Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Isotopic Studies for Tracking Biogenic Carbon during Co-processing of Biomass and Vacuum Gas Oil

Co-processing bio-oils with petroleum-derived feeds in the existing multitrillion dollar refining and distribution infrastructure is an attractive option for introducing renewable energy into the fuels marketplace. Considerable research on co-processing bio-oils and vacuum gas oil (VGO) in fluid catalytic cracking units (FCC) using equilibrium catalysts (E-Cats) demonstrated that biomass-derived molecules decreased activity of and increased carbon laydown on E-Cat. In this work, 13 C-labeled biomass was co-processed with VGO using either an E-Cat or a proprietary zeolite Johnson Matthey catalyst (CP758), which is optimzed for upgrading biomass vapors in a riser reactor, to evaluate the fate of biogenic carbon in FCC products. The results from both catalysts indicate that biogenic carbon was incorporated into alkenes and aromatic hydrocarbons. While no biogenic carbon was found in linear alkanes, it was observed in cycloalkanes during experiments with E-Cat but not with CP758. All produced CO2 was biogenic as was most of the carbon laydown on the catalysts. Several partially deoxygenated biomass compounds, such as alkylphenols and benzofurans, unexpectedly contained small amounts of carbon from VGO. Although this study was conducted with labeled biomass and not bio-oil, it provides insights to reaction mechanisms for co-processing bio-oil and VGO in an FCC, which is required to develop catalysts that efficiently convert bio-oil components during FCC co-processing. This work also demonstrates that comprehensive catalyst development utilizing both biomass- and fossil-derived feeds is required to maximize the incorporation of biogenic carbon into transportation fuels.

09 BIOMASS FUELS↗

Application usability levels: a framework for tracking project product progress

The space physics community continues to grow and become both more interdisciplinary and more intertwined with commercial and government operations. This has created a need for a framework to easily identify what projects can be used for specific applications and how close the tool is to routine autonomous or on-demand implementation and operation. We propose the Application Usability Level (AUL) framework and publicizing AULs to help the community quantify the progress of successful applications, metrics, and validation efforts. This framework will also aid the scientific community by supplying the type of information needed to build off of previously published work and publicizing the applications and requirements needed by the user communities. In this paper, we define the AUL framework, outline the milestones required for progression to higher AULs, and provide example projects utilizing the AUL framework. This work has been completed as part of the activities of the Assessment of Understanding and Quantifying Progress working group which is part of the International Forum for Space Weather Capabilities Assessment.

79 ASTRONOMY AND ASTROPHYSICS↗

Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO{sub 3}){sub 4} ⋅ 5H{sub 2}O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-based tracking for the CMS Level-1 trigger using the tracklet algorithm

The high instantaneous luminosities expected following the upgrade of the Large Hadron Collider (LHC) to the High-Luminosity LHC (HL-LHC) pose major experimental challenges for the CMS experiment. A central component to allow efficient operation under these conditions is the reconstruction of charged particle trajectories and their inclusion in the hardware based trigger system. There are many challenges involved in achieving this: a large input data rate of about 20–40 Tb/s; processing a new batch of input data every 25 ns, each consisting of about 15,000 precise position measurements and rough transverse momentum measurements of particles (“stubs”); performing the pattern recognition on these stubs to find the trajectories; and producing the list of trajectory parameters within 4 µs. Here, this paper describes a proposed solution to this problem, specifically, it presents a novel approach to pattern recognition and charged particle trajectory reconstruction using an all-FPGA solution. The results of an end-to-end demonstrator system, based on Xilinx Virtex-7 FPGAs, that meets timing and performance requirements are presented along with a further improved, optimized version of the algorithm together with its corresponding expected performance.

47 OTHER INSTRUMENTATION↗

Quantum pattern recognition algorithms for charged particle tracking

High-energy physics is facing a daunting computing challenge with the large datasets expected from the upcoming High-Luminosity Large Hadron Collider in the next decade and even more so at future colliders. A key challenge in the reconstruction of events of simulated data and collision data is the pattern recognition algorithms used to determine the trajectories of charged particles. The field of quantum computing shows promise for transformative capabilities and is going through a cycle of rapid development and hence might provide a solution to this challenge. This article reviews current studies of quantum computers for charged particle pattern recognition in high-energy physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the top-quark mass using charged particle tracking

We present three measurements of the top-quark mass in the lepton plus jets channel with approximately 1.9 fb{sup -1} of integrated luminosity collected with the CDF II detector using quantities with minimal dependence on the jet energy scale. One measurement exploits the transverse decay length of b-tagged jets to determine a top-quark mass of 166.9{sub -8.5}{sup +9.5}(stat){+-}2.9(syst) GeV/c{sup 2}, and another the transverse momentum of electrons and muons from W-boson decays to determine a top-quark mass of 173.5{sub -8.9}{sup +8.8}(stat){+-}3.8(syst) GeV/c{sup 2}. These quantities are combined in a third, simultaneous mass measurement to determine a top-quark mass of 170.7{+-}6.3(stat){+-}2.6(syst) GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Miniaturized Acoustic Transmitter for Marine Animal Tracking

Most marine renewable energy (MRE) technologies are still in their infancy. Many uncertainties remain regarding MRE systems’ impacts on the marine environment and species where they are deployed, which is one of the major hurdles for these systems to be widely adopted at a commercial scale. Currently, the primary technologies to monitor marine animals’ behavior around existing or potential MRE deployment sites are optical and acoustic imaging. However, these methods cannot identify individual animals and thus are less useful in identifying protected species and studying their behavior. Implantable acoustic transmitters with unique identification codes could serve as a complementary technology. To minimize potential bias introduced to the study results, the implanted transmitters must be sufficiently small and light to not affect the animals’ behavior while still having acceptable signal strengths and service life. Recently, we developed a new miniaturized acoustic transmitter that offers a significantly improved signal strength and service life (140 days [projected value] at a 5-s transmission interval) in a smaller and lighter package (0.45 g in the air), compared to the existing technologies. The detection range and detection efficiency of the new transmitter were tested in an actual marine environment and demonstrated a detection range of up to 330 m, a 65% improvement over the existing commercial counterparts operating at similar frequencies. Here, we report the design principles, performance, and manufacturing procedure of the transmitter. Finally, theoretical estimates of the detection range, the actual range, and detection efficiency results from the field testing are presented.

acoustic telemetry↗

SU-D-210-04: Using Radiotherapy Biomaterials to Brand and Track Deadly Cancer Cells

Purpose: Metastasis accounts for over 90% of all cancer associated suffering and death and arguably presents the most formidable challenges in cancer management. The detection of metastatic or rare circulating tumor cells (CTCs) in blood or lymph nodes remains a formidable technological challenge. In this study, we investigated the time needed to label each cancer cell in-situ (right at the source tumor) with sufficient number of GNPs that will allow enhanced non-invasive detection via photoacoustic imaging in the lymph nodes. Such in-situ labeling can be achieved via sustained release of the GNPs from Radiotherapy (RT) biomaterials (e.g. fiducials, spacers) coated/loaded with the GNP. Methods: The minimum concentration (1000 GNPs/cell for 50nm GNPs) to detect GNPs with photoacoustic imaging method was experimentally measured by Mallidi et al. and fixed at the tumor sub-volume periphery. In this work, the GNPs were assumed to diffuse from a point source, placed in the middle of a 2–3cm tumor, with an initial concentration of 7–30 mg/g. The time required to label the cells with GNPs was calculated by solving the three dimensional diffusion-reaction equation analytically. The diffusion coefficient of 10nm GNPs was experimentally determined previously. Stokes-Einstein equation was used to calculate the diffusion coefficients for other sizes (2–50nm) of GNPs. The cellular uptake rate constants for several sizes of GNPs were experimentally measured by Jin et al. Results: The time required to label the cells was found 0.635–15.91 days for 2–50nm GNPs with an initial concentration of 7 mg/g GNPs in a 2 cm tumor; 1.379–34.633 days for 2–50nm GNPs with an initial concentration of 30 mg/g GNPs in a 3cm tumor. Conclusion: Our results highlight new potential for labeling CTCs with GNPs released from smart RT biomaterials (i.e. fiducials or spacers loaded with the GNP) towards enhanced non-invasive imaging/detection via photoacoustic imaging.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations

Purpose: Development of strategies to monitor range uncertainties is necessary to improve treatment planning in Charged Particle Therapy (CPT) and fully exploit the advantages of ion beams. Our group developed (within the framework of the INSIDE project funded by the Italian research ministry) and is currently building a compact detector Dose Profiler (DP) able to backtrack charged secondary particles produced in the patient during the irradiation. Furthermore we are studying monitoring strategy exploiting charged secondary emission profiles to control the range of the ion beam. Methods: This contribution reports on the DP detector design and construction status. The detector consists of a charged secondary tracker composed of scintillating fiber layers and a LYSO calorimeter for particles energy measurement.The detector layout has been optimized using the FLUKA Monte Carlo (MC) simulation software. The simulation of a 220 MeV Carbon beam impinging on a PMMA target has been performed to study the detector response, exploiting previous secondary radiation measurements performed by our group. The emission profile of charged secondary particles was reconstructed backtracking the particles to their generation point to benchmark the DP performances. Results: The DP construction status, including the technological details will be presented. The feasibility of range monitoring with DP will be demonstrated by means of MC studies. The correlation of the charged secondary particles emission shape with the position of the Bragg peak (BP) will be shown, as well as the spatial resolution achievable on the BP position estimation (less than 3 mm) in the clinical like conditions. Conclusion: The simulation studies supported the feasibility of an accurate range monitoring technique exploiting the use of charged secondary fragments emitted during the particle therapy treatment. The DP experimental tests are foreseen in 2016, at CNAO particle therapy center in Pavia.

60 APPLIED LIFE SCIENCES↗

Tracking Pulses of the Madden-Julian Oscillation

An international field campaign aiming at atmospheric and oceanic processes associated with the Madden-Julian Oscillation (MJO) was conducted in and around the tropical Indian Ocean (IO) during October 2011 - March 2012. The objective of the field campaign was to collect observations urgently needed to expedite the progress of understanding the key processes of the MJO, focusing on its initiation but also including propagation and maturation, and ultimately to improve skills of numerical simulation and prediction of the MJO. Primary targets of the field campaign include interaction of atmospheric deep convection with its environmental moisture, evolution of cloud populations, and air-sea interaction. Several MJO events were captured by ground-based, airborne, and oceanic instruments with advanced observing technology. Numerical simulations and real-time forecasts were integrated components of the field campaign in its design and operation. Observations collected during the campaign provide unprecedented opportunities to reveal detailed processes of the MJO and to assist evaluation, improvement and development of weather and climate models. The data policy of the campaign encourages the broad research community to use the field observations to advance the MJO study.

madden-julian↗

Rugged nanoparticle tracers for mass tracking in explosive events

Tracing the flow of solid matter during an explosion requires a rugged tag that can be measured by a unique identifiable signature. Silica-covered semiconductor quantum dots (QDs) provide a unique and tunable photoluminescent signature that emits from within a sacrificial outer layer. Five types of silica-covered zinc sulfide QDs were synthesized and covalently bound to commercial luminescent powders. The combination of five dots and five powders enables a matrix of 25 unique tags. The tracers are shown to be tolerant of environments associated with chemical explosives and provides a unique tag to evaluate debris fields.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗