Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Supportability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Comparison of Bayesian network and support vector machine models for two-year survival prediction in lung cancer patients treated with radiotherapy

Purpose: Classic statistical and machine learning models such as support vector machines (SVMs) can be used to predict cancer outcome, but often only perform well if all the input variables are known, which is unlikely in the medical domain. Bayesian network (BN) models have a natural ability to reason under uncertainty and might handle missing data better. In this study, the authors hypothesize that a BN model can predict two-year survival in non-small cell lung cancer (NSCLC) patients as accurately as SVM, but will predict survival more accurately when data are missing. Methods: A BN and SVM model were trained on 322 inoperable NSCLC patients treated with radiotherapy from Maastricht and validated in three independent data sets of 35, 47, and 33 patients from Ghent, Leuven, and Toronto. Missing variables occurred in the data set with only 37, 28, and 24 patients having a complete data set. Results: The BN model structure and parameter learning identified gross tumor volume size, performance status, and number of positive lymph nodes on a PET as prognostic factors for two-year survival. When validated in the full validation set of Ghent, Leuven, and Toronto, the BN model had an AUC of 0.77, 0.72, and 0.70, respectively. A SVM model based on the same variables had an overall worse performance (AUC 0.71, 0.68, and 0.69) especially in the Ghent set, which had the highest percentage of missing the important GTV size data. When only patients with complete data sets were considered, the BN and SVM model performed more alike. Conclusions: Within the limitations of this study, the hypothesis is supported that BN models are better at handling missing data than SVM models and are therefore more suitable for the medical domain. Future works have to focus on improving the BN performance by including more patients, more variables, and more diversity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-206: A Comparison of Different Hardware Design Approaches for Feature-Supported Optical Head-Tracking with Respect to Angular Dependencies

Purpose: Recent research has shown that optical features significantly improve marker-less optical head-tracking for cranial radiotherapy. Simulations, however, showed that these optical features, which are used to derive tissue thickness, depend on the incident angle of the IR scanning laser beam and the perspective of the camera analyzing the reflective patterns. We present an experimental analysis determining which is the most robust optical setup concerning angular influences. Methods: In three consecutive experiments, the incident angle of the laser (1), the perspective of the camera (2) or both simultaneously (3, ‘inBeam’-perspective) were changed with respect to the target. We analyzed how this affects feature intensity. These intensities were determined from seven concentric regions of interest (ROIs) around the laser spot. Two targets were used: a tissue-like silicone phantom and a human's forehead. Results: For each experiment, the feature intensity generally decreases with increasing angle. We found that the optical properties of the silicone phantom do not fit the properties of human skin. Furthermore, the angular influence of the laser on the features is significantly higher than the perspective of the camera. With the ‘inBeam’- perspective, the smoothest decays of feature intensity were found. We suppose that this is because of a fixed relationship between both devices. This smoothness, suggesting a predictable functional relationship, may simplify angle compensation for machine learning algorithms. This is particularly prominent for the medial ROIs. The inner ROIs highly depend on the angle and power of the laser. The outer ROIs show less angular dependency but the signal strength is critically low and prone to artifacts. Therefore and because of the smooth decays, medial ROIs are a suitable tradeoff between susceptibility, signal-noise-ratio and distance to the center of the laser spot. Conclusion: For tissue thickness correlated feature acquisition, the medial ROIs with the ‘inBeam’-setup provide most valuable features This work was supported by Varian Medical Systems Inc. (Palo Alto, CA, USA). In addition, this work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-G-BRB-01: Topic Introduction: Do We Need Clinical Trials in Particle Therapy and How Can Medical Physics Support Them?

Proton therapy, in particular, and ion therapy, just beginning, are becoming an increasing focus of attention in clinical radiation oncology and medical physics. Both modalities have been criticized of lacking convincing evidence from randomized trials proving their efficacy, justifying the higher costs involved in these therapies. This session will provide an overview of the current status of clinical trials in proton therapy, including recent developments in ion therapy. As alluded to in the introductory talk by Dr. Schulte, opinions are diverging widely as to the usefulness and need for clinical trials in particle therapy and the challenge of equipoise. The lectures will highlight some of the challenges that surround clinical trials in particle therapy. One, presented by Dr. Choy from UT Southwestern, is that new technology and even different types of particles such as helium and carbon ions are introduced into this environment, increasing the phase space of clinical variables. The other is the issue of medical physics quality assurance with physical phantoms, presented by Mrs. Taylor from IROC Houston, which is more challenging because 3D and 4D image guidance and active delivery techniques are in relatively early stages of development. The role of digital phantoms in developing clinical treatment planning protocols and as a QA tool will also be highlighted by Dr. Lee from NCI. The symposium will be rounded off by a panel discussion among the Symposium speakers, arguing pro or con the need and readiness for clinical trials in proton and ion therapy. Learning Objectives: To get an update on the current status of clinical trials allowing or mandating proton therapy. Learn about the status of planned clinical trials in the U.S. and worldwide involving ion therapy. Discuss the challenges in the design and QA of clinical trials in particle therapy. Learn about existing and future physical and computational anthropomorphic phantoms for charged particle clinical trial development and support. Research reported in this presentation is supported by the National Cancer Institute of the National; Institutes of Health under Award Number P20CA183640.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation

Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone, or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH1L30CA199594-01.

60 APPLIED LIFE SCIENCES↗

High-level support for simulations in astro- and elementary particle physics

To fully exploit the potential of modern supereomputing systems, when performing particle and astrophysics simulations, the special user support unite called simulation laboratory “Elementary- and Astro-Particle Physics” (Sim-Lab E&A Particle) is established at Steinbuch Centre for Computing of the Karlsruhe Institute for Technology. SimLab is providing advanced support to scientific groups in developing the simulation software and porting them into up-to-date super-computing infrastructures. Some details of how the SimLab is governed and cooperation with developers and users of codes are presented in this work in progress paper including examples about code THiSMPI for simulation of particle accelerations in supernovae shock fronts and the KB3D code for solving quantum kinematic equations that could be used in simulations of heavy ion collisions or laser excited semiconductor systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experiences in extending parallware to support OpenACC. In: WACCPD '15 Proceedings of the Second Workshop on Accelerator Programming using Directives, Article No. 4

Porting scientific codes to accelerator-based computers using OpenACC and OpenMP is an important topic for the HPC community. Programmability, performance portability and developer productivity are key issues for the widespread use of these systems. In the scope of general-purpose parallel computing, Parallware is a new commercial OpenMP-enabling source-to-source compiler that automatically adds OpenMP capabilities in scientific programs. Thus, extending Parallware with OpenACC or OpenMP 4.x support would contribute to improve programmability and developer productivity. In contrast, the performance portability of such approach needs to be demonstrated in practice. This paper presents a preliminary study to extend Parallware with OpenACC support for GPU devices. A simple benchmark suite has been designed to mimic important features and computational patterns of real scientific applications. Handcoded OpenACC versions are compared to OpenMP versions automatically generated by Parallware. Performance is evaluated with the PGI OpenACC compiler on systems accelerated with NVIDIA GPUs.

Lobeiras, Jacobo↗

WIREFRAME: Supporting Data-dependent Parallelism through Dependency Graph Execution in GPUs

GPUs lack fundamental support for data-dependent parallelism and synchronization. While CUDA Dynamic Parallelism signals progress in this direction, many limitations and challenges still re-main. This paper introducesWireframe, a hardware-software solution that enables generalized support for data-dependent parallelism and synchronization. Wireframe enables applications to naturally express execution dependencies across different thread blocks through a dependency graph abstraction at run-time, which is sent to the GPU hardware at kernel launch. At run-time, the hardware enforces the dependencies specified in the dependency graph through a dependency-aware thread block scheduler. Overall, Wireframe is able to improve total execution time up to 65.20% with an average of 45.07%.

Abdolrashidi, AmirAli↗

Lowering and Runtime Support for Fortran’s Multi-Image Parallel Features using LLVM Flang, PRIF, and Caffeine

This paper provides an overview of the multi-image parallel features in Fortran 2023 and their implementation in the LLVM flang compiler and the Caffeine parallel runtime library. The features of interest support a Single-Program, Multiple-Data (SPMD) programming model based on executing multiple “images”, each of which is a program instance. The features also support a Partitioned Global Address Space (PGAS) in the form of “coarray” distributed data structures. The paper discusses the lowering of multi-image features to the Parallel Runtime Interface for Fortran (PRIF) and the implementation of PRIF in the Caffeine parallel runtime library. This paper also provides an early view into the design of a new multi-image dialect of the LLVM Multi-Level Intermediate Representation (MLIR). We describe validation and testing of the resulting software stack, and demonstrate that performance compares favorably to another open-source compiler and runtime library: GNU Compiler Collection (GCC) gfortran and OpenCoarrays, respectively.

Bonachea, Dan↗

Highly Dispersed Carbon Supported PdNiMo Core with Pt Monolayer Shell Electrocatalysts for Oxygen Reduction Reaction

The development of low-cost, durable, and high-performance materials that could substitute for the current platinum-based electrocatalysts would accelerate the commercialization of polymer electrolyte membrane fuel cells as an alternative power source. We report herein a new fabrication approach of carbon-supported platinum monolayer (ML) on ternary palladium-nickelmolybdenum core electrocatalysts (Pt ML /PdNiMo/C) by a sonochemical method using ionic liquid (IL) as a dispersion medium. The sonolysis technique can control the size and distribution of the ternary-metal nanoparticles on different carbon supports without addition of any external reducing agents, surfactants or capping agents. Depositing Pt MLs using under-potential deposition method on the ternary PdNiMo nanoparticle cores could enhance activity and durability of the cathode during the oxygen reduction reaction of the fuel cell. Herein, we show that the described sonolysis method produces more reliable and cost-effective electrocatalysts that outperforms a commercial Pt-based catalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Performance and Stability of the Cathode for Solid Oxide Fuel Cells IV. On the Ohmic loss in anode supported button cells with LSM or LSCF cathodes

Anode-supported solid oxide fuel cells (SOFC) with a variety of YSZ electrolyte thicknesses were fabricated by tape casting and lamination. The preparation of the YSZ electrolyte tapes with various thicknesses was accomplished by using doctor blades with different gaps between the precision machined, polished blade and the casting surface. The green tape was cut into discs, sintered at 1385°C for 2 h, and subsequently creep-flattened at 1350°C for 2 h. Either LSCF with an SDC interlayer or LSM+YSZ composite was used as the cathode material for the fuel cells. The ohmic resistances of these anode-supported fuel cells were characterized by electrochemical impedance spectroscopy at temperatures from 500°C to 750°C. A linear relationship was found between the ohmic resistance of the fuel cell and the YSZ electrolyte thickness at all the measuring temperatures for both LSCF and LSM+YSZ cathode fuel cells. The ionic conductivities of the YSZ electrolyte, derived for the fuel cells with LSM+YSZ or LSCF cathodes, were independent of the cathode material and cell configuration. The ionic conductivities of the YSZ electrolyte was slightly lower than that of the bulk material, possibly due to Ni-doping into the electrolyte. The fuel cell with a SDC interlayer and LSCF cathode showed larger intercept resistance than the fuel cell with LSM+YSZ cathode, which was possibly due to the imperfect contact between the SDC interlayer and the YSZ electrolyte and the migration of Zr into the SDC interlayer to form an insulating solid solution during cell fabrication. Calculations of the contribution of the YSZ electrolyte to the total ohmic resistance showed that YSZ was still a satisfactory electrolyte at temperatures above 650°C. Explorations should be directed to reduce the intercept resistance to achieve significant improvement in cell performance.

30 DIRECT ENERGY CONVERSION↗

Polarization Losses under Accelerated Stress Test Using Multiwalled Carbon Nanotube Supported Pt Catalyst in PEM Fuel Cells

The electrochemical behavior for Pt catalysts supported on multiwalled carbon nanotubes and Vulcan XC-72 in proton exchange membrane fuel cells under accelerated stress test was examined by cyclic voltammetry, electrochemical impedance spectroscopy, and polarization technique. Pt catalyst supported on multiwalled carbon nanotubes exhibited highly stable electrochemical surface area, oxygen reduction kinetics, and fuel cell performance at a highly oxidizing condition, indicating multiwalled carbon nanotubes show high corrosion resistance and strong interaction with Pt nanoparticles. The Tafel slope, ohmic resistances, and limiting current density determined were used to differentiate kinetic, ohmic, mass-transfer polarization losses from the actual polarization curve. Kinetic contribution to the total overpotential was larger throughout the stress test. However, the fraction of kinetic overpotential decreased and mass-transfer overpotential portion remained quite constant during accelerated stress test, whereas the fraction of ohmic overpotential primarily originating from severe proton transport limitation in the catalyst layer increased under the anodic potential hold.

30 DIRECT ENERGY CONVERSION↗

High Performance SrFe 0.2 Co 0.4 Mo 0.4 O 3–δ Ceramic Anode Supported Low-Temperature SOFCs

The development of alternative ceramic anodes for low-temperature solid oxide fuel cells (LT-SOFCs) is essential to overcome the inherent challenges such as redox instability and coking associated with Ni-based cermet anodes. Moreover, due to the large electrolyte ohmic loss at low temperature, it is critical to developing an electrode supported cell that allows electrolyte thickness reduction. Here we successfully demonstrated a high performance SrFe 0.2 Co 0.4 Mo 0.4 O 3–δ (SFCM) ceramic anode supported LT-SOFC with a peak power density of 730 mW cm –2 and 300 mW cm –2 at ambitious low temperatures of 550 °C and 450 °C, respectively, in humidified H 2 . The new anode material SFCM exhibits exceptional conductivity of over 30 S cm –1 at 450 °C in humidified H 2 , providing essential current collection capability as an anode backbone appropriate for the infiltration of Ni-gadolinia doped ceria (GDC) electrocatalysts. Compared to conventional Ni-cermet anodes, the nano-sized Ni-GDC particles in our SFCM based electrode significantly improves the cell stability in hydrocarbon gases. We demonstrated a stable long-term operation over a period of 380 h in CH 4 –containing gas mixtures at 450 °C with a voltage degradation rate of 4% per 1000 h at a constant current of 0.2 A*cm –2 . Furthermore, our results demonstrate a high performance ceramic anode with high stability for low temperature operation.

25 ENERGY STORAGE↗

Carbonaceous nanowire supports for polymer electrolyte membrane fuel cells

Here, carbohydrate-dye combinations were used to form ionically-linked soft templates for the formation of polypyrrole nanowire networks. High yields of nanostructured products were obtained using small amounts of low-cost carbohydrate and dye template materials, the majority of which remained encapsulated within the nanowires. Varying the concentration and the two-part ratio of the templates influenced the length and diameter of the nanofiber segments within the nanowire network. Pyrolysis of the nanowires yielded carbonaceous fibers containing nitrogen heteroatoms, as well as convoluted graphitic domains, well suited for supporting Pt nanoparticles. The resulting high density of nucleation sites enabled the formation of well dispersed, smaller Pt particles compared to commercial catalysts, despite significantly higher support surface loadings.

36 MATERIALS SCIENCE↗

Trilinos I/O Support (Trios)

Trilinos I/O Support (Trios) is a new capability area in Trilinos that serves two important roles: (1) it provides and supports I/O libraries used by in-production scientific codes; (2) it provides a research vehicle for the evaluation and distribution of new techniques to improve I/O on advanced platforms. This paper provides a brief overview of the production-grade I/O libraries in Trios as well as some of the ongoing research efforts that contribute to the experimental libraries in Trios.

Oldfield, Ron A.↗

EPICS Support For Beckhoff EK9000

This is a device support module for the EK9000, which couples EtherCAT terminals (specifically the ELXXXX terminals from Beckhoff) to a modbus network. Because it uses modbus, it's runnable on any IOC without needing a kernel module or other support software.

L., Jeremy↗

nvidia dataframe library patch to support parquet indexing

On behalf of our WFO sponsors/collaborators, we are working closely with NVIDIA to improve their public, open-source GPU dataframes library. We are improving the library's support for reading and writing Parquet (an open source file format) for general-purpose cloud storage and processing. This patch better supports the indexing found in the more recent Parquet specifications. Is there

Seidl, EdwardT↗

Qthreads Support for MPICH

SAND2024-00944O Qthread Support for MPICH is software that provides additions needed to enable the use of the Qthreads library. The high-performance message passing interface (MPICH) is an open-source implementation of MPI mainly developed and distributed by Argonne National Laboratory. Qthreads is a lightweight, user-level threading library developed and distributed by Sandia National Laboratories. MPICH currently supports Posix threads, Windows threads, and Argobots. This software enables parallel programs built with the MPICH implementation of MPI to use Qthreads user-level threads rather than Posix system-level threads. The software uses existing infrastructure in MPICH to interface to the Qthreads library. The existing interfaces in MPICH allow for creating, destroying, and managing the execution of multiple threads within a process and this software translates these calls to the equivalent Qthreads library functions. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Ciesko, Jan↗

Irrigation Modernization Decision Support Engine

Irrigation systems are some of the oldest existing infrastructure in the United States. Increasing demands on water resources in combination with the age of these systems has resulted in a need to invest in the modernization of irrigation systems. Modernization activities are difficult to quantify, requiring expertise across multiple different domain areas. Traditionally, the scoping of a modernization project takes several years and requires significant financial investment before the potential of the project can be determined. The Irrigation Modernization Decision Support Engine allows a user to build out different scenarios. These scenarios allow for a course estimation of a project’s potential and the associated costs and benefits of pursuing the scenario. The design of the Decision Support Engine also allows for the easy sharing between different stakeholders, allowing for increased communication and understanding.

Elliott, ShilohN.↗