Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Time Resolution Characterization of 4H-SiC LGADs with a 90 Sr Source

This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a 90Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61 ps was achieved, comparable to that of standard Si LGADs. The present limitation in the time resolution of 4H-SiC LGADs appears to stem from limited charge generation. Nevertheless, their higher voltage tolerance and faster carrier drift suggest that, with increased charge collection, their timing performance could approach or even surpass that of Si LGADs. Furthermore, these results demonstrate the strong potential of 4H-SiC LGADs as a robust platform for precision timing in future 4D tracking detectors, while also highlighting that signal charge is the dominant factor currently limiting their performance, indicating that further optimization of gain and drift structures will be essential for future development.

43 PARTICLE ACCELERATORS↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a Hybrid Electric Vehicle Eco-Cooperative Adaptive Cruise Control System at Signalized Intersections.

This study develops an eco-driving strategy for hybrid electric vehicles (HEVs) in the vicinity of signalized intersections, entitled HEV Eco-Cooperative Adaptive Cruise Control at Intersections (Eco-CACC-I). The proposed system computes real-time, energy-optimized vehicle trajectories using HEV vehicle dynamics and energy consumption models. In the proposed system, a simple HEV energy model is used to compute the instantaneous fuel consumption. This HEV energy model is selected since it is general, transferable, and can be easily used to compute instantaneous energy consumption levels for HEVs without the additional input of vehicle engine data or complicated power control strategies. In addition, a vehicle dynamics model is used to capture the relationship between speed, acceleration level, and tractive/resistance forces on vehicles. The energy-optimum problem is formulated as an optimization problem with constraints, which is solved using a moving-horizon dynamic programming approach. The proposed HEV Eco-CACC-I system was tested to evaluate its performance for various speed limits, roadway grades, and signal timings. Lastly, the proposed HEV controller was implemented in a microscopic traffic simulation software to test its network-wide performance. The test results from an arterial corridor with three signalized intersections demonstrate that the proposed system can effectively reduce stop-and-go traffic in the vicinity of signalized intersections producing savings of 7.4% in energy consumption, 5.8% in traffic delay and 23% vehicle stops, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studying the characteristics of scintillation counters in a beam of relativistic particles

In this work, the results of the measurements of characteristics of 40-cm and 2-m scintillation counters irradiated by a particle beam with a momentum of 7 GeV/c from the accelerator of the Institute for High Energy Physics are presented. The scintillators used in counters are BC-404 and BC-408 scintillators. The counters are viewed from both ends by R1828-01 photomultiplier tubes. The PMT signal spectra are well described by a convolution of the Landau and Gaussian distributions. Their width is determined mainly by fluctuations of ionization energy losses. The time distributions of the signals obey the Gaussian law. For the 40-cm counter, the time resolution is σ(T) = 88 ps; for the 2-m counter, it varies from 120–160 ps in its center to ~100 ps near the end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient method for estimating the time evolution of the proto-neutron star mass and radius from a supernova neutrino signal

In this paper, we present a novel method to estimate the time evolution of the proto-neutron star (PNS) structure from the neutrino signal in a core-collapse supernova (CCSN). Employing recent results from multidimensional CCSN simulations, we delve into a relation between the total emitted neutrino energy (TONE) and PNS mass/radius, and we find that they are strongly correlated with each other. We fit the relation by simple polynomial functions connecting the TONE to the mass and radius of the PNS as a function of time. By combining another fitting function representing the correlation between the TONE and the cumulative number of events at each neutrino observatory, the PNS mass and radius can be retrieved from purely observed neutrino data. We demonstrate retrievals of PNS mass and radius from mock data of the neutrino signal, and we assess the capability of our proposed method. While underlining the limitations of the method, we also discuss the importance of the joint analysis with the gravitational wave signal. This would reduce uncertainties of parameter estimations in our method, and may narrow down the possible neutrino oscillation model. The proposed method is a very easy and inexpensive computation, which will be useful in real data analysis of the CCSN neutrino signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-point statistics of cosmological stochastic gravitational waves

We consider the three-point function (i.e. the bispectrum or non-Gaussianity) for stochastic backgrounds of gravitational waves. We estimate the amplitude of this signal for the primordial inflationary background, gravitational waves generated during preheating, and for gravitational waves produced by self-ordering scalar fields following a global phase transition. To assess detectability, we describe how to extract the three-point signal from an idealized interferometric experiment and compute the signal to noise ratio as a function of integration time. The three-point signal for the stochastic gravitational wave background generated by inflation is unsurprisingly tiny. For gravitational radiation generated by purely causal, classical mechanisms we find that, no matter how nonlinear the process is, the three-point correlations produced vanish in direct detection experiments. On the other hand, we show that in scenarios where the B-mode of the cosmic microwave background is sourced by gravitational waves generated by a global phase transition, a strong three-point signal among the polarization modes is also produced. This may provide another method of distinguishing inflationary B-modes. To carry out this computation, we have developed a diagrammatic approach to the calculation of stochastic gravitational waves sourced by scalar fluids, which has applications beyond the present scenario.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An access alternative for mobile satellite networks

Conceptually, this paper discusses strategies of digital satellite communication networks for a very large number of low density traffic stations. These stations can be either aeronautical, land mobile, or maritime. The techniques can be applied to international, domestic, regional, and special purpose satellite networks. The applications can be commercial, scientific, military, emergency, navigational or educational. The key strategy is the use of a non-orthogonal access method, which tolerates overlapping signals. With n being either time or frequency partitions, and with a single overlapping signal allowed, a low cost mobile satellite system can be designed with n squared (n squared + n + 1) number of terminals.

Wu, W. W.↗

An Arbitrary Time Interval Generator Base on Vernier Clocks with 0.67 ps Adjustable Steps Implemented in FPGA

In TDC testing and timing system implementations, it is often necessary to generate signal pulses with finely adjustable time intervals. In delay cell–based schemes, the adjustment resolution is constrained by the propagation delay of the cells—typically 15–20 ps per step—and is sensitive to temperature and supply voltage variations. This document presents a fully digital approach that uses two vernier clocks, generated by two stages of cascaded phase-locked loops (PLLs) with a slight frequency difference, to achieve adjustable timing intervals through accumulated phase differences. The scheme was validated on two families of low-cost FPGA devices, achieving adjustable step sizes of 0.67 ps and 0.97 ps.

Wu, Jin-yuan [Fermilab] (ORCID:0000000344329521)↗

Flexible Data and Frame Synchronization Structure for the LunaNet PNT Signal

A LunaNet Lunar Augmented Navigation Service (LANS) is being developed to enable a position, navigation, and timing service for future Lunar operations. The signal includes two components. An in-phase data channel signal is spread by a 1.023 MCPS ranging code that provides a high-rate data message at 250 bps and is encoded by a strong Low Density Parity Check (LDPC) code. A pilot channel with a 5.115 MCPS spreading code is also provided. The pilot code is configured with a secondary (overlay) code that does not currently provide absolute time or frame Synchronization as is the case for L1C. This work shows the advantage of implementing an overlay structure that provides absolute time for the LunaNet LANS signal structure known as the Augmented Forward Signal (AFS). The LunaNet AFS structure was developed to service two classes of user receivers. The first class is a low-complexity user receiver that only receives the 1.023 MCPS signal and does not use the 5.115 MCPS pilot channel. For this class of user, a data frame Sync word is needed. The second class of receiver is a high-end receiver that can processes both data and pilot channels to take advantage of the higher chip rate pilot channel for enhanced robustness and improved accuracy. In the current draft LunaNet LANS AFS design, these users must employ the frame Sync word in the data channel and obtain absolute time after decoding the AFS navigation message. The signal structure would greatly benefit from the addition of a pilot overlay structure that provides absolute time and robust frame Sync for high-end users as done for L1C. To provide a more robust and interoperable AFS structure, this work summarizes a study and recommends alternatives for a new overlay code on the pilot channel that provides absolute time and a Sync word approach on the data channel. The overlay code and Sync word are designed to allow for flexible and robust data synchronization for both low- complexity and high-end user receivers. The new overlay code structure permits frame synchronization performance that is as good as or better than the L1 C signal, while enabling a determination of absolute time upon frame Sync to aid high-end assisted LANS AFS user receivers at low signal to noise levels. We also present the design of rate-matched 5G new radio (5GNR) LDPC codes that fit within the current 6000-symbol frame size along with a time of interval (TOI) word, frame ID (FID) word, and the remaining LunaNet AFS data message blocks. The paper describes and demonstrates robust frame Synchronization performance of the overlay code and Synch word approaches. The results are described in terms of probability of missed detection and probability of false alarm for a correct frame Synchronization at low Eb/No levels expected for decoding the TOI word and LDPC encoded data. Advantages of the proposed data Synchronization structure will be described along with use cases for low-end and high-end receivers. Practical implementation considerations will also be described.

LunaNet↗

First results of electron temperature measurements by the use of multi-pass Thomson scattering system in GAMMA 10

A multi-pass Thomson scattering (TS) has the advantage of enhancing scattered signals. We constructed a multi-pass TS system for a polarisation-based system and an image relaying system modelled on the GAMMA 10 TS system. We undertook Raman scattering experiments both for the multi-pass setting and for checking the optical components. Moreover, we applied the system to the electron temperature measurements in the GAMMA 10 plasma for the first time. The integrated scattering signal was magnified by approximately three times by using the multi-pass TS system with four passes. The electron temperature measurement accuracy is improved by using this multi-pass system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital communications study

Research is reported dealing with problems of digital data transmission and computer communications networks. The results of four individual studies are presented which include: (1) signal processing with finite state machines, (2) signal parameter estimation from discrete-time observations, (3) digital filtering for radar signal processing applications, and (4) multiple server queues where all servers are not identical.

Boorstyn, R. R.↗

Nonlinearity in rock - Evidence from earth tides

The earth is sinusoidally stressed by tidal forces; if the stress-strain relation for rock is nonlinear, energy should appear in an earth tide record at frequencies which are multiples of those of the larger tidal lines. An examination of the signals to be expected for different nonlinear deformation laws shows that for a nonlinear response without dissipation, the largest anomalous signal should occur at twice the forcing frequency, whereas for nonlinear laws involving dissipation (cusped hysteresis loops) the anomalous signal will be greatest at three times this frequency. The size of the signal in the dissipative case depends on the amount by which dissipation affects the particular response being measured. For measurements of strain tides this depends on whether dissipation is assumed to be present throughout the earth or localized around the point of measurement. An analysis of 5.7 years of strain tide records from Pinon Flat, California, shows a small signal at twice the frequency of the largest (M2) tide.

Agnew, D. C.↗

Tele-autonomous systems: New methods for projecting and coordinating intelligent action at a distance

There is a growing need for humans to perform complex remote operations and to extend the intelligence and experience of experts to distant applications. It is asserted that a blending of human intelligence, modern information technology, remote control, and intelligent autonomous systems is required, and have coined the term tele-autonomous technology, or tele-automation, for methods producing intelligent action at a distance. Tele-automation goes beyond autonomous control by blending in human intelligence. It goes beyond tele-operation by incorporating as much autonomy as possible and/or reasonable. A new approach is discussed for solving one of the fundamental problems facing tele-autonomous systems: The need to overcome time delays due to telemetry and signal propagation. New concepts are introduced called time and position clutches, that allow the time and position frames between the local user control and the remote device being controlled, to be desynchronized respectively. The design and implementation of these mechanisms are described in detail. It is demonstrated that these mechanisms lead to substantial telemanipulation performance improvements, including the result of improvements even in the absence of time delays. The new controls also yield a simple protocol for control handoffs of manipulation tasks between local operators and remote systems.

Conway, Lynn↗

Beam Test Results of the GlueX Forward Calorimeter

GlueX is an experiment to begin running in the near future at Jefferson Lab. Our research group is responsible for the forward calorimeter (FCAL) that is designed to measure the energy of photons produced from the decays of mesons. Recently, we conducted a beam test at Jefferson Lab using a prototype of the FCAL. Its goal was to experimentally verify the energy resolution of the FCAL as a function of beam energy. The prototype was tested with recoil electrons ranging in energy from 113MeV to 277MeV. We obtained the resolution by comparing the reconstructed energy to the known energy. In addition, we corrected our measured resolution for multiple scattering and energy loss based on a GEANT4 simulation of the prototype. Another important goal of the beam test was to measure the timing resolution of the channels on our flash analog to digital converters (fADCs). For GlueX, we need to require the timing resolution to be much less than the bunch spacing (2ns). The results of our studies indicate that the energy resolution of the FCAL is consistent with our predictions. We also found the timing resolution as a function of signal size and the results agreed with a similar study. For signals of about at least 75mV, the timing resolution achieved was significantly lower than 2ns.

Bauer, Kevin↗

Advanced Signal Processing Techniques Applied to Terahertz Inspections on Aerospace Foams

The space shuttle's external fuel tank is thermally insulated by the closed cell foams. However, natural voids composed of air and trapped gas are found as by-products when the foams are cured. Detection of foam voids and foam de-bonding is a formidable task owing to the small index of refraction contrast between foam and air (1.04:1). In the presence of a denser binding matrix agent that bonds two different foam materials, time-differentiation of filtered terahertz signals can be employed to magnify information prior to the main substrate reflections. In the absence of a matrix binder, de-convolution of the filtered time differential terahertz signals is performed to reduce the masking effects of antenna ringing. The goal is simply to increase probability of void detection through image enhancement and to determine the depth of the void.

Trinh, Long Buu↗