Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Surface temperature dependence of tropical cyclone-permitting simulations in a spherical model with uniform thermal forcing

Tropical cyclone (TC)-permitting general circulation model simulations are performed with spherical geometry and uniform thermal forcing, including uniform sea surface temperature (SST) and insolation. The dependence of the TC number and TC intensity on SST is examined in a series of simulations with varied SST. The results are compared to corresponding simulations with doubly periodic f -plane geometry, rotating radiative convective equilibrium. The turbulent equilibria in simulations with spherical geometry have an inhomogenous distribution of TCs with the density of TCs increasing from low to high latitudes. The preferred region of TC genesis is the subtropics, but genesis shifts poleward and becomes less frequent with increasing SST. In conclusion, both rotating radiative convective equilibrium and spherical geometry simulations have decreasing TC number and increasing TC intensity as SST is increased.

54 ENVIRONMENTAL SCIENCES↗

Online Dynamic Mode Decomposition Based System Identification of Multi-Zone Building HVAC Systems

Many works have recently been conducted to reduce the electricity consumption of smart buildings and allow them to support various grid services. Most of these works require accurate system models for the various appliances in the building including heating, ventilation, and air conditioning (HVAC) units. In this paper, we investigate a recursive data-driven system identification strategy to construct the thermal model for a time-varying building with a multi-zone HVAC unit. The online dynamic mode decomposition (DMD)-based strategy is employed to identify the multi-zone thermal building dynamics, where a simple information update (rank-1) is selected to avoid computational complexity. The DMD-based identification strategy is validated using a real gymnasium building equipped with a 4-zone HVAC unit, and its performance is compared with that of the traditional nuclear-norm subspace identification (N2SID) strategy.

Wu, Tumin [University of Tennessee, Knoxville (UTK↗

Thermal Testing and Model Correlation for Advanced Topographic Laser Altimeter Instrument (ATLAS)

The Advanced Topographic Laser Altimeter System (ATLAS) part of the Ice Cloud and Land Elevation Satellite 2 (ICESat-2) is an upcoming Earth Science mission focusing on the effects of climate change. The flight instrument passed all environmental testing at GSFC (Goddard Space Flight Center) and is now ready to be shipped to the spacecraft vendor for integration and testing. This topic covers the analysis leading up to the test setup for ATLAS thermal testing as well as model correlation to flight predictions. Test setup analysis section will include areas where ATLAS could not meet flight like conditions and what were the limitations. Model correlation section will walk through changes that had to be made to the thermal model in order to match test results. The correlated model will then be integrated with spacecraft model for on-orbit predictions.

Thermal↗

High-heat transfer lithium-ion batteries: A new era in battery thermal management

Despite advances in lithium-ion battery technology, critical challenges remain that must be addressed to accelerate electric vehicle (EV) adoption and global energy transformation. Significantly improved battery thermal management (BTM) is key to overcoming these challenges. BTM approaches focus on increasing heat transfer coefficients via air, liquid, or refrigerant cooling, but less attention is given to reducing the battery's thermal resistance, a major bottleneck for heat transfer. This work introduces a novel approach to reduce battery thermal resistance by integrating in-plane heat transfer with optimized cell geometry, minimized thermal resistances, and reduced interfacial resistances, representing a departure from previous methods. The standard prismatic can cell incorporating this technology is referred to as the high heat transfer (HHT) battery. An equivalent resistance battery thermal model is developed for speed and accuracy, validated against experimental data in the literature, demonstrating strong correlation and ensuring reliable predictions for real-world performance. Thermal performance metrics of the conventional and HHT batteries are compared using a parametric study with air, liquid, and refrigerant boundary conditions across a range of aspect ratios. The HHT battery shows a heat removal rate up to 20 times higher than a conventional battery. These findings suggest that HHT technology could be transformative for EV battery performance, enabling fast charging, mitigating thermal runaway, extending battery life, reducing cold-weather power loss, increasing reliability, lowering costs, and enabling higher energy density, all critical for EV adoption and energy transformation. Future work will focus on prototyping and real-world testing to refine these findings for commercial-scale applications.

25 ENERGY STORAGE↗

Estimation of Delamination Crack Depth Using Passive Thermography

Passive thermography is used to monitor small increases in temperature resulting from delamination damage formation in a composite hat-stiffened panel during quasi-static loading. The heating is composed of two heat generation components. The first component is an instantaneous response due to a strain release during quasi-static loading. The second component is mechanical heating, at the interface of failure, due to fracture damage. This second component produces a transient rise in temperature that is a function of the damage depth and thermal diffusivity. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is used to determine the damage depth. The results are compared to ultrasonic and X-ray CT data. The advantages and limitations of the thermal technique for damage depth detection are discussed.

Zalameda, Joseph N.↗

Conductivity and dissociation in liquid metallic hydrogen and implications for planetary interiors

Liquid metallic hydrogen (LMH) is the most abundant form of condensed matter in our solar planetary structure. The electronic and thermal transport properties of this metallic fluid are of fundamental interest to understanding hydrogen’s mechanism of conduction, atomic or pairing structure, as well as the key input for the magnetic dynamo action and thermal models of gas giants. Here, we report spectrally resolved measurements of the optical reflectance of LMH in the pressure region of 1.4–1.7 Mbar. We analyze the data, as well as previously reported measurements, using the free-electron model. Fitting the energy dependence of the reflectance data yields a dissociation fraction of 65 ± 15%, supporting theoretical models that LMH is an atomic metallic liquid. We determine the optical conductivity of LMH and find metallic hydrogen’s static electrical conductivity to be 11,000–15,000 S/cm, substantially higher than the only earlier reported experimental values. Here, the higher electrical conductivity implies that the Jovian and Saturnian dynamo are likely to operate out to shallower depths than previously assumed, while the inferred thermal conductivity should provide a crucial experimental constraint to heat transport models.

08 HYDROGEN↗

Progress Report on SAM Reduced-Order Model Development for Thermal Stratification and Mixing during Reactor Transients

This report documents the initial progress on the reduced-order flow model developments in SAM for thermal stratification and mixing modeling. Two different modeling approaches are pursued. The first one is based on one-dimensional fluid equations with additional terms accounting for the thermal mixing from both flow circulations and turbulent mixing. The second approach is based on three-dimensional coarse-grid CFD approach, in which the full three-dimensional fluid conservation equations are modeled with closure models to account for the effects of turbulence.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Underwater thermomagnetic generator for remote marine thermal energy harvesting and sensing

Thermomagnetic generators offer a promising approach for sustainable power generation in remote marine environments. Here, this study presents the design, thermal modeling, and experimental validation of a passively driven underwater thermomagnetic generator developed for powering ocean observation and monitoring sensors. The generator was evaluated under varying working fluids, thermal boundary conditions, and extended operation to assess real-world applicability. Two fluids, deionized water and silicone-based Thermal C5, were tested under simulated shallow- and deep-ocean conditions. Deionized water outperformed Thermal C5, especially in colder environments (~5°C), achieving a peak output of 2.7 mW due to larger temperature gradients and enhanced convective-evaporative heat transfer. Long-duration tests revealed a transient evaporation-condensation cycle that temporarily reduced rotor immersion and performance before stabilizing. The generator powered commercial marine sensors for over 6 h without external batteries, demonstrating the viability of compact, passively cooled thermomagnetic systems for autonomous, off-grid marine sensing.

13 HYDRO ENERGY↗

CONSTRAINING THE OPTICAL EMISSION FROM THE DOUBLE PULSAR SYSTEM J0737-3039

We present the first optical observations of the unique system J0737-3039 (composed of two pulsars, hereafter PSR-A and PSR-B). Ultra-deep optical observations, performed with the High Resolution Camera of the Advanced Camera for Surveys on board the Hubble Space Telescope, could not detect any optical emission from the system down to m{sub F435W} = 27.0 and m{sub F606W} = 28.3. The estimated optical flux limits are used to constrain the three-component (two thermal and one non-thermal) model recently proposed to reproduce the XMM-Newton X-ray spectrum. They suggest the presence of a break at low energies in the non-thermal power-law component of PSR-A and are compatible with the expected blackbody emission from the PSR-B surface. The corresponding efficiency of the optical emission from PSR-A's magnetosphere would be comparable to that of other Myr-old pulsars, thus suggesting that this parameter may not dramatically evolve over a timescale of a few Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

Event Patterns Extracted from Transverse Momentum and Rapidity Spectra of Z Bosons and Quarkonium States Produced in pp and Pb-Pb Collisions at LHC

Transverse momentum ( p T ) and rapidity ( y ) spectra of Z bosons and quarkonium states (some charmonium c c ¯ mesons such as J / ψ and ψ ( 2 S ) and some bottomonium b b ¯ mesons such as Υ ( 1 S ) , Υ ( 2 S ) , and Υ ( 3 S ) ) produced in proton-proton (pp) and lead-lead (Pb-Pb) collisions at the large hadron collider (LHC) are uniformly described by a hybrid model of two-component Erlang distribution for p T spectrum and two-component Gaussian distribution for y spectrum. The former distribution results from a multisource thermal model, and the latter one results from the revised Landau hydrodynamic model. The modelling results are in agreement with the experimental data measured in pp collisions at center-of-mass energies s = 2.76 and 7 TeV and in Pb-Pb collisions at center-of-mass energy per nucleon pair s N N = 2.76 TeV. Based on the parameter values extracted from p T and y spectra, the event patterns (particle scatter plots) in two-dimensional p T - y space and in three-dimensional velocity space are obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Predicting and analyzing the thermal flux incident on test articles in a simulated space environment

The increase in importance and sophistication of thermal-vacuum testing has accentuated the problem of defining the environment to which the test article was subjected. An adequate definition of the test environment is essential to the verification of test-article thermal models. The technique used for defining the test environment at the NASA Manned Spacecraft Center Space Environment Simulation Laboratory and its application during a recent major thermal-vacuum testing program is discussed.

Wallin, S. P.↗

Thermal Contact Conductance

The performance of cryogenic instruments is often a function of their operating temperature. Thus, designers of cryogenic instruments often are required to predict the operating temperature of each instrument they design. This requires accurate thermal models of cryogenic components which include the properties of the materials and assembly techniques used. When components are bolted or otherwise pressed together, a knowledge of the thermal performance of such joints are also needed. In some cases, the temperature drop across these joints represents a significant fraction of the total temperature difference between the instrument and its cooler. While extensive databases exist on the thermal properties of bulk materials, similar databases for pressed contacts do not. This has often lead to instrument designs that avoid pressed contacts or to the over-design of such joints at unnecessary expense. Although many people have made measurements of contact conductances at cryogenic temperatures, this data is often very narrow in scope and even more often it has not been published in an easily retrievable fashion, if published at all. This paper presents a summary of the limited pressed contact data available in the literature.

Salerno, Louis J.↗

Thermal Optimization and Assessment of a Long Duration Cryogenic Propellant Depot

A Cryogenic Propellant Depot (CPD) operating in Low Earth Orbit (LEO) could provide many near term benefits to NASA space exploration efforts. These benefits include elongation/extension of spacecraft missions and reduction of launch vehicle up-mass requirements. Some of the challenges include controlling cryogenic propellant evaporation and managing the high costs and long schedules associated with new spacecraft hardware development. This paper describes a conceptual CPD design that is thermally optimized to achieve extremely low propellant boil-off rates. The CPD design is based on existing launch vehicle architecture, and its thermal optimization is achieved using current passive thermal control technology. Results from an integrated thermal model are presented showing that this conceptual CPD design can achieve propellant boil-off rates well under 0.05% per day, even when subjected to the LEO thermal environment.

Honour, Ryan↗

Thermal Optimization of an On-Orbit Long Duration Cryogenic Propellant Depot

A Cryogenic Propellant Depot (CPD) operating in Low Earth Orbit (LEO) could provide many near term benefits to NASA's space exploration efforts. These benefits include elongation/extension of spacecraft missions and requirement reduction of launch vehicle up-mass. Some of the challenges include controlling cryogenic propellant evaporation and managing the high costs and long schedules associated with the new development of spacecraft hardware. This paper describes a conceptual CPD design that is thermally optimized to achieve extremely low propellant boil-off rates. The CPD design is based on existing launch vehicle architecture, and its thermal optimization is achieved using current passive thermal control technology. Results from an integrated thermal model are presented showing that this conceptual CPD design can achieve propellant boil-off rates well under 0.05% per day, even when subjected to the LEO thermal environment.

Honour, Ryan↗

Scientific Ballooning Technologies Workshop STO-2 Thermal Design and Analysis

The heritage thermal model for the full STO-2 (Stratospheric Terahertz Observatory II), vehicle has been updated to model the CSBF (Columbia Scientific Balloon Facility) SIP-14 (Scientific Instrument Package) in detail. Analysis of this model has been performed for the Antarctica FY2017 launch season. Model temperature predictions are compared to previous results from STO-2 review documents.

Long Duration Balloon↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSCs Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

A Thermally-Conductive Martian Core and Implications for Its Dynamo Cessation

Mars experienced a dynamo process that generated a global magnetic field ~4.3 (or earlier) to 3.6 billion years ago (Ga). The cessation of this dynamo strongly affected Mars’ history and is expected to be linked to thermochemical evolution of Mars’ iron-rich liquid core, which is strongly influenced by its thermal conductivity. Here, we directly measured thermal conductivities of solid iron-sulfur alloys to pressures relevant to the Martian core and temperatures to 1023 Kelvin. Our results show that a Martian core with 16 weight % sulfur has a thermal conductivity of ~19 to 32 Watt meter −1 Kelvin −1 from its top to the center, much higher than previously inferred from electrical resistivity measurements. Our modeled thermal conductivity profile throughout the Martian deep-mantle and core indicates a ~4- to 6-fold discontinuity across the core-mantle boundary. The core’s efficient cooling resulting from the depth-dependent, high conductivity diminishes thermal convection and forms thermal stratification, substantially contributing to cessation of Martian dynamo.

Wen-Pin Hsieh↗