Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Catalytic Bio-crude Production in a Novel, Short-Contact Time Reactor

RTI has developed a catalytic fast pyrolysis (CFP) process to produce biomass-based hydrocarbon replacement fuels. From a technology perspective, this advanced biofuels process produces liquid transportation fuels that can leverage capital expenditures in the existing petroleum distribution infrastructure. From a business perspective, this technology does not face potential market limitations caused by oxygenate blend limitations for light duty vehicle applications. A promising catalyst has been developed with excellent potential for deoxygenation to produce a hydrocarbon-rich biocrude that is more suitable for upgrading with traditional hydroprocessing technology. The role of the catalyst is to control the chemistry during biomass pyrolysis to produce a biocrude in a single step that has lower oxygen content and is more thermally stable than conventional biomass fast pyrolysis oil. Catalyst properties are optimized to minimize gas and coke production and improve catalytic deoxygenation and biocrude yields. Results from this project have demonstrated that biocrudes from catalytic fast pyrolysis contain <20 wt% oxygen, with the organic fraction as low as 12% oxygen. These oxygen numbers are > 50% lower compared to traditional fast pyrolysis oils. The biocrude produced from our CFP process can be upgraded to gasoline range hydrocarbons. A very conservative approach for upgrading included a preliminary stabilization step followed by a hydroprocessing step. The oxygen content in the upgraded product was decreased by 97% (to less than 3wt %) from the oxygen content of the biocrude sample. Additionally, the acid content was reduced by 99% from the acid content of the biocrude sample. In an optimized integrated process, the CFP step and the hydroprocessing (upgrading) step need to be carefully balanced to maximize the input biomass energy that is recovered in the finished biofuels. Hydrogen utilization and carbon recovery during both catalytic biomass pyrolysis and biocrude upgrading need to be optimized to maximize energy recovery in the finished biofuel. A nominal 1 ton per day (TPD) catalytic biomass pyrolysis system was designed based on the laboratory experimental data. The system was designed to achieve the short residence times (0.5–2 sec) and high heat transfer rates required for maximum liquid biocrude yields while optimizing process integration to maintain catalyst activity by continuous regeneration. The catalytic biomass pyrolysis reactor is a continuously circulating single-loop transport reactor design that is flexible enough to allow sensitivity studies around temperature, residence time, biomass feed rate, and catalyst-to-biomass ratio (i.e., catalyst circulation rate) for process optimization. For a nominal 100 lb/hr feed rate of dry biomass, the products include ~25 lb/hr char and coke, ~20 lb/hr permanent gases, and ~55 lb/hr condensable vapors. Pyrolysis temperatures are 350–600°C, and the system is operated close to ambient pressure. Production of the catalyst developed within the project was scaled up to provide enough material (200kg) for bench-scale testing. The 1TPD bench-scale unit was fabricated, installed and commissioned with this project. Biocrude samples from wood were produced in this unit with the CFP catalyst with material balance > 90%. The intermediate biocrude yields and chemical composition compare well with previous laboratory results and a hydroprocessing strategy for upgrading the resulting biocrude was developed. The experimental results obtained within this project were used to develop a process model for a 2000 TPD commercial facility. Detailed flow sheets were developed for all major unit operations in the process and provided a basis for an economic analysis to develop capital and operating costs. Estimates of the biofuel production costs were used to develop internal rates of return for the yields and compositions measured for the current state of technology at the end of this project and for the yields anticipated for an optimized (nth plant) scenario as additional process improvements are made.

09 BIOMASS FUELS↗

CCE Case Study: Baltavia Substation Power Outage

In this case study, we will examine a fictional event broadly inspired by the real power outages in Ukraine that took place in December 2015 and December 2016—both the result of cyber-enabled sabotage. The actual events of 2015 and 2016 were well-documented—the adversaries in these attacks gained access to a few power companies’ corporate networks, pivoted to industrial control system (ICS) networks, and created widespread physical effects in the form of power outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Turbine Lightning Mitigation System Radar Cross Section Reduction

Modern wind turbines employ Lightning Mitigation Systems (LMSs) in order to reduce costly damages caused by lightning strikes. Lightning strikes on wind turbines occur frequently making LMS configurations a necessity. An LMS for a single turbine includes, among other equipment, cables running inside each blade, along the entire blade length. These cables are connected to various metallic receptors on the outside surface of the blades. The LMS cables can act as significant electromagnetic scatterers which may cause interference to radar systems. This interference may be mitigated by reducing the Radar Cross-Section (RCS) of the wind turbine's LMS. This report investigates proposed modifications to LMS cables in order to reduce the RCS when illuminated by Re locatable Over the Horizon Radar (ROTHR) systems which operate in the HF band (3 - 30 MHz). The proposed modifications include breaking up the LMS cables using spark gap connections, and changing the orientation of the LMS cable within the turbine blade. Both simulated analyses of such RCS mitigation techniques is provided as well as recommendations on further research.

17 WIND ENERGY↗

Robust Distributed State Estimator for Interconnected Transmission and Distribution Networks (Final Report RPPR-1)

This project’s objective is to develop a combined transmission and distribution state estimator which accounts for very large system size and model complexity (by way of distributing the computations) and large number of solar PV units connected to the distribution system on multiple feeders. The project not only provides a robust formulation and solution to this problem but also tests the solution by implementing it on a well-established large utility system. It introduces several improvements with respect to the state of the art in existing state estimation software: (a) The developed state estimator (SE) allows robust and accurate monitoring of bidirectional flows in distribution systems which result due to the distributed energy sources which are not observable and thus not incorporated in generation dispatch; (b) Large utility systems with tens of thousands of transmission buses and hundreds of thousands of distribution nodes are difficult to model as a single integrated system. This shortcoming is addressed by developing a “scalable distributed computational framework” which allows splitting the ultra large system models into several small subsystems and coordinating their solution by a robust and practical state estimation formulation; (c) Measurement errors irrespective of their locations are detected and removed by the developed state estimator. Historically, transmission and distribution systems were analyzed and operated as two independent systems. Given the non-transposed short feeder sections, unevenly loaded phases, strictly radial configuration and unidirectional power flows in the absence of remote generation, distribution system analysis was customized to account for these characteristics. However, some of these assumptions are no longer valid (non-radial configuration, bidirectional power flows) and thus distribution system analysis should be revisited. Furthermore, in the past, the interaction between the transmission and distribution systems was quite passive, where distribution substations were modeled as lumped loads in the transmission system model. With substantial generation injected by renewable generation located in the distribution systems, such modeling will no longer be accurate. The developed state estimator facilitates proper monitoring of the interactions between the transmission and distribution systems and enables smart dispatch of these units which are made observable by the state estimator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

Recommendations for Distributed Energy Resource Patching

While computer systems, software applications, and operational technology (OT)/Industrial Control System (ICS) devices are regularly updated through automated and manual processes, there are several unique challenges associated with distributed energy resource (DER) patching. Millions of DER devices from dozens of vendors have been deployed in home, corporate, and utility network environments that may or may not be internet-connected. These devices make up a growing portion of the electric power critical infrastructure system and are expected to operate for decades. During that operational period, it is anticipated that critical and noncritical firmware patches will be regularly created to improve DER functional capabilities or repair security deficiencies in the equipment. The SunSpec/Sandia DER Cybersecurity Workgroup created a Patching Subgroup to investigate appropriate recommendations for the DER patching, holding fortnightly meetings for more than nine months. The group focused on DER equipment, but the observations and recommendations contained in this report also apply to DERMS tools and other OT equipment used in the end-to-end DER communication environment. The group found there were many standards and guides that discuss firmware lifecycles, patch and asset management, and code-signing implementations, but did not singularly cover the needs of the DER industry. This report collates best practices from these standards organizations and establishes a set of best practices that may be used as a basis for future national or international patching guides or standards.

97 MATHEMATICS AND COMPUTING↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Enabling Technologies for a Pressurized Dry Feed Oxy-Coal Reactor

Researchers at Brigham Young University (3 faculty, 9 graduate students, and 35 undergraduate students) completed this 5-year research program with the main objective to build and test a 100 kWth pressurized dry-feed oxy-coal combustor (POC). This objective was achieved through the development and testing of a unique pressurized dry coal fluidization feed system that operates in conjunction with a pressurized oxycoal combustor. The project included a series of R&D tasks, including design, modeling, bench-scale testing, construction, safety reviews, and reactor testing which are detailed in this report. BYU researchers were supported in some modeling tasks by project partners Reaction Engineering International (REI) and CPFD Software.

01 COAL, LIGNITE, AND PEAT↗

An Analysis of PNM's Renewable Reserve Requirements to Meet New Mexico's Decarbonization Goals

Over the next three years, the Public Service Company of New Mexico (PNM) plans to increase utility-scale solar photovoltaic (PV) capacity from today’s roughly 330MW to about 1600MW. This massive increase in variable generation—from about 15% to 75% of peak load—will require changes in how PNM operates their system. We characterize the 5 and 30-minute solar and wind forecast errors that the system is likely to experience in order to determine the level of reserves needed to counteract such events. Our focus in this study is on negative forecast error (in other words, shortfalls relative to forecast) – whereas excess variable generation can be curtailed if needed, a shortfall must be compensated for to avoid loss of load. Calculating forecast error requires the use of the same forecasting methods that PNM uses or a reasonable approximation thereof. For wind, we use a persistence forecast on actual 5-minute 2019 wind output data (scaled up to reflect the amount of wind capacity planned for 2025). For solar, we use a formula incorporating the clear sky index (CSI) for the forecast. As the solar on the grid now is a small fraction of what is planned for 2025, we generated 5-minute solar data using 2019 weather inputs. We find that to handle 99.9% of the 5-minute negative forecast errors, a maximum of 275MW of variable generation reserve during daylight hours, and a maximum of 75MW during non-daylight hours, should be sufficient. Note that this variable generation reserve is an additional reserve category that specifies reserves over and above what are currently carried for contingency reserve. This would require a significant increase in reserve relative to what PNM currently carries or can call upon from other utilities per reserve sharing agreements. This variable generation reserve specification may overestimate the actual level needed to deal with PNM’s planned variable generation in 2025. The forecasting methodologies used in this study likely underperform PNM’s forecasting – and better forecasting allows for less reserve. To obtain more precise estimates, it is necessary to consider load and use the same forecasting inputs and methods used by PNM.

14 SOLAR ENERGY↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Herbaceous Feedstock 2021 State of Technology Report

The U.S. Department of Energy (DOE) promotes the production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the State of Technology (SOT). As part of its involvement with this mission, Idaho National Laboratory (INL) completes an annual SOT report for biomass feedstock logistics. This report summarizes supply system impacts of Bioenergy Technologies Office (BETO)-funded research and development efforts at INL and INL collaboration with external partners (e.g. Forest Concepts, Purdue University ) that lead to improvements in feedstock supply systems. These include improvements to and observed performance of innovative harvest and collection methods, storage technologies, transportation and handling approaches, and advanced preprocessing technologies. Biomass quality and variability, and the interface between feedstock quality and conversion performance are key drivers in addition to delivered feedstock cost. In this report, we estimate the benefits of R&D technology improvements to individual supply system unit operations and present the status of feedstock logistics technology development for converting herbaceous biomass into biofuels. These analyses are supported by experimental data where possible and help to align the SOT relative to the cost goals defined in the Multi-Year Plan.

09 BIOMASS FUELS↗

Communication System Modeling in Transactive Systems

Transactive energy systems almost always rely on communication systems for proper operation but most analysis of transactive systems do not model the communication system. Often these analysis are performed by those without a communication system modeling or simulation background and the difficulty of implementing such models in the analysis environment is prohibitive. Without this model, an understanding of the communication system requirements to successfully implement a transactive energy system can not be comprehended. This report details a capability of auto-generating communication system models from an electrical distribution system model, discusses the need for such models, discusses the method by which these models were developed in this project, and demonstrates the impact on the performance of a load management system when using such models. This capability has been incorporated into Pacific Northwest National Laboratory’s (PNNL) Transactive Energy Simulation Platform (TESP).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Case Study of Tunable White LED Lighting with Networked Lighting Controls (Emory University Cognitive Empowerment Program)

Emory University and Georgia Institute of Technology (Georgia Tech) partnered to create the Charlie and Harriet Schaffer Cognitive Empowerment Program (CEP) facility in northeast Atlanta. Together with the funders they are building a program to help individuals experiencing mild cognitive impairment (MCI) to maintain their physical and cognitive health, and independence as long as possible. In addition to applying effective strategies and therapies, the two research groups are investigating the responses of the MCI members to treatments that involve acoustical conditions, exercise and movement, and lighting changes that may support retention or relearning of skills. Care partners and family members receive support and instruction to improve home and work life, promoting joy, purpose, and wellness in the family groups. The lighting system uses tunable-white LEDs, employing luminaires with both warm and cool-color emitters that can be dimmed separately to produce any white correlated color temperature (CCT) between 2700 K and 6500 K. All luminaires were dimmable to achieve subdued or lively surroundings for different treatments, time-of-day, and mood. A central networked digital control system was employed to allow tuning of multiple spaces together (for example, bright, cool morning light could be programmed for extra stimulation, or lighting in all spaces at the end of the day could be reduced in both light output and CCT to promote relaxation and not interfere with the melatonin cycle of occupants). Almost all spaces were equipped with individual room control of dimming and color temperature with touch screens to allow users to tune the lighting as desired, but each room’s controls could also be specially programmed through the server in case the research staff were investigating lighting settings on learning, for example. The server incorporates a timeclock, and it is able to send signals to switch off all lighting after occupancy hours, or enable occupancy sensors to control the lighting. The bulk of the construction work was completed in January 2020. It was clear from an initial walk-through that although the lighting system produced the expected high light level with low-glare qualities of light, that there were issues and inconsistencies to be resolved. These were noted in an initial punchlist visit and expected to be resolved when the tech representatives from the agency visited with the electrical contractor in the following few weeks. What followed was 2.5 years of identifying unexpected lighting performance in terms of light output, color, scheduling, and occupancy. This report documents the issues encountered in the effort to get the lighting and controls systems to operate as intended. It concludes with guidance for design professionals and manufacturers to help avoid problematic complexity in future projects.

42 ENGINEERING↗

Institutional Framework of Variable Renewable Energy Forecasting in India

The share of variable renewable energy (VRE) in India is growing rapidly, with a national goal of reaching 50% capacity from non-fossil fuel generation by 2030. One implication of this growth is the need for improved VRE forecasting methods. For this reason, the Ministry of New and Renewable Energy (MNRE) in India commissioned this study with support from the United States Agency for International Development (USAID), the National Renewable Energy Laboratory (NREL) in the United States, and the National Institute of Wind Energy (NIWE) in India. The objective of this study was to review the existing institutional framework and suggest changes needed to support the plans for large-scale VRE integration in the country. To achieve that objective, the authors consulted local stakeholders about the status of VRE forecasting in India, reviewed existing studies, and examined VRE forecasting methods around the world to identify best practices. Based on those best practices, the study presents six potential approaches to improve the VRE forecasting framework in India. Approaches include incentivizing VRE forecast improvement and use of the most accurate VRE forecast, creating an institution that will optimize VRE forecasts while maintaining and ensuring access to necessary data for forecasting, implementing a review and certification process for VRE forecast providers, forecasting closer to dispatch time and allowing for more frequent forecast revisions, increasing the frequency of weather forecasts, and aggregating VRE forecasts at the point of interconnection.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Addressing Regulatory Burdens to Accessing Solar Among Municipal, Commercial and Institutional Customers Through Collaborative Partnerships (Final Technical Report)

The project focused on providing education to large energy customers, with a focus on local governments, to help them better understand and overcome barriers to solar energy adoption that currently exist (or could exist) in utility planning processes and/or within wholesale energy markets. The project team created accessible educational materials — ranging from reports to case studies to webinars — that could connect with stakeholders who rarely engage in these venues, have limited bandwidth to do so, and possess little previous knowledge of these issues. The project team focused on sharing lessons learned and best practices based on the experiences of other local governments and large energy users that have engaged on these issues, including the PJM Cities and Communities Coalition (PJMCCC). The project sought to better connect these customers and other stakeholders to deepen and expand opportunities for them to engage together on these issues, as well as build peer networks to facilitate the exchange of information. The project team held convenings of key partners — such as local governments, developers, regulators, utilities and large solar buyers — to discuss best practices, develop research products to broaden stakeholders’ knowledge base, and to foster these peer networks.

14 SOLAR ENERGY↗

Cyber100 Compass User Guide

This document provides an overview of the Cyber100 Compass tool and serves as a guide to users interested in understanding the cybersecurity risks facing their clean energy transition. The National Renewable Energy Laboratory (NREL) developed the Cyber100 Compass tool for cyber risk assessment at the system-of-systems level for system planners trying to reach high levels of renewables. Two offices of the U.S. Department of Energy (DOE) - the Office of Electricity and the Office of Cybersecurity, Energy Security, and Emergency Response-funded NREL to develop this framework that will enable grid system planners to understand and mitigate cybersecurity risk for grids transitioning to high levels of renewable generation, including 100%. Cyber100 Compass can help systems planners apply the principle of security-by-design at scale. Investing in an upfront understanding of system-of-systems (where the constituent systems are operating entities of the different renewable resources) risks from high-renewable grids will result in a more resilient grid at a lower long-term cost.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Entrainment and aerosol effects on marine boundary-layer clouds: An investigation using ACE-ENA data from HOLODEC, G1, Pico and ACTOS (Final Report on Project Activities)

Marine boundary-layer clouds cover large regions of the globe and are known to strongly influence radiative balances. The microphysical properties and persistence of these clouds are tightly coupled with cloud-top entrainment and aerosol properties within both the boundary layer and the overlying free troposphere. This work addressed the microphysical response to entrainment and aerosol properties in marine stratocumulus clouds, using data from the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) project. Specifically, emphasis was placed on 1. extensive in situ measurements taken with the Atmospheric Radiation Measurement (ARM) G1 aircraft using the Holographic Detector for Clouds (Holodec) instrument; 2. airborne measurements obtained with the helicopter-borne Airborne Cloud Turbulence Observation System (ACTOS) operated by the Leibniz Institute for Tropospheric Research (TROPOS) during the first phase of ACE-ENA; and 3. above-boundary-layer, mountain-top measurements taken at the Pico Mountain Observatory (OMP) by the research group of the co-investigator and scientists from TROPOS during the first phase of ACE-ENA. The work is aligned with the topic “Warm Boundary-Layer Atmospheric Processes.” Key results include the following. Data from the Holographic Detector for Clouds (Holodec) were reprocessed, refined, and validated through a careful instrument intercomparison, resulting in a high-quality dataset available on the ARM archive for ACE-ENA. High-resolution ACTOS measurements of thermodynamics, microphysical, and turbulence properties were analyzed to explore the behavior of the entrainment velocity at cloud top. Analysis of the vertical variability of cloud droplet size distribution shape suggests that mixing is more inhomogeneous near cloud top, and more homogeneous deeper into the cloud. Analysis of aerosol measurements from OMP explored the mixing state and cloud condensation nucleus properties, as well as the implications for radiative forcing. Finally, a machine learning algorithm was developed for identifying characteristic cloud droplet size distributions, and was employed to explore microphysical regimes in stratocumulus clouds observed during ACE-ENA. The characteristic size distributions are narrow, and only when spatially averaged do they produce the broad “gamma” distributions typically assumed in models. This implies that precipitation development should account for variability and correlations in the distribution shape as well as the number concentration of cloud droplets.

54 ENVIRONMENTAL SCIENCES↗