Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

WE-FG-202-11: Longitudinal Diffusion MRI for Treatment Assessment of Sarcoma Patients with Pre-Operative Radiation Therapy

Purpose: Diffusion weighted MRI (DWI) is a promising imaging technique for early prediction of tumor response to radiation therapy. A recently proposed longitudinal DWI strategy using a Co-60 MRI guided RT system (MRIgRT) may bring functional MRI guided adaptive radiation therapy closer to clinical utility. We report our preliminary results of using this longitudinal DWI approach performed on the MRIgRT system for predicting the response of sarcoma patient to preop RT. Methods: Three sarcoma patients who underwent fractionated IMRT were recruited in this study. For all three patients DWI images were acquired immediately following his/her treatment. For each imaging session, ten slices were acquired interleaved with the b values covering the gross tumor volume (GTV). The diffusion images were processed to obtain the ADC maps using standard exponential fitting for each voxel. Regions of interest were drawn in the tumor on the diffusion images based on each patient’s clinical GTV contours. Each patient subsequently underwent surgery and the tumor necrosis score was available from standard pathology. The ADC values for each patient were compared to the necrosis scores to assess the predictive value of our longitudinal DWI for tumor response. Results: Each patient underwent 3 to 5 diffusion MRI scans depending on their treatment length. Patient 1 had a relatively unchanged ADC during the course of RT and a necrosis score of 30% at surgery. For patient 2, the mean ADC values decreased from 1.56 × 10-3 to 1.12 × 10-3 mm2/s and the patient’s necrosis score was less than 10%. Patient 3 had a slight increase in the ADC values from 0.59 × 10-3 to 0.71 × 10-3 mm2/s and patient’s necrosis score was 50%. Conclusion: Based on limited data from 3 patients, our longitudinal changes in tumor ADC assessed using the MRIgRT system correlated well with pathology results.

60 APPLIED LIFE SCIENCES↗

ENHANCING CORONAL STRUCTURES WITH THE FOURIER NORMALIZING-RADIAL-GRADED FILTER

Images of the corona have a high dynamic range which is excellent for quantitative photometric analysis. To understand the processes governing the solar corona, it is essential to have information about the absolute brightness as well as the underlying structure. However, due to the steep radial gradient of brightness in the images, and to the fact that structures closer to the solar disk have higher contrast than structures further from the disk, human vision cannot view the intricate structure of the corona in such images. The recently developed normalizing-radial-graded filter (NRGF) is an effective way for revealing the coronal structure. In this work, we present a more adaptive filter inspired by the NRGF, which we call the Fourier normalizing-radial-graded filter (FNRGF). It approximates the local average and the local standard deviation by a finite Fourier series. This method enables the enhancement of finer details, especially in regions of lower contrast. We also show how the influence of additive noise is reduced by a modification to the FNRGF. To illustrate the power of the method, the FNRGF is applied to images of emission from coronal forbidden lines observed during the 2010 July 11 total solar eclipse. It is also successfully applied to space-based observations of the low corona in the extreme ultraviolet and to white light coronagraph observations, thus demonstrating the validity of the FNRGF as a new tool that will help the interpretation of the information embedded in most types of coronal images.

79 ASTRONOMY AND ASTROPHYSICS↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 deg. arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered at the central slice were compared. For classification of masses using the PV approach, a feature extraction process similar to that described above for the DBT approach was performed on the ROIs from the individual PVs. Six feature spaces obtained from the central PV alone and by averaging the corresponding features from three to 11 PVs were formed. In each feature space for either the DBT-slice or the PV approach, a linear discriminant analysis classifier with stepwise feature selection was trained and tested using a two-loop leave-one-case-out resampling procedure. Simplex optimization was used to guide feature selection automatically within the training set in each leave-one-case-out cycle. The performance of the classifiers was evaluated by the area (A{sub z}) under the receiver operating characteristic curve. Results: The test A{sub z} values from the DBT-slice approach ranged from 0.87{+-}0.03 to 0.93{+-}0.02, while those from the PV approach ranged from 0.78{+-}0.04 to 0.84{+-}0.04. The highest test A{sub z} of 0.93{+-}0.02 from the nine-DBT-slice feature space was significantly (p=0.006) better than the highest test A{sub z} of 0.84{+-}0.04 from the nine-PV feature space. Conclusion: The features of breast lesions extracted from the DBT slices consistently provided higher classification accuracy than those extracted from the PV images.

60 APPLIED LIFE SCIENCES↗

Recent developments in CID imaging

Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.

Michon, G. J.↗

Toward Adaptive X-Ray Telescopes

Future x-ray observatories will require high-resolution (less than 1 inch) optics with very-large-aperture (greater than 25 square meter) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the surface areal density of the grazing-incidence mirrors to about 1 kilogram per square meter or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve adaptive (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, adaptive optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Generation-X (Gen-X) concept studies in the United States, and the Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom. This paper discusses relevant technological issues and summarizes progress toward adaptive x-ray telescopes.

O'Dell, Stephen L.↗

Detecting Protostellar Jets with the Goddard Fabry-Perot Coronagraph, and Modification for Adaptive Optics

The Goddard Fabry-Perot has been used at the Apache Point Observatory 3.5-m telescope to diagnose jets from young Herbig Ae (HD163296) and T Tauri stars (DL Tau and CW Tau), detected by the Space Telescope Imaging Spectrograph coronagraph on the Hubble Space Telescope. The additional spectral discrimination of the Fabry-Perot allows these faint jets to be detected from the ground, to obtain velocities and densities, and to find further extensions. In order to plan what measurements require space coronagraphs, we need to explore the extent to which coronagraphic detections can be made from the ground, including using adaptive optics. Modifications to the Fabry-Perot tunable narrow band coronagraph for possible use with the AEOS 3.65-m telescope will be described.

Woodgate, Bruce E.↗

Detecting protostellar jets with the Goddard Fabry-Perot coronagraph, and modification for adaptive optics

The Goddard Fabry-Perot has been used at the Apache Point Observatory 3.5-m telescope to diagnose jets from young Herbig Ae (HD163296) and T Tauri stars (DL Tau and CW Tau), detected by the Space Telescope Imaging Spectrograph coronagraph on the Hubble Space Telescope. The additional spectral discrimination of the Fabry-Perot allows these faint jets to be detected from the ground, to obtain velocities and densities, and to find further extensions. In order to plan what measurements require space coronagraphs, we need to explore the extent to which coronagraphic detections can be made from the ground, including using adaptive optics. Modifications to the Fabry-Perot tunable narrow band coronagraph for possible use with the AEOS 3.65-m telescope will be described.

Woodgate, Bruce E.↗

Implementation of a New Method for Dynamic Multileaf Collimator Tracking of Prostate Motion in Arc Radiotherapy Using a Single KV Imager

Purpose: To implement a method for real-time prostate motion estimation with a single kV imager during arc radiotherapy and to integrate it with dynamic multileaf collimator (DMLC) target tracking. Methods and Materials: An arc field with a circular aperture and 358 deg. gantry rotation was delivered to a motion phantom with a fiducial marker under continuous kV X-ray imaging at 5 Hz, perpendicular to the treatment beam. A pretreatment gantry rotation of 120 deg. in 20 sec with continuous imaging preceded the treatment. During treatment, each kV image was first used together with all previous images to estimate the three-dimensional (3D) target probability density function and then used together with this probability density function to estimate the 3D target position. The MLC aperture was then adapted to the estimated 3D target position. Tracking was performed with five patient-measured prostate trajectories that represented characteristic prostate motion patterns. Two data sets were recorded during tracking: (1) the estimated 3D target positions, for off-line comparison with the actual phantom motion; and (2) continuous portal images, for independent off-line calculation of the 2D tracking error as the positional difference between the marker and the MLC aperture center in each portal image. All experiments were also made with 1- Hz kV imaging. Results: The mean 3D root-mean-square error of the trajectory estimation was 0.6 mm. The mean root-mean-square tracking error was 0.7 mm, both parallel and perpendicular to the MLC. The accuracy degraded slightly for 1- Hz imaging. Conclusions: Single-imager DMLC prostate tracking that allows arbitrary beam modulation during arc radiotherapy was implemented. It has submillimeter accuracy for most prostate motion types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A spectral identification technique for adaptive attitude control and pointing of the Space Telescope

The Space Telescope is a 2.4 m class aperture optical telescope having near-diffraction-limited performance. It will be placed into earth orbit by 1980 via the Space Shuttle. The problem considered is how to achieve negligible degradation of the astronomy imaging capability (to 0.005 arc second) due to smearing by pointing motions during observations. Initially, pointing instability sources were identified and a linear stability was used to assess the magnitude of elastic body modes and to design control system compensation regions necessary for subsequent adaptive control. A spectral identification technique for this adaptive attitude control and pointing has been investigated that will alleviate requirements for comprehensive dynamic ground testing. Typical all-digital simulation results describing motions of the telescope line of sight are presented.

Teuber, D. L.↗

Automated, Unmanned Detection and Quantification of Fugitive Methane Emissions

Compressor stations used to move natural gas are one of the largest sources of fugitive methane emissions in the midstream sector, accounting for approximately 50% of all fugitive emissions (Zimmerle et al., 2015). This problem is most widespread at reciprocating compressors (Subramanian et al., 2015) where faulty seals are a key contributor to methane emissions (Johnson et al., 2015). As such, there is a significant need for a robust technology that could provide an early indication of an unexpected emission. Equally important, the technology needs to be able to account for biogenic versus anthropogenic sources of methane. One means of indirectly making this determination, is to leverage optical technologies that can autonomously pinpoint the source of such leaks. This presentation discusses recent work funded by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), focused on the development of an innovative remote sensing technology that can reliably and autonomously detect fugitive methane emissions in near real-time, using computer vision and deep learning. The technology called the Smart Methane Leak Detection (SLED/M) system was initially developed to monitor facilities such as compressor stations in a stationary, pan-tilt-zoom configuration. The system has recently been adapted to monitor facilities from an unmanned aerial system (UAS). The speed and maneuverability of UAS platforms are attractive to leak detection and repair program operators, but introduce several challenges. Many existing methane detection algorithms rely on mostly static backgrounds becoming unusable with motion. In addition, top-down views of fugitive methane emissions present differently in Optical Gas Imagers (OGI) compared to looking across the plume. Our work has focused on overcoming these challenges, enhancing the operators ability to detect methane emissions, and pinpoint their sources. Another recent adaptation to SLED/M is the ability to quantify methane emissions using passive sensors (OGI, thermal camera), environmental conditions, plume modeling, and deep learning. SLED/M advances the state-of-the-art for methane emission detection and quantification by focusing on three key critical criteria for effective methane emission mitigation: (1) autonomy (no need for a human to be in the loop), (2) high reliability (low false alarm rates), and (3) real-time performance. Results from this work will be presented.

03 NATURAL GAS↗

Palomar and Table Mountain Observations of 9P/Tempel 1 during the Deep Impact Encounter: First Results

We present the first results of the Palomar Adaptive Optics observations taken during the Deep Impact encounter with 9P/Tempel 1 in July 2005. We have combined the Palomar near-IR imaging data with our visual wavelength images obtained simultaneously at JPL's Table Mountain Observatory to cover the total wavelength range from 0.4 to 2.3 micrometers in the B, V, R, I, J, H, and K filter bands, spanning the dates from 2005 July 03-07.We also include in our overall analysis images taken on the pre-encounter dates of June 1 and June 15, 2005. The broad wavelength range of our observations, along with high temporal resolution, near-IR sensitivity, and spatial resolution of our imaging, have enabled us to place constraints on the temperature of the impact flash and incandescent plume of greater than 700 K, and to provide mean dust velocities of order 197 +/- 16 m/s approximately 1.25 h after impact derived from our 1.64 micro observations. Our ejected dust mass estimates, as derived from our near-IR observations, are an order of magnitude less than those previously reported for visual wavelength observations.

Comet Tempel-1↗

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗

Marine Corps Base Camp Lejeune Geospatial Marsh Model: Habitat Maps

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of encroachment pressures in surrounding areas, impairments due to other anthropogenic disturbances, and changes in climate and sea level. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and also optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the second 5 years of the program (DCERP2) are presented in the DCERP2 Final Report.There were four overarching objectives of DCERP2. The first objective was to understand the effects of climate change impacts, including warming temperatures, variability in the hydrological cycle, storm events, and sea level rise on the coastal ecosystems at MCBCL from observations and measurements made over the 10-year program. The second objective was to understand the carbon cycle of the coastal and terrestrial ecosystems at MCBCL through a highly integrated sampling program. The third objective was to develop models, tools, and indicators to evaluate current and projected future ecosystem state changes and translate scientific findings into actionable information for installation managers. The last objective was to recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.This data package contains PNGs (images) of habitat maps (key is provided as single PNG) for Freeman, Traps, and French marsh modeling domains in the target years 2013 (initial), 2035, 2065, & 2100 after modeling marsh under the five SLR scenarios provided by the base.

54 ENVIRONMENTAL SCIENCES↗

Geological-structural interpretation using products of remote sensing in the region of Carrancas, Minas Gerais, Brazil

The efficiency of some criteria developed for the utilization of small scale and low resolution remote sensing products to map geological and structural features was demonstrated. Those criteria were adapted from the Logical Method of Photointerpretation which consists of textural qualitative analysis of landforms and drainage net patterns. LANDSAT images of channel 5 and 7, 4 LANDSAT-RBV scenes, and 1 radar mosiac were utilized. The region of study is characterized by supracrustal metassediments (quartzites and micaschist) folded according to a "zig-zag" pattern and gnaissic basement. Lithological-structural definition was considered outstanding when compared to data acquired during field work, bibliographic data and geologic maps acquired in larger scales.

Parada, N. D. J.↗

A parallel row-based algorithm with error control for standard-cell replacement on a hypercube multiprocessor

A new row-based parallel algorithm for standard-cell placement targeted for execution on a hypercube multiprocessor is presented. Key features of this implementation include a dynamic simulated-annealing schedule, row-partitioning of the VLSI chip image, and two novel new approaches to controlling error in parallel cell-placement algorithms; Heuristic Cell-Coloring and Adaptive (Parallel Move) Sequence Control. Heuristic Cell-Coloring identifies sets of noninteracting cells that can be moved repeatedly, and in parallel, with no buildup of error in the placement cost. Adaptive Sequence Control allows multiple parallel cell moves to take place between global cell-position updates. This feedback mechanism is based on an error bound derived analytically from the traditional annealing move-acceptance profile. Placement results are presented for real industry circuits and the performance is summarized of an implementation on the Intel iPSC/2 Hypercube. The runtime of this algorithm is 5 to 16 times faster than a previous program developed for the Hypercube, while producing equivalent quality placement. An integrated place and route program for the Intel iPSC/2 Hypercube is currently being developed.

Sargent, Jeff Scott↗

A parallel row-based algorithm for standard cell placement with integrated error control

A new row-based parallel algorithm for standard-cell placement targeted for execution on a hypercube multiprocessor is presented. Key features of this implementation include a dynamic simulated-annealing schedule, row-partitioning of the VLSI chip image, and two novel approaches to control error in parallel cell-placement algorithms: (1) Heuristic Cell-Coloring; (2) Adaptive Sequence Length Control.

Sargent, Jeff S.↗