Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

FAST - A Unique Experiment and Simplified Approach to Accelerated Integral Fuel Testing

Idaho National Laboratory has a long and internationally recognized history of performing irradiation testing of advanced fast reactor fuels in the Experimental Breeder Reactor II (EBR-II) and the Advanced Test Reactor (ATR). Since EBR-II’s decommissioning in the early 1990’s, irradiation testing has been exclusively performed in ATR. The testing of fast reactor fuels in ATR is challenging given its thermal neutron spectrum and coolant temperatures far below those prototypic of fast reactors. Adept researchers have overcome these obstacles through the use of Cadmium shrouds which attenuate all thermalized neutrons and an experiment design that fosters fuel and cladding temperatures prototypic of fast neutron reactors. Although this design has successfully demonstrated temperatures and temperature gradients that closely mimic those seen in fast reactors, irradiation performance is highly sensitive to fabrication tolerances and the time requirements necessary for high fuel burnup, where irradiation performance data of fast fuel is lacking, are significant. This work summarizes two novel experiment designs and their associated physics analyses for testing fast reactor fuels in ATR; an accelerated irradiation experiment and a fast spectrum experiment. The accelerated irradiation experiment does not utilize a Cadmium shroud, has been shown to triple the burnup rate, yet yields temperatures and radial power profiles prototypic of fast reactor fuels. The fast spectrum experiment utilizes a booster fuel element that that hardens the incident neutron spectrum and also yields temperatures and radial power profiles prototypic of fast reactor fuels. These experiment designs efficiently reduce irradiation time requirements, are more economical, and significantly increase ATR throughput. Fast reactor experiments that capitalize on these designs expedite irradiation performance data for fast reactor fuels and provide information invaluable to fuel performance modeling and simulation validation over a wide range of parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Postirradiation Examination of the ATF-1 Experiments - 2019 Status

A collaborative effort of the Advanced Fuels Campaign together with industry consortia is focused on the development of enhanced accident tolerant fuels for Light Water Reactors (LWRs). The scoping studies, referred to as ATF-1 irradiations, are being performed in the Advanced Test Reactor of Idaho National Laboratory using drop-in style irradiations. The Post-Irradiation Examinations (PIEs) of ATF-1 began in 2017 and continued in 2019. This report describes the results of examinations on ATF-1 irradiations designed to test the performance of advanced iron-based cladding, including compatibility of FeCrAl with UO2, and ATF-1 irradiation of U3Si5. Two rodlets with commercial iron-based cladding and UO2 pellets have been irradiated to low burnup (i.e., < 20 GWd/tHM). The first rodlet had an Alloy33 cladding, while the other had a Kanthal APMT® cladding. The performed PIEs were focused on the determination of fuel microstructure, evaluation of fuel-cladding interaction and irradiation-induced variations of cladding mechanical properties. For both rodlets, no significant changes in the cladding hardness were measured, and the cladding hoop strain remained limited. Gamma tomography revealed no Cs axial migration as expected for LWR fuel, but significant cesium radial migration, which was induced by thermal migration consequent to high irradiation temperatures. Microstructure analyses revealed formation of secondary phases along the pellet rim of samples from both rodlets. No wastage or extensive chemical interaction between the fuel and the internal wall of the cladding was observed, suggesting that the secondary phases accumulated at the pellet rim might be due to formation of Cs-U-O compounds. However, further advanced PIEs are necessary to finally confirm this hypothesis. Optical microscopy analysis of the rodlet designed by Oak Ridge National Laboratory to evaluate the interaction between UO2 and various FeCrAl alloys revealed no extensive interaction in all the samples irradiated in the rodlet. Localized defects, namely circular pitting and cracks of a few tents of microns, were observed on the FeCrAl disc surfaces in some of the diffusion couples. These defects might be surface fabrication defects rather than irradiation-induced localized corrosion, but chemical analyses are needed to determine whether accumulation of corrosive fission products are causing enhanced interaction. Both non-destructive and destructive PIEs were collected on a rodlet containing U3Si5 fuel. The rodlet had extremely low fission gas release, similar to previously analyzed U3Si2 rodlets. Gamma tomography revealed thermo-migration of fission product ruthenium toward the center of the fuel pellet. The fuel microstructure resembles the as-fabricated microstructure, showing extensive microcracking related to the phase transition at 450°C. Two types of secondary phases were observed, which could either be due to segregation and precipitation of fission products or to UN impurities from fabrication. Finally, the current status of PIE on other ATF-1 irradiations will be discussed. These irradiations include UN-U3Si5 rodlets, UN-U3Si2 rodlets and an additional test with U3Si2 fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fabrication of yeast engineered porous 13X adsorbent layers for CO 2 capture

This study investigates a novel environmentally friendly coating technique using yeast fermentation to obtain super porous Zeolite 13X adsorbent layers through freeze-drying technique for CO 2 capture applications. Several mass ratios of sugar to yeast were used to control the porosity and pore sizes in the adsorbent layer. A unique peeling process was integrated to obtain foamy, hollow structures to have deeper layer accessibility of adsorbent for adsorption applications. These coated adsorbent layers were experimentally characterized as a function of the mass ratio of sugar to yeast and adsorbent solid fraction. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and Fourier-transform infrared spectroscopy (FT-IR) are used to analyze the coated layers. Here, the void fraction for coated samples is found to vary between 0.48 and 0.56, making the samples applicable for adsorption applications. Adsorption performance experiments are performed to test the coated samples' performance compared to 13X powder. Due to their simplistic fabrication, cost-effectiveness, rapid pore formation, and high adsorption capacity, these porous 13X layers hold potential for large-scale fabrication and CO 2 capture applications.

Adsorbent coating↗

Characterization of twin boundaries in an Fe–17.5Mn–0.56C twinning induced plasticity steel

A twinning-induced plasticity steel of composition Fe–17.5 wt.% Mn–0.56 wt.% C–1.39 wt.% Al–0.24 wt.% Si was analyzed for the purpose of characterizing the relationship between tensile strain and deformation twinning. Tensile samples achieved a maximum of 0.46 true strain at failure, and a maximum ultimate tensile strength of 1599 MPa. Electron backscatter diffraction (EBSD) analysis showed that the grain orientation rotated heavily to < 111 > parallel to the tensile axis above 0.3 true strain. Sigma 3 misorientations, as identified by EBSD orientation measurements, and using the image quality maps were used to quantify the number of twins present in the scanned areas of the samples. The image quality method yielded a distinct positive correlation between the twin area density and deformation, but the orientation measurements were unreliable in quantifying twin density in these structures. Quantitative analysis of the twin fraction is limited from orientation information because of the poor spatial resolution of EBSD in relation to the twin thickness. The EBSD orientation maps created for a thin foil sample showed some improvement in the resolution of the twins, but not enough to be significant. Measurements of the twins in the transmission electron microscopy micrographs yielded an average thickness of 23 nm, which is near the resolution capabilities of EBSD on this material for the instrumentation used. Electron channeling contrast imaging performed on one bulk tensile specimen of 0.34 true strain, using a method of controlled diffraction, yielded several images of twinning, dislocation structures and strain fields. A twin thickness of 66 nm was measured by the same method used for the transmission electron microscopy measurement. It is apparent that the results obtain by electron channeling contrast imaging were better than those by EBSD but did not capture all information on the twin boundaries such as was observed by transmission electron microscopy. - Highlights: • Performed tensile tests to assess mechanical performance of TWIP alloy • Analyzed tensile specimens using EBSD, TEM, and ECCI • EBSD showed that most twinning occurred at or near the < 111 >//TA orientation. • EBSD, TEM and ECCI were used to measure average twin density. • Compared spatial resolution of EBSD, ECCI and TEM for the instrumentation used.

36 MATERIALS SCIENCE↗

Resistive switching: An investigation of the bipolar–unipolar transition in Co-doped ZnO thin films

Highlights: • A purely bipolar behavior on a Co-doped ZnO thin film has been demonstrated. • We have shown what can happen if a unipolar test is performed in a purely bipolar device. • An explanation for how a sample can show a purely bipolar switching behavior was suggested. • An important open issue about resistive switching effect was put in debate. - Abstract: In order to investigate the resistive switching effect we built devices in a planar structure in which two Al contacts were deposited on the top of the film and separated by a small gap using a shadow mask. Therefore, two samples of 10% Co-doped ZnO thin films were sputtered on glass substrate. High resolution X-ray diffraction (HRXRD) revealed a highly c-axis oriented crystalline structure, without secondary phase. The high resolution scanning electron microscopy (HRSEM) showed a flat surface with good coverage and thickness about 300 nm. A Keithley 2425 semiconductor characterization system was used to perform the resistive switching tests in the bipolar and unipolar modes. Considering only the effect of compliance current (CC), the devices showed a purely bipolar behavior since an increase in CC did not induce a transition to unipolar behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and performance of a TDC ASIC for the upgrade of the ATLAS Monitored Drift Tube detector

We present the prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for high-luminosity LHC operation. This ASIC is based on a previously submitted demonstrator ASIC designed for timing performance evaluation, and includes all features necessary for the various operation modes, as well as the migration to the TSMC 130 nm CMOS technology. Here, we present the TDC design with the emphasis on added features and performance optimization. Tests of the timing performance demonstrate that this ASIC meets the design specifications. The TDC has a bin size of about 780 ps, and a timing bin variations within ±40 ps for all 24 channels with leading and trailing edge digitization, while the power consumption has been limited to 250 mW, corresponding to a consumption of about 5.2 mW per edge measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mercury oxidation in flue gas using gold and palladium catalysts on fabric filters

The feasibility of oxidizing elemental mercury in coal combustion flue gas using catalytic material impregnated onto fabric filters was explored. TiO{sub 2}, Au/TiO{sub 2}, and Pd/Al{sub 2}O{sub 3} were studied based on promising results in previous research. Several fabric coating methods were investigated to determine the best way to load a filter. A spray coat method was found to have the highest initial loading and had the lowest losses after simulated pulse-jet cleaning. The oxidation performance of the catalyst-coated filters was tested using a simulated flue gas in a bench-scale reactor under conditions similar to those found in a baghouse. Au/TiO{sub 2} and Pd/Al{sub 2}O{sub 3} were effective, yielding mercury oxidation ranges of 40-60% and 50-80%, respectively. A 19 kW research combustor equipped with a baghouse was used to fire a range of coals and further test the performance of Pd/Al{sub 2}O{sub 3}. Results obtained warrant further development of this technique as a means of mercury pollution control. 19 refs., 2 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Mid-Range Coil Array for Magnetic Resonance Imaging of Small Animals

The vast majority of articles on MRI RF coils over the past two decades have focused on large coils, where sample losses dominate, or on micro-coils, where sample and capacitor losses are negligible. Few have addressed the mid-range coils, seen in the majority of small-animal applications, where all the sources of loss are important, for example, mouse brain and body coils from 125 to 750 MHz. We developed a four-saddle coil array for magnetic resonance imaging of small animals. The saddle coil elements in the array were evenly distributed to cover the rat's head. The coil array was tuned to the resonant frequency of 170 MHz. Due to the close proximity of the coil elements, it was necessary to decouple the coil array using nonmagnetic trimmers and, it was operated in the transceiver mode and quadrature-driven. To test the coil array performance at high field, phantom images were acquired with our saddle coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. Ex vivo brain images of a rat were also acquired, and proved the feasibility of the scaled version of a saddle coil array and, its compatibility with standard pulse sequences when used in a high field magnetic resonance imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Q-band frequency tunable Doppler backscattering (DBS) system for pedestal and scrape-off layer density fluctuation and flow measurements in the DIII-D tokamak

We present the design and laboratory tests for a new Q-band frequency tunable Doppler backscattering (DBS) system suitable for probing poloidal wavenumber kñ = 6–8 cm−1 density fluctuations and their flow velocities in the pedestal and scape-off layer (SOL) of the DIII-D tokamak. This system will provide new measurements in the increasingly important and under-diagnosed far pedestal and SOL plasma regions. These results are important for experimental transport studies and necessary for the validation of transport models, both of which are important to fusion energy research. The use of a single tunable frequency reduces the complexity and potential failure points as compared to a multichannel system. This new system utilizes a 33–50 GHz tunable source and will be integrated into the current V-band DBS in DIII-D using a broadband Q- and V-band multiplexer. A full-scale mockup of the quasi-optical system was used to test and optimize the performance. These tests include beam profile measurements at different distances (and angles) from a paraboloidal focusing and steering mirror. The measurements cover the full frequency range 33–75 GHz of the integrated/combined Q–V band DBS system and target a large radial coverage of the low-field side of the plasma from ρ = 1.1 to ρ = 0.5, where ρ is the normalized flux surface radial coordinate.

Instruments & Instrumentation↗

355-nm, nanosecond laser mirror thin film damage competition

Here, this competition aimed to survey state-of-the-art UV high reflectors. The requirements of the coatings are a minimum reflection of 99.5% at 45 degrees incidence angle for P-polarized light at 355-nm. The choice of coating materials, design, and deposition method were left to the participants. Laser damage testing was performed at a single testing facility using the raster scan method with a 5-ns pulse length laser system operating at 10 Hz in a single longitudinal mode. A double blind test assured sample and submitter anonymity. Finally, in addition to the laser damage resistance results, details of the deposition processes, cleaning method, coating materials and layer count are also shared.

36 MATERIALS SCIENCE↗

SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations and those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.

43 PARTICLE ACCELERATORS↗

Carbon fiber paper cathodes for lithium ion batteries

A novel lithium ion battery cathode structure was produced which has the potential for excellent capacity retention and good thermal management. In these cathodes, the active cathode material (lithium iron phosphate) was carbon bonded to a thermally and electrically conductive carbon fiber paper (CFP) support. Electrochemical testing was performed on Swagelok cells consisting of CFP cathodes and lithium anodes. High specific energy, near-theoretical capacity, and good cycling performance were demonstrated for 0.11 mm and 0.37 mm thick CFP cathodes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Commercialization Effort for 1W Consumer Electronics Power Pack

A commercial ready fuel cell charger has been further developed, demonstrated, and field tested during the three phases of this project. The work performed and demonstrated has shown the commercialization readiness of this future product and underlying technology. The tasks in phase 1 of the project focused on component cost reduction, redesign for manufacturability, performance & reliability testing, and system integration. The end of phase 1 was completed on time and was signified by passing the Go/No-Go checkpoint. As shown in the report all technical metrics have been met or exceeded and the Go/No-Go checkpoint was passed in November of 2009. The tasks in phase 2 focused on tool fabrication and tooled component prove-out in working systems. The end of Phase 2 was the accomplishment of building working systems made almost completely of tooled components. The tasks in phase 3 of the project were preparing for and executing a 75 unit field test of the DMFC charger product developed in Phase 1 and phase 2. This field test demonstrated the functionality of the DMFC in the hands of real users while also providing feedback for potential design improvements. This was the first time a significant number of MTI units were put into the field to test usability and functionality. Feedback from the field test was positive and the units functioned well in the field.

08 HYDROGEN↗

Ion Exchange Testing with SRF Resin FY2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.0, which was prepared and approved in response to the Test Specification 24590 PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590 PTF TEF RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Hanford Tank Waste Treatment and Immobilization Pl↗

Ion Exchange Testing with SRF Resin FY 2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.01, which was prepared and approved in response to the Test Specification 24590-PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590-PTF-TEF-RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Ion exchange↗

The Calibration System of the E989 Experiment at Fermilab

The muon anomaly aµ is one of the most precise quantity known in physics experimentally and theoretically. The high level of accuracy permits to use the measurement of aµ as a test of the Standard Model comparing with the theoretical calculation. After the impressive result obtained at Brookhaven National Laboratory in 2001 with a total accuracy of 0.54 ppm, a new experiment E989 is under construction at Fermilab, motivated by the diff of aexp SM µ − aµ ∼ 3σ. The purpose of the E989 experiment is a fourfold reduction of the error, with a goal of 0.14 ppm, improving both the systematic and statistical uncertainty. With the use of the Fermilab beam complex a statistic of × 21 with respect to BNL will be reached in almost 2 years of data taking improving the statistical uncertainty to 0.1 ppm. Improvement on the systematic error involves the measurement technique of ωa and ωp, the anomalous precession frequency of the muon and the Larmor precession frequency of the proton respectively. The measurement of ωp involves the magnetic field measurement and improvements on this sector related to the uniformity of the field should reduce the systematic uncertainty with respect to BNL from 170 ppb to 70 ppb. A reduction from 180 ppb to 70 ppb is also required for the measurement of ωa; new DAQ, a faster electronics and new detectors and calibration system will be implemented with respect to E821 to reach this goal. In particular the laser calibration system will reduce the systematic error due to gain fl of the photodetectors from 0.12 to 0.02 ppm. The 0.02 ppm limit on systematic requires a system with a stability of 10−4 on short time scale (700 µs) while on longer time scale the stability is at the percent level. The 10−4 stability level required is almost an order of magnitude better than the existing laser calibration system in particle physics, making the calibration system a very challenging item. In addition to the high level of stability a particular environment, due to the presence of a 14 m diameter storage ring, a highly uniform magnetic field and the detector distribution around the storage ring, set specific guidelines and constraints. This thesis will focus on the final design of the Laser Calibration System developed for the E989 experiment. Chapter 1 introduces the subject of the anomalous magnetic moment of the muon; chapter 2 presents previous measurement of g-2, while chapter 3 discusses the Standard Model prediction and possible new physics scenario. Chapter 4 describes the E989 experiment. In this chapter will be described the experimental technique and also will be presented the experimental apparatus focusing on the improvements necessary to reduce the statistical and systematic errors. The main item of the thesis is discussed in the last two chapters: chapter 5 is focused on the Laser Calibration system while chapter 6 describes the Test Beam performed at the Beam Test Facility of Laboratori Nazionali di Frascati from the 29th February to the 7th March as a final test for the full calibrations system. An introduction explain the physics motivation of the system and the diff t devices implemented. In the final chapter the setup used will be described and some of the results obtained will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eddy Current Flow Measurements in the FFTF

The Fast Flux Test Facility (FFTF) is the most recent liquid metal reactor (LMR) to be designed, constructed, and operated by the U.S. Department of Energy (DOE). The 400-MWt sodium-cooled, fast-neutron flux reactor plant was designed for irradiation testing of nuclear reactor fuels and materials for liquid metal fast breeder reactors. Following shut down of the Clinch River Breeder Reactor Plant (CRBRP) project in 1983, FFTF continued to play a key role in providing a test bed for demonstrating performance of advanced fuel designs and demonstrating operation, maintenance, and safety of advanced liquid metal reactors. The FFTF Program provides valuable information for potential follow-on reactor projects in the areas of plant system and component design, component fabrication, fuel design and performance, prototype testing, site construction, and reactor control and operations. This report provides HEDL-TC-1344, “ECFM Flow Measurements in the FFTF Using Phase-Sensitive Detectors”, March 1979.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗