Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “benchmark testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Calculated and Measured Dose Distributions in an Anthropomorphic RANDO Phantom - Paper 105

Patient-specific quality assurance (QA) is a major component of the Intensity Modulated Radiation Therapy (IMRT) clinical process. The objective of this often time-intensive measurement process is to verify that the prescribed dose is accurately delivered to the target volume while sparing surrounding healthy tissue. The IMRT dose distributions can be measured using a wide variety of techniques and measurement devices including film (radiographic and radiochromic), ion chamber arrays, diode arrays, and Electronic Portal Imaging Devices (EPIDs). Of all the available modalities, film is one of the most versatile and most frequently utilized measurement systems. In rotation delivery techniques (such as volume modulated arc therapy and helical tomotherapy), composite dose distributions are obtained by irradiating a test phantom containing dosimeter(s). When film is utilized as the dosimeter, it can be placed in coronal, sagittal, or transverse planes inside the phantom. Because the film is irradiated using the rotational delivery sequence used to treat the patient, the dose given to specific anatomical structures (such as the parotids, spinal cord, bladder, rectum etc...) can be evaluated. Thomas et al (Med Phys 32: 3793-3800) recently reported the results of IMRT verifications for ten patients planned and treated with helical tomotherapy. This study reported that nearly 92% of the film pixels within the analyzed region of interest were within a gamma criterion of 2 mm and 2%. Like most tomotherapy users, Thomas et al used a test phantom made of homogeneous water equivalent material. Heterogeneous phantoms that simulate the different tissue densities in the human body do exist, but are infrequently used for patient-specific IMRT QA. The potential advantage of using heterogeneous phantoms is that the measured dose distributions will more adequately reflect the clinical dose distributions in the patients. The use of homogenous phantoms during IMRT quality assurance can potentially mask errors that arise from limitations in the treatment planning system's modeling of density corrections. The purpose of this study was to evaluate the dosimetric accuracy of a helical tomotherapy system using an anthropomorphic RANDO phantom (The Phantom Laboratory, Salem, NY) for patient-specific QA. The results of this study will allow a benchmark to be established for dosimetric accuracy in heterogeneous materials. Performing patient-specific QA is an integral part of the IMRT patient treatment process. Test phantoms are typically homogeneous, and do test the treatment planning systems ability to account for heterogeneity corrections. In this study, an anthropomorphic RANDO phantom was used to evaluate the doses calculated by a helical tomotherapy system. The dosimetric agreement between calculated and measured was worse than published results in homogenous phantoms, especially for target volumes located in the lung. Further investigation will be needed to determine if these errors are due to film response at heterogeneous tissue interfaces or from actual dose calculation errors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainty Analysis in Critical Experiments of SORA Mockup

A series of static critical experiments were completed from September 1965 to August 1966 at the Oak Ridge National Laboratory Critical Experiments Facility (ORCEF) in support of the design of the Sorgente Rapida Reactor (SORA) under a cooperative agreement between EURATOM and the U.S. Atomic Energy Commission. The SORA which had been proposed by EURATOM and was described by Raievski and Larrimore was designed to be composed of rods of highly enriched uranium alloy latticed, as a fast, reflected, repetitively pulsed reactor to serve as a high-intensity source of neutrons for time-of-flight measurements. More information about the SORA design can be obtained in some references. The critical experiments, not including pulse testing, were performed with a mockup of the SORA reactor differing from the reactor principally in the use of iron in place of the coolant, of iron as reflector, and of uranium metal fuel in place of the alloy. A summary of the experiments for the mockup was compiled in report ORNL- 4263, in June, 1968, then published as a paper in 1969. Based on the available data from papers, reports mentioned above and the logbook, the typical 15 critical experiments were evaluated for experimental uncertainties for further benchmark analysis and inclusion in the ICSBEP Handbook. Through a series of rigorous procedures in analysis of the original experimental measurement data, the dimensions and displacement of individual components, and the isotopic contents, mass, and impurities of the individual components, the experimental uncertainties for the 15 configurations have been evaluated to be 0.00219 ∼0.00229 Δk{sub eff} for 11 configurations in type of the Reference Assembly, 0.00179 ∼0.00189 Δk{sub eff} for 4 configurations in type of the All-Iron Assembly. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recent developments in catalyst-related PEM fuel cell durability

Cost and durability remain the two major barriers to the widespread commercialization of polymer electrolyte membrane fuel cell (PEMFC)-based power systems, especially for the most impactful but challenging fuel cell electric vehicle (FCEV) application. Commercial FCEVs are now on the road; however, their PEMFC systems do not meet the cost targets established by the U.S. Department of Energy, primarily due to the high platinum loading needed on the cathode to achieve the requisite performance and lifetime. Furthermore, while the activities of a number of commercial Pt-based alloy cathode catalysts exceed the beginning-of-life (BOL) targets, these activities, and the overall cathode performance, degrade via a variety of mechanisms described herein. Degradation is mitigated in current FCEVs by utilizing a cathode catalyst with a lower BOL activity (e.g., much lower transition metal alloy content and larger BOL nanoparticle size), necessitating higher catalyst loadings, and through the utilization of system controls that avoid conditions known to exacerbate degradation processes, such as limiting the fuel cell stack voltage range. The design and development of active and robust materials and eliminating the need for vehicle mitigation strategies would greatly simplify the operating system, allowing for greater transient operation, avoiding large hybridization, and curtailing of fuel cell power. Although system mitigation strategies have provided the near-term pathway for FCEV commercialization, material-specific solutions are required to further reduce costs and improve operability and efficiency. Future material developments should focus on stabilization of the electrode structure and minimization of the catalyst particle susceptibility to dissolution caused by oxide formation and reduction over PEMFC cathode-relevant operating potentials plus minimization of support corrosion. Ex situ accelerated stress tests have provided insight into the processes responsible for material and performance degradation and will continue to provide useful information on the relative stability of materials and benchmarks for robust and stable materials-based solutions not requiring system mitigation strategies to achieve adequate lifetime.

25 ENERGY STORAGE↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗

The Role of Snowmelt Temporal Pattern in Flood Estimation for a Small Snow‐Dominated Basin in the Sierra Nevada

Abstract Prior research confirmed the substantial bias from using precipitation‐based intensity‐duration‐frequency curves (PREC‐IDF) in design flood estimates and proposed next‐generation IDF curves (NG‐IDF) that represent both rainfall and snow processes in runoff generation. This study improves the NG‐IDF technology for a snow‐dominated test basin in the Sierra Nevada. A well‐validated physics‐based hydrologic model, the Distributed Hydrology Soil Vegetation Model (DHSVM), is used to continuously simulate snowmelt and streamflow that are used as benchmark data sets to systematically assess the NG‐IDF technology. We find that, for the studied small snow‐dominated basin, the use of standard rainfall hyetographs in the NG‐IDF technology leads to substantial underestimation of design floods. Thus, we propose probabilistic hyetographs that can represent unique patterns of events with different underlying mechanisms. For the test basin where flooding events are generated entirely by snowmelt, we develop a hyetograph that characterizes snowmelt temporal patterns, which greatly improves the performance of NG‐IDF technology in design flood estimates. In contrast to the standard rainfall hyetographs characterized by a symmetrically peaked, bell‐shaped curve, the snowmelt hyetograph displays a more rapid rise (i.e., greater intensity) and a distinct diurnal pattern influenced by solar energy input. The results also show that the uncertainty of hyetography plays an important role in design flood estimation and can have important implications for future flood projections.

54 ENVIRONMENTAL SCIENCES↗

Modeling Multi-Step Organic Reactions: Can Density Functional Theory Deliver Misleading Chemistry?

Many organic reactions are characterized by a complex mechanism with a variety of transition states and intermediates of different chemical natures. Their correct and accurate theoretical characterization critically depends on the accuracy of the computational method used. In this work, we study a complex ambimodal cycloaddition with five transition states, two intermediates, and three products, and we ask whether density functional theory (DFT) can provide a correct description of this type of complex and multifaceted reaction. Our work fills a gap in that most systematic benchmarks of DFT for chemical reactions have considered much simpler reactions. Our results show that many density functionals not only lead to seriously large errors but also differ from one another in predicting whether the reaction is ambimodal. Only a few of the available functionals provide a balanced description of the complex and multifaceted reactions. The parameters varied in the tested functionals are the ingredients, the treatment of medium-range and nonlocal correlation energy, and the inclusion of Hartree–Fock exchange. Furthermore, these results show a clear need for more benchmarks on the mechanisms of large molecules in complex reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Scalable HeterOgeneous Computing (SHOC) Benchmark Suite

Scalable heterogeneous computing systems, which are composed of a mix of compute devices, such as commodity multicore processors, graphics processors, reconfigurable processors, and others, are gaining attention as one approach to continuing performance improvement while managing the new challenge of energy efficiency. As these systems become more common, it is important to be able to compare and contrast architectural designs and programming systems in a fair and open forum. To this end, we have designed the Scalable HeterOgeneous Computing benchmark suite (SHOC). SHOC's initial focus is on systems containing graphics processing units (GPUs) and multi-core processors, and on the new OpenCL programming standard. SHOC is a spectrum of programs that test the performance and stability of these scalable heterogeneous computing systems. At the lowest level, SHOC uses microbenchmarks to assess architectural features of the system. At higher levels, SHOC uses application kernels to determine system-wide performance including many system features such as intranode and internode communication among devices. SHOC includes benchmark implementations in both OpenCL and CUDA in order to provide a comparison of these programming models.

99 GENERAL AND MISCELLANEOUS↗

Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

Field testing was performed in a new construction unoccupied test house in Pittsburgh, PA. Four air-based heating, ventilation, and air conditioning distribution systems—a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms—were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disentangling the gap between pure and mixed-gas performance of thin film composite membranes through improved cell design and testing methods

Testing thin film composite (TFC) membrane coupons at low stage-cuts (≤5%) in a sweep-gas permeation system is a common practice to obtain mixed-gas separation properties for benchmarking performance and making scale-up decisions. However, even under these idealized conditions, mixed-gas permeance and selectivity can be more than 30% lower than their pure-gas values, partially due to concentration polarization, an effect that typically intensifies with increased membrane permeance. This study investigates the effect of cell design on mixed-gas testing using PolyActive TM TFC membranes with pure-gas CO 2 permeance of 1700 – 3100 gas permeance unit (GPU), covering the permeance range of most state-of-the-art CO 2 /N 2 separation membranes. Here, we designed and 3D-printed a counter-current permeation cell with enhanced feed and sweep flow efficiency, resulting in a 33 – 41% increase in mixed-gas CO 2 permeance compared to traditional permeation cells. Furthermore, we compared sweep-gas and vacuum permeation methods using traditional permeation cells, revealing that the latter delivers 41% higher mixed-gas CO 2 permeance, because vacuuming effectively minimizes the downstream concentration polarization. These findings highlight the importance of cell design and permeation apparatus selection in lab-scale mixed-gas testing, with strong implications for module design and process optimization at the industrial scale.

mixed gas performance↗

Building America Case Study: Evaluating Through-Wall Air Transfer Fans, Pittsburgh, Pennsylvania (Fact Sheet)

In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. Four air-based HVAC distribution systems were assessed:-a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leveraging operational information from wastewater injection wells to evaluate CO 2 injection performance for carbon storage applications in the Appalachian Basin

Abstract Geologic parameters, geophysical logging, injection testing, and operational metrics from wastewater injection wells were integrated to develop a preliminary design of a carbon storage facility in the Appalachian Basin. A scattered group of 10–20 commercial wastewater injection wells dispose off produced water from oil and gas wells in the region, utilizing a sequence of stacked deep saline formations for injection zones. These wastewater injection wells provide practical benchmarks for understanding the feasibility of carbon dioxide (CO 2 ) storage. Geologic models were developed based on characterization data from the wastewater injection wells. Reservoir simulations were calibrated according to injection testing and operational data from the wastewater injection wells. Long‐term operational data on injection flow rates and pressures measured in the wastewater injection wells were especially useful to evaluate the performance of carbon storage applications. The simulations were used to estimate injection pressures, radius of CO 2 saturation, and pressure response for industrial scale CO 2 storage applications. Results were also used to provide a design basis in terms of number of injection wells, well spacing, area of review, injection system components, monitoring plan, and CO 2 pipeline distribution system. The analysis demonstrates that there is sufficient injectivity in the deep saline formations in the west‐central Appalachian Basin to store commercial volumes of anthropogenic CO 2 . The geologic system appears suitable for supporting CO 2 injection rates of 0.5–1.0 million metric tons per year at injection pressures below formation fracture pressure in a single well. The long‐term operational data of wastewater injection wells within the study area suggested a lower permeability‐thickness values than indicated by initial reservoir tests. A workflow for developing realistic permeability values for input into reservoir simulations is presented. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd.

Valluri, Manoj↗

CFD simulation of MSW combustion and SNCR in a commercial incinerator

Highlights: • Presented a CFD scheme for modeling MSW incinerator including SNCR process. • Performed a sensitivity analysis of SNCR operating conditions. • Non-uniform distributions of gas velocity, temperature and NO{sub x} in the incinerator. • The injection position of reagent was critical for a desirable performance of SNCR. • A NSR 1.5 was recommended as a compromise of NO{sub x} reduction rates and NH{sub 3} slip. - Abstract: A CFD scheme was presented for modeling municipal solid waste (MSW) combustion in a moving-grate incinerator, including the in-bed burning of solid wastes, the out-of-bed burnout of gaseous volatiles, and the selective non-catalytic reduction (SNCR) process between urea (CO(NH{sub 2}){sub 2}) and NO{sub x}. The in-bed calculations provided 2-D profiles of the gas–solid temperatures and the gas species concentrations along the bed length, which were then used as inlet conditions for the out-of-bed computations. The over-bed simulations provided the profiles of incident radiation heat flux on the top of bed. A 3-dimensional benchmark simulation was conducted with a 750 t/day commercial incinerator using the present coupling scheme incorporating with a reduced SNCR reduction mechanism. Numerical tests were performed to investigate the effects of operating parameters such as injection position, injection speed and the normalized stoichiometric ratio (NSR) on the SNCR performance. The simulation results showed that the distributions of gas velocity, temperature and NO{sub x} concentration were highly non-uniform, which made the injection position one of the most sensitive operating parameters influencing the SNCR performance of moving grate incinerators. The simulation results also showed that multi-layer injections were needed to meet the EU2000 standard, and a NSR 1.5 was suggested as a compromise of a satisfactory NO{sub x} reduction and reasonable NH{sub 3} slip rates. This work provided useful guides to the design and operation of SNCR process in moving-grate incinerators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an unacceptable level of bias.

benchmark problems↗

Adiabatic quantum support vector machines

Adiabatic quantum computers can solve difficult optimization problems (e.g., the quadratic unconstrained binary optimization problem), and they seem well suited to train machine learning models. In this paper, we describe an adiabatic quantum approach for training support vector machines. We show that the time complexity of our quantum approach is an order of magnitude better than the classical approach. Next, we compare the test accuracy of our quantum approach against a classical approach that uses the Scikit-learn library in Python across five benchmark datasets (Iris, Wisconsin Breast Cancer (WBC), Wine, Digits, and Lambeq). We show that our quantum approach obtains accuracies on par with the classical approach. Finally, we perform a scalability study in which we compute the total training times of the quantum approach and the classical approach with an increasing number of features and an increasing number of data points in the training dataset. In conclusion, our scalability results show that the quantum approach obtains a 3.5–4.5x speedup over the classical approach on datasets with many (millions of) features.

Computational Complexity↗

Dynamic signatures of electronically nonadiabatic coupling in sodium hydride: a rigorous test for the symmetric quasi-classical model applied to realistic, ab initio electronic states in the adiabatic representation

Sodium hydride (NaH) in the gas phase presents a seemingly simple electronic structure making it a potentially tractable system for the detailed investigation of nonadiabatic molecular dynamics from both computational and experimental standpoints. The single vibrational degree of freedom, as well as the strong nonadiabatic coupling that arises from the excited electronic states taking on considerable ionic character, provides a realistic chemical system to test the accuracy of quasi-classical methods to model population dynamics where the results are directly comparable against quantum mechanical benchmarks. Here, using a simulated pump–probe type experiment, this work presents computational predictions of population transfer through the avoided crossings of NaH via symmetric quasi-classical Meyer–Miller (SQC/MM), Ehrenfest, and exact quantum dynamics on realistic, ab initio potential energy surfaces. The main driving force for population transfer arises from the ground vibrational level of the D 1 Σ + adiabatic state that is embedded in the manifold of near-dissociation C 1 Σ + vibrational states. When coupled through a sharply localized first-order derivative coupling most of the population transfers between t = 15 and t = 30 fs depending on the initially excited vibronic wavepacket. While quantum mechanical effects are expected due to the reduced mass of NaH, predictions of the population dynamics from both the SQC/MM and Ehrenfest models perform remarkably well against the quantum dynamics benchmark. Additionally, an analysis of the vibronic structure in the nonadiabatically coupled regime is presented using a variational eigensolver methodology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electromagnetic physics vectorization in the GeantV transport framework

The development of the GeantV Electromagnetic (EM) physics package has evolved following two necessary paths towards code modernization. A first phase required the revision of the main electromagnetic physics models and their implementation. The main objectives were to improve their accuracy, extend them to the new high-energy frontier posed by the Future Circular Collider (FCC) programme and allow a better adaptation to a multi-particle flow. Most of the EM physics models in GeantV have been reviewed from theoretical perspective and rewritten with vector-friendly implementations, being now available in scalar mode in the alpha release. The second phase consists of a thorough investigation on the possibility to vectorise the most CPU-intensive physics code parts, such as final state sampling. We have shown the feasibility of implementing electromagnetic physics models that take advantage of SIMD/SIMT architectures, thus obtaining gains in performance. After this phase, the time has come for the GeantV project to take a step forward towards the final proof of concept. This takes shape through the testing of the full simulation chain (transport + physics + geometry) running in vectorized mode. In this paper we will present the first benchmark results obtained after vectorizing a full set of electromagnetic physics models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mixed quantum/classical calculations of total and differential elastic and rotationally inelastic scattering cross sections for light and heavy reduced masses in a broad range of collision energies

The mixed quantum/classical theory (MQCT) for rotationally inelastic scattering developed recently [A. Semenov and D. Babikov, J. Chem. Phys. 139, 174108 (2013)] is benchmarked against the full quantum calculations for two molecular systems: He + H{sub 2} and Na + N{sub 2}. This allows testing new method in the cases of light and reasonably heavy reduced masses, for small and large rotational quanta, in a broad range of collision energies and rotational excitations. The resultant collision cross sections vary through ten-orders of magnitude range of values. Both inelastic and elastic channels are considered, as well as differential (over scattering angle) cross sections. In many cases results of the mixed quantum/classical method are hard to distinguish from the full quantum results. In less favorable cases (light masses, larger quanta, and small collision energies) some deviations are observed but, even in the worst cases, they are within 25% or so. The method is computationally cheap and particularly accurate at higher energies, heavier masses, and larger densities of states. At these conditions MQCT represents a useful alternative to the standard full-quantum scattering theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of a Hybrid Domain Overlapping Coupling Between SAM and CFD Against the TALL-3D Transients

The System Thermal Hydraulics (STH) code SAM has been coupled to the Computational Fluid Dynamics (CFD) code Simcenter STAR-CCM+ utilizing a hybrid domain overlapping method with an explicit coupling in time. The coupling aims to extend the STH code’s applicability to scenarios where local momentum and energy transfers are important yet difficult for STH codes to capture, such as three-dimensional (3D) mixing. The coupling method’s numerical stability was verified in the past against two closed-loop configurations, and it was validated against a double T-junction experiment with 3D scalar mixing. In the present work, the coupling method is validated against the TALL-3D STH/CFD coupling benchmark facility. TALL-3D is a three-legged, liquid-metal facility with a large, pool-type enclosure (test section) that exhibits 3D flow effects to be modeled by a CFD code. The rest of the system exhibits approximately 1D behavior well-predicted by an STH code. First, the present STAR-CCM+ CFD model of the 3D test section is validated against experimental data. Then, the SAM-STARCCM+ coupled model is validated against six different TALL-3D steady states, including SAM standalone model results for comparison. Lastly, the SAM-STARCCM+ coupled model is validated against two TALL-3D transients, one exhibiting flow reversal in the test section and one exhibiting nonlinear, Limit Cycle Oscillations (LCO). For the first transient, the SAM-STARCCM+ coupled model properly predicts an increase in the test section’s inlet temperature during flow reversal, and this is not predicted by the SAM standalone model. Following flow reversal, the SAM-STARCCM+ coupled model better-predicts the initial flow recovery and following oscillations as the system approaches a final natural circulation state. For the second transient, no true final steady state is observed due to LCO. Neither the SAM-STARCCM+ coupled model nor the SAM standalone model can perfectly capture the experiment’s changing oscillation frequency during the transient. However, the SAM-STARCCM+ coupled model does reproduce the oscillatory feedback observed in the system. This is a significant achievement as the SAM-STARCCM+ coupled model only uses an explicit coupling in time, as opposed to a semi-implicit coupling. In comparison, previous STH/CFD coupling efforts of the TALL-3D facility required semi-implicit coupling to obtain similar results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗