Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baseline estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Long-Term Results of Radiation Therapy Oncology Group 9903: A Randomized Phase 3 Trial to Assess the Effect of Erythropoietin on Local-Regional Control in Anemic Patients Treated With Radiation Therapy for Squamous Cell Carcinoma of the Head and Neck

Purpose: This paper reports long-term results of RTOG 9903, to determine whether the addition of erythropoietin (EPO) would improve the outcomes of radiation therapy (RT) in mildly to moderately anemic patients with head and neck squamous cell carcinoma (HNSCCa). Methods and Materials: The trial included HNSCCa patients treated with definitive RT. Patients with stage III or IV disease received concomitant chemoradiation therapy or accelerated fractionation. Pretreatment hemoglobin levels were required to be between 9.0 and 13.5 g/dL (12.5 g/dL for females). EPO, 40,000 U, was administered weekly starting 7 to 10 days before RT was initiated in the RT + EPO arm. Results: A total of 141 of 148 enrolled patients were evaluable. The baseline median hemoglobin level was 12.1 g/dL. In the RT + EPO arm, the mean hemoglobin level at 4 weeks increased by 1.66 g/dL, whereas it decreased by 0.24 g/dL in the RT arm. With a median follow-up of 7.95 years (range: 1.66-10.08 years) for surviving patients and 3.33 years for all patients (range: 0.03-10.08 years), the 5-year estimate of local-regional failure was 46.2% versus 39.4% (P=.42), local-regional progression-free survival was 31.5% versus 37.6% (P=.20), and overall survival was 36.9% versus 38.2% (P=.54) for the RT + EPO and RT arms, respectively. Late toxicity was not different between the 2 arms. Conclusions: This long-term analysis confirmed that despite the ability of EPO to raise hemoglobin levels in anemic patients with HNSCCa, it did not improve outcomes when added to RT. The possibility of a detrimental effect of EPO could not be ruled out.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Requirements and sensitivity analysis for temporally- and spatially-resolved thermometry using neutron resonance spectroscopy

Neutron resonance spectroscopy (NRS) has been used extensively to make temperature measurements that are accurate, absolute, and nonperturbative within the interior of material samples under extreme conditions applied quasistatically. Yet NRS has seldom been used in dynamic experiments. There is a compelling incentive to do so because of the significant shortcomings of alternative techniques. An important barrier to adopting dynamic NRS thermometry is the difficulty in fielding it with conventional spallation neutron sources. To enable time-dependent and spatially resolved temperature measurements in dynamic environments, more compact neutron sources that can be used at user facilities in conjunction with other diagnostic probes (such as x-ray light sources) are required. Such sources may be available using ultrafast high-intensity optical lasers. We evaluate such possibilities by determining the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters. Based on that evaluation, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful dynamic temperature measurement. Dynamic thermometry measurements are examined in this context when driven by two alternative fast-neutron sources: the Los Alamos Neutron Scattering Center (LANSCE) proton accelerator driving isotropic spallation neutrons as a baseline and a laser-plasma ion accelerator driving a neutron beam from deuterium breakup. Strategies to close the gap between the required and demonstrated performance of laser-based fast-neutron sources are presented. A short-pulse high-intensity laser with state-of-the-art pulse contrast and an energy of a few hundred Joules would drive a compact neutron source suitable for NRS thermometry that could transform the dynamic study of materials.

47 OTHER INSTRUMENTATION↗

Detection of a high brightness temperature radio core in the active-galactic-nucleus-driven molecular outflow candidate NGC 1266

We present new high spatial resolution Karl G. Jansky Very Large Array (VLA) H I absorption and Very Long Baseline Array (VLBA) continuum observations of the active-galactic-nucleus-(AGN-)driven molecular outflow candidate NGC 1266. Although other well-known systems with molecular outflows may be driven by star formation (SF) in a central molecular disk, the molecular mass outflow rate of 13 M {sub ☉} yr{sup –1} in NGC 1266 reported by Alatalo et al. exceeds SF rate estimates from a variety of tracers. This suggests that an additional energy source, such as an AGN, may play a significant role in powering the outflow. Our high spatial resolution H I absorption data reveal compact absorption against the radio continuum core co-located with the putative AGN, and the presence of a blueshifted spectral component re-affirms that gas is indeed flowing out of the system. Our VLBA observations at 1.65 GHz reveal one continuum source within the densest portion of the molecular gas, with a diameter d < 8 mas (1.2 pc), a radio power P {sub rad} = 1.48 × 10{sup 20} W Hz{sup –1}, and a brightness temperature T {sub b} > 1.5 × 10{sup 7} K that is most consistent with an AGN origin. The radio continuum energetics implied by the compact VLBA source, as well as archival VLA continuum observations at lower spatial resolution, further support the possibility that the AGN in NGC 1266 could be driving the molecular outflow. These findings suggest that even low-level AGNs may be able to launch massive outflows in their host galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Beam-dump ceiling and its experimental implications: The case of a portable experiment

We generalize the nature of the so-called beam-dump “ceiling” beyond which the improvement on the sensitivity reach in the search for fast-decaying mediators dramatically slows down, and we point out its experimental implications that motivate tabletop-sized beam-dump experiments for the search. Light (bosonic) mediators are well-motivated new-physics particles, as they can appear in dark-sector portal scenarios and models to explain various laboratory-based anomalies. Due to their low mass and feebly interacting nature, beam-dump-type experiments, utilizing high-intensity particle beams, can play a crucial role in probing the parameter space of such visibly decaying mediators—in particular, the “prompt decay” region, where the mediators feature relatively large coupling and mass. We present a general and semianalytic proof that the ceiling effectively arises in the prompt-decay region of an experiment and show its insensitivity to data statistics, background estimates, and systematic uncertainties, considering a concrete example, the search for axion-like particles interacting with ordinary photons at three benchmark beam facilities: PIP-II at FNAL, and SPS and LHC-dump at CERN. We then identify optimal criteria to perform a cost-effective and short-term experiment to reach the ceiling, demonstrating that very short-baseline compact experiments enable access to the parameter space unreachable thus far.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-I-63: Relaxation Times of Lipid Resonances in NAFLD Animal Model Using Enhanced Curve Fitting

Purpose: The objective of this study is to evaluate the relaxation time of methylene resonance in comparison with other lipid resonances. Methods: The examinations were performed on a 3.0T MRI scanner using a four-channel animal coil. Eight more Sprague-Dawley rats in the same baseline weight range were housed with ad libitum access to water and a high-fat (HF) diet (60% fat, 20% protein, and 20% carbohydrate). In order to avoid large blood vessels, a voxel (0.8×0.8×0.8 cm{sup 3}) was placed in a homogeneous area of the liver parenchyma during free breathing. Lipid relaxations in NC and HF diet rats were estimated at a fixed repetition time (TR) of 6000 msec, and multi echo time (TEs) of 40–220 msec. All spectra for data measurement were processed using the Advanced Method for Accurate, Robust, and Efficient Spectral (AMARES) fitting algorithm of the Java-based Magnetic Resonance User Interface (jMRUI) package. Results: The mean T2 relaxation time of the methylene resonance in normal-chow diet was 37.1 msec (M{sub 0}, 2.9±0.5), with a standard deviation of 4.3 msec. The mean T2 relaxation time of the methylene resonance was 31.4 msec (M{sub 0}, 3.7±0.3), with a standard deviation of 1.8 msec. The T2 relaxation times of methylene protons were higher in normal-chow diet rats than in HF rats (p<0.05), and the extrapolated M{sub 0} values were higher in HF rats than in NC rats (p<0.005). The excellent linear fit with R{sup 2}>0.9971 and R{sup 2}>0.9987 indicates T2 relaxation decay curves with mono-exponential function. Conclusion: In in vivo, a sufficient spectral resolution and a sufficiently high signal-to-noise ratio (SNR) can be achieved, so that the data measured over short TE values can be extrapolated back to TE = 0 to produce better estimates of the relative weights of the spectral components. In the short term, treating the effective decay rate as exponential is an adequate approximation.

60 APPLIED LIFE SCIENCES↗

Parabolic Trough Collector Cost Update for the System Advisor Model (SAM)

This report updates the baseline cost for parabolic trough solar fields in the United States within NREL's System Advisor Model (SAM). SAM, available at no cost at https://sam.nrel.gov/, is a performance and financial model designed to facilitate decision making for people involved in the renewable energy industry. SAM is the primary tool used by NREL and the U.S. Department of Energy (DOE) for estimating the performance and cost of concentrating solar power (CSP) technologies and projects. The study performed a bottom-up build and cost estimate for two state-of-the-art parabolic trough designs -- the SkyTrough and the Ultimate Trough. The SkyTrough analysis estimated the potential installed cost for a solar field of 1500 SCAs as $170/m 2 +/- $6/m 2 . The investigation found that SkyTrough installed costs were sensitive to factors such as raw aluminum alloy cost and production volume. For example, in the case of the SkyTrough, the installed cost would rise to nearly $210/m 2 if the aluminum alloy cost was $1.70/lb instead of $1.03/lb. Accordingly, one must be aware of fluctuations in the relevant commodities markets to track system cost over time. The estimated installed cost for the Ultimate Trough was only slightly higher at $178/m 2 , which includes an assembly facility of $11.6 million amortized over the required production volume. Considering the size and overall cost of a 700 SCA Ultimate Trough solar field, two parallel production lines in a fully covered assembly facility, each with the specific torque box, module and mirror jigs, would be justified for a full CSP plant.

47 OTHER INSTRUMENTATION↗

Tests of LBNF Beam Monitor Prototypes for the DUNE Experiment

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline on-axis neutrino oscillation experiment that will use a beam from the Long-Baseline Neutrino Facility (LBNF) to constrain the mixing angle $$\theta_{23}$, the neutrino mass hierarchy, and the CP violating phase $\delta_{CP}$. To ensure the beam remains on-axis, the LBNF beamline will employ two ionization chamber systems: the Hadron Alignment Detection System (HADeS) for primary beam alignment and the Muon Monitoring System (MuMS) for continuous beam monitoring and neutrino flux estimation. We have constructed prototypes for these systems at the University of Texas at Austin based on a design currently used in the NuMI hadron monitor. These prototypes were tested with a radioactive source and in beam tests at Fermilab's Irradiation Test Area. We present the results of these studies and discuss ongoing efforts to optimize the HADeS and MuMS designs.

Murthy, Chinmay↗

Pilot-Scale Demonstration of ALTA for NOx Control in Pulverized Coal-Fired Boilers

This report describes computational fluid dynamics (CFD) modeling and pilot-scale testing conducted to demonstrate the ability of the Advanced Layered Technology Approach (ALTA) to reduce NO{sub x} emissions in a pulverized coal (PC) boiler. Testing specifically focused on characterizing NO{sub x} behavior with deep burner staging combined with Rich Reagent Injection (RRI). Tests were performed in a 4 MBtu/hr pilot-scale furnace at the University of Utah. Reaction Engineering International (REI) led the project team which included the University of Utah and Combustion Components Associates (CCA). Deep burner staging and RRI, combined with selective non-catalytic reduction (SNCR), make up the Advanced Layered Technology Approach (ALTA) for NO{sub x} reduction. The application of ALTA in a PC environment requires homogenization and rapid reaction of post-burner combustion gases and has not been successfully demonstrated in the past. Operation of the existing low-NO{sub x} burner and design and operation of an application specific ALTA burner was guided by CFD modeling conducted by REI. Parametric pilot-scale testing proved the chemistry of RRI in a PC environment with a NOx reduction of 79% at long residence times and high baseline NOx rate. At representative particle residence times, typical operation of the dual-register low-NO{sub x} burner provided an environment that was unsuitable for NO{sub x} reduction by RRI, showing no NOx reduction. With RRI, the ALTA burner was able to produce NO{sub x} emissions 20% lower than the low-NO{sub x} burner, 76 ppmv vs. 94 ppmv, at a burner stoichiometric ratio (BSR) of 0.7 and a normalized stoichiometric ratio (NSR) of 2.0. CFD modeling was used to investigate the application of RRI for NO{sub x} control on a 180 MW{sub e} wall-fired, PC boiler. A NO{sub x} reduction of 37% from baseline (normal operation) was predicted using ALTA burners with RRI to produce a NO{sub x} emission rate of 0.185 lb/MBtu at the horizontal nose of the boiler. When combined with SNCR, a NO{sub x} emission rate of 0.12-0.14 lb/MBtu can be expected when implementing a full ALTA system on this unit. Cost effectiveness of the full ALTA system was estimated at $2,152/ton NO{sub x} removed; this was less than 75% of the cost estimated for an SCR system on a unit of this size.

01 COAL, LIGNITE, AND PEAT↗

Performance of differenced range data types in Voyager navigation

Voyager radio navigation made use of a differenced rage data type for both Saturn encounters because of the low declination singularity of Doppler data. Nearly simultaneous two-way range from two-station baselines was explicitly differenced to produce this data type. Concurrently, a differential VLBI data type (DDOR), utilizing doubly differenced quasar-spacecraft delays, with potentially higher precision was demonstrated. Performance of these data types is investigated on the Jupiter-to-Saturn leg of Voyager 2. The statistics of performance are presented in terms of actual data noise comparisons and sample orbit estimates. Use of DDOR as a primary data type for navigation to Uranus is discussed.

Taylor, T. H.↗

Demand Response Opportunities in Industrial Refrigerated Warehouses in California

Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost: Preprint

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This in turn is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in EGS binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost.

ambient temperature↗

HIGH-LEVEL WASTE FEED CERTIFICATION IN HANFORD DOUBLE-SHELL TANKS

The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste Treatment and Immobilization Plant (WTP) presents a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. DOE's River Protection Project (RPP) mission modeling and WTP facility modeling assume that individual 3785 cubic meter (l million gallon) HLW feed tanks are homogenously mixed, representatively sampled, and consistently delivered to the WTP. It has been demonstrated that homogenous mixing ofHLW sludge in Hanford DSTs is not likely achievable with the baseline design thereby causing representative sampling and consistent feed delivery to be more difficult. Inconsistent feed to the WTP could cause additional batch-to-batch operational adjustments that reduce operating efficiency and have the potential to increase the overall mission length. The Hanford mixing and sampling demonstration program will identify DST mixing performance capability, will evaluate representative sampling techniques, and will estimate feed batch consistency. An evaluation of demonstration program results will identify potential mission improvement considerations that will help ensure successful mission completion. This paper will discuss the history, progress, and future activities that will define and mitigate the mission risk.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

22” ADP Fan Rig Liners Design Report

A liner design study was conducted as part of a cooperative effort between five (5) government/industry teams that together seek to demonstrate the technology for designing and manufacturing acoustic liners that are twenty five percent (25%) more efficient than 1992 technology liners. The study emphasized teaming collaboration. The improved liners were designed by Pratt & Whitney and Boeing Airplane Company and built by Rohr Inc, and will be tested in the NASA/P& W 22-inch ADP fan rig at NASA Lewis Research Center's 9' x 15' wind tunnel. Design guidelines and decisions were made collectively during monthly design review telecons and at the formal final design review. The tools that were used to design the new improved liners were not new, but the process that was developed as part of this study that led into the evaluation and selection of the final and best liner designs is new. Until now, the liner design process as practiced by different industry teams varied greatly. Some procedures were based on empirical liner attenuation databases which could not adequately account for engine-to-engine hardwall fan noise spectral differences, while others were entirely theoretical. And regardless of which method one chose, the major difficulty was still the lack of understanding and knowledge of the actual hardwall fan source noise modal structure and farfield SPL spectra. The NASA-led effort to attempt actual measurements of the fan source noise modal structure by means of the rotating microphone array is expected to contribute significantly to the understanding of the nature of the fan tone noise modes, but the application to broadband noise is still a long way off. The new design process included consideration of the measured fan tone modes, but for the majority of the spectra a separate, systematic process was used. It is a common practice in the engine/nacelle industry that acoustic liners for new products are designed before actual measured hardwall engine far-field noise spectra are available. Target noise spectra are normally derived from existing engine noise databases with some adjustments to absolute SPLs and frequencies. This practice has been acceptable as long as the new engine was a derivative of the base engine. However, in the case of the ADP, the transition from a current engine base is too - great, and the adjustments could not adequately account for the quantum changes in SPL spectral differences. Examples were the 1992 single degree of freedom (SDOF) inlet and aft liners (designed by P&W) that would be used as the baseline liners against which the new improved liners' efficien¬cies would -be measured. As will be shown, these baseline liners have been found to be deeper than the desire optimum depths. The new liner design process begins with the selection of the target hard wall fan noise spectra. These spectra were obtained by scaling up (5.91 scale factor) the measured hardwall fan spectral data from the 22” ADP fan rig. Next, the modal energy contents for each 1/3-octave band center frequency of these hardwall fan noise spectra are estimated. (Within each 1/3-octave band center frequency, the model energy distribution approximation is for both tone and broadband noise). For the inlet noise, P&W uses a derivative of the NASA Lewis (Ed Rice's) method of classifying; and grouping propagating modes by their cutoff ratios. The next step is to assign energy level to each group of modes having the same cutoff ratio. In Ed Rice's model, the modes were grouped according to ten (10) cutoff ratio intervals with center values located at 1.026, 1.085, 1.155, 1.24, 1.35, 1.49, 1.69, 2.0, and 4.47 (with equal number of modes in each interval). The modes were assumed to have equal energy. P&W’s model expands the cutoff ratio-mode grouping into two hundred (200) smaller cutoff ratio intervals with center values located f1".'m 1.003 to 11.5 in 199 increasing incremental intervals. Next, P&W's model uses a "2-parameter" normal distribution as a template to assign energy levels to these 200 pre-determined cutoff ratio values (for each 1/3-octave band center frequency). In the past, P&W had conducted an extensive study to determine what "2-parameter" values are appropriate for fullscale inlet liners, and had developed a set of twenty-four (24) "2-pararneter" values (i.e. one for each 1/3-octave frequency band) that when used in Ed Rice's Inlet Attenuation Prediction Method produced predicted liner attenuations that closely matched measured liner attenuations from several P&W's engines. In the absence of actual measured tone and broadband modal data from the 22" ADP rig, the process will use P&W's proprietary set of "2-parameter" values for this liner design study. For the aft noise, Boeing uses a modal energy approximation that the "transport energy" of each propagating mode is equal. This approximation is almost the same as the equal energy per mode approximation, except for modes that are near cutoff. Boeing's model forces these modes to have lower energy levels. Both P&W and Boeing agreed that the "transport energy" approximation should work well for the ADP aft fan noise which appears to be dominated by broadband noise. The design process then proceeds to calculate the optimum liner impedances for each frequency in both the inlet and the aft. These optimum impedances represent the target impedances that the designed liners should have. Liners with impedances matching the optimum impedances at all frequencies are "ideal" liners. These ideal liners are theoretically the best liners. Unfortunately, it has been showed that it is impossible to design and build such ideal liners. The next best liners are ones that have impedances matching the optimum impedances over some frequency range (not all frequencies as for the ideal). This is accomplished by the use of "frequency weightings". Several of P&W's and Boeing's existing computer decks were used for optimizing and matching the designed liner impedances to the target optimum values (with the various frequency weightings specified). The optimization produces liner candidates with predicted liner impedances and descriptions of their physical liner characteristics. These candidate liner impedances are then used to predict their spectral attenuation characteristics which are then used together with the target hardwall fan noise spectra to determine the resulting treated noise spectra and PNLT values. Further optimization around the selected candidate designs yield final designs that are best in PNLT attenuations. Use of the optimization decks allowed a large number of liner candidates to be screened in a relatively short period of time. This design process is systematic and is efficient. The new inlet SDOF liner design obtained from the improved process was predicted to be 34% more effective (per unit area) than the 1992 baseline inlet liner. This inlet liner design is a 112 rayl wovenwiremesh facesheet over a 0.312-inch deep honeycomb core. The new aft SDOF liner design was predicted to be 52% more efficient than the aft baseline liner. The new aft SDOF liner is "segmented" with a shallower liner on the core cowl (inner duct wall) and a deeper liner on the fan cowl (outer duct wall). The shallower liner is a 70.6 rayl woven-wiremesh facesheet over a 0.141-inch deep honeycomb core. The deeper liner is a 68 rayl woven-wiremesh facesheet over a 0.309-inch deep honeycomb core. All liner dimensions are for the 22-inch model-scale ADP fan rig liners. The selected advanced liners are "segmented" double-layer (DDOF) liners for the inlet and aft locations. Also, for the inlet, a bulk liner with ceramic foam for wider broadband noise absorption was also selected. Triple-layer liner designs were not considered since the model scaled liners ( 1/5. 91) were dimensionally too small to be built correctly, and irrin earlier concept study, Boeing found a triple-layer to have only very small benefits over a double-layer. The inlet DDOF liner was predicted to be 83% more effective than the baseline. The inlet DDOF design is a 78 rayl facesheet over a 0.080 top cavity depth, a 68 rayl septum and a 0.227-inch bottom cavity depth. The inlet bulk liner is a 60 rayl facesheet over a 0.33-inch deep honeycomb filled with high temperature (HTP) ceramic foam with a density of 4.8 lb/cu.ft and a flow resistivity of 167 rayl/cm. The inlet bulk liner was predicted to be 83% more effective than the baseline liner. The aft DDOF liners are segmented with a shallower liner on the core cowl and a deeper liner on the fan cowl. The shallow DDOF liner is a 49.8 rayl facesheet over a 0.093-inch top cavity depth, a septum of 88.2 rayls over a 0.181-inch bottom cavity depth. The deep DDOF liner is a 12.9 rayl facesheet over a 0.140-inch top cavity depth, a septum of 53.1 ray ls over a 0.258-inch botom cavity depth. The segmented aft DDOF liners were predicted to be 86% more efficient than the baseline liner.

turbofan acoustic treatment↗

Climate-extreme modeling framework for sustainable flood management in the Arabian Peninsula

Evaluating extreme precipitation events (EPEs) is essential for building climate-resilient water management strategies, but it remains a major challenge in ungauged basins. Using the 26,070 km 2 Wadi al-Rummah basin in central Saudi Arabia as a case study, we developed an alternative, reliable, cost-effective satellite-based framework that combines empirically derived EPE thresholds, imagery-calibrated 2D hydrodynamic modeling, GRACE water-storage diagnostics, and bias-corrected CMIP6 projections to assess flood hazards and recharge potential under current and future climate scenarios in ungauged basins. The integrated approach and the resulting findings followed four key steps: (1) Identified a 22.5 mm EPE threshold, the 80th percentile of 3-day GPM/IMERG rainfall (2000–2024), aligned with flood-triggering events (Nov 2018: 23–28 mm; Apr, 2023: 42 mm); (2) Developed and calibrated a RiverFlow2D model using Sentinel-2 and PlanetScope imagery for the November 2018 flood, accurately reproducing flood depth and extent (RMSE ≤0.31 m; fuzzy-Dice ≥0.91), and estimating runoff (41 %), infiltration (25 %), and evaporation (34 %); (3) Independently validated the model with the April 2023 event (RMSE ≤0.35 m; fuzzy-Dice ≥0.86); (4) Conducted climate projections (2025–2100) from five bias-corrected NEX-GDDP CMIP6 models that revealed a 34 % increase in EPE intensity under SSP2-4.5 and 48 % under SSP5-8.5 scenarios, relative to 20th-century baselines. Our findings indicate that while intensifying extremes in the 21st century increase flood risk, the results highlight the potential for episodic recharge if effective retention strategies are employed, and offer a transferable model for climate-informed planning in data-scarce arid regions.

CMIP6↗

sin 2 θ W estimate and neutrino electromagnetic properties from low-energy solar data

We report new values of weak-mixing angle ($\sin ^{2}\theta _{W}$)$,$ neutrino effective magnetic moment and the charge radius using the lowest-energy (to-date) solar neutrino data of pp, $^{7}$Be and pep spectra from phase-I and phase-II runs of Borexino experiment. The best-fit values are $\sin ^{2}\theta _{W}=$0.235$\pm $0.019 with a precision comparable to that of the combined reactor and accelerator very short-baseline experiments and $\mu _{\nu }^{eff}\leq 8.7\times 10^{-12}\mu _{B}$ at 90% C.L. with a factor of 3 improvement than the previous bounds. This leads to the improvement of all the related magnetic moment matrix elements for the Majorana-type and Dirac-type in mass basis and also improvement on bounds on the flavor magnetic moment states. The bounds on the neutrino charged radii turn out to be $-0.82\times 10^{-32}$cm$^{2}\leq \left \langle r_{\nu _{e}}^{2}\right \rangle \ \leq 1.27\times 10^{-32}$ cm$^{2}\ $and $-9\times 10^{-32}$cm$^{2}\leq \left \langle r_{\nu _{\mu },\nu _{\tau }}^{2}\right \rangle \ \leq 3.1\times 10^{-31}$ cm$^{2}\ $ at 90% C.L..

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higher Accuracy Template for Corner Cube Reflected Image

Video images of laser beams are analyzed to determine the position of the laser beams for alignment purpose in the National Ignition Facility (NIF). Algorithms process beam images to facilitate automated laser alignment. One such beam image, known as the corner cube reflected pinhole image, exhibits wide beam quality variations that are processed by a matched-filter-based algorithm. The challenge is to design a representative template that captures these variations while at the same time assuring accurate position determination. This paper describes the development of a new analytical template to accurately estimate the center of a beam with good image quality. The templates are constructed to exploit several key recurring features observed in the beam images. When the beam image quality is low, the algorithm chooses a template that contains fewer features. The algorithm was implemented using a Xilinx Virtex II Pro FPGA implementation that provides a speedup of about 6.4 times over a baseline 3GHz Pentium 4 processor.

42 ENGINEERING↗

Suitability of markerless EPID tracking for tumor position verification in gated radiotherapy

Purpose: To maximize the benefits of respiratory gated radiotherapy (RGRT) of lung tumors real-time verification of the tumor position is required. This work investigates the feasibility of markerless tracking of lung tumors during beam-on time in electronic portal imaging device (EPID) images of the MV therapeutic beam. Methods: EPID movies were acquired at ∼2 fps for seven lung cancer patients with tumor peak-to-peak motion ranges between 7.8 and 17.9 mm (mean: 13.7 mm) undergoing stereotactic body radiotherapy. The external breathing motion of the abdomen was synchronously measured. Both datasets were retrospectively analyzed inPortalTrack, an in-house developed tracking software. The authors define a three-step procedure to run the simulations: (1) gating window definition, (2) gated-beam delivery simulation, and (3) tumor tracking. First, an amplitude threshold level was set on the external signal, defining the onset of beam-on/-off signals. This information was then mapped onto a sequence of EPID images to generate stamps of beam-on/-hold periods throughout the EPID movies in PortalTrack, by obscuring the frames corresponding to beam-off times. Last, tumor motion in the superior-inferior direction was determined on portal images by the tracking algorithm during beam-on time. The residual motion inside the gating window as well as target coverage (TC) and the marginal target displacement (MTD) were used as measures to quantify tumor position variability. Results: Tumor position monitoring and estimation from beam's-eye-view images during RGRT was possible in 67% of the analyzed beams. For a reference gating window of 5 mm, deviations ranging from 2% to 86% (35% on average) were recorded between the reference and measured residual motion. TC (range: 62%–93%; mean: 77%) losses were correlated with false positives incidence rates resulting mostly from intra-/inter-beam baseline drifts, as well as sudden cycle-to-cycle fluctuations in exhale positions. Both phenomena can lead to considerable deviations (with MTD values up to a maximum of 7.8 mm) from the intended tumor position, and in turn may result in a marginal miss. The difference between tumor traces determined within the gating window against ground truth trajectory maps was 1.1 ± 0.7 mm on average (range: 0.4–2.3 mm). Conclusions: In this retrospective analysis of motion data, it is demonstrated that the system is capable of determining tumor positions in the plane perpendicular to the beam direction without the aid of fiducial markers, and may hence be suitable as an online verification tool in RGRT. It may be possible to use the tracking information to enable on-the-fly corrections to intra-/inter-beam variations by adapting the gating window by means of a robotic couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗