed electron beam was carried out. Data analysis indicates the bunch length shrinkage and the momentum spread reduction of bunched 12C+6 ion beam as evidence of cooling. A longitudinal grouping effect of the coasting ion beam by the electron pulses has also been observed*. In this paper, we will present experimental results and comparison to the simulation modelling, particularly on the bunched electron cooling data after carefully analyzing the beam diagnostic signals.

Zhang, Yuhong↗

Analysis and Benchmarking of feature reduction for classification under computational constraints

Abstract Machine learning is most often expensive in terms of computational and memory costs due to training with large volumes of data. Current computational limitations of many computing systems motivate us to investigate practical approaches, such as feature selection and reduction, to reduce the time and memory costs while not sacrificing the accuracy of classification algorithms. In this work, we carefully review, analyze, and identify the feature reduction methods that have low costs/overheads in terms of time and memory. Then, we evaluate the identified reduction methods in terms of their impact on the accuracy, precision, time, and memory costs of traditional classification algorithms. Specifically, we focus on the least resource intensive feature reduction methods that are available in Scikit-Learn library. Since our goal is to identify the best performing low-cost reduction methods, we do not consider complex expensive reduction algorithms in this study. In our evaluation, we find that at quadratic-scale feature reduction, the classification algorithms achieve the best trade-off among competitive performance metrics. Results show that the overall training times are reduced 61%, the model sizes are reduced 6×, and accuracy scores increase 25% compared to the baselines on average with quadratic scale reduction.

97 MATHEMATICS AND COMPUTING↗

Modeling the climate impacts of deploying solar reflective cool pavements in California cities

Solar reflective “cool pavements” have been proposed as a potential heat mitigation strategy for cities. However, previous research has not systematically investigated the extent to which cool pavements could reduce urban temperatures. In this study we investigated the climate impacts of widespread deployment of cool pavements in California cities. Using the Weather Research and Forecasting model, we simulated the current climate of California at 4 km spatial resolution. Comparing this simulation to 105 weather stations in California suggested an overall mean bias (model minus observation) of -0.30°C. Widespread pavement albedo increases of 0.1 and 0.4 in California cities were then simulated. Comparing temperature reductions for each scenario showed that the climate response to pavement albedo modification was nearly linear. Temperature reductions at 14:00 local standard time were found to be 0.32°C per 0.1 increase in grid cell average albedo. Temperature reductions were found to peak in the late morning and evening when (a) boundary layer heights were low and (b) solar irradiance (late morning) and heat accumulation in the pavement (evening) was high. Temperature reductions in summer were found to exceed those in winter, as expected. After scaling the results using realistic data-derived urban canyon morphologies and an off-line urban canyon albedo model, annual average surface air temperature reductions from increasing pavement albedo by 0.4 ranged from 0.18°C (Palm Springs) to 0.86°C (San Jose). We note the variation among cities was due to differences in baseline climate, size of the city, urban fraction, and urban morphology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coalescing at 8 GeV in the Fermilab Main Injector

For Project X, it is planned to inject a beam of 3 10{sup 11} particles per bunch into the Main Injector. To prepare for this by studying the effects of higher intensity bunches in the Main Injector it is necessary to perform coalescing at 8 GeV. The results of a series of experiments and simulations of 8 GeV coalescing are presented. To increase the coalescing efficiency adiabatic reduction of the 53 MHz RF is required. This results in {approx}70% coalescing efficiency of 5 initial bunches. Data using wall current monitors has been taken to compare previous work and new simulations for 53 MHz RF reduction, bunch rotations and coalescing, good agreement between experiment and simulation was found. By increasing the number of bunches to 7 and compressing the bunch energy spread a scheme generating approximately 3 10{sup 11} particles in a bunch has been achieved. These bunches will then be used in further investigations.

43 PARTICLE ACCELERATORS↗

THE PAN-STARRS 1 PHOTOMETRIC REFERENCE LADDER, RELEASE 12.01

As of 2012 January 21, the Pan-STARRS 1 3{pi} Survey has observed the 3/4 of the sky visible from Hawaii with a minimum of 2 and mean of 7.6 observations in five filters, g {sub P1}, r {sub P1}, i {sub P1}, z {sub P1}, y {sub P1}. Now at the end of the second year of the mission, we are in a position to make an initial public release of a portion of this unprecedented data set. This article describes the PS1 Photometric Ladder, Release 12.01. This is the first of a series of data releases to be generated as the survey coverage increases and the data analysis improves. The Photometric Ladder has rungs every hour in right ascension and at four intervals in declination. We will release updates with increased area coverage (more rungs) from the latest data set until the PS1 survey and the final re-reduction are completed. The currently released catalog presents photometry of {approx}1000 objects per square degree in the rungs of the ladder. Saturation occurs at g {sub P1}, r {sub P1}, i {sub P1} {approx} 13.5; z {sub P1} {approx} 13.0; and y {sub P1} {approx} 12.0. Photometry is provided for stars down to g {sub P1}, r {sub P1}, i {sub P1} {approx} 19.1 in the AB system. This data release depends on the rigid 'Ubercal' photometric calibration using only the photometric nights, with systematic uncertainties of (8.0, 7.0, 9.0, 10.7, 12.4) mmag in (g {sub P1}, r {sub P1}, i {sub P1}, z {sub P1}, y {sub P1}). Areas covered only with lower quality nights are also included, and have been tied to the Ubercal solution via relative photometry; photometric accuracy of the non-photometric regions is lower and should be used with caution.

79 ASTRONOMY AND ASTROPHYSICS↗

2018 Meander C floodplain groundwater chemistry from the East River Watershed, Colorado

This dataset includes groundwater geochemistry data from floodplain piezometers collected as a part of the Watershed Function Scientific Focus Area (SFA) located in the Upper Colorado River Basin. The data were collected in order to investigate the role of hyporheic exchange and other river corridor processes on riverine export of solutes. Floodplain piezometers installed along two transects across Meander C in the Pumphouse vicinity (MCP and MCB wells) were sampled on daily to weekly time scales during summer-fall 2018. Some river water grab samples are also included. Data includes in-field measurements (pH, electrical conductivity [EC], oxidation reduction potential [ORP], dissolved oxygen [DO], Fe(II), and groundwater level) along with laboratory measurements (dissolved inorganic carbon [DIC], dissolved organic carbon [DOC], metals and major cations, anions [chloride, sulfate, nitrate], and dissolved ammonium). Five files are included in this dataset, including: sample locations and depths in both a kmz file which can be opened in Google Earth and a csv file, sampling protocol as a pdf document, aqueous geochemistry data in a csv file, and analytical detection limits in a csv file.

54 ENVIRONMENTAL SCIENCES↗

Accurate Prediction of Algal Biomass Lipid, Protein, and Carbohydrate Composition with Machine Learning Regression Modelling of Near-IR Spectra

During large scale algal biomass cultivation, it is difficult to reliably control relative composition to target levels. Rapid determination of chemical composition is feasible by using near infrared (NIR) spectral data. We sought to build and improve on reliable high-throughput screening prediction method based on partial least squares regression (PLSR) by the application of artificial neural networks (ANN) and associated optimization strategies. The algal biomass sample set was designed and created in an iterative process of culturing in physiologically diverse conditions at the GAI field site, followed by compositional analyses at NREL. The workflow allowed us to identify gaps in compositional space for informing the subsequent cultivation and sampling efforts and generated a high quality set of 210 unique samples with chemical analysis results, spectral scanning data, and cultivation metadata. We observed a significant improvement in the performance of carbohydrate content predictions using an optimized ANN model compared to PLSR, with > 16% reduction in mean absolute percent error (MAPE) when tested on the same set of reserved data. The optimized ANN models for FAME and protein prediction performed exceptionally well with 5.99% and 5.09% MAPE, respectively. Application of these methods to detection and quantification of minor biomass constituents that are relevant to certain product streams has shown positive preliminary results, opening the possibility for extensions to the outputs of this powerful data type. All models are accompanied by prediction uncertainties and unsupervised spectral outlier detection to alert an operator to unreliable spectral data. These tools can be deployed for rapid determination of algal culture status, and cultivation and biomass quality improvement.

algal biofuels↗

Reduction of uranyl and uranyl-organic complexes mediated by magnetite and ilmenite: A combined electrochemical AFM and DFT study

Reduction of mobile aqueous uranyl complexes can be hindered by the strength of the uranyl-ligand complex and the resistivity of the complexes to electron transfer. Semiconducting solids, such as magnetite (Fe 3 O 4 ) and ilmenite (FeTiO 3 ), can facilitate otherwise-slow electron transfer between the reductant and oxidant, especially if these species are adsorbed on their surfaces as inner-sphere complexes. Electrons can then be shuttled through the surface or the structure. This process can be facilitated by either finding a new electron transfer path or by weakening or destroying the ligand-uranyl complex. Using in situ electrochemical atomic force microscopy (EC-AFM), we imaged reduction products of uranyl as mediated by magnetite and ilmenite in the absence or presence of the organic ligands, ethylenediaminetetraacetate (EDTA) and oxalate. In situ images of uranyl reduction show gradual nucleation and growth of reduced uranium on the mineral surfaces with decreasing reduction potentials. X-ray photoelectron spectroscopy (XPS) measurements indicate pentavalent uranium as the dominant uranium species resulting from uranyl reduction mediated by magnetite and ilmenite. The reduction potentials of uranyl-organic species relevant to our reaction system, (U VI O 2 ∙oxalate) 0 and (U VI O 2 ∙HEDTA) - , are derived using quantum–mechanical modeling and compared with the midpoint potentials obtained from cyclic voltammetry measurements. The spectroscopic, electrochemical, and computational data suggest that the catalysis of Fe-bearing minerals facilitates the reduction of uranyl-organic complexes. U(VI)-oxalate complexes are redox-active and participate directly in the reduction mediated by magnetite. In the presence of EDTA, reduction of uranyl may proceed in concert with ligand exchange between metals (i.e., U and Fe) on the mineral surface. Finally, the proposed mechanism is the breaking of uranyl-organic bonds upon interaction with the mineral surface followed by the formation of Fe-organic bonds, thereby allowing the reduction of hexavalent uranyl to pentavalent one.

58 GEOSCIENCES↗

TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95% behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of any of the supporting organizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Successful In Situ Remediation of Cr(VI)-Impacted Deeper Vadose Zone Soils for Groundwater Protection - 18603

Shallow soil at a former industrial wood treating facility was impacted with chromium, arsenic, and copper above cleanup goals and shallow soil has been excavated for protection of direct contact exposure pathways. Deeper vadose zone soil was predominantly impacted with chromium and was undergoing remediation for long-term groundwater protection. The 920-meter (m) long Cr(VI) groundwater plume has undergone full-scale remediation with groundwater recirculation and in situ bioremediation. Following approximately 4 years of operation, the Cr(VI) groundwater plume, with former source area groundwater concentrations over 10,000 micrograms per liter (μg/L), has been reduced to below the laboratory method reporting limit (0.50 μg/L). Approximately 23,000 cubic meters (m{sup 3}) of deeper (4.5 m - 11 m below ground surface, bgs) vadose zone soil required Cr(VI) remediation. The remediation strategy relied on reduction of Cr(VI) and geochemical fixation as trivalent chromium (Cr(III)) and iron hydroxide precipitates. Chromium reduction was facilitated by a carbon source (corn syrup and methanol) to establish and maintain biogeochemical reducing conditions and ferrous iron to support direct Cr(VI) chemical reduction. Combined, the injected soil moisture, carbon source and ferrous iron supported fast and sustained ferrous/ferric iron cycling and Cr(VI) reduction. Remedy performance monitoring included time-series water quality data from a network of vacuum lysimeters and confirmation soil borings. Reagent was applied either through liquid injection wells and direct-push injection points, or by deep soil mixing methodology in areas with difficult geology (i.e., fine-grained soils and discontinuous iron-silica hardpan layer). Following both phases of deep soil remediation, soils met long-term protection of groundwater remediation action objectives. In situ treatment of soils provides a cost-effective remedial solution compared to excavation, specifically when impacts are deep and long-term protection of groundwater is a primary remediation goal. The delivery methods employed in this case study can be applied to sites impacted with a broad range of contaminants amendable to geochemical fixation (e.g., chromium, uranium, strontium, nitrate, etc.). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrospinning of Poly (ethylene-co-vinyl acetate)/Clay Nanocomposite Fibers

Poly(ethylene-co-vinyl acetate)/clay nanocomposite fibers were fabricated using electrospinning. The fiber diameters were controlled by varying the polymer/chloroform concentration, which resulted in fibers with diameters ranging from 1 to 15 {micro}m. The clay concentration was varied from 0.35 to 6.6 wt %. Scanning electron microscopy revealed that the fiber diameter increased with increasing clay concentration, whereas beading decreased. Transmission electron microscopy revealed a disruption of the spherulite structures by clay, which is consistent with heterogeneous nucleation. Shear modulus force microscopy indicated a reduction in melting point (T{sub m}) with decreasing diameter for fibers thinner than 15 {micro}m, which was confirmed by temperature dependent X-ray diffraction data. For fibers thinner than 8 {micro}m, the presence of clay further enhanced the reduction of T{sub m}.

36 MATERIALS SCIENCE↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

Workplace Charge Management with Aggregated Building Loads

This paper describes a workplace charge management system developed to control plug-in electric vehicle charging stations based on aggregated building loads. A system to collect information from drivers was also developed for better charge management performance since the present AC charging station standard does not provide battery state of charge information. First, simulations with uncontrolled charging data were conducted to investigate several scenarios and control methods, and then one method with the most power curtailment during peak load was selected for verification tests. This paper illustrates load reduction test results for 36 charging stations and real-time campus net load data.

25 ENERGY STORAGE↗

An Advanced Catalytic Solvent for Lower Cost Post-Combustion CO 2 Capture in a Coal-Fired Power Plant

In this report, CAER addresses DOE’s objectives for improvements on post-combustion CO 2 capture through a three-fold approach including 1) advanced solvent, 2) homogeneous catalyst and 3) membrane carbon enrichment system. CAER-B3 solvent was formulated to improve the overall thermodynamics with the addition of a proton receiver while maintaining faster kinetics with the addition of thermally robust primary amine. The EH&S study indicates that CAER-B3 solvent poses little human toxicological or ecological risk in its raw material form. Generation of significant quantities of nitrosamines was deemed unlikely when using B3 solvent for CO 2 capture from coal-derived flue gas. The catalytic solvent caused a 21% reduction in energy demand, achievable via decreasing the liquid flowrate. Cyclic capacity nearly doubled due to the slower flowrate, and therefore, reduced the sensible heat required to remove CO 2 in the stripper. The increased rich loadings achieved by either pre-concentrating membrane or dewatering membrane prior to stripper, in addition to improved cyclic capacity, will lower downstream compression costs, while reducing the energy consumption per unit of CO 2 produced. Moreover, the CAER-B3 solvent demonstrated a greater thermal stability, lessening the rate of amine loss, caused by solvent degradation and emissions, by 50-70%. The CAER developed catalysts with a second order rate constant of 7.5 x 10 4 – 10 5 M -1 s -1 , far beyond those reported to date. The catalyst was designed to be a mimic of the enzyme carbonic anhydrase and increase the rate of CO 2 hydration to produce bicarbonate. As such, a 10-25% improvement in absorption rate was observed over the MEA base case. Enhancements can be imparted to the full scale system to reduce packing height of the absorber column, resulting in significant capital cost savings. Furthermore, the family of CAER catalysts showed less than 10% decomposition over 100 hours at 100 °C, suggesting that these catalysts will be stable in the harsh oxidative and thermal process conditions of an industrial carbon capture unit. Flue gas contaminants, such as NO x and SO x , also did not impact catalytic activity. A method for synthetic production of 500 g/batch was designed, verified, and well-documented, with scaling capabilities up to 500 kg. Two types of membranes were designed and tested for the purpose of increasing the solvent carbon loading prior to entering the stripper column. 500 hour and 100 hour verification studies were completed for the pre-concentrating membrane and zeolite dewatering membrane, respectively. Results demonstrated that a membrane-based CO 2 enrichment step using a commercial CO 2 membrane, or a zeolite dewatering membrane, or both, should be implemented in the carbon capture process to increase the CO 2 partial pressure by 16%, resulting in a stripping energy reduction of 35% relative to DOE Case 12 MEA solvent. Experimental data showed a carbon loading enrichment of 18-40% in comparison to the configuration without the pre-concentrating gas membrane. During the timespan of this project, challenges were identified and addressed so that enhanced performance may be realized long-term. Mitigation implementations included re-configuration of the bench unit with a solvent recovery column and a knock-out drum, as well as an increase in stripper pressure set point. Both changes resulted in a considerable reduction in the rate of solvent loss. Additionally, the membrane synthesis procedure was modified and validated to address zeolite dissolution concerns along with a new separation module. The techno-economic analysis conducted by WorleyParsons indicated the CAER-adCCS hybrid approach may outperform NETL Case 12 with regards to net plant HHV efficiency and cost of electricity.

01 COAL, LIGNITE, AND PEAT↗

High resolution dual detector volume-of-interest cone beam breast CT - Demonstration with a bench top system

Purpose: In this study, we used a small field high resolution detector in conjunction with a full field flat panel detector to implement and investigate the dual detector volume-of-interest (VOI) cone beam breast computed tomography (CBCT) technique on a bench-top system. The potential of using this technique to image small calcifications without increasing the overall dose to the breast was demonstrated. Significant reduction of scatter components in the high resolution projection image data of the VOI was also shown. Methods: With the regular flat panel based CBCT technique, exposures were made at 80 kVp to generate an air kerma of 6 mGys at the isocenter. With the dual detector VOI CBCT technique, a high resolution small field CMOS detector was used to scan a cylindrical VOI (2.5 cm in diameter and height, 4.5 cm off-center) with collimated x-rays at four times of regular exposure level. A flat panel detector was used for full field scan with low x-ray exposures at half of the regular exposure level. The low exposure full field image data were used to fill in the truncated space in the VOI scan data and generate a complete projection image set. The Feldkamp-Davis-Kress (FDK) filtered backprojection algorithm was used to reconstruct high resolution images for the VOI. Two scanning techniques, one breast centered and the other VOI centered, were implemented and investigated. Paraffin cylinders with embedded thin aluminum (Al) wires were imaged and used in conjunction with optically stimulated luminescence (OSL) dose measurements to demonstrate the ability of this technique to image small calcifications without increasing the mean glandular dose (MGD). Results: Using exposures that produce an air kerma of 6 mGys at the isocenter, the regular CBCT technique was able to resolve the cross-sections of Al wires as thin as 254 {mu}m in diameter in the phantom. For the specific VOI studied, by increasing the exposure level by a factor of 4 for the VOI scan and reducing the exposure level by a factor of 2 for the full filed scan, the dual-detector CBCT technique was able to resolve the cross-sections of Al wires as thin as 152 {mu}m in diameter. The CNR evaluated for the entire Al wire cross-section was found to be improved from 5.5 in regular CBCT to 14.4 and 16.8 with the breast centered and VOI centered scanning techniques, respectively. Even inside VOI center, the VOI scan resulted in significant dose saving with the dose reduced by a factor of 1.6 at the VOI center. Dose saving outside the VOI was substantial with the dose reduced by a factor of 7.3 and 7.8 at the breast center for the breast centered and VOI centered scans, respectively, when compared to full field scan at the same exposure level. The differences between the two dual detector techniques in terms of dose saving and scatter reduction were small with VOI scan at 4x exposure level and full field scan at 0.5x exposure level. The MGDs were only 94% of that from the regular CBCT scan. Conclusions: For the specific VOI studied, the dual detector VOI CBCT technique has the potential to provide high quality images inside the VOI with MGD similar to or even lower than that of full field breast CBCT. It was also found that our results were compromised by the use of inadequate detectors for the VOI scan. An appropriately selected detector would better optimize the image quality improvement that can be achieved with the VOI CBCT technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of plastic properties on the grain size effect on twinning in Ti and Mg

Deformation twinning is an inevitable mode of plastic deformation in hexagonal close packed (HCP) crystals and has been considered a hinderance to achieving formability and ductility. It has long been recognized that reductions in grain size can lower the propensity for twinning. In prior work, EBSD statistical analyses on big data sets of twins in pure Ti and Mg were carried out for the same twin type, loading conditions, initial texture, and range of grain sizes. Here, we revisit these data sets to investigate the role of material plastic properties on grain size effects on deformation twinning. We show that while reductions in grain size dramatically lower the number of twins per grain and the twin thickness in both metals, these effects are several times stronger in Ti than that for Mg. To rationalize this difference, full-field, 3D crystal plasticity calculations are performed. The analysis indicates that the stronger grain size effect in Ti arises due to the larger critical resolved shear stress (CRSS) of its easiest slip system, making Ti less accommodating of the twin shear than Mg. Overall, this result points to plastic properties as additional variables that can be tuned towards developing HCP materials for structural applications.

36 MATERIALS SCIENCE↗

Efficient and Flexible Hierarchical Data Layouts for a Unified Encoding of Scalar Field Precision and Resolution

To address the problem of ever-growing scientific data sizes making data movement a major hindrance to analysis, we introduce a novel encoding for scalar fields: a unified tree of resolution and precision, specifically constructed so that valid cuts correspond to sensible approximations of the original field in the precision-resolution space. Furthermore, we introduce a highly flexible encoding of such trees that forms a parameterized family of data hierarchies. We discuss how different parameter choices lead to different trade-offs in practice, and show how specific choices result in known data representation schemes such as zfp[52], idx[58], and jpeg2000 [76]. Lastly, we provide system-level details and empirical evidence on how such hierarchies facilitate common approximate queries with minimal data movement and time, using real-world data sets ranging from a few gigabytes to nearly a terabyte in size. Experiments suggest that our new strategy of combining reductions in resolution and precision is competitive with state-of-the-art compression techniques with respect to data quality, while being significantly more flexible and orders of magnitude faster, and requiring significantly reduced resources.

97 MATHEMATICS AND COMPUTING↗