Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consequence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

On the Cutting of Metals: A Mechanics Viewpoint

The mechanics of large-strain deformation in cutting of metals is discussed, primarily from viewpoint of recent developments in in situ analysis of plastic flow and microstructure characterization. It is shown that a broad range of deformation parameters can be accessed in chip formation—strains of 1–10, strain rates of 10–10 5 /s, and temperatures up to 0.7T m —and controlled. This range is far wider than achievable by any other single-stage, severe plastic deformation (SPD) process. The resulting extreme deformation conditions produce a rich variety of microstructures in the chip. Four principal types of chip formation—continuous, shear-localized, segmented, and mushroom-type—as elucidated first by Nakayama (1974, “The Formation of ‘Saw-Toothed Chip’ in Metal Cutting,” Proceedings of International Conference on Production Engineering, Tokyo, pp. 572–577) are utilized to emphasize the diverse plastic flow phenomena, especially unsteady deformation modes that prevail in cutting. These chip types are intimately connected with the underlying flow, each arising from a distinct mode and triggered by an instability phenomenon. The role of plastic flow instabilities such as shear banding, buckling, and fracture in mediating unsteady flow modes is expounded, along with consequences of the flow modes and chip types for the cutting. Sinuous flow is shown to be the reason why gummy (highly strain-hardening) metals, although relatively soft, are so difficult to cut. Synthesizing the various observations, a hypothesis is put forth that it is the stability of flow modes that determines the mechanics of cutting. Furthermore, this leads to a flow-stability phase diagram that could provide a framework for predicting chip types and process attributes.

42 ENGINEERING↗

Evaluation of Spray and Combustion Models for Simulating Dilute Combustion in a Direct-Injection Spark-Ignition Engine

Dilute combustion in spark-ignition engines has the potential to improve thermal efficiency by mitigating knock and by reducing throttling and wall heat losses. However, ignition and combustion processes can become unstable for dilute operation due to a lowered laminar flame speed, resulting in excessive cycle-to-cycle variability (CCV) of the combustion process. To compensate for the slower combustion in less reactive mixtures, a modified intake port geometry can be employed to generate a strong tumble flow in the cylinder and elevate turbulence levels around the spark plug, thereby promoting a faster transition to turbulent deflagration. Consequently, optimizing combustion chamber geometry and operating strategy is crucial to maximizing the benefits of using dilute combustion with enhanced in-cylinder turbulence across a wide range of operating conditions. Computational fluid dynamics (CFD) simulations can be utilized for virtual engine optimization tasks, but this would require the models to be truly predictive regarding the impact of changes to the engine design and operational parameters.In this study, multicycle large-eddy simulations (LES) are performed for a direct-injection spark-ignition engine to investigate the model performance in predicting engine combustion characteristics with respect to changes in the intake configuration. A tumble plate that blocks the lower part of the intake port inlet is used to vary the tumble. A set of CFD models that have been recently developed are employed, which takes into account the drag of nonspherical droplets, flash-boiling behavior of liquid sprays, spray-wall interaction, surrogate formulation of a research-grade E10 gasoline, and fast chemical kinetic solvers. Simulation results are compared to experimental engine data in terms of cylinder pressure, apparent heat release rate, mass fraction burned timing, and flame images. It is found that LES employing the state-of-the-art CFD models are capable of properly predicting the spray processes and reproducing the measured mean cylinder pressure for the case with the tumble plate. On the other hand, the LES over-predicts the combustion rate during the early combustion stage and under-estimates the CCV, and these discrepancies become larger when the tumble plate is removed.

computational fluid dynamics simulation↗

The role of large scale demonstration experiments in supporting the implementation of a high level waste programme

Large scale demonstration experiments in underground research laboratories (both onsite and off-site) are currently undertaken by most high level radioactive waste management organisations. The decision to plan and implement prototype experiments, which might have a life of several decades, has both important strategic and budgetary consequences for the organisation. Careful definition of experimental objectives based on the design and safety requirements is critical. The implementation requires the involvement of many parties and needs flexible but consequent management as, for example, additional goals for the experiments, identified in the course of the implementation, might jeopardise initial primary goals. The outcomes of an international workshop in which European and Japanese implementers (SKB, Posiva, Andra, ONDRAF, NUMO and Nagra) but also certain research organisations (JAEA, RWMC) participated identified which experiments are likely to be needed depending on the progress in implementing a disposal programme. Already earlier in a programme, large scale demonstrations are generally performed aiming at reducing uncertainties identified during the safety case development such as thermo-hydraulic-mechanical process validation in the engineered barrier system and target host rock. Also feasibility testing of underground construction in a potential host rock at relevant depth might be required. Later in a programme, i.e., closer to the license application, large scale experiments aim largely at demonstrating engineering feasibility and performance confirmation of complete repository components. Ultimately, before licensing repository operation, 1:1 scale commissioning testing will be required. Factors contributing to the successful completion of large scale demonstration experiments in terms of planning, defining the objectives, optimising results and main lessons learned over the last 30 years are being discussed. The need for international coordination in defining the objectives of new large scale demonstration experiments is addressed. The paper is expected to provide guidance to implementing organisations (especially those in their early stages of the programme), considering participating in and/or or conducting on their own large scale experiments in the near future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Cracks in Cementitious Engineered Barriers in a Near-Surface Disposal System: Assessment Analysis of the Belgian Case

In large cement-based structures such as a near surface disposal facility for radioactive waste voids and cracks are inevitable. However, the pattern and nature of cracks are very difficult to predict reliably. Cracks facilitate preferential water flow through the facility because their saturated hydraulic conductivity is generally higher than the conductivity of the cementitious matrix. Moreover, sorption within the crack is expected to be lower than in the matrix and hence cracks in engineered barriers can act as a bypass for radionuclides. Consequently, understanding the effects of crack characteristics on contaminant fluxes from the facility is of utmost importance in a safety assessment. In this paper we numerically studied radionuclide leaching from a crack-containing cementitious containment system. First, the effect of cracks on radionuclide fluxes is assessed for a single repository component which contains a radionuclide source (i.e. conditioned radwaste). These analyses reveal the influence of cracks on radionuclide release from the source. The second set of calculations deals with the safety assessment results for the planned near-surface disposal facility for low-level radioactive waste in Dessel (Belgium); our focus is on the analysis of total system behaviour in regards to release of radionuclide fluxes from the facility. Simulation results are interpreted through a complementary safety indicator (radiotoxicity flux). We discuss the possible consequences from different scenarios of cracks and voids. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermo-Oxidation Analysis of Structural Adhesives: An Experimental Study

Abstract Cross-linked polymers play an important role in structural applications as adhesives. In this article, we performed an experimental study to understand the effects of high temperature i.e. thermo-oxidative aging on the mechanical behavior of polymers. Subsequently, the constitutive behavior, i.e. stress-strain relation of these adhesives before and after the accelerated aging tests were studied on samples aged at different temperature and different time durations at zero humidity. The aging conditions and periods selected for the tests have been specifically designed to simulate the effects of aging under the working conditions that the materials will be subjected to in their standard applications. The focus of this study is on the investigation of the effects of aging on the polymeric adhesives used in automotive applications. Consequently, four different polymeric adhesives (one silicone-based, two polyurethane-based, and one acrylic type), which are being used extensively in these applications, have been chosen. The quasi-static tensile loading was used on these four adhesives and the changes in the constitutive behavior were measured. The failure tensile tests as well as the cyclic tensile tests were performed in our lab using a Test-Resources tensile testing machine. The temperatures that were used in this work are 60, 80 and 95°C for varying aging periods of 24hrs, 240hrs, and 720hrs. Then, all the data was collected and consequently analyzed, and the resulting behavior was compared to that of the unaged material, showing varying results depending on the material, temperature, and aging period. Different behaviors have been observed after aging. The polymers’ behavior was expanding from no effect to significant damage caused by aging conditions. This work provides the core understanding required for modeling the material behavior during aging and lays down the groundwork for further data-infused model-free approaches.

Alazhary, Sharif↗

INITIATORS AND TRIGGERING CONDITIONS FOR ADAPTIVE AUTOMATION IN ADVANCED SMALL MODULAR REACTORS

It is anticipated that Advanced Small Modular Reactors (AdvSMRs) will employ high degrees of automation. High levels of automation can enhance system performance, but often at the cost of reduced human performance. Automation can lead to human out-of the loop issues, unbalanced workload, complacency, and other problems if it is not designed properly. Researchers have proposed adaptive automation (defined as dynamic or flexible allocation of functions) as a way to get the benefits of higher levels of automation without the human performance costs. Adaptive automation has the potential to balance operator workload and enhance operator situation awareness by allocating functions to the operators in a way that is sensitive to overall workload and capabilities at the time of operation. However, there still a number of questions regarding how to effectively design adaptive automation to achieve that potential. One of those questions is related to how to initiate (or trigger) a shift in automation in order to provide maximal sensitivity to operator needs without introducing undesirable consequences (such as unpredictable mode changes). Several triggering mechanisms for shifts in adaptive automation have been proposed including: operator initiated, critical events, performance-based, physiological measurement, model-based, and hybrid methods. As part of a larger project to develop design guidance for human-automation collaboration in AdvSMRs, researchers at Idaho National Laboratory have investigated the effectiveness and applicability of each of these triggering mechanisms in the context of AdvSMR. Researchers reviewed the empirical literature on adaptive automation and assessed each triggering mechanism based on the human-system performance consequences of employing that mechanism. Researchers also assessed the practicality and feasibility of using the mechanism in the context of an AdvSMR control room. Results indicate that there are tradeoffs associated with each mechanism, but that some are more applicable to the AdvSMR domain. The two mechanisms that consistently improve performance in laboratory studies are operator initiated adaptive automation based on hierarchical task delegation and the Electroencephalogram(EEG) –based measure of engagement. Current EEG methods are intrusive and require intensive analysis; therefore it is not recommended for an AdvSMR control rooms at this time. Researchers also discuss limitations in the existing empirical literature and make recommendations for further research.

99 GENERAL AND MISCELLANEOUS↗

Surface characterization of nanomaterials and nanoparticles: Important needs and challenging opportunities

This review examines characterization challenges inherently associated with understanding nanomaterials and the roles surface and interface characterization methods can play in meeting some of the challenges. In parts of the research community, there is growing recognition that studies and published reports on the properties and behaviors of nanomaterials often have reported inadequate or incomplete characterization. As a consequence, the true value of the data in these reports is, at best, uncertain. With the increasing importance of nanomaterials in fundamental research and technological applications, it is desirable that researchers from the wide variety of disciplines involved recognize the nature of these often unexpected challenges associated with reproducible synthesis and characterization of nanomaterials, including the difficulties of maintaining desired materials properties during handling and processing due to their dynamic nature. It is equally valuable for researchers to understand how characterization approaches (surface and otherwise) can help to minimize synthesis surprises and to determine how (and how quickly) materials and properties change in different environments. Appropriate application of traditional surface sensitive analysis methods (including x-ray photoelectron and Auger electron spectroscopies, scanning probe microscopy, and secondary ion mass spectroscopy) can provide information that helps address several of the analysis needs. In many circumstances, extensions of traditional data analysis can provide considerably more information than normally obtained from the data collected. Less common or evolving methods with surface selectivity (e.g., some variations of nuclear magnetic resonance, sum frequency generation, and low and medium energy ion scattering) can provide information about surfaces or interfaces in working environments (operando or in situ) or information not provided by more traditional methods. Although these methods may require instrumentation or expertise not generally available, they can be particularly useful in addressing specific questions, and examples of their use in nanomaterial research are presented.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analytic expressions for atomic layer deposition: Coverage, throughput, and materials utilization in cross-flow, particle coating, and spatial atomic layer deposition

In this work, the authors present analytic models for atomic layer deposition (ALD) in three common experimental configurations: cross-flow, particle coating, and spatial ALD. These models, based on the plug-flow and well-mixed approximations, allow us to determine the minimum dose times and materials utilization for all three configurations. A comparison between the three models shows that throughput and precursor utilization can each be expressed by universal equations, in which the particularity of the experimental system is contained in a single parameter related to the residence time of the precursor in the reactor. For the case of cross-flow reactors, the authors show how simple analytic expressions for the reactor saturation profiles agree well with experimental results. Consequently, the analytic model can be used to extract information about the ALD surface chemistry (e.g., the reaction probability) by comparing the analytic and experimental saturation profiles, providing a useful tool for characterizing new and existing ALD processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using block-copolymer nanolithography as a tool to sensitively evaluate variation in chemical dry etching rates of semiconductor materials with sub-5 nm resolution

Ion implantation is a robust and established method to customize the electronic properties of Si. However, fabricating doped, ultrafine semiconductor nanostructures can be challenging. Ion implantation has well-established effects on the dry etch rates of Si, which becomes increasingly consequential as the target dimension shrinks below a few tens of nanometers. While dry etching arrays of block copolymer-templated nanoscale holes (pitch = 37.5 nm, diameter ~25 nm) into p-type, n-type, and undoped Si, we observed that the lateral etch rate was notably larger for the n-type regions than p-type or undoped regions. By doing image analyses on high resolution electron micrographs of the nanostructured hole arrays, we were able to extract the porosity and average radii of the holes with subnanometer sensitivity and compare the relative etch rates between different doping conditions. We found that degenerately doped n-type silicon consistently etches between approximately 17% and 27% faster in the lateral direction than p-type Si, resulting in significantly larger porosity and, consequently, less mechanical stability. Here, we demonstrate that top-down dimensional analysis of a densely packed porous nanostructure is a robust method for assessing extremely small differences in the lateral, chemical etch rate of doped Si to a degree of sensitivity that was previously unachievable. The minute, dense-packed nature of block copolymer self-assembled nanostructures is shown to be ideal for this application. This proposed method could be useful for designing fabrication processes for heterogeneous nanostructures, as slight dry etch rate variations that may be within process tolerance at the micrometer-scale appear to have nontrivial consequences at the nanometer scale.

42 ENGINEERING↗

Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator

Purpose: The delivery of high quality stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) treatments to the patient requires knowledge of the position of the isocenter to submillimeter accuracy. To meet the requirements the deviation between the radiation and mechanical isocenters must be less than 1 mm. The use of add-on micromultileaf collimators ({mu}MLCs) in SRS and SRT is an additional challenge to the anticipated high-level geometric and dosimetric accuracy of the treatment. The aim of this work was to quantify the gantry excursions during rotation with and without an add-on {mu}MLC attached to the gantry head. In addition, the shift in the position of the isocenter and its correlation to the kV beam center of the cone-beam CT system was included in the study. Methods: The quantification of the gantry rotational performance was done using a pointer supported by an in-house made rigid holder attached to the gantry head of the accelerator. The pointer positions were measured using a digital theodolite. To quantify the effect of an {mu}MLC of 50 kg, the measurements were repeated with the {mu}MLC attached to the gantry head. The displacement of the isocenter due to an add-on {mu}MLC of 50 kg was also investigated. In case of the pointer measurement the {mu}MLC was simulated by weights attached to the gantry head. A method of least squares was applied to determine the position and displacement of the mechanical isocenter. Additionally, the displacement of the radiation isocenter was measured using a ball-bearing phantom and the electronic portal image device system. These measurements were based on 8 MV photon beams irradiated onto the ball from the four cardinal angles and two opposed collimator angles. The measurements and analysis of the data were carried out automatically using software delivered by the manufacturer. Results: The displacement of the mechanical isocenter caused by a 50 kg heavy {mu}MLC was found to be (-0.01 {+-} 0.05, -0.10 {+-} 0.03, -0.26 {+-} 0.05) mm in lateral, longitudinal, and vertical direction, respectively. Similarly, the displacement of the radiation isocenter was found to be (0.00 {+-} 0.03, -0.08 {+-} 0.06, -0.32 {+-} 0.02) mm. Good agreement was found between the displacement of the two isocenters. A displacement of the kV cone-beam CT beam center due to the attached weight of 50 kg could not be detected. Conclusions: General characteristics of the gantry arm excursions and displacements caused by an add-on {mu}MLC have been reported. A 50 kg heavy add-on {mu}MLC results in a isocenter displacement downward of 0.26-0.32 mm. The authors recommend that the beam center of the kV cone-beam CT image system should be matched to the isocenter related to the weight of the {mu}MLC. Consequently, the imperfections in isocenter localizations are transferred to the conventional radiotherapy where the clinical consequences of uncertainties in the submillimeter regime are negligible.

60 APPLIED LIFE SCIENCES↗

Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck

Purpose: To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Methods: Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. Results: The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or −0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1–2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39–16.8) cGy, or 10.1 (0.8–32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%–9.06%) and 10.2% (0.7%–63.6%), respectively. Conclusions: Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup, the standard deviation of setup error reduced by 31%, 42%, and 54% in RL, AP, and SI direction, respectively, and consequently, the uncertainty of the mean dose to cochlea reduced more than 50%. The authors estimate that the effects of these uncertainties on the probability of hearing loss for an individual patient could be as large as 10%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy

Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for{sup 103}Pd seeds and smallest but still considerable differences for {sup 131}Cs seeds. Conclusions: Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying cell migration distance as a contributing factor to the development of rectal toxicity after prostate radiotherapy

Purpose: Spatial information is usually neglected in mathematical models of radiation-induced toxicity. In the presence of inhomogeneous dose distributions produced by intensity modulated radiation therapy (IMRT) and volumetric arc therapy, this may be a limitation. We present a model to quantify the spatial characteristics of the dose distribution on the rectum through the quantification of the distribution of distances between dose points on the surface of the rectum in three-dimensions. The method allows us to evaluate the hypothesis that distances between lower and higher dose regions on the rectum influence radiation damage repair due to the migration of normal cells into damaged areas, and consequently, the development of radiation-induced toxicity in patients treated with radiation for prostate cancer. Methods: We present a method to compute distances between dose points on the surface of the rectum in three dimensions (3D) and to generate distance maps representing the distances between specific dose regions on the rectum. We introduce the concept of the distance dose surface histogram (DDSH), which is computed from the distance maps. The DDSH is a 2D histogram of rectum area on a grid defined by pairwise combinations of dose and distance. Each bin in the DDSH quantifies the area of the rectum exposed to a given dose and at a given distance from other another dose region on the rectum. By summing across the columns and rows of the DDSH, we can generate the dose surface histogram (DSH) and distance surface histogram (DiSH) for a particular dose region. The DiSH is a marginal histogram showing the distribution of distances for the dose points in a specific dose region from another region. We computed the DDSH, DiSH, and DSH for 33 patients treated with IMRT for prostate cancer, nine of whom developed late Grade 2 or higher late rectal toxicity. Results: We show how even though the total area of the rectum exposed to a given dose may be the same for different patients, the distribution of distances for points receiving that dose can be different depending on the shape and contiguity of the region(s) containing those dose points. We also show that area of the rectum in the region receiving more than 75 Gy and at a distance of 16 to 22 mm from the 50 Gy isodose line was significantly correlated to the development of toxicity (p = 0.004, two sided t-test). This suggests that examining the distance distribution of points in specific dose regions could provide valuable additional information in predicting the risk of a patient developing radiation-induced rectal toxicity. Conclusions: We present a new method to quantify the spatial distribution of points in a given region relative to other regions on the rectum. The method provides a means to evaluate the hypothesis that distances between lower and higher dose regions on the rectum influence radiation damage repair due to the migration of normal cells into damaged areas, and may be a contributing factor to the development of radiation-induced toxicity in patients treated with radiation for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B{sub 0}) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B{sub 0} inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the computation time by obviating the need for iterative calculations of the PET emission data beyond those required for reconstructing images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRE-05: Development and Evaluation of a Real-Time Robotic 6D Quality Assurance Phantom

Purpose: A 6 degree-of-freedom robotic phantom capable of reproducing dynamic tumor motion in 6D was designed to more effectively match solid tumor movements throughout pre-treatment scanning and radiation therapy. With the abundance of optical and x-ray 6D real-time tumor tracking methodologies clinically available, and the substantial dosimetric consequences of failing to consider tumor rotation as well as translation, this work presents the development and evaluation of a 6D instrument with the facility to improve quality assurance. Methods: An in-house designed and built 6D robotic motion phantom was constructed following the so-called Stewart-Gough parallel kinematics platform archetype. The device was then controlled using an inverse kinematics formulation, and precise movements in all six degrees of freedom (X, Y, Z, pitch, roll, and yaw) as well as previously obtained cranial motion, were effectively executed. The robotic phantom movements were verified using a 15 fps 6D infrared marker tracking system (Polaris, NDI), and quantitatively compared to the input trajectory. Thus, the accuracy and repeatability of 6D motion was investigated and the phantom performance was characterized. Results: Evaluation of the 6D platform demonstrated translational RMSE values of 0.196 mm, 0.260 mm, and 0.101 mm over 20 mm in X and Y and 10 mm in Z, respectively, and rotational RMSE values of 0.068 degrees, 0.0611 degrees, and 0.095 degrees over 10 degrees of pitch, roll, and yaw, respectively. The robotic stage also effectively performed controlled 6D motions, as well as reproduced cranial trajectories over 15 minutes, with a maximal RMSE of 0.044 mm translationally and 0.036 degrees rotationally. Conclusion: This 6D robotic phantom has proven to be accurate under clinical standards and capable of reproducing tumor motion in 6D. Consequently, such a robotics device has the potential to serve as a more effective system for IGRT QA that involves both translational and rotational dimensions. Research was partially funded by NIH Grant T32 EB002103-21 from NIBIB. Contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIBIB or NIH.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-11: Adaptive-Beamlet Based Finite Size Pencil Beam (AB-FSPB) Dose Calculation Algorithm for Independent Verification of IMRT and VMAT

Purpose: In current IMRT and VMAT settings, the use of sophisticated dose calculation procedure is inevitable in order to account complex treatment field created by MLCs. As a consequence, independent volumetric dose verification procedure is time consuming which affect the efficiency of clinical workflow. In this study, the authors present an efficient Pencil Beam based dose calculation algorithm that minimizes the computational procedure while preserving the accuracy. Methods: The computational time of Finite Size Pencil Beam (FSPB) algorithm is proportional to the number of infinitesimal identical beamlets that constitute the arbitrary field shape. In AB-FSPB, the dose distribution from each beamlet is mathematically modelled such that the sizes of beamlets to represent arbitrary field shape are no longer needed to be infinitesimal nor identical. In consequence, it is possible to represent arbitrary field shape with combinations of different sized and minimal number of beamlets. Results: On comparing FSPB with AB-FSPB, the complexity of the algorithm has been reduced significantly. For 25 by 25 cm2 squared shaped field, 1 beamlet of 25 by 25 cm2 was sufficient to calculate dose in AB-FSPB, whereas in conventional FSPB, minimum 2500 beamlets of 0.5 by 0.5 cm2 size were needed to calculate dose that was comparable to the Result computed from Treatment Planning System (TPS). The algorithm was also found to be GPU compatible to maximize its computational speed. On calculating 3D dose of IMRT (∼30 control points) and VMAT plan (∼90 control points) with grid size 2.0 mm (200 by 200 by 200), the dose could be computed within 3∼5 and 10∼15 seconds. Conclusion: Authors have developed an efficient Pencil Beam type dose calculation algorithm called AB-FSPB. The fast computation nature along with GPU compatibility has shown performance better than conventional FSPB. This completely enables the implantation of AB-FSPB in the clinical environment for independent volumetric dose verification.

60 APPLIED LIFE SCIENCES↗

Automated identification of retinal vessels using a multiscale directional contrast quantification (MDCQ) strategy

Purpose: A novel algorithm is presented to automatically identify the retinal vessels depicted in color fundus photographs. Methods: The proposed algorithm quantifies the contrast of each pixel in retinal images at multiple scales and fuses the resulting consequent contrast images in a progressive manner by leveraging their spatial difference and continuity. The multiscale strategy is to deal with the variety of retinal vessels in width, intensity, resolution, and orientation; and the progressive fusion is to combine consequent images and meanwhile avoid a sudden fusion of image noise and/or artifacts in space. To quantitatively assess the performance of the algorithm, we tested it on three publicly available databases, namely, DRIVE, STARE, and HRF. The agreement between the computer results and the manual delineation in these databases were quantified by computing their overlapping in both area and length (centerline). The measures include sensitivity, specificity, and accuracy. Results: For the DRIVE database, the sensitivities in identifying vessels in area and length were around 90% and 70%, respectively, the accuracy in pixel classification was around 99%, and the precisions in terms of both area and length were around 94%. For the STARE database, the sensitivities in identifying vessels were around 90% in area and 70% in length, and the accuracy in pixel classification was around 97%. For the HRF database, the sensitivities in identifying vessels were around 92% in area and 83% in length for the healthy subgroup, around 92% in area and 75% in length for the glaucomatous subgroup, around 91% in area and 73% in length for the diabetic retinopathy subgroup. For all three subgroups, the accuracy was around 98%. Conclusions: The experimental results demonstrate that the developed algorithm is capable of identifying retinal vessels depicted in color fundus photographs in a relatively reliable manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-216: A Sequence Independent Approach for Quantification of MR Image Deformations From Brachytherapy Applicators

Purpose: MRI is increasingly used as a single imaging modality for brachytherapy treatment planning. The presence of a brachytherapy applicator may cause distortions in the images, especially at higher field strengths. Our aim is to develop a procedure to quantify these distortions theoretically for any MR-sequence and to verify the estimated deformations for clinical sequences. Methods: Image distortions due to perturbation of the B0-field are proportional to the ratio of the induced frequency shift and the read-out bandwidth of the applied sequence. By reconstructing a frequency-shift map from the phase data from a multi-echo sequence, distortions can be calculated for any MR-sequence. Verification of this method for estimating distortions was performed by acquiring images with opposing read-out directions and consequently opposing distortions. The applicator shift can be determined by rigidly matching these images. Clinically, T2W-TSE-images are used for this purpose. For pre-clinical tests, EPI-sequences with narrow read-out bandwidth (19.5–47.5Hz), consequently large distortions, were added to the set of clinical MRsequences. To quantify deformations of the Utrecht Interstitial CT/MR applicator (Elekta Brachytherapy) on a Philips Ingenia 3T MRI, pre-clinical tests were performed in a phantom with the applicator in water, followed by clinical validation. Results: Deformations observed in the narrow bandwidth EPI-images were well predicted using the frequency-shift, the latter giving an overestimation up to 30%/up to 1 voxel. For clinically applied MR-sequences distortions were well below the voxel size. In patient setup distortions determined from the frequency-shift map were at sub-voxel level (<0.7mm). Using T2W-images larger distortions were found (1–2mm). This discrepancy was caused by patient movement between/during acquisition of the T2W-images with opposing read-out directions. Conclusion: Phantom experiments demonstrated the feasibility of a clinical procedure for quantification of MR-image distortions for any MR-sequence. In a clinical set-up the distortions from a Utrecht interstitial CT/MR applicator are sub-voxel level. This work was partially funded by Elekta Brachytherpy.

60 APPLIED LIFE SCIENCES↗