A Compact Airborne High Spectral Resolution Lidar for Observations of Aerosol and Cloud Optical Properties

We are in the process of developing a nadir-viewing, aircraft-based high spectral resolution lidar (HSRL) at NASA Langley Research Center. The system is designed to measure backscatter and extinction of aerosols and tenuous clouds. The primary uses of the instrument will be to validate spaceborne aerosol and cloud observations, carry out regional process studies, and assess the predictions of chemical transport models. In this paper, we provide an overview of the instrument design and present the results of simulations showing the instrument's capability to accurately measure extinction and extinction-to-backscatter ratio.

Hostetler, Chris A.↗

Progress Toward a Compact 0.05 K Magnet Refrigerator Operating from 10 K

Much of the most interesting information regarding our universe is hidden in the sub-millimeter, infrared, and x-rays bands of the spectrum, to which our atmosphere is largely opaque. Thus, missions exploring these bands are a very important part of NASA s Space Science program. Coincidentally, the most sensitive detectors in these spectral regions operate at extremely low temperatures, typically 0.05 - 0.10 K. Generally these temperatures will be achieved using magnetic refrigerators, also know as Adiabatic Demagnetization Refrigerators, or ADRs. Current ADRs, such as the one used in the XRS-II instrument on the Astro-E2 satellite, use a single-stage to cool detectors from 1.3 K to 0.06 K. The ADR is designed so that it can absorb the heat on the detector stage for at least 24 hours before it must stop, warm up to the helium bath temperature (1.3 K), and dump the accumulated heat. Future detector arrays will be much larger and will have higher heat dissipation. Furthermore, future missions will use mechanical cryocoolers to provide upper stage cooling, but they can only reach 4 - 10 K. Trying to scale heavy (-15 kg) single stage ADRs up to the higher heat loads and higher heat rejection temperatures required leads to unacceptably large systems. The GSFC Cryogenics Branch has developed the Continuous ADR (CADR) to solve this problem. The CADR consists of a series of ADR stages that sequentially pass heat from the load up to the high temperature heat sink. The stage connected to the load remains at a constant temperature. The continuous stage effectively decouples detector operation from ADR operation, allowing the ADR stages to be cycled much more rapidly. Rapid cycling leads to higher cooling power density. The cascading, multistage arrangement allows the magnetic refrigerant of each stage to be optimized for its own temperature swing. In the past year, we have made good progress toward a 0.05 to 10K system. A four-stage system that operates from 4.2 K was demonstrated. Magnetic shielding was added to eliminate inter-stage coupling. Improvements were made to superconducting and passive gas-gap heat switches. A second type of passive gas gap switch, one meant for use at higher temperature, was demonstrated. The presentation will focus primarily on these recent design improvements, and on the challenges that remain on the progress toward a system that will operate from 10 K or higher.

Canavan, Edgar↗

Compact Laser-Based Sensors for Monitoring and Control of Gas Turbine Combustors

Research is reported on the development of sensors for gas turbine combustor applications that measure real-time gas temperature using near-infrared water vapor absorption and concentration in the combustor exhaust of trace quantities of pollutant NO and CO using mid-infrared absorption. Gas temperature is extracted from the relative absorption strength of two near-infrared transitions of water vapor. From a survey of the water vapor absorption spectrum, two overtone transitions near 1800 nm were selected that can be rapidly scanned in wavelength by injection current tuning a single DFB diode laser. From the ratio of the absorbances on these selected transitions, a path-integrated gas temperature can be extracted in near-real time. Demonstration measurements with this new temperature sensor showed that combustor instabilities could be identified in the power spectrum of the temperature versus time record. These results suggest that this strategy is extremely promising for gas turbine combustor control applications. Measurements of the concentration of NO and CO in the combustor exhaust are demonstrated with mid-infrared transitions using thermo-electrically cooled, quantum cascade lasers operating near 5.26 and 4.62 microns respectively. Measurements of NO are performed in an insulated exhaust duct of a C2H4-air flame at temperatures of approximately 600 K. CO measurements are performed above a rich H2-air flame seeded with CO2 and cooled with excess N2 to 1150 K. Using a balanced ratiometric detection technique a sensitivity of 0.36 ppm-m was achieved for NO and 0.21 ppm-m for CO. Comparisons between measured and predicted water-vapor and CO2 interference are discussed. The mid-infrared laser quantum cascade laser technology is in its infancy; however, these measurements demonstrate the potential for pollutant monitoring in exhaust gases with mid-IR laser absorption.

Hanson, Ronald K.↗

A Compact, Soft-Switching DC-DC Converter for Electric Propulsion

A hybrid, soft-switching, DC-DC converter has been developed with superior soft switching characteristics, high efficiency, and low electro-magnetic interference. This hybrid topology is comprised of an uncontrolled bridge operating at full pulse-width, and a controlled section operating as a conventional phase modulated converter. The unique topology is able to maintain zero voltage switching down to no load operating conditions. A breadboard prototype was developed and tested to demonstrate the benefits of the topology. Improvements were then made to reduce the size of passive components and increase efficiency in preparation for packaging. A packaged prototype was then designed and built, and several innovative packaging techniques are presented. Performance test data is presented that reveals deficiencies in the design of the power transformer. A simple redesign of the transformer windings eliminated the deficiency. Future plans to improve the converter and packaging design are presented along with several conclusions.

Button, Robert↗

Investigations into Gravitational Wave Emission from Compact Body Inspiral Into Massive Black Holes

Much of the grant's support (and associated time) was used in developmental activity, building infrastructure for the core of the work that the grant supports. Though infrastructure development was the bulk of the activity supported this year, important progress was made in research as well. The two most important "infrastructure" items were in computing hardware and personnel. Research activities were primarily focused on improving and extending. Hughes' Teukolsky-equation-based gravitational-wave generator. Several improvements have been incorporated into this generator.

Hughes, Scott A.↗

Development and Ground Testing of a Compactly Stowed Scalable Inflatably Deployed Solar Sail

This paper discusses the solar sail design and outlines the interim accomplishments to advance the technology readiness level (TRL) of the subsystem from 3 toward a technology readiness level of 6 in 2005. Under Phase II of the program many component test articles have been fabricated and tested successfully. Most notably an unprecedented section of the conically deployed rigidizable sail support beam, the heart of the inflatable rigidizable structure, has been deployed and tested in the NASA Goddard thermal vacuum chamber with good results. The development testing validated the beam packaging and deployment. The inflatable conically deployed, Sub Tg rigidizable beam technology is now in the TRL 5-6 range. The fabricated masses and structural test results of our beam components have met predictions and no changes to the mass estimates or design assumptions have been identified adding great credibility to the design. Several quadrants of the Mylar sail have also been fabricated and successfully deployed validating our design, manufacturing, and deployment techniques.

Lichodziejewski, David↗

A XMM Survey for Compact Objects in Supernova Remnants

The goal of the project is to identify candidate neutron stars in Galactic supernova remnants (SNRs) through their X-ray emission. With XMM we observed the SNRs and typically find 10 - 50 X-ray sources. Almost all are either background galaxies or foreground stars. Therefore we must also pursue detailed optical/infrared follow-up observations to find counterparts for these X-ray sources and classify them. At the depth of the XMM observations, practically all confusing X-ray sources should have identifiable optical/IR counterparts. We have done a preliminary analysis of the XMM data and identified likely counterparts to the X-ray sources from available surveys(DSS, 2MASS). We then obtained wide-field optical/IR data from Palomar to get counterparts for the remaining sources. This analysis is underway: while often a single bright source is in the XMM error circle and can be considered a counterpart, in a number of cases we must do more detailed studies and evaluate several fainter optical/lR sources. We hope to have the final analysis of the XMM + Palomar data done this Fall. It is possible that additional, deeper optical/IR data may be necessary. We expect to publish our results by the end of this year.

Kulkarni, Shrinivas R.↗

Validation of a High-Order Prefactored Compact Code on Nonlinear Flows with Complex Geometries

A finite-difference time domain solution of the airfoil gust problem is obtained using a high-accuracy nonlinear computational aeroacoustics code. For computational efficiency, the equations are cast in chain-rule curvilinear form, and a structured multiblock solver is used in parallel. In order to fully investigate the performance of this solver, a test matrix of eight problems are computed (two airfoil geometries, two gust frequencies, and two gust configurations). These results are compared to solutions obtained by the GUST3D frequency-domain solver both on the airfoil surface and in the far field. Grid density and domain size studies are included.

Hixon, R.↗

Microelectrical Mechanical Systems Flow Control Used to Manage Engine Face Distortion in Compact Inlet Systems

Turbofan engine-face flow distortion is one of the most troublesome and least understood problems for designers of modern engine inlet systems. One concern is that there are numerous sources of flow-field distortion that are ingested by the inlet or generated within the inlet duct itself. Among these are: (1) flow separation at the cowl lip during in-flight maneuvering, (2) flow separation on the compression surfaces due to shock-wave/boundary layer interactions, (3) spillage of the fuselage boundary layer into the inlet duct, (4) ingestion of aircraft vortices and wakes emanating from upstream disturbances, and (5) strong secondary flow gradients and flow separation induced by wall curvature within the inlet duct itself. Most developing aircraft (including the B70, F-111, F-14, Mig-25, Tornado, and Airbus A300) have experienced one or more of these types of problems, particularly at high Mach numbers and/or extreme maneuver conditions when flow distortion at the engine face exceeded the allowable limits of the engine.

Anderson, Bernhard H.↗

Compact FUV camera concept for Space Weather applications

Far ultraviolet (FUV) images of Earth from space have proven invaluable in revealing contextual phenomena associated with space weather in the high latitude auroral regions and, more recently with TIMED and IMAGE in the mid and equatorial regions. Images of this nature can be used to investigate compelling questions associated with the interaction of the ionosphere/mesosphere-magnetosphere-solar wind. Three such questions are: 1. What are the critical time and spatial scales that determine the coupling between the magnetosphere and ionosphere? 2. What are the sources and characteristics of ionospheric variability? 3. How does the configuration of the magnetosphere change as a function of internal boundary conditions established by the mesosphere/ionosphere and the external driving conditions of the solar wind? Observations that lead to quantitative analyses are required to significantly advance the state of knowledge with regard to the affects of space weather and the interaction between and within these regions of Geospace. Current available image data sets are sufficient for qualitative analysis and morphological investigations, and while quantitative analyses are possible, they are difficult and limited to few events at best. In order to qualitatively access the time, spatial, and causal phenomena on global scales, simultaneous images of various FUV emissions with a combination of better spatial, temporal and spectral resolution and sensitivity than currently available is required. We present an instrument concept that is being developed to improve the spatial, temporal and spectral resolution and sensitivity needed to perform the quantitative analysis that enable significant advancement in our understanding of the impact of space weather on Geospace. The approach is to use the self-filtering concept that combines the imaging and filtering functions and thus reduces the size of the 4-mirror off-axis optical system. The optical and filter design will de described and results of preliminary breadboard tests will be provided.

Spann, James↗

Compact Micro-Imaging Spectrometer (CMIS): Investigation of Imaging Spectroscopy and Its Application to Mars Geology and Astrobiology

Future missions to Mars will attempt to answer questions about Mars' geological and biological history. The goal of the CMIS project is to design, construct, and test a capable, multi-spectral micro-imaging spectrometer use in such missions. A breadboard instrument has been constructed with a micro-imaging camera and Several multi-wavelength LED illumination rings. Test samples have been chosen for their interest to spectroscopists, geologists and astrobiologists. Preliminary analysis has demonstrated the advantages of isotropic illumination and micro-imaging spectroscopy over spot spectroscopy.

Staten, Paul W.↗

Evidence for a Binary Companion to the Enigmatic Compact Central Object 1E 1207.4-5209

Located in the supernova remnant G296.5+10.0, 1E 1207.4-5209 is a 0.424 s period X-ray pulsar that exhibits strong absorption lines in its energy spectrum. The physical origin of the spectral features in 1E 1207.4-5209 and more generally, the absence of similar features in other radio-quiet neutron stars remains a mystery. Another, possibly related, anomalous property of 1E 1207.4-5209 is its non-monotonic spin frequency evolution. Zavlin, Pavlov & Sanwal(2004) proposed that the irregular spin-down was caused by either (i) frequent, recurrent glitches, (ii) the presence of a fall-back disk or (iii) a binary companion. Here, we report on a sequence of seven XMM-Newton observations of 1E 1207.4-5209 performed during a 40 day window between 2005 June 22 and July 3 1. Due to unanticipated phase noise, we identified three statistically-acceptable phase-coherent timing solutions with frequency time derivatives of +0.9, -2.6, and +1.6 x 10-12 Hz/s (listed in descending order of significance). We concluded that the local frequency derivative during our XMM-Newton observing campaign differs from the long-term spin-down rate by more than an order of magnitude. This measurement strongly supports the binary interpretation for the observed spin irregularities in 1E 1207.4-5209. We identified a family of orbital solutions that are consistent with our phase-connected solution as well as all archival data. We will discuss possible orbital solutions, prospects for constraining binary parameters with future observations, and consequences for the nature of 1E 1207.4-5209.

Woods, P. M.↗

Identification Of Cells With A Compact Microscope Imaging System With Intelligent Controls

A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking mic?oscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to autofocus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

McDowell, Mark↗

High-Resolution Large Field-of-View FUV Compact Camera

The need for a high resolution camera with a large field of view and capable to image dim emissions in the far-ultraviolet is driven by the widely varying intensities of FUV emissions and spatial/temporal scales of phenomena of interest in the Earth% ionosphere. In this paper, the concept of a camera is presented that is designed to achieve these goals in a lightweight package with sufficient visible light rejection to be useful for dayside and nightside emissions. The camera employs the concept of self-filtering to achieve good spectral resolution tuned to specific wavelengths. The large field of view is sufficient to image the Earth's disk at Geosynchronous altitudes and capable of a spatial resolution of >20 km. The optics and filters are emphasized.

Spann, James F.↗

Ultra-Compact Neuroprocessor for Automotive Diagnostic and Control

Demands on the performance of vehicle control and diagnostic systems are steadily increasing as a consequence of stiff global competition and government mandates. In the United States, light trucks and passenger cars are required both to meet strict emission standards and to perform continuous diagnostics of all emissions systems operating in the vehicle.

Neuroprocessor automotive diagnostics↗