At least 1,603 records · Page 89

Free convection in enclosures exposed to compressive heating

An experimental study of heat transfer in a vertical annulus and a three-dimensional gap used to establish the influence of compressive heating on the convective process in enclosures is presented. Test runs were made using helium gas with compressive rates of 6, 15, and 30 psi/min. Temperature and pressure histories were reduced to film coefficients based on nodal modeling of the test geometries. The data are correlated in terms of free convection parameters. The heat transfer correlations show virtually no influence of compression rate and only a slight dependence on geometry. The correlations will be applied to the design of a vented Galileo mission descent module parachuting into the Jupiter atmosphere.

Bobco, R. P.↗

A hybrid water-splitting cycle using copper sulfate and mixed copper oxides

The Institute of Gas Technology has derived and developed a hybrid thermochemical water-splitting cycle based on mixed copper oxides and copper sulfate. Similar to other metal oxide-metal sulfate cycles that use a metal oxide to 'concentrate' electrolytically produced sulfuric acid, this cycle offers the advantage of producing oxygen (to be vented) and sulfur dioxide (to be recycled) in separate steps, thereby eliminating the need of another step to separate these gases. The conceptual process flow-sheet efficiency of the cycle promises to exceed 50%. It has been completely demonstrated in the laboratory with recycled materials. Research in the electrochemical oxidation of sulfur dioxide to produce sulfuric acid and hydrogen performed at IGT indicates that the cell performance goals of 200 mA/sq cm at 0.5 V will be attainable using relatively inexpensive electrode materials.

Schreiber, J. D.↗

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

Source record↗

Development and implementation of Shuttle/IUS proximity operations flight design software

The High Fidelity Relative Motion Program (HFRMP), a trajectory/attitude numerical integration program, was developed and implemented on the MPAD HP-9825A desk top computer systems. A solar and a lunar ephemeris is included in the HFRMP along with models of the oblate Earth, a rotating atmosphere, the orbiter's OMS/RCS/DAP system, orbiter vents, rotor dynamics, and upper stage propulsion systems. Although designed primarily for the analysis of proximity operations, it is useful in other areas such as attitude/stability analysis, propulsive consumables estimation, and trajector perturbation studies. An unique identification was assigned to each of the various configurations of the HFRMP that were developed to test new techniques and algorithms are briefly described. These include the HFRMP Versions 03H, 03M, 03T, 03U, and 05D. Development of orbiter/upper stage separation techniques including flight design support for the TDRS-A and Galileo deployment flights and design of standard maneuver sequences is discussed. Also, the development and implementation of the Euler angle conversion program is briefly addressed.

Wilson, S. W.↗

Study of a solid hydrogen cooler for spacecraft instruments and sensors

The results of tests and studies to investigate the utilization of solid hydrogen for cooling of spacecraft instruments and sensors are presented. The results are presented in two sections; the first describing the tests in which an existing single stage solid cooler was filled and tested with solid hydrogen and the second which describes the analysis and design of a catalytic converter which will be tested in the vent line of the cooler.

Sherman, A.↗

Low cost cryostat

A cryostat for use in a low or a substantially gravity-free environment adapted to cool an experiment through the use of helium 2, or helium in its super fluid state is characterized by a number of interchangeable daughter dewars and helium supply or mother dewar. A low pressure venting system is provided for converting helium contained in the mother dewar to a superfluid state for use as a primary cryogen. Each daughter dewar is adapted to be removably mounted in mated relation on the mother dewar and is characterized by support for an experiment package, a source of helium to be employed as a secondary cryogen. A heat pipe is suspended from each daughter dewar and adapted to be extended into the mother dewar for facilitating cooling of the secondary cryogen. A transfer of heat from the package to the primary cryogen, via the secondary cryogen, is accommodated as a film flow of helium 2 progresses from the heat pipe to the experiment dewar.

Stephens, J. B.↗

Continuous coal processing method

A coal pump is provided in which solid coal is heated in the barrel of an extruder under pressure to a temperature at which the coal assumes plastic properties. The coal is continuously extruded, without static zones, using, for example, screw extrusion preferably without venting through a reduced diameter die to form a dispersed spray. As a result, the dispersed coal may be continuously injected into vessels or combustors at any pressure up to the maximum pressure developed in the extrusion device. The coal may be premixed with other materials such as desulfurization aids or reducible metal ores so that reactions occur, during or after conversion to its plastic state. Alternatively, the coal may be processed and caused to react after extrusion, through the die, with, for example, liquid oxidizers, whereby a coal reactor is provided.

Ryason, P. R.↗

Catastrophic event modeling

A mathematical model for the catastrophic failures (venting or explosion of the cell) in lithium thionyl chloride batteries is presented. The phenomenology of the various processes leading to cell failure is reviewed.

Frank, H. A.↗

Evaluation of anti-freeze viscosity modifier for potential external tank applications

Viscosity modifiers and gelling agents were evaluated in combination with ethylene glycol and dimethyl sulfoxide water eutectics. Pectin and agarose are found to gel these eutectics effectively in low concentration, but the anti-freeze protection afforded by these compositions is found to be marginal in simulations of the intended applications. Oxygen vent shutters and vertical metallic surfaces were simulated, with water supplied as a spray, dropwise, and by condensation from the air.

Lynn, R. O. L.↗

A system for model access in tunnels with an unbreathable test medium

In many specialty wind tunnels, test gases other than ambient air are used to meet special testing requirements. A typical example is the use of freon as the test gas to achieve a realistic density ratio between gas and model for exploring flutter stability boundaries. Another example is the use of pressurized air to elevate the stream density and enhance Reynolds number or dynamic pressure simulation. Such specialty tunnels require a system of access o the model which will allow services and changes to the model without exposing personnel to the unnatural and perhaps hostile environment or requiring the venting and purging of the entire tunnel circuit. This paper will describe the plenum and model access systems for the forthcoming U.S. National Transonic facility where gaseous nitrogen (N2) at temperatures between 338 and 78 K and at pressures to 9 bars is used as the test medium. The operation at cold temperatures imposes some additional requirements which make the access systems more difficult to design and time consuming to operate than for conventional wind tunnels.

Howell, R. R.↗

Characterization of aerosols from eruptions of Mount St. Helens

Measurements of mass concentration and size distribution of aerosols from eruptions of Mount St. Helens as well as morphological and elemental analyses were obtained between 7 April and 7 August 1980. In situ measurements were made in early phreatic and later, minor phreatomagmatic eruption clouds near the vent of the volcano and in plumes injected into the stratosphere from the major eruptions of 18 and 25 May. The phreatic aerosol was characterized by an essentially monomodal size distribution dominated by silicate particles larger than 10 micrometers in diameter. The phreatomagmatic eruption cloud was multimodal; the large size mode consisted of silicate particles and the small size modes were made up of mixtures of sulfuric acid and silicate particles. The stratospheric aerosol from the main eruption exhibited a characteristic narrow single mode with particles less than 1 micrometer in diameter and nearly all of the mass made up of sulfuric acid droplets.

Chuan, R. L.↗

Volcanic origin of the eruptive plumes on Io

A quadruple long exposure of Io in eclipse exhibits faint auroral emission from the eruptive plumes. No luminous spots in the vents, predicted by Gold, were observed. Heat from the interior of Io appears to be the predominant source of energy in the plume.

Cook, A. F.↗

Near-surface flow of volcanic gases on Io

Significant near-surface flow of gas several hundred kilometers from Pele (Plume 1) on Io is indicated by a series of bright, elongate albedo markings. Particles produced at small, local vents are apparently carried as much as 70 km farther 'downwind' from Pele. The gas densities and velocities necessary to suspend 0.1 to 10 micron particles at such a distance imply mass flow rates of 10 to the 7th - 10 to the 9th g/sec. Such flow rates are consistent with other estimates of mass transport by the plume. The large flow rates so far from the source allow an estimate of the rate of resurfacing of Io by lava flows and pyroclastics that is independent of estimates based on meteorite flux or on the amount of solids carried within the plumes themselves.

Lee, S. W.↗

Thermal subcoolers for low-thrust chemical orbital transfer vehicles

A system alternative to pressurization for providing net positive suction pressure (NPSP) to the main engine of a low-thrust cryogenic stage has been conceptually designed and analyzed. Thermal subcoolers (heat exchangers) provide required NPSP levels by using throttled vent fluid to subcool propellant delivered to the engine. The study analyzed and sized subcoolers that provide NPSP levels of 0.5 to 12.0 psi for liquid oxygen, liquid hydrogen, and liquid methane propellants. The study was part of an overall investigation to compare pressurization and other methods of providing NPSP for low-thrust vehicles.

Pleasant, R. L.↗

Method for retarding dye fading during archival storage of developed color photographic film

Dye fading during archival storage of developed color photographic film is retarded by placing the film in a sealed, opaque vault, introducing a dry, pressurized inert gas into the vault while the latter is vented, and sealing the vault after the air within the vault has been purged and replaced by the inert gas. Preferably, the gas is nitrogen; and the vault is stored at a temperature below room temperature to preserve the color photographic emulsions on the film contained within the vault. For short-term storage, sodium thiocyanate pads charged with water are placed within the vault. For long term storage, the interior of the vault is kept at a low relative humidity.

Hoover, R. B.↗

Cryogenic fluid management experiment

The cryogenic fluid management experiment (CFME), designed to characterize subcritical liquid hydrogen storage and expulsion in the low-q space environment, is discussed. The experiment utilizes a fine mesh screen fluid management device to accomplish gas-free liquid expulsion and a thermodynamic vent system to intercept heat leak and control tank pressure. The experiment design evolved from a single flight prototype to provision for a multimission (up to 7) capability. A detailed design of the CFME, a dynamic test article, and dedicated ground support equipment were generated. All materials and parts were identified, and components were selected and specifications prepared. Long lead titanium pressurant spheres and the flight tape recorder and ground reproduce unit were procured. Experiment integration with the shuttle orbiter, Spacelab, and KSC ground operations was coordinated with the appropriate NASA centers, and experiment interfaces were defined. Phase 1 ground and flight safety reviews were conducted. Costs were estimated for fabrication and assembly of the CFME, which will become the storage and supply tank for a cryogenic fluid management facility to investigate fluid management in space.

Eberhardt, R. N.↗

A unified thermal and vertical trajectory model for the prediction of high altitude balloon performance

A computer model for the prediction of the trajectory and thermal behavior of zero-pressure high altitude balloon was developed. In accord with flight data, the model permits radiative emission and absorption of the lifting gas and daytime gas temperatures above that of the balloon film. It also includes ballasting, venting, and valving. Predictions obtained with the model are compared with flight data from several flights and newly discovered features are discussed.

Carlson, L. A.↗

Discharge of 1400 AH lithium thionyl chloride cells into voltage reversal

The development of a high energy density battery is discussed. Tests were conducted on a 1400 AH cell and they include: drop tests, crush tests, vibration and shock tests, hydrostatic pressure effects, charge current tests, and discharge tests. None of these tests led to a venting or explosion of the cell. Criteria are presented for extending RV safety of a 1400 AH cell.