Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUNE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Steam System Balancing and Tuning for Multifamily Residential Buildings: Chicago, Illinois (Fact Sheet)

Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steam System Balancing and Tuning for Multifamily Residential Buildings in Chicagoland—Second Year of Data Collection

Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources. Building on previous research, CNT Energy identified 10 test buildings in Chicago and conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam system balancing. A package of common steam balancing measures was assembled and data were collected on the buildings before and after these retrofits were installed to investigate the process, challenges, and the cost effectiveness of improving steam systems through improved venting and control systems. The test buildings that received venting upgrades and new control systems showed 10.2% savings on their natural gas heating load, with a simple payback of 5.1 years. The methodologies for and findings from this study are presented in detail in this report. This report has been updated from a version published in August 2012 to include natural gas usage information from the 2012 heating season and updated natural gas savings calculations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steam System Balancing and Tuning for Multifamily Residential Buildings in Chicagoland

Older heating systems often suffer from mis-investment--multiple contractors upgrading parts of systems in inadequate or inappropriate ways that reduce system functionality and efficiency--or from a lack of proper maintenance. This technical report addresses these barriers to information, contractor resources, and cost-savings. Building off of previous research, CNT Energy conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam system balancing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steam Balancing and Tuning for Multifamily Residential Buildings in Chicagoland—Second Year of Data Collection

Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards an Aviation Large Language Model by Fine-tuning and Evaluating Transformers

In the aviation domain, there are many applications for machine learning and artificial intelligence tools that utilize natural language. For example, there is a desire to know the commonalities in written safety reports such as voluntary post incidents reports or create more accurate transcripts of air traffic management conversations. Another use-case is the possibility of extracting airspace procedures and constraints currently written in documents such as Letters of Agreement (LOA) which is used as the evaluation case in this paper. These applications can benefit from the use of state-of-the-art Natural Language Processing (NLP) techniques when adapted to the language/phraseology specific to the aviation domain. This paper evaluates the viability of transferring pre-trained large language models to the aviation domain by adapting transformer based models using aviation datasets. This paper utilized two datasets to adapt a ‘Robustly Optimized Bidirectional Encoder Representations from Transformers Approach’ (RoBERTa) model and two down-stream classification tasks to assess its performance. These datasets are all built upon Letters of Agreement which are Federal Aviation Administration (FAA) documents that formalize airspace operations across the national airspace system. The first two datasets are used for the adaptation of RoBERTa to the aviation domain and were of different sizes to assess the number of documents needed to adapt to the aviation domain. They contain many examples of ‘aviation English’ using domain specific terminology and phrasing which serves as a representative basis to perform the unsupervised adaptation. The second dataset is a separate set of LOA documents with two sets of classification labels to be used for evaluation; one at the document level and one at the line level. These down-stream evaluations allowed the measurement of improvement by adapting RoBERTa. The accuracy increased by 4-6% on both tasks and the F1 score on the class of interest increased by 4-8% from the adaptation.

Air Traffic Management↗

Towards an Aviation Large Language Model by Fine-tuning and Evaluating Transformers

In the aviation domain, there are many applications for machine learning and artificial intelligence tools that utilize natural language. For example, there is a desire to know the commonalities in written safety reports such as voluntary post incidents reports or create more accurate transcripts of air traffic management conversations. Another use-case is the possibility of extracting airspace procedures and constraints currently written in documents such as Letters of Agreement (LOA) which is used as the evaluation case in this paper. These applications can benefit from the use of state-of-the-art Natural Language Processing (NLP) techniques when adapted to the language/phraseology specific to the aviation domain. This paper evaluates the viability of transferring pre-trained large language models to the aviation domain by adapting transformer based models using aviation datasets. This paper utilized two datasets to adapt a ‘Robustly Optimized Bidirectional Encoder Representations from Transformers Approach’ (RoBERTa) model and two down-stream classification tasks to assess its performance. These datasets are all built upon Letters of Agreement which are Federal Aviation Administration (FAA) documents that formalize airspace operations across the national airspace system. The first two datasets are used for the adaptation of RoBERTa to the aviation domain and were of different sizes to assess the number of documents needed to adapt to the aviation domain. They contain many examples of ‘aviation English’ using domain specific terminology and phrasing which serves as a representative basis to perform the unsupervised adaptation. The second dataset is a separate set of LOA documents with two sets of classification labels to be used for evaluation; one at the document level and one at the line level. These down-stream evaluations allowed the measurement of improvement by adapting RoBERTa. The accuracy increased by 4-6% on both tasks and the F1 score on the class of interest increased by 4-8% from the adaptation.

Air Traffic Management↗

Tuning the response of terahertz metamaterial at low temperatures

The transmission response of planar thin film metamateriaJs were measured at room and liquid nitrogen temperatures using terahertz time-domain spectroscopy. The behaviour of metamaterials at low temperatures is shown to have low-loss since the nonradiative losses are strongly suppressed due to higher metal film conductivity. We observe a temperature tunable effect and a gradual increase of 40% in the quality factor of the metamaterial. The emerging field of metamaterial (MM) has opened a gateway to unprecedented electromagnetic properties and functionality unattainable from naturally occurring materials. Planar metamaterials are made of thin metal films with a thickness comparable to the skin depth. In spite of several newly found potential applications of these metafilms, practical use is often hindered by strong losses of the metallic elements. It causes a weakening and a damping of the resonance. This makes dissipation the property that dominates the light propagation. Therefore, the compensation of such losses is currently the most important topic to solve prior to advancing MMs to a higher level. Overall metamaterial losses typically have a radiative contribution, which can be tailored by suitable geometrical modifications, and a non-radiative contribution, associated to the intrinsic absorption of the light in the metal and/or dielectric. Thus, one way to improve their performance is to increase the conductivity of the metals. A simple technique to increase the metal conductivity is to cool it to low temperatures.

36 MATERIALS SCIENCE↗

High Activity of Ce1-xNixO2-y for H2 Production through Ethanol Steam Reforming: Tuning Catalytic Performance through Metal↔Oxide Interactions

Ce{sub 0.8}Ni{sub 0.2}O{sub 2-y} is an excellent catalyst for ethanol steam reforming. Metal-oxide interactions perturb the electronic properties of the small particles of metallic nickel present in the catalyst under the reaction conditions and thus suppress any methanation activity. The nickel embedded in ceria induces the formation of O vacancies, which facilitate cleavage of the O-H bonds in ethanol and water.

08 HYDROGEN↗

TUNING OF SIZE AND SHAPE OF AU-PT NANOCATALYST FOR DIRECT METHANOL FUEL CELLS

In this paper, we report the precise control of the size, shape and surface morphology of Au-Pt nanocatalysts (cubes, blocks, octahedrons and dogbones) synthesized via a seed-mediated approach. Gold 'seeds' of different aspect ratios (1 to 4.2), grown by a silver-assisted approach, were used as templates for high-yield production of novel Au-Pt nanocatalysts at a low temperature (40 C). Characterization by electron microscopy (SEM, TEM, HRTEM), energy dispersive X-ray analysis (EDX), UV-Vis spectroscopy, zeta-potential (surface charge), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and inductively coupled plasma mass spectrometry (ICP-MS) were used to better understand their physico-chemical properties, preferred reactivities and underlying nanoparticle growth mechanism. A rotating disk electrode was used to evaluate the Au-Pt nanocatalysts electrochemical performance in the oxygen reduction reaction (ORR) and the methanol oxidation reaction (MOR) of direct methanol fuel cells. The results indicate the Au-Pt dogbones are partially and in some cases completely unaffected by methanol poisoning during the evaluation of the ORR. The ORR performance of the octahedron particles in the absence of MeOH is superior to that of the Au-Pt dogbones and Pt-black, however its performance is affected by the presence of MeOH.

10 SYNTHETIC FUELS↗

High Activity of Ce1-xNixO2-y for H2 Production through Ethanol Steam Reforming: Tuning Catalytic Performance through Metal-Oxide Interactions

The importance of the oxide: Ce{sub 0.8}Ni{sub 0.2}O{sub 2-y} is an excellent catalyst for ethanol steam reforming. Metal-oxide interactions perturb the electronic properties of the small particles of metallic nickel present in the catalyst under the reaction conditions and thus suppress any methanation activity. The nickel embedded in ceria induces the formation of O vacancies, which facilitate cleavage of the OH bonds in ethanol and water.

08 HYDROGEN↗

Fluid Tuned Coupler

Explore the source record for details and available documents.

43 PARTICLE ACCELERATORS↗

Fluid Tuned Coupler

Explore the source record for details and available documents.

43 PARTICLE ACCELERATORS↗

Tuning HDF5 for Lustre File Systems

HDF5 is a cross-platform parallel I/O library that is used by a wide variety of HPC applications for the flexibility of its hierarchical object-database representation of scientific data. We describe our recent work to optimize the performance of the HDF5 and MPI-IO libraries for the Lustre parallel file system. We selected three different HPC applications to represent the diverse range of I/O requirements, and measured their performance on three different systems to demonstrate the robustness of our optimizations across different file system configurations and to validate our optimization strategy. We demonstrate that the combined optimizations improve HDF5 parallel I/O performance by up to 33 times in some cases running close to the achievable peak performance of the underlying file system and demonstrate scalable performance up to 40,960-way concurrency.

97 MATHEMATICS AND COMPUTING↗

Technology Solutions Case Study: Steam System Balancing and Tuning for Multifamily Residential Buildings, Chicago, Illinois

Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources.

Building America↗

Tune-Up Your Fan Systems for Improved Performance

Fans are used extensively in commercial buildings and represent approximately 6% of total energy consumed by commercial buildings. The U.S. Department of Energy (DOE) estimates that fans in commercial buildings consume 158 billion kWh of electricity annually. Maintaining fan systems in proper condition provides energy savings and ensures a comfortable and healthy environment. While many fan systems have significant energy savings opportunities available through improvements in fan selection, system design, and operational practices, it is not always apparent when a fan system needs maintenance or what opportunities are available for improvements. This resource is designed for facility managers and maintenance staff to provide easy-to-implement actionable guidance on fan efficiency measures for existing ducted air systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗