Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Element-specific visualization of dynamic magnetic coupling in a Co/Py bilayer microstructure

We present the element-specific and time resolved visualization of uniform ferromagnetic resonance excitations of a Permalloy (Py) disk–Cobalt (Co) stripe bilayer microstructure. The transverse high frequency component of the resonantly excited magnetization is sampled in the ps regime by a combination of ferromagnetic resonance (FMR) and scanning transmission X-ray microscopy (STXM-FMR) recording snapshots of the local magnetization precession of Py and Co with nanometer spatial resolution. The approach allows us to individually image the resonant dynamic response of each element, and we find that angular momentum is transferred from the Py disk to the Co stripe and vice versa at their respective resonances. The integral (cavity) FMR spectrum of our sample shows an unexpected additional third resonance. This resonance is observed in the STXM-FMR experiments as well. Our microscopic findings suggest that it is governed by magnetic exchange between Py and Co, showing for the Co stripe a difference in relative phase of the magnetization due to stray field influence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

N-dependent dynamics of root growth and nitrate and ammonium uptake are altered by the bacterium Herbaspirillum seropedicae in the cereal model Brachypodium distachyon

Nitrogen (N) fixation in cereals by root-associated bacteria is a promising solution for reducing use of chemical N fertilizers in agriculture. However, plant and bacterial responses are unpredictable across environments. We hypothesized that cereal responses to N-fixing bacteria are dynamic, depending on N supply and time. To quantify the dynamics, a gnotobiotic, fabricated ecosystem (EcoFAB) was adapted to analyse N mass balance, to image shoot and root growth, and to measure gene expression of Brachypodium distachyon inoculated with the N-fixing bacterium Herbaspirillum seropedicae. Phenotyping throughput of EcoFAB-N was 25–30 plants h -1 with open software and imaging systems. Herbaspirillum seropedicae inoculation of B. distachyon shifted root and shoot growth, nitrate versus ammonium uptake, and gene expression with time; directions and magnitude depended on N availability. Primary roots were longer and root hairs shorter regardless of N, with stronger changes at low N. At higher N, H. seropedicae provided 11% of the total plant N that came from sources other than the seed or the nutrient solution. The time-resolved phenotypic and molecular data point to distinct modes of action: at 5 mM NH 4 NO 3 the benefit appears through N fixation, while at 0.5 mM NH 4 NO 3 the mechanism appears to be plant physiological, with H. seropedicae promoting uptake of N from the root medium.Future work could fine-tune plant and root-associated microorganisms to growth and nutrient dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

TITUS: Visualization of Neutrino Events in Liquid Argon Time Projection Chambers

The amount and complexity of data recorded by high energy physics experiments are rapidly growing, and with these grow the difficulties in visualizing such data. To study the physics of neutrinos, a type of elementary particle, scientists use liquid argon time projection chamber (LArTPC) detectors, among other technologies. LArTPCs have a very high spatial resolution and resolve many of the elementary particles that come out of a neutrino interacting within the argon in the detector. Visualizing these neutrino interactions is of fundamental importance to understanding the properties of neutrinos, but also monitoring and checking on the detector conditions and operations. From these ideas, we have developed TITUS, an event display that shows images recorded by these neutrino detectors. TITUS is a piece of software that reads data coming from LArTPC detectors (as well as the corresponding simulation) and allows users to explore such data in multiple ways. TITUS is flexible to enable fast prototyping and customization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The molecular spiral arms of NGC 6946

From CO-12(J=1 to 0) observations at 45 seconds resolution Tacconi and Young (1989) have found evidence for enhancements in both the CO emissivity and the massive star formation efficiency (MSFE) on optical spiral arms of the bright spiral galaxy NGC 6946. In the optically luminous and well-defined spiral arm in the NE quadrant, there are enhancements in both the H2 surface density and MSFE relative to the interarm regions. In contrast, a poorly defined arm in the SW shows no arm-interarm contrast in the MSFE. To further investigate the molecular gas content of these two spiral arms, researchers have made CO-12 J=2 to 1 and 3 to 2 observations with the James Clerk Maxwell Telescope. In the J=2 to 1 line, they made observations of the NE and SW spiral arm and interarm regions in 4 x 9 10 seconds spaced grids (36 points per grid). Because of decreased sensitivity in the J=3 to 2 line, they were limited to mapping the two arm regions in 2 x 3 10 seconds spaced grids (6 points per grid). The centers of each of the grids lie 2.4 minutes to the NE and 2.3 minutes to the SW of the nucleus of NGC 6946. With the CO J=2 to 1 data researchers are able to fully resolve the two observed spiral arms in NGC 6946. In both cases the CO emission is largely confined to the optical spiral arm regions with the peak observed T asterisk sub A being up to 4 times higher on the spiral arms than in the interarm regions. Researchers are currently estimating massive star formation efficiencies on and off the spiral arms through direct comparison of the CO maps with an H alpha image. They are also comparing the CO J=2 to 1 data with an HI map made at similar resolution. Thus, they will be able to determine structure in all components of the IS on scales of less than 20 inches.

Tacconi, L. J.↗

The Crab nebula and pulsar in the MeV energy range

The imaging Compton Telescope (COMPTEL) is sensitive in the energy range of 0.75 to 30 MeV. COMPTEL observed the Crab several times during the Compton Gamma Ray Observatory (CGRO) sky survey and CGRO Phase II. Both the Crab pulsar and nebula are detected over the entire COMPTEL energy range. The phase-averaged energy spectra of the Crab Pulsar and Nebula are presented. The combined observations provide sufficient statistics for a phase-resolved analysis of the Crab pulsar spectrum.

Much, R.↗

Integration, Testing and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator-class instrument for the Kitt Peak National Observatory 2.1 m and Mayall 3.8 m telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = lambda/delta lambda = 300 - 3000). On the 3.8 m telescope, IRMOS produces simultaneous spectra of approximately 100 objects in its approximately 3 x 2 arcmin field of view using a commercial micro electro-mechanical systems (MEMS) digital micro-mirror device (DMD) from Texas Instruments. The multi-mirror array DMD operates as a real-time programmable slit mask. The all-reflective optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto a large-format detector. The instrument operates at approximately 80 K, cooled by a single electro-mechanical cryocooler. The bench and all components are made from aluminum 6061-T651. There are three cryogenic mechanisms. We describe laboratory integration and test of IRMOS before shipment to Kitt Peak. We give an overview of the optical alignment technique and integration of optical, mechanical, electrical and cryogenic subsystems. We compare optical test results to model predictions of point spread function size and morphology, contrast, and stray light. We discuss some lessons learned and conclude with a prediction for performance on the telescope.

Ohl, Raymond G.↗

DETECTION OF HF TOWARD PKS 1830–211, SEARCH FOR INTERSTELLAR H{sub 2}F{sup +}, AND LABORATORY STUDY OF H{sub 2}F{sup +} AND H{sub 2}Cl{sup +} DISSOCIATIVE RECOMBINATION

We report extragalactic observations of two fluorine-bearing species, hydrogen fluoride (HF) and fluoronium (H{sub 2}F{sup +}), in the z = 0.89 absorber in front of the lensed blazar PKS 1830−211 with the Atacama Large Millimeter/submillimeter Array. HF was detected toward both southwest and northeast images of the blazar, with column densities >3.4 × 10{sup 14} cm{sup −2} and 0.18 × 10{sup 14} cm{sup −2}, respectively. H{sub 2}F{sup +} was not detected, down to an upper limit (3σ) of 8.8 × 10{sup 11} cm{sup −2} and an abundance ratio of [H{sub 2}F{sup +}]/[HF] ⩽ 1/386. We also searched for H{sub 2}F{sup +} toward the Galactic sources NGC 6334 I and W51C, and toward Galactic center clouds with the Herschel HIFI spectrometer.{sup 6} The upper limit on the column density was derived to be 2.5 × 10{sup 11} cm{sup −2} in NGC 6334 I, which is 1/68 of that for H{sub 2}Cl{sup +}. In constrast, the ortho transition of H{sub 2}Cl{sup +} is detected toward PKS 1830–211. To understand the small abundance of interstellar H{sub 2}F{sup +}, we carried out laboratory experiments to determine the rate constants for the ion–electron recombination reaction by infrared time-resolved spectroscopy. The constants determined are k {sub e}(209 K) = (1.1±0.3)×10{sup −7} cm{sup 3} s{sup −1} and (0.46±0.05)×10{sup −7} cm{sup 3} s{sup −1} for H{sub 2}F{sup +} and H{sub 2}Cl{sup +}, respectively. The difference in the dissociative recombination rates between H{sub 2}F{sup +} and H{sub 2}Cl{sup +} by a factor ∼2 and the cosmic abundance ratio [F]/[Cl] ≈ 1/6 are not enough to explain the much smaller abundance of H{sub 2}F{sup +}. The difference in the formation mechanism of H{sub 2}F{sup +} and H{sub 2}Cl{sup +} in interstellar space would be a major factor in the small abundance of H{sub 2}F{sup +}.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking Smoke from a Prescribed Fire and its Impacts on Local Air Quality using Temporally Resolved GOES-16 ABI Aerosol Optical Depth (AOD)

Aerosol optical depth (AOD) retrieved from the GOES-16 Advanced Baseline Imager (ABI) was used to track a smoke plume from a prescribed fire in northeastern Virginia on 8 March 2020. Weather and atmospheric conditions created a favorable environment to transport the plume through the Washington, D.C., and Baltimore, Maryland, metro areas in the afternoon and concentrate smoke near the surface, degrading air quality for several hours. ABI AOD with 5-min temporal resolution and 2-km spatial resolution definitively identified the timing and geographic extent of the plume during daylight hours. Comparison to AERONET AOD indicates that ABI AOD captured the relative change in AOD due to passage of the smoke, with a mean absolute error of 0.047. Ground-based measurements of fine particulate matter (PM2.5) confirm deteriorations in air quality coincident with the progression of the smoke. Ceilometer aerosol backscatter profiles verify plume transport timing and indicate that smoke aerosols were well mixed in a shallow boundary layer. This event illustrates the advantages of using multiple datasets to analyze the impacts of aerosols on ambient air quality. Given the quickly evolving nature of the event over several hours, ABI AOD provided information for the public and decision-makers that was not available from any other source, including polar-orbiting satellite sensors. This study suggests that PM2.5 concentrations estimated from ABI AOD can be used to fill in the gaps in nationwide regulatory PM2.5 monitor networks and may be a valuable addition to EPA’s PM2.5 NowCast of current air quality conditions.

satellite observations↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Diffractive Imaging of Conical Intersections Amplified by Resonant Infrared Fields

The fate of virtually all photochemical reactions is determined by conical intersections. These are energetically degenerate regions of molecular potential energy surfaces that strongly couple electronic states, thereby enabling fast relaxation channels. Their direct spectroscopic detection relies on weak features that are often buried beneath stronger, less interesting contributions. For azobenzene photoisomerization, a textbook photochemical reaction, we demonstrate how a resonant infrared field can be employed during the conical intersection passage to significantly enhance its coherence signatures in time-resolved Xray diffraction while leaving the product yield intact. Furthermore, this transition-state amplification holds promise to bring signals of conical intersections above the detection threshold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stochastic 3D reconstruction of cracked polycrystalline NMC particles using 2D SEM data

Li-ion battery performance is strongly influenced by the 3D microstructure of its cathode particles. Cracks within these particles develop during calendaring and cycling, reducing connectivity but increasing reactive surface, making their impact on battery performance complex. Understanding these contradictory effects requires a quantitative link between particle morphology and battery performance. However, informative 3D imaging techniques are time-consuming, costly and rarely available, such that analyses often have to rely on 2D image data. This paper presents a novel stereological approach for generating virtual 3D cathode particles exhibiting crack networks that are statistically equivalent to those observed in 2D sections of experimentally measured particles. Consequently, 2D image data suffices for deriving a full 3D characterization of cracked cathodes particles. Such virtually generated 3D particles could serve as geometry input for spatially resolved electro-chemo-mechanical simulations to enhance our understanding of structure-property relationships of cathodes in Li-ion batteries.

36 MATERIALS SCIENCE↗

Rovibronic structure in slow photoelectron velocity-map imaging spectroscopy of CH{sub 2}CN{sup −} and CD{sub 2}CN{sup −}

We report high-resolution anion photoelectron spectra of the cryogenically cooled cyanomethide anion, CH{sub 2}CN{sup −}, and its isotopologue, CD{sub 2}CN{sup −}, using slow photoelectron velocity-map imaging (SEVI) spectroscopy. Electron affinities of 12 468(2) cm{sup −1} for CH{sub 2}CN and 12 402(2) cm{sup −1} for CD{sub 2}CN are obtained, demonstrating greater precision than previous experiments. New vibrational structure is resolved for both neutral species, especially activity of the ν{sub 5} hydrogen umbrella modes. The ν{sub 6} out-of-plane bending mode fundamental frequency is measured for the first time in both systems and found to be 420(10) cm{sup −1} for CH{sub 2}CN and 389(8) cm{sup −1} for CD{sub 2}CN. Some rotational structure is resolved, allowing for accurate extraction of vibrational frequencies. Temperature-dependent SEVI spectra show marked effects ascribed to controlled population of low-lying anion vibrational levels. We directly measure the inversion splitting between the first two vibrational levels of the anion ν{sub 5} umbrella mode in both species, finding a splitting of 130(20) cm{sup −1} for CH{sub 2}CN{sup −} and 81(20) cm{sup −1} for CD{sub 2}CN{sup −}. Franck-Condon forbidden activity is observed and attributed to mode-specific vibrational autodetachment from the CH{sub 2}CN{sup −} and CD{sub 2}CN{sup −} dipole bound excited states. We also refine the binding energy of the anion dipole bound states to 39 and 42 cm{sup −1}, respectively, for CH{sub 2}CN{sup −} and CD{sub 2}CN{sup −}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning microwave imaging of optically patterned Ge 2 Sb 2 Te 5

The measurement of inhomogeneous conductivity in optically crystallized, amorphous Ge 2 Sb 2 Te 5 (GST) films is demonstrated via scanning microwave impedance microscopy (MIM). Qualitative consistency with expectations is demonstrated in spots crystallized by focused coherent light at various intensities, exposure times, and film thicknesses. The characterization of process imperfections is demonstrated when a mask is used to optically pattern the nanoscale features of crystalline GST in the amorphous film. In conclusion, these measurements show the ability of MIM to resolve partial crystallization, patterning faults, and other details in optically patterned GST.

36 MATERIALS SCIENCE↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

TIME-DEPENDENT SUPPRESSION OF OSCILLATORY POWER IN EVOLVING SOLAR MAGNETIC FIELDS

Oscillation amplitudes are generally smaller within magnetically active regions like sunspots and plage when compared to their surroundings. Such magnetic features, when viewed in spatially resolved power maps, appear as regions of suppressed power due to reductions in the oscillation amplitudes. Employing high spatial- and temporal-resolution observations from the Dunn Solar Telescope (DST) in New Mexico, we study the power suppression in a region of evolving magnetic fields adjacent to a pore. By utilizing wavelet analysis, we study for the first time how the oscillatory properties in this region change as the magnetic field evolves with time. Image sequences taken in the blue continuum, G-band, Ca ii K, and H α filters were used in this study. It is observed that the suppression found in the chromosphere occupies a relatively larger area, confirming previous findings. Also, the suppression is extended to structures directly connected to the magnetic region, and is found to get enhanced as the magnetic field strength increased with time. The dependence of the suppression on the magnetic field strength is greater at longer periods and higher formation heights. Furthermore, the dominant periodicity in the chromosphere was found to be anti-correlated with increases in the magnetic field strength.

79 ASTRONOMY AND ASTROPHYSICS↗

ACMEV-SP2 (Single Particle Soot Photometer)

The SP2 provides information on the amounts of rBC (refractory black carbon) and of other, non-refractory substances associated with individual rBC containing particles by simultaneously measuring the scattering and incandescence signals of such particles that are directed through the cavity of a 1064 nm Nd:YAG laser. (refractory Black Carbon) rBC mixing ratio (ng/Kg) and number size distribution time series collected during the DOE-ARM sponsored ACME-V field campaign held from June 1 to September 15, 2015 rBC mixing ratio is reported at STP conditions Time resolution: 10 sec Uncertainty: ~ 30% SP2 Unit: 25 Location: Deadhorse, AK Location: N 70-degree 11' 41'' - W 148-degress. 27' 55'' SP2_dateTime: UTC rBC concentration is in units of ng/Kg - dry air. Mass Equivalent Diameters [MED] used for size distribution (SP2_min; SP2_geo; and SP2_max) are in units of micrometers dN/dlogDp counts for a given size bin (SP2_geo) listed as 'SP2_cnts_0 - SP2_cnts_199' and are in units of #/cc. Column naming convention: 'SP2_cnts_X' are the number of particles in bin number _X. , where _X is the row number within the 'SP2_geo' size bin column that contains the mass equivalent diameter (e.g., SP2_cnts_0 = 0.01 microns; SP2_cnts_10 = 0.060 microns, etc.). The dN/dlogDp data is time-resolved where a given row is associated with the timestamp for that row. Note that the rBC column length is one field shorter than the SP2_datetime column. Last time field is not relevant to the rBC time series (see comment below on length of SP2_datetime column) Lengths for SP2_max; SP2_min; SP2_geo are one field longer then the number of SP2_cnts_XX columns . This is to provide bounds for image plots (if desired). Length for SP2_datetime is one field longer than that length of the SP2_cnts_XX columns This is to provide bounds for image plots (if desired) SP2 Calibration: Fullerene soot with corrrection applied for particle density as a function of particle size. No correction for OC content in Fullerene (recent study on SP2 sensitivity to differing black carbon types reports that non-refractory material content for fullerene soot is about 20%).

54 ENVIRONMENTAL SCIENCES↗

black carbon mass loading, size distribution for CACTI - ground site

The Single-Particle Soot Photometer (SP2, Droplet Mea- surement Technologies) is an instrument that measures, in situ, the time-dependent scattering and incandescence signals produced by individual BC-containing particles as they travel through a continuous-wave laser beam. Any particle traversing the laser beam will scatter light, and the BC component of a BC-containing particle will absorb some of the laser energy until its temperature is raised to the point at which it incandesces (hereafter we adopt the standard terminology of the SP2 community and denote any substance determined by the SP2 to be BC as refractory black carbon (rBC)). The scattering signal provides information on particle size, and the incandescence signal is used for counting rBC-containing particles and yields the mass of the rBC component within each particle (obtained via calibration). Hence, the SP2 can determine size-resolved number and mass concentrations of rBC-containing particles and thus provides information on the rBC particle population-based mixing states within ambient aerosols rBC concentration is reported at STP conditions Time resolution: 1-min Uncertainty: ~ 30% SP2 Unit: 25 Location: Ascension Island, British Territory Location: 7° 56' S, 14° 25' W" SP2_dateTime: UTC rBC concentration is in units of ng/m^3 - dry air. Mass Equivalent Diameters [MED] used for size distribution (SP2_min; SP2_geo; and SP2_max) are in units of micrometers dN/dlogDp counts for a given size bin (SP2_geo) listed as 'SP2_cnts_0…SP2_cnts_199'. Column naming convention: 'SP2_cnts_X' are the number of particles in bin number _X. , where _X is the row number within the 'SP2_geo' size bin column that contains the mass equivalent diameter (e.g., SP2_cnts_0 = 0.01 microns; SP2_cnts_10 = 0.060 microns, etc…). The dN/dlogDp data is time-resolved where a given row is associated with the timestamp for that row. Note that the rBC column length is one field shorter than the SP2_datetime column. Last time field is not relevant to the rBC time series (see comment below on length of SP2_datetime column) Lengths for SP2_max; SP2_min; SP2_geo are one field longer then the number of SP2_cnts_XX columns . This is to provide bounds for image plots (if desired). Length for SP2_datetime is one field longer than that length of the SP2_cnts_XX columns This is to provide bounds for image plots (if desired) SP2 Calibration: Fullerene soot with corrrection applied for particle density as a function of particle size. No correction for OC content in Fullerene (recent study on SP2 sensitivity to differing black carbon types reports that non-refractory material content for fullerene soot is about 20%). Comments and/or requests are to be directed to Art Sedlacek (sedlacek@bnl.gov)

54 ENVIRONMENTAL SCIENCES↗

Image enhancement filters significantly improve reading performance for low vision observers

As people age, so do their photoreceptors; many photoreceptors in central vision stop functioning when a person reaches their late sixties or early seventies. Low vision observers with losses in central vision, those with age-related maculopathies, were studied. Low vision observers no longer see high spatial frequencies, being unable to resolve fine edge detail. We developed image enhancement filters to compensate for the low vision observer's losses in contrast sensitivity to intermediate and high spatial frequencies. The filters work by boosting the amplitude of the less visible intermediate spatial frequencies. The lower spatial frequencies. These image enhancement filters not only reduce the magnification needed for reading by up to 70 percent, but they also increase the observer's reading speed by 2-4 times. A summary of this research is presented.

Lawton, T. B.↗