Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Collaborative Visualization for Large-Scale Accelerator Electromagnetic Modeling (Final Report)

This report contains the comprehensive summary of the work performed on the SBIR Phase II, Collaborative Visualization for Large-Scale Accelerator Electromagnetic Modeling at Kitware Inc. in collaboration with Stanford Linear Accelerator Center (SLAC). The goal of the work was to develop collaborative visualization tools for large-scale data as illustrated in the figure below. The solutions we proposed address the typical problems faced by geographicallyand organizationally-separated research and engineering teams, who produce large data (either through simulation or experimental measurement) and wish to work together to analyze and understand their data. Because the data is large, we expect that it cannot be easily transported to each team member's work site, and that the visualization server must reside near the data. Further, we also expect that each work site has heterogeneous resources: some with large computing clients, tiled (or large) displays and high bandwidth; others sites as simple as a team member on a laptop computer. Our solution is based on the open-source, widely used ParaView large-data visualization application. We extended this tool to support multiple collaborative clients who may locally visualize data, and then periodically rejoin and synchronize with the group to discuss their findings. Options for managing session control, adding annotation, and defining the visualization pipeline, among others, were incorporated. We also developed and deployed a Web visualization framework based on ParaView that enables the Web browser to act as a participating client in a collaborative session. The ParaView Web Visualization framework leverages various Web technologies including WebGL, JavaScript, Java and Flash to enable interactive 3D visualization over the web using ParaView as the visualization server. We steered the development of this technology by teaming with the SLAC National Accelerator Laboratory. SLAC has a computationally-intensive problem important to the nations scientific progress as described shortly. Further, SLAC researchers routinely generate massive amounts of data, and frequently collaborate with other researchers located around the world. Thus SLAC is an ideal teammate through which to develop, test and deploy this technology. The nature of the datasets generated by simulations performed at SLAC presented unique visualization challenges especially when dealing with higher-order elements that were addressed during this Phase II. During this Phase II, we have developed a strong platform for collaborative visualization based on ParaView. We have developed and deployed a ParaView Web Visualization framework that can be used for effective collaboration over the Web. Collaborating and visualizing over the Web presents the community with unique opportunities for sharing and accessing visualization and HPC resources that hitherto with either inaccessible or difficult to use. The technology we developed in here will alleviate both these issues as it becomes widely deployed and adopted.

43 PARTICLE ACCELERATORS↗

Summary Report of Working Group 4: Plasma Wakefield Acceleration

This report gives a guide to the discussions of Working Group 4 of the 2010 Advanced Accelerator Concepts Workshop, which was devoted to theory, simulation and experimental issues associated with plasma wakefield acceleration (PWFA). Sessions were organized thematically in this group, concentrating on broad issues of: exploitation of future facilities such as FACET; pushing the accelerating gradient beyond the current frontier, to over a TeV/m; use of positively charged beams to drive plasma wakes; resonant excitation of the PWFA with pulse trains; beam-plasma instabilities; and injection and capture of electron beams into PWFA systems.

43 PARTICLE ACCELERATORS↗

Performance Limiting Effects in X-Band Accelerators

Acceleration gradient is a critical parameter for the design of future TeV-scale linear colliders. The major obstacle to higher gradient in room-temperature accelerators is rf breakdown, which is still a very mysterious phenomenon that depends on the geometry and material of the accelerator as well as the input power and operating frequency. Pulsed heating has been associated with breakdown for many years; however, there have been no experiments that clearly separate field and heating effects on the breakdown rate. Recently, such experiments have been performed at SLAC with both standing-wave and traveling-wave structures. These experiments have demonstrated that pulsed heating is limiting the gradient. Nevertheless the X-band structures breakdown studies show damage to the iris surfaces in locations of high electric field rather than of high magnetic field after thousands of breakdowns. It is not yet clear how the relative roles of electric field, magnetic field, and heating factor into the damage caused by rf breakdown. Thus, a dual-moded cavity has been designed to better study the electric field, magnetic field, and pulsed heating effects on breakdown damage.

43 PARTICLE ACCELERATORS↗

International X-Band Linear Collider Accelerator Structure R&D

For more than fifteen years before the International Technology Recommendation Panel (ITRP) decision in August, 2004, there were intensive R&D activities and broad international collaboration among the groups at SLAC, KEK, FNAL, LLNL and other labs for the room temperature X-Band accelerator structures. The goal was to provide an optimized design of the main linac structure for the NLC (Next Linear Collider) or GLC (Global Linear Collider). There have been two major challenges in developing X-band accelerator structures for the linear colliders. The first is to demonstrate stable, long-term operation at the high gradient (65 MV/m) that is required to optimize the machine cost. The second is to strongly suppress the beam induced long-range wakefields, which is required to achieve high luminosity. More than thirty X-band accelerator structures with various RF parameters, cavity shapes and coupler types have been fabricated and tested since 1989. A summary of the main achievements and experiences are presented in this talk including the structure design, manufacturing techniques, high power performance, and other structure related issues. Also, the new progress in collaborating with the CLIC, high gradient structures and X-Band structure applications for RF deflectors and others are briefly introduced.

43 PARTICLE ACCELERATORS↗

Development of high gradient laser wakefield accelerators towards nuclear detection applications at LBNL

Compact high-energy linacs are important to applications including monochromatic gamma sources for nuclear material security applications. Recent laser wakefield accelerator experiments at LBNL demonstrated narrow energy spread beams, now with energies of up to 1 GeV in 3 cm using a plasma channel at low density. This demonstrates the production of GeV beams from devices much smaller than conventional linacs, and confirms the anticipated scaling of laser driven accelerators to GeV energies. Stable performance at 0.5 GeV was demonstrated. Experiments and simulations are in progress to control injection of particles into the wake and hence to improve beam quality and stability. Using plasma density gradients to control injection, stable beams at 1 MeV over days of operation, and with an order of magnitude lower absolute momentum spread than previously observed, have been demonstrated. New experiments are post-accelerating the beams from controlled injection experiments to increase beam quality and stability. Thomson scattering from such beams is being developed to provide collimated multi-MeV monoenergetic gamma sources for security applications from compact devices. Such sources can reduce dose to target and increase accuracy for applications including photofission and nuclear resonance fluorescence.

43 PARTICLE ACCELERATORS↗

AI-Ready Control System for the Fermilab Accelerator Complex

Reliable, high-intensity operation of the Fermilab Accelerator Complex is critical to the success of the Long-Baseline Neutrino Facility and Deep Underground Neutrino Experiment. We describe the requirements and infrastructure necessary to support routine use of artificial intelligence and machine learning (AI/ML) in the accelerator control system. Three capabilities are identified: a machine learning operations (MLOps) framework standardizing the lifecycle of AI/ML automation from data management through deployment and monitoring; a data quality framework defining and enforcing standards required to build trustworthy AI/ML applications; and workflow integration with large language models to assist physicists, engineers, and operators with information retrieval, code development, and routine analysis. Use cases spanning beam diagnostics, beam control, and support system automation illustrate the technical requirements across the complex.

43 PARTICLE ACCELERATORS↗

Accelerated Stress Testing of Perovskite Photovoltaic Modules: Differentiating Degradation Modes with Electroluminescence Imaging

Herein, electroluminescence (EL) and thermal imaging are used to examine p–i–n metal halide perovskite (MHP) photovoltaic (PV) mini-modules (MA0.6FA0.4PbI3, 20 cells, 78 cm2) before and after indoor-accelerated stress testing or outdoor deployment. Distinct spatial patterns in the EL images emerge, which depend on the external stress conditions experienced by the mini-module. Imaging results highlight a distribution of dark speckle features that dominate after UV stress, attributed to widespread interfacial contact degradation. Lateral intensity gradients across cells dominate after thermal cycling (TC) stress, attributed to current crowding near scribe defects. While current–voltage analysis alone does not give full insight on the degradation process, this study shows that distinct degradation modes can be further defined by multimodal electro-optical imaging (i.e., EL combined with photoluminescence and dark lock-in thermography). Neither UV exposure nor TC-accelerated stress testing alone replicates the same degradation signatures observed after outdoor deployment, suggesting that multiple degradation modes occur under concurrent stressors outdoors. Finally, spatial characterization of degradation modes in MHP PV mini-modules before and after accelerated stress testing lays the groundwork for developing targeted accelerated stress testing procedures through comparison with outdoor aging.

14 SOLAR ENERGY↗

Occupation Time of a Randomly Accelerated Particle on the Positive Half Axis: Results for the First Five Moments

In the random acceleration process a point particle is accelerated by Gaussian white noise with zero mean. Although several fundamental statistical properties of the motion have been analyzed in detail, the statistics of occupation times is still not well understood. We consider the occupation or residence time T{sub +} on the positive x axis of a particle which is randomly accelerated on the unbounded x axis for a time t. The first two moments of T{sub +} were recently derived by Ouandji Boutcheng et al. (J Stat Mech 053213:1–10, 2016). With an alternate approach utilizing basis functions which have proved useful in other studies of randomly accelerated motion, results for the first five moments are obtained in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Corrosion Resistance of Ni-Co Coatings Prepared by Electrodeposition with Large Centrifugal Acceleration

A higher Co content in Ni-Co coatings leads to better corrosion resistance to a certain degree. In this paper, centrifugal acceleration was introduced in the electrodeposition of Ni-Co coatings in order to obtain improved Ni-Co coatings with high Co content. With different centrifugal accelerations, the Co content, morphology, preferred coating orientation, microhardness, and wear and corrosion resistance were examined. Under large centrifugal acceleration, a maximal Co content of 38.25% was obtained according to the EDS results, which was higher than that obtained using normal electrodeposition. The SEM images indicated that the morphology of the prepared Ni-Co coatings with the highest Co content was smoothened. In addition, the microhardness of Ni-Co coatings with increased Co content was improved to about 530HV, which was hardly achieved under normal electrodeposition. Most of all, based on the polarization curve and EIS results, the corrosion resistance was significantly enhanced as the Co content reached the maximum. In general, corrosion resistance of the deposited Ni-Co coatings can be improved with large centrifugal acceleration.

36 MATERIALS SCIENCE↗

A charged particle in a homogeneous magnetic field accelerated by a time-periodic Aharonov-Bohm flux

We consider a nonrelativistic quantum charged particle moving on a plane under the influence of a uniform magnetic field and driven by a periodically time-dependent Aharonov-Bohm flux. We observe an acceleration effect in the case when the Aharonov-Bohm flux depends on time as a sinusoidal function whose frequency is in resonance with the cyclotron frequency. In particular, the energy of the particle increases linearly for large times. An explicit formula for the acceleration rate is derived with the aid of the quantum averaging method, and then it is checked against a numerical solution and a very good agreement is found. - Highlights: > A nonrelativistic quantum charged particle on a plane. > A homogeneous magnetic field and a periodically time-dependent Aharonov-Bohm flux. > The quantum averaging method applied to a time-dependent system. > A resonance of the AB flux with the cyclotron frequency. > An acceleration with linearly increasing energy; a formula for the acceleration rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-interaction in the Bopp–Podolsky electrodynamics: Can the observable mass of a charged particle depend on its acceleration?

In this paper we obtain the expression for the self-force in the model with the Lagrangian containing additional terms, quadratic in Maxwell tensor derivatives (so-called Bopp–Podolsky electrodynamics). Features of this force are analyzed for various limiting cases. When a charged particle moves along straight line with a uniform acceleration, an explicit formula is found. In the framework of the considered model, an observable renormalized particle mass is shown to depend on its acceleration. This dependence allows, in principle, to extract experimentally a value of the particle bare mass. -- Highlights: •An expression for the self-force in the Bopp–Podolsky electrodynamics is given. •For a uniformly accelerated charged particle an explicit formula for the self-force is obtained. •Dependence between the observable mass of a charged particle and its acceleration is found.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physico-chemical mechanisms involved in the acceleration of the hydration of calcium sulfoaluminate cement by lithium ions

This work investigates the influence of lithium ions on the hydration at 25 °C of two calcium sulfoaluminate (CSA) cements comprising 0 or 10% gypsum. Small concentrations of lithium salts (LiOH, LiNO{sub 3}) accelerate the early hydration of both CSA cements either in paste or in diluted and stirred suspension. The effect of the lithium cation is much stronger than its counter-ion. Hydration is accelerated by an increase in the lithium concentration up to 30 μmol Li/g of the used CSA cement (with a high ye'elimite content), and then levels off. The postulated mechanism relies on a fast precipitation of amorphous Li-containing Al(OH){sub 3}, which acts as seeds for accelerating the precipitation of amorphous Al(OH){sub 3} that speeds up the whole hydration process. This process seems to be closely related to the one involved in the acceleration of the hydration of calcium aluminate cement by lithium ions.

36 MATERIALS SCIENCE↗

Stereoscopic detection of hot spots in superfluid 4 He (He II) for accelerator-cavity diagnosis

Superconducting radio-frequency (SRF) cavities cooled by superfluid 4He (He II) are building blocks of many modern particle accelerators due to their high quality factor. However, Joule heating from sub-millimeter surface defects on cavities can lead to cavity quenching, which limits the maximum acceleration gradient of the accelerators. Developing a non-contacting detection technology to accurately locate these surface hot spots is the key to improve the performance of SRF cavities and hence the accelerators. In a recent proof-of-concept experiment, we demonstrated that a molecular tagging velocimetry (MTV) technique based on the tracking of a He molecular tracer line created nearby a surface hot spot in He II can be utilized to locate the hot spot. In order to make this technique practically useful, here we describe our further development of a stereoscopic MTV setup for tracking the tracer line’s motion in three-dimensional (3D) space. We simulate a quench spot by applying a transient voltage pulse to a small heater mounted on a substrate plate. Images of the drifted tracer line, taken with two cameras from orthogonal directions, are used to reconstruct the line profile in 3D space. Here, a new algorithm for analyzing the 3D line profile is developed, which incorporates the finite size effect of the heater. We show that the center location of the heater can be reproduced on the substrate surface with an uncertainty of only a few hundred microns, thereby proving the practicability of this method.

43 PARTICLE ACCELERATORS↗

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance

Purpose: To determine clinic-specific linear accelerator quality assurance (QA) TG-142 test frequencies, to maximize physicist time efficiency and patient treatment quality. Methods and Materials: A novel quantitative approach to failure mode and effect analysis is proposed. Nine linear accelerator-years of QA records provided data on failure occurrence rates. The severity of test failure was modeled by introducing corresponding errors into head and neck intensity modulated radiation therapy treatment plans. The relative risk of daily linear accelerator QA was calculated as a function of frequency of test performance. Results: Although the failure severity was greatest for daily imaging QA (imaging vs treatment isocenter and imaging positioning/repositioning), the failure occurrence rate was greatest for output and laser testing. The composite ranking results suggest that performing output and lasers tests daily, imaging versus treatment isocenter and imaging positioning/repositioning tests weekly, and optical distance indicator and jaws versus light field tests biweekly would be acceptable for non-stereotactic radiosurgery/stereotactic body radiation therapy linear accelerators. Conclusions: Failure mode and effect analysis is a useful tool to determine the relative importance of QA tests from TG-142. Because there are practical time limitations on how many QA tests can be performed, this analysis highlights which tests are the most important and suggests the frequency of testing based on each test's risk priority number.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Leveraging Anderson Acceleration for improved convergence of iterative solutions to transport systems

In this note we demonstrate that using Anderson Acceleration (AA) in place of a standard Picard iteration can not only increase the convergence rate but also make the iteration more robust for two transport applications. We also compare the convergence acceleration provided by AA to that provided by moment-based acceleration methods. Additionally, we demonstrate that those two acceleration methods can be used together in a nested fashion. We begin by describing the AA algorithm. At this point, we will describe two application problems, one from neutronics and one from plasma physics, on which we will apply AA. We provide computational results which highlight the benefits of using AA, namely that we can compute solutions using fewer function evaluations, larger time-steps, and achieve a more robust iteration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data-driven acceleration of thermal radiation transfer calculations with the dynamic mode decomposition and a sequential singular value decomposition

In this work, we present a method for accelerating discrete ordinates radiative transfer calculations for radiative transfer. Our method works with nonlinear positivity fixes, in contrast to most acceleration schemes. The method is based on the dynamic mode decomposition (DMD) and using a sequence of rank-one updates to compute the singular value decomposition needed for DMD. Using a sequential method allows us to automatically determine the number of solution vectors to include in the DMD acceleration. We present results for slab geometry discrete ordinates calculations with the standard temperature linearization. Compared with positive source iteration, our results demonstrate that our acceleration method reduces the number of transport sweeps required to solve the problem by a factor of about 3 on a standard diffusive Marshak wave problem, a factor of several thousand on a cooling problem where the effective scattering ratio approaches unity, and a factor of 20 improvement in a realistic, multimaterial radiating shock problem.

97 MATHEMATICS AND COMPUTING↗

Advancement of LANSCE accelerator facility as a 1-MW Fusion Prototypic Neutron Source

The Fusion Prototypic Neutron Source (FPNS) is considered to be a testbed for scientific understanding of material degradation in future nuclear fusion reactors (Zinkle and Moeslang, 2013; Summary Report on the FPNS Workshop, 2018; Pitcher et al., 2019). The primary mission of FPNS is to provide a damage rate in iron samples of 8-11 dpa/calendar year with He/dpa ratio of 10 appm in irradiation volume of 50 cm 3 or larger with irradiation temperature 300–1000 °C and flux gradient less than 20%/cm in the plane of the sample. The Los Alamos Neutron Science Center (LANSCE) is an attractive candidate for the FPNS project. The Accelerator Facility was designed and operated for an extended period as a 0.8-MW Meson Factory. The existing setup of the LANSCE accelerator complex can nearly fulfill requirements of the fusion neutron source station. The primary function of the upgraded accelerator systems is the safe and reliable delivery of a 1.25-mA continuous proton beam current at 800-MeV beam energy from the switchyard to the target assembly to create 1 MW power of proton beam interacting with a solid tungsten target. The present study describes existing accelerator setup and further development required to meet the needs of FPNS project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗