Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

NuSTAR Observations of Four Mid-IR-Selected Dual AGN Candidates in Galaxy Mergers

Mergers of galaxies are a ubiquitous phenomenon in the universe and represent a natural consequence of the “bottom-up” mass accumulation and galaxy evolution cosmological paradigm. It is generally accepted that the peak of active galactic nucleus (AGN) accretion activity occurs at nuclear separations of ≲10 kpc for major mergers. Here we present new NuSTAR and XMM-Newton observations for a subsample of mid-IR preselected dual AGN candidates in an effort to better constrain the column densities along the line of sight (LOS) for each system. Only one dual AGN candidate, J0841+0101, is detected as a single, unresolved source in the XMMNewton and NuSTAR imaging, while the remaining three dual AGN candidates, J0122+0100, J1221+1137, and J1306+0735, are not detected with NuSTAR; if these nondetections are due to obscuration alone, these systems are consistent with being absorbed by column densities of log ( N H /cm −2 ) ≽ 24.9, 24.6, and 24.3, which are roughly consistent with previously inferred column densities in these merging systems. In the case of J0841+0101, the analysis of the 0.3–30 keV spectra reveal an LOS column density of N H ≳ 10 24 cm −2 , significantly larger than the column densities previously reported for this system and demonstrating the importance of the higher signal-to-noise ratio XMM-Newton spectra and access to the >10 keV energies via NuSTAR. Though it is unclear if J0841+0101 truly hosts a dual AGN, these results are in agreement with the high obscuring columns expected in AGNs in late-stage mergers.

AGN host galaxies↗

Semiconductor radiation detector

A semiconductor detector for ionizing electromagnetic radiation, neutrons, and energetic charged particles. The detecting element is comprised of a compound having the composition I-III-VI.sub.2 or II-IV-V.sub.2 where the "I" component is from column 1A or 1B of the periodic table, the "II" component is from column 2B, the "III" component is from column 3A, the "IV" component is from column 4A, the "V" component is from column 5A, and the "VI" component is from column 6A. The detecting element detects ionizing radiation by generating a signal proportional to the energy deposited in the element, and detects neutrons by virtue of the ionizing radiation emitted by one or more of the constituent materials subsequent to capture. The detector may contain more than one neutron-sensitive component.

Bell, Zane W↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Apparatus and method for recovering an amine solvent from an acid gas stream

A method and apparatus are provided for recovering an amine solvent from an acid gas stream. The apparatus includes a water wash recovery column, a nozzle for spraying water wash and an amine nucleation agent into the water wash recovery column and an inlet port for introducing acid gas into the water wash recovery column adjacent the lower end thereof. The method includes the steps of treating the acid gas stream in the water wash recovery column with a counter-current flow of water wash in an amine nucleation agent, discharging treated acid gas from an upper end of the water wash recovery column and collecting water wash, amine nucleation agent and entrained amine solvent from the acid gas stream and a sump at a lower end of the water wash recovery column.

Irvin, Bradley David↗

Evaluation of the Effects of Microbes on Autunite Dissolution and the Spectral Induced Polarization Response in Hanford Vadose Zone Sediment - 18440

As a result of the U.S. nuclear weapons program during the second World War and throughout the Cold War, there now exists a significant amount of uranium contamination at the U.S. Department of Energy Hanford site located in Washington State. Much of this contamination is in the form of mobile uranyl carbonates species within the vadose zone, which at Hanford varies up to 100 m thick in the Central Plateau. In-situ immobilization of mobile uranium via injections of a soluble sodium tripolyphosphate amendment may prove effective in the formation of low-solubility uranyl phosphate solid phases, autunite. However, the injected polyphosphate undergoes hydrolysis in aqueous solutions to form orthophosphate, which serves as a readily available nutrient for the various microorganisms in the sediment. Sediment-filled column experiments conducted under saturated oxygen restricted conditions using a geophysical technique known as spectral induced polarization (SIP) have shown the impact of microbes on the dissolution of synthetic autunite. Two sets of experiments were conducted using test columns. Each experiment had a pair of columns inoculated with microbes (with a glucose solution acting as a nutrient source) which were monitored using SIP in conjunction with regular sampling of pore-water. Columns were built with two silver/silver chloride (Ag/AgCl) coiled current electrodes at either end and four Ag potential electrodes along the side, which allowed the measurement of three distinct points along the length of the column. SIP measures phase which is the time delay between an injected current and measured voltage, in this case measured in radians. Three sampling ports were added to correspond with the geophysical measurements. Pore-water samples taken over the course of the experiment were analyzed for dissolved elements including uranium, iron, phosphorous, calcium, and magnesium. SIP results were plotted over time in order to determine correlations between changes in electrical phase and changes in pore-water chemistry. It was determined that changes in the phase and bulk resistivity detected with SIP corresponded to changes in the pore-water chemistry due to the growth of microbes. The first experiment ran for five months and had measurements done once a week, the second only ran one month but had measurements taken five times a week in order to understand initial changes in column chemistry in greater detail. SIP may be an effective way to remotely track changes indicative of bacterial activities on the surrounding environment. This method has the potential for field application at a larger scale for the purpose of tracking microbe growth in response to tripolyphosphate amendment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adsorption of Iodine and Tritium from UNF Reprocessing Off-Gas Streams

The need to control emissions of the gaseous radionuclides to the air during nuclear fuel recycling is widely recognized. Gaseous radionuclides can partition to off-gas streams emanating from the various individual processes used in the recycle plant, such as from the mechanical head end (shear), tritium pretreatment, fuel dissolver, vessel vents, cell ventilation, and conversion operations. In traditional recycle plants, the bulk of the four primary volatile fission products (i.e., {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I) is released in the head-end processes, for example, the dissolution process. The usual off-gas treatment sequence of operations targets removal of tritium (as {sup 3}HHO), iodine, carbon (as {sup 14}CO{sub 2}), and the noble gases, in that order. Water and iodine are captured first because the other species are relatively unimpeded by the sorbents used for water and iodine, so they flow downstream to additional treatment processes. Water and iodine do react with one another, and many techniques used to collect one of these species also collect some fraction of the other. It is quite desirable to sequester the iodine and water separately because the tritiated water may be disposed of as a low level waste. If not cleanly separated, contamination of the low-level waste by iodine may elevate its classification to high-level waste and result in greater costs for disposal. The proposed sorption sequence was tested in the laboratory. Use of a second column of AgZ permits the detection of breakthrough from the primary AgZ column while protecting the downstream 3AMS column from collecting iodine. (This arrangement is equivalent to enabling intra-column sampling of the primary column.) Neutron activation analysis of the 3AMS revealed that iodine was below, or at, the level of detection. The results successfully demonstrated that iodine can be sequestered in the AgZ while the water is collected free of iodine in the 3AMS column. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using the Diffusion Equation to Predict CST Resin Breakthroughs - 19051

The crystalline silicotitanate, CST, resin manufactured by UOP Honeywell is well-suited for single-use decontamination of caustic liquid wastes at Hanford and Savannah River Sites. There are many measurements of column loading and breakthrough for CST resin decontamination of Cs-137 in various Hanford and SRS waste simulants. Such measurements provide a very good basis for estimating CST resin demand and these more refined predictions make the CST column loading as efficient as possible given the very expensive CST resin. Although there are a variety of tools for predicting chromatographic resin column performance, [1-4], there is a particularly useful method that is suitable as a simple spreadsheet model [4]. This spreadsheet model is an analytical error function for the mass transfer zone (mtz) diffusion width in resin columns and is well-suited for resin breakthrough and column loading. This paper describes just such an error function spreadsheet model and how well the error function agrees with more traditional models and fits the observed small scale breakthrough curves for CST that can then better predict large scale column loading efficiency. The very high sorption of Cs onto CST tends to be slower than that of other lower sorption resins and as a result of the slow CST kinetics, there is also a marked asymmetry in many CST breakthrough curves. The CST breakthrough asymmetry is largely due to the distribution of CST particle sizes because smaller particles sorb much faster than larger particles. It is then the smaller particles that determine the leading mtz at a decontamination factor of 1,000 breakthrough and therefore the decontamination efficiency for a given loading. The larger CST particles correspondingly determine the tailing mtz width and therefore the overall loading efficiency and it is important to model both leading and tailing mtz widths to best optimize CST for a particular Cs-137 decontamination application. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TCCR Operational Summary and Optimization for Tank 9 Processing - 20314

Savannah River Remediation (SRR) manages and operates the liquid waste facilities at Savannah River Site (SRS) for the Department of Energy (DOE). Stored liquid waste is a complex mixture of insoluble solids (sludge) and soluble salts in an alkaline solution. SRR has deployed the Tank Closure Cesium Removal (TCCR) system, a tank-side ion exchange process, to remove radioactive cesium from salt waste and enable onsite disposal of the resulting decontaminated salt solution as low-level waste at the Saltstone facilities. The TCCR system consists of two prefilters, four ion exchange (IX) columns, one resin trap, and a ventilation system. The IX process uses a form of inorganic crystalline silicotitanate (CST), which has a high affinity for cesium and other alkali metals, strontium, and actinides. This process is currently deployed utilizing salt feed from Tank 10, with future plans to dissolve solid salt in Tank 9 and transfer the salt solution to Tank 10 for processing through TCCR. The feed for TCCR must be created from salt-cake in Tank 10 through a dissolution process. Once enough salt has been dissolved, a qualification process is entered. This process characterizes the feed and ensures the cesium loading on the columns will not cause boiling of waste within the columns during or after processing. Once the batch has been qualified, salt waste is fed to the TCCR system through a transfer pump in the center of the tank. The waste is filtered through a set of two shielded, dead-end prefilters that prevent solids buildup in the columns. The filtered salt solution then travels to the shielded IX columns, which can be operated individually or in series, where the cesium is sorbed on the CST media. The decontaminated salt solution (DSS) then travels through a resin trap and out of the module to Tank 11. TCCR has successfully processed approximately 795,000 L of Tank 10H radioactive salt waste over two batches to date. There has not yet been a system induced shutdown. The prefilters performed as expected with only minor degradation in recovery of differential pressure after a backflush sequence. The time between backflushes decreased as each batch reached the end of processing. The hydraulics in the IXCs mostly performed as expected at all flow rates, except for one IXC that will be further investigated during Batch 3 processing. The TCCR system has shown some opportunities for more efficient processing during the length of the demonstration so far. For future processing of material from Tank 9H through Tank 10H and the TCCR unit, TCCR 1A will implement changes to the prefilters and the IXCs. The prefilters will have an increased surface area and a new filter media in an effort to increase time between filter swaps and improve backwashing cleaning capability. The IXCs will have a reduced diameter to allow for increased heat transfer out of the column and increased loading of Cs-137. Additionally, a new form of CST with an increased kinetic performance is being investigated for use during TCCR 1A operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mass Transport within Soils

Contaminants in soil can impact human health and the environment through a complex web of interactions. Soils exist where the atmosphere, hydrosphere, geosphere, and biosphere converge. Soil is the thin outer zone of the earth's crust that supports rooted plants and is the product of climate and living organisms acting on rock. A true soil is a mixture of air, water, mineral, and organic components. The relative proportions of these components determine the value of the soil for agricultural and for other human uses. These proportions also determine, to a large extent, how a substance added to soil is transported and/or transformed within the soil (Spositio, 2004). In mass-balance models, soil compartments play a major role, functioning both as reservoirs and as the principal media for transport among air, vegetation, surface water, deeper soil, and ground water (Mackay, 2001). Quantifying the mass transport of chemicals within soil and between soil and atmosphere is important for understanding the role soil plays in controlling fate, transport, and exposure to multimedia pollutants. Soils are characteristically heterogeneous. A trench dug into soil typically reveals several horizontal layers having different colors and textures. As illustrated in Figure 1, these multiple layers are often divided into three major horizons: (1) the A horizon, which encompasses the root zone and contains a high concentration of organic matter; (2) the B horizon, which is unsaturated, lies below the roots of most plants, and contains a much lower organic carbon content; and (3) the C horizon, which is the unsaturated zone of weathered parent rock consisting of bedrock, alluvial material, glacial material, and/or soil of an earlier geological period. Below these three horizons lies the saturated zone - a zone that encompasses the area below ground surface in which all interconnected openings within the geologic media are completely filled with water. Similarly to the unsaturated zone with three major horizons, the saturated zone can be further divided into other zones based on hydraulic and geologic conditions. Wetland soils are a special and important class in which near-saturation conditions exist most of the time. When a contaminant is added to or formed in a soil column, there are several mechanisms by which it can be dispersed, transported out of the soil column to other parts of the environment, destroyed, or transformed into some other species. Thus, to evaluate or manage any contaminant introduced to the soil column, one must determine whether and how that substance will (1) remain or accumulate within the soil column, (2) be transported by dispersion or advection within the soil column, (3) be physically, chemically, or biologically transformed within the soil (i.e., by hydrolysis, oxidation, etc.), or (4) be transported out of the soil column to another part of the environment through a cross-media transfer (i.e., volatilization, runoff, ground water infiltration, etc.). These competing processes impact the fate of physical, chemical, or biological contaminants found in soils. In order to capture these mechanisms in mass transfer models, we must develop mass-transfer coefficients (MTCs) specific to soil layers. That is the goal of this chapter. The reader is referred to other chapters in this Handbook that address related transport processes, namely Chapter 13 on bioturbation, Chapter 15 on transport in near-surface geological formations, and Chapter 17 on soil resuspention. This chapter addresses the following issues: the nature of soil pollution, composition of soil, transport processes and transport parameters in soil, transformation processes in soil, mass-balance models, and MTCs in soils. We show that to address vertical heterogeneity in soils in is necessary to define a characteristic scaling depth and use this to establish process-based expressions for soil MTCs. The scaling depth in soil and the corresponding MTCs depend strongly on (1) the composition of the soil and physical state of the soil, (2) the chemical and physical properties of the substance of interest, and (3) transformation rates in soil. Our particular focus is on approaches for constructing soil-transport algorithms and soil-transport parameters for incorporation within multimedia fate models. We show how MTC's can be developed to construct a simple two-compartment air-soil system. We then demonstrate how a multi-layer-box-model approach for soil-mass balance converges to the exact analytical solution for concentration and mass balance. Finally, we demonstrate and evaluate the performance of the algorithms in a model with applications to the specimen chemicals benzene, hexachlorobenzene, lindane gammahexachlorocyclohexane, benzo(a)pyrene, nickel, and copper.

54 ENVIRONMENTAL SCIENCES↗

Exact peak compression factor in linear gradient elution I. Theory

The only existing expression for the peak compression factor in linear gradient elution chromatography assumes that the linear-solvent-strength model (LSSM) applies to the retention of the compound studied, that the column efficiency is independent of the mobile phase composition, and that, during gradient elution, the relative retention factor of a compound inside its band varies linearly with the distance from the band center. Because the retention factors of many analytes in reversed-phase liquid chromatography do not rigorously follow the LSSM, we extend the theoretical approach of Poppe et al. to the prediction of peak compression factors in linear gradient elution chromatography for any retention model, when column efficiency varies with the mobile phase composition. Only the contribution of the chromatographic column to the peak compression was taken into account, the contribution of the dwell volume being neglected. A second restriction is the linearity of the relative retention factor as a function of the position along the band width inside the column. These constraints could be the sources for the difference observed between experimental and theoretical values of peak compression factors. When the retention factor varies steeply with the mobile phase composition, such as with proteins or large peptides in RP-HPLC, it is found that the thermodynamic compression term, which tends to sharpen the peak, is coupled with the column dispersion term, which tends to broaden the peak. This coupling term acts as an apparent dispersion term, contributing to broaden the peak. This result is consistent with the measurements of peak compression factors found in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reactive transport of uranium in fractured crystalline rock: Upscaling in time and distance

In this study, batch adsorption and breakthrough column experiments were conducted to evaluate uranium transport through altered material that fills fractures in a granite rock system at the Grimsel Test Site in Switzerland at pH 6.9 and 7.9. The role of adsorption and desorption kinetics was evaluated with reactive transport modeling by comparing one-, two-, and three-site models. Emphasis was placed on describing long desorption tails that are important for upscaling in time and distance. The effect of increasing pH in injection solutions was also evaluated. For pH 6.9, a three-site model with forward rate constants between 0.07 and 0.8 ml g –1 h –1 , reverse rate constants between 0.001 and 0.06 h –1 , and site densities of 1.3, 0.104, and 0.026 μmol g –1 for ‘weak/fast’, ‘strong/slow’, and ‘very strong/very slow’ sites provided the best fits. For pH 7.9, a three-site model with forward rate constants between 0.05 and 0.8 mL g –1 h –1 , reverse rate constants between 0.001 and 0.6 h –1 , and site densities of 1.3, 0.039, and 0.013 μmol g –1 for a ‘weak/fast’, ‘strong/slow’, and ‘very strong/very slow’ sites provided the best fits. Column retardation coefficients (R d ) were 80 for pH 6.9 and 10.3 for pH 7.9. Model parameters determined from the batch and column experiments were used in 50 year large-scale simulations for continuous and pulse injections and indicated that a three-site model is necessary at pH 6.9, although a K d -type equilibrium partition model with one-site was adequate for large scale predictions at pH 7.9. Batch experiments were useful for predicting early breakthrough times in the columns while column experiments helped differentiate the relative importance of sorption sites and desorption rate constants on transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of the temperature bulge in CO{sub 2} absorption from flue gas by aqueous monoethanolamine

Pilot plant data for CO{sub 2} absorption by aqueous monoethanolamine (MEA) were simulated with the RateSep model and a dynamic model implemented in gPROMS. RateSep is the second generation rate-based model in AspenPlus. Because of the phenomena of combined absorption and water vaporization and condensation, a temperature bulge will appear in the absorber. The present study addresses the effects of column parameters including L/G, heat of absorption, height of packing, and flue gas CO{sub 2} concentration. The temperature bulge is quantified by its magnitude and location and how these parameters affect the absorber performance. When the bulge is located in the top or bottom of the column, the magnitude is close to the limiting values of the temperature in the liquid and gas, respectively, leaving the column. The magnitude is maximized when the bulge is located approximately in the middle of the column. The absorber performance seems to be independent of the bulge location when it is located in the top or in the bottom of the column, while it might affect the performance when located in the middle.

01 COAL, LIGNITE, AND PEAT↗

The unique chemistry of Eastern Mediterranean water masses selects for distinct microbial communities by depth

The waters of the Eastern Mediterranean are characterized by unique physical and chemical properties within separate water masses occupying different depths. Distinct water masses are present throughout the oceans, which drive thermohaline circulation. These water masses may contain specific microbial assemblages. The goal of this study was to examine the effect of physical and geological phenomena on the microbial community of the Eastern Mediterranean water column. Chemical measurements were combined with phospholipid fatty acid (PLFA) analysis and high-throughput 16S rRNA sequencing to characterize the microbial community in the water column at five sites. We demonstrate that the chemistry and microbial community of the water column were stratified into three distinct water masses. The salinity and nutrient concentrations vary between these water masses. Nutrient concentrations increased with depth, and salinity was highest in the intermediate water mass. Our PLFA analysis indicated different lipid classes were abundant in each water mass, suggesting that distinct groups of microbes inhabit these water masses. 16S rRNA gene sequencing confirmed the presence of distinct microbial communities in each water mass. Taxa involved in autotrophic nitrogen cycling were enriched in the intermediate water mass suggesting that microbes in this water mass may be important to the nitrogen cycle of the Eastern Mediterranean. The Eastern Mediterranean also contains numerous active hydrocarbon seeps. We sampled above the North Alex Mud Volcano, in order to test the effect of these geological features on the microbial community in the adjacent water column. The community in the waters overlaying the mud volcano was distinct from other communities collected at similar depths and was enriched in known hydrocarbon degrading taxa. Furthermore, our results demonstrate that physical phenomena such stratification as well as geological phenomena such as mud volcanoes strongly affect microbial community structure in the Eastern Mediterranean water column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the Thickness of Perennial Ice Covers on Stratified Lakes of the Taylor Valley, Antarctica

A one-dimensional ice cover model was developed to predict and constrain drivers of long term ice thickness trends in chemically stratified lakes of Taylor Valley, Antarctica. The model is driven by surface radiative heat fluxes and heat fluxes from the underlying water column. The model successfully reproduced 16 years (between 1996 and 2012) of ice thickness changes for west lobe of Lake Bonney (average ice thickness = 3.53 m; RMSE = 0.09 m, n = 118) and Lake Fryxell (average ice thickness = 4.22 m; RMSE = 0.21 m, n = 128). Long-term ice thickness trends require coupling with the thermal structure of the water column. The heat stored within the temperature maximum of lakes exceeding a liquid water column depth of 20 m can either impede or facilitate ice thickness change depending on the predominant climatic trend (temperature cooling or warming). As such, shallow (< 20 m deep water columns) perennially ice-covered lakes without deep temperature maxima are more sensitive indicators of climate change. The long-term ice thickness trends are a result of surface energy flux and heat flux from the deep temperature maximum in the water column, the latter of which results from absorbed solar radiation.

heat fluxes from the underlying water column↗

Intercomparison of model simulations of mixed-phase clouds observed during the ARM Mixed-Phase Arctic Cloud Experiment. I: Single layer cloud

Results are presented from an intercomparison of single-column and cloud-resolving model simulations of a cold-air outbreak mixed-phase stratocumulus cloud observed during the ARM Mixed-Phase Arctic Cloud Experiment. The observed cloud occurred in a well-mixed boundary layer with a cloud top temperature of –15°C. While the cloud was water dominated, ice precipitation appears to have lowered the liquid water path to about 2/3 of the adiabatic value. The simulations, which were performed by seventeen single column and nine cloud-resolving models, generally underestimate the liquid water path with the median single-column and cloud-resolving model liquid water path a factor of 3 smaller than observed. While the simulated ice water path is in general agreement with the observed values, results from a sensitivity study in which models removed ice microphysics indicate that in many models the interaction between liquid and ice phase microphysics is responsible for the strong model underestimate of liquid water path. Although no single factor is found to lead to a good simulation, these results emphasize the need for care in the model treatment of mixed-phase microphysics. This case study, which has been well observed from both aircraft and ground-based remote sensors, could be benchmark for model simulations of mixed-phase clouds.

54 ENVIRONMENTAL SCIENCES↗

“Age” Determination of Irradiated Materials Utilizing Inductively Coupled Plasma Mass Spectrometric (ICP-MS) Detection

A gas pressurized extraction chromatography (GPEC) system has been developed to perform elemental separations on radioactive samples to determine total and isotopic compositions of Cs and Ba from an irradiated salt sample, fuel sample and two sealed radiation sources. The separation is necessary to remove isobaric interferences in the determination of 137Cs, 135Cs, 137Ba, 135Ba, which are used to determine the age of a sample from radioactive decay or purification. The micro-column extraction chromatography system employs compressed nitrogen to move liquid through the system, compared to gravity or pumped liquids that are typically used for separations. The use of compressed gas allows for accurate and precise recovery of all liquids put into the chromatography system, enabling very accurate dilutions. The use of a small analytical column permits the use of very small amounts of liquids to be used. As a benefit, the amount of radiological waste that is generated in the separation process is minimized. For this work, a commercially available Sr-Resin™ was used to perform the separation for the above mentioned analytes. The column consists of a 7 inch piece of 1/16 in. O.D. x 0.030 in I.D. Teflon™ tubing having an internal volume of 81 µL. To this column, 49 mg of resin was added. The columns are re-usable after regeneration with 3 M HNO3. All samples were separated using batch collection, although real time analysis is possible with the current experimental design. A 1 % acetic acid solution was determined to be the best extractant for Ba. A flow rate of 0.1 mL/min was determined to be optimal for the separation of Ba. Complete recovery of the Cs and Ba was achieved, within the systematic error of the experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Soil sealing by algae: An alternative to plastic pond liners for outdoor algal cultivation

Commercial production of algal biofuels is currently limited by high capital costs, particularly costs of synthetic pond liners that minimize seepage of cultivation fluids, salts, and nutrients into the subsurface beneath outdoor algae cultivation facilities. Even some profitable nutraceutical companies bear the high costs of pond liners. However, studies of animal waste holding ponds and aquaculture facilities have shown that underlying soils can effectively “self-seal”, potentially eliminating the need for plastic liners. Here, we explored the potential for self-sealing with algae to provide an alternative to synthetic pond liners in unlined algae cultivation ponds. Laboratory-scale soil column experiments were used to investigate soil clogging by algae, a topic rarely discussed in the literature. Columns composed of fine sand, loamy sand, and loam soil displayed reductions in saturated hydraulic conductivity of the entire soil column of up to two orders of magnitude in response to infiltration by the alga Scenedesmus dimorphus suspended in algal culture nutrient solution at a density of 5 × 10 8 cells L –1 . Scanning electron microscope imaging showed a dense algal layer on the surface of each soil column, thickly coating mineral grains with algal material and filling pore spaces. The algal coating was absent in samples at >3 cm depth in the soil columns, and measurements of chlorophyll content also confirmed that algal cells were mostly confined to the soil surface. In this study, the application of an algal suspension contributed significantly to soil sealing. In conclusion, this new application of biological sealing technology should be studied further to determine its utility and durability as an alternative to plastic liners, perhaps in conjunction with soil compaction to achieve hydraulic conductivities beneath algal production ponds that are protective of groundwater quality.

59 BASIC BIOLOGICAL SCIENCES↗

Lime slurry treatment of soils developing on abandoned coal mine spoil: Linking contaminant transport from the micrometer to pedon-scale

Historical and abandoned coal mine spoil continues to generate acid- and metal(loid)-rich porewaters and represents a geographically large and diffuse non-point source of contamination to local watersheds. A potentially inexpensive approach to treat these materials and soils developing on them is through the application of lime slurries, to neutralize acidity and encourage the (co)precipitation of metal(loids) with Fe(III)-(oxy)hydroxides, and potentially other metal-oxides and/or Ca-bearing phases. Here, the efficacy of this approach was evaluated through parallel field application and laboratory-based flow-through column experiments. The field site is Huff Run sub-watershed 25 located in Tuscarawas County, Ohio and was chosen in part because it was previously classified as one of the most highly AMD-impacted sub-watersheds in the region. Two locations with historical spoil were chosen and suction lysimeters were installed at 25 and 75 cm depth to monitor porewater composition on two sides at the base of each pile. Half of each slope received seven lime slurry treatments from June through October of 2017. A suite of aqueous (ICP-OES, IC, and TOC-L) and solid phase geochemical and mineralogical approaches (quantitative SEM-EDS and synchrotron μ-XRF) were used to determine how composition, texture, morphology, and spatial distribution of mineral coatings differ in pre- and post-lime treated soils, and how that impacts the distribution and transport of trace metal(loid)s. Mine spoil porewater at site 1 was slightly less alkaline (pH ranging from 7.04 to 7.37) than at site 2 (ranging from 7.55 to 7.71), and average electrical conductivity values at site 1 (316–405 μS cm —1 ) were slightly lower than at site 2 (358–464 μS cm —1 ), although differences between the sites were not significant. Porewater pH and electrical conductivity in all lysimeters decreased over the course of the field season but there was no obvious response to lime treatment at either site or any depth. At site 1, both treatment and depth were significant factors affecting Ca, K, Ni, SO 4 2— , and DOC concentrations while only treatment effects were significant for dissolved Al and Cu (p < 0.05). For all soils, there were no trends in metal concentration observed over time although DOC and SO 4 2— decreased over the field season. Pedon-scale changes in metal porewater concentrations in response to treatment were linked to micrometer-scale changes in mineral surface coatings; specifically, higher concentrations of Ca, Fe, Mn, and Zn were observed in the coatings and no changes were observed in Fe redox speciation, whereas total S decreased likely due to oxidation of S in coal fragments. In contrast to the field experiment, the column experiments exhibited a much greater response in effluent composition with respect to lime treatment. The untreated columns had approximately an order of magnitude more H + leached over the course of the experiment (p < 0.001) and resulted in greater Ca, Al, Cu, and DIC leached and less Mn, Zn, and SO 4 2— . Soils treated with the lime slurry in the column experiments exhibited larger and thicker secondary Fe-coatings, including the addition of Fe-sulfates. Despite clear trends in the laboratory-based column experiment where the lime-to-soil ratio was higher, the effects were either muted or undetected in the field pilot project, suggesting that a higher application rate of lime in the field is needed to achieve a similar effect. This work provides evidence that a less alkaline lime slurry could be a practical and inexpensive method of treating coal mine spoil-impacted soils and represents an important step in linking laboratory-based remediation studies to implemented field-based studies.

58 GEOSCIENCES↗