Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Standards Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Graphene oxide overprints for flexible and transparent electronics

The overprints produced in inkjet technology with graphene oxide dispersion are presented. The graphene oxide ink is developed to be fully compatible with standard industrial printers and polyester substrates. Post-printing chemical reduction procedure is proposed, which leads to the restoration of electrical conductivity without destroying the substrate. The presented results show the outstanding potential of graphene oxide for rapid and cost efficient commercial implementation to production of flexible electronics. Properties of graphene-based electrodes are characterized on the macro- and nano-scale. The observed nano-scale inhomogeneity of overprints' conductivity is found to be essential in the field of future industrial applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of low angle grain boundaries in lightly deformed superconducting niobium and their influence on hydride distribution and flux perturbation

This study shows that low angle grain boundaries (LAGBs) can be created by small 5% strains in high purity (RRR ≥ 200) SRF-grade single crystalline niobium (Nb) and that these boundaries act as hydrogen traps as indicated by the distribution of niobium hydrides (Nb 1-x H x ). Nb 1-x H x is detrimental to superconducting radio frequency (SRF) Nb cavities due to its normal conducting properties at cavity operating temperatures. By designing a single crystal tensile sample extracted from a large grain (>5 cm) Nb ingot slice for preferred slip on one slip plane, LAGBs and dense dislocation boundaries developed. With chemical surface treatments following standard SRF cavity fabrication practice, Nb1-xHx phases were densely precipitated at the LAGBs upon cryogenic cooling (8-10 K/min). Micro-crystallographic analysis confirmed heterogeneous hydride precipitation, which included significant hydrogen atom accumulation in LAGBs. Magneto-optical imaging (MOI) analysis showed that these sites can then act as sites for both premature flux penetration and eventually flux trapping. However, this hydrogen related degradation at LAGBs did not completely disappear even after a 800 °C/2hrs anneal typically used for hydrogen removal in SRF Nb cavities. These findings suggest that hydride precipitation at a LAGB is facilitated by a non-equilibrium concentration of vacancy-hydrogen (H) complexes aided by mechanical deformation and the hydride phase interferes with the recovery process under 800°C annealing.

36 MATERIALS SCIENCE↗

Raman − Ramsey pulsed excitation of coherent population trapping resonances in a {sup 87}Rb cell with a buffer gas

We report the results of experimental investigation of the Raman – Ramsey method of pulsed excitation of coherent population trapping (CPT) resonances in a rubidium vapour cell filled with a mixture of Ar and Ne buffer gases. For the development of compact quantum microwave frequency standards, this method is an alternative to the pulsed optical pumping method recently implemented using the same rubidium cell. Both methods have advantages over the traditional double radio-optical resonance technique, the main of which is the substantial suppression of the light shift of the clock transition frequency, since the evolution of the coherence of atomic states forming the clock transition occurs in the absence of laser radiation in the cell. The narrow (110 – 240 Hz) Raman – Ramsey resonances are obtained using the scheme of pulsed excitation of CPT resonances on the D{sub 1} lines of the {sup 87}Rb atom with the same linear (lin||lin) polarisations of the bichromatic laser radiation components. The process of optimising the central fringe linewidth, its contrast, and the linewidth-to-contrast ratio is described. The magnetic dependence of the Raman – Ramsey line central fringe linewidth is experimentally investigated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photospheric magnitude diagrams for type II supernovat: A promising tool to compute distances

We develop an empirical color-based standardization for Type II supernovae (SNe II), equivalent to the classical surface brightness method given in Wesselink. We calibrate this standardization using SNe II with host galaxy distances measured using Cepheids, and a well-constrained shock breakout epoch and extinction due to the host galaxy. We estimate the reddening with an analysis of the B – V versus V – I color-color curves, similar to that of Natali et al. With four SNe II meeting the above requirements, we build a photospheric magnitude versus color diagram (similar to an H-R diagram) with a dispersion of 0.29 mag. We also show that when using time since shock breakout instead of color as the independent variable, the same standardization gives a dispersion of 0.09 mag. Moreover, we show that the above time-based standardization corresponds to the generalization of the standardized candle method of Hamuy and Pinto for various epochs throughout the photospheric phase. To test the new tool, we construct Hubble diagrams for different subsamples of 50 low-redshift (cz < 10{sup 4} km s{sup –1}) SNe II. For 13 SNe within the Hubble flow (cz {sub CMB} > 3000 km s{sup –1}) and with a well-constrained shock breakout epoch we obtain values of 68-69 km s{sup –1} Mpc{sup –1} for the Hubble constant and a mean intrinsic scatter of 0.12 mag or 6% in relative distances.

79 ASTRONOMY AND ASTROPHYSICS↗

STRONG GRAVITATIONAL LENS MODELING WITH SPATIALLY VARIANT POINT-SPREAD FUNCTIONS

Astronomical instruments generally possess spatially variant point-spread functions, which determine the amount by which an image pixel is blurred as a function of position. Several techniques have been devised to handle this variability in the context of the standard image deconvolution problem. We have developed an iterative gravitational lens modeling code called Mirage that determines the parameters of pixelated source intensity distributions for a given lens model. We are able to include the effects of spatially variant point-spread functions using the iterative procedures in this lensing code. In this paper, we discuss the methods to include spatially variant blurring effects and test the results of the algorithm in the context of gravitational lens modeling problems.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic shear power spectra in practice

Cosmic shear is one of the most powerful probes of Dark Energy, targeted by several current and future galaxy surveys. Lensing shear, however, is only sampled at the positions of galaxies with measured shapes in the catalog, making its associated sky window function one of the most complicated amongst all projected cosmological probes of inhomogeneities, as well as giving rise to inhomogeneous noise. Partly for this reason, cosmic shear analyses have been mostly carried out in real-space, making use of correlation functions, as opposed to Fourier-space power spectra. Since the use of power spectra can yield complementary information and has numerical advantages over real-space pipelines, it is important to develop a complete formalism describing the standard unbiased power spectrum estimators as well as their associated uncertainties. Building on previous work, this paper contains a study of the main complications associated with estimating and interpreting shear power spectra, and presents fast and accurate methods to estimate two key quantities needed for their practical usage: the noise bias and the Gaussian covariance matrix, fully accounting for survey geometry, with some of these results also applicable to other cosmological probes. Here, we demonstrate the performance of these methods by applying them to the latest public data releases of the Hyper Suprime-Cam and the Dark Energy Survey collaborations, quantifying the presence of systematics in our measurements and the validity of the covariance matrix estimate. We make the resulting power spectra, covariance matrices, null tests and all associated data necessary for a full cosmological analysis publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of semi-analytical, semi-empirical covariance matrices for two-point correlation function for early DESI data

ABSTRACT We present an extended validation of semi-analytical, semi-empirical covariance matrices for the two-point correlation function (2PCF) on simulated catalogs representative of luminous red galaxies (LRGs) data collected during the initial 2 months of operations of the Stage-IV ground-based Dark Energy Spectroscopic Instrument (DESI). We run the pipeline on multiple effective Zel’dovich (EZ) mock galaxy catalogs with the corresponding cuts applied and compare the results with the mock sample covariance to assess the accuracy and its fluctuations. We propose an extension of the previously developed formalism for catalogs processed with standard reconstruction algorithms. We consider methods for comparing covariance matrices in detail, highlighting their interpretation and statistical properties caused by sample variance, in particular, non-trivial expectation values of certain metrics even when the external covariance estimate is perfect. With improved mocks and validation techniques, we confirm a good agreement between our predictions and sample covariance. This allows one to generate covariance matrices for comparable data sets without the need to create numerous mock galaxy catalogs with matching clustering, only requiring 2PCF measurements from the data itself. The code used in this paper is publicly available at https://github.com/oliverphilcox/RascalC.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensor-Assisted Fault Mitigation in Quantum Computation

We propose a method for assisting fault mitigation in quantum computation through the use of sensors, co-located near physical qubits. Specifically, we consider using transition edge sensors co-located on silicon substrates hosting superconducting qubits to monitor for energy injection from ionizing radiation that has been demonstrated to increase decoherence in transmon qubits. We generalize from these two physical device concepts and explore the potential advantages of co-located sensors to assist fault mitigation in quantum computation. In the simplest scheme, co-located sensors beneficially assist rejection of calculations potentially affected by environmental disturbances. Investigating the potential computational advantage further required development of an extension to the standard formulation of quantum error correction. In a specific case the standard three-qubit, bit flip quantum correction code, we show that given a 20% overall error probability per qubit, approximately 90% of repeated calculation attempts are correctable. However, when sensor-detectable errors account for 45% of overall error probability, the use of colocated sensors uniquely associated with independent qubits, boosts the fraction of correct final-state calculations to 96% at the cost of rejecting 7% of repeated calculation attempts.

Orrell, John L.↗

Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber

Here, we measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF 3 I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6±0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble-nucleation theory. Moreover, this measurement confirms the applicability of CF 3 I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing Neutron Correlations through Nuclear Breakup

The effect of initial correlations between nucleons on the nuclear breakup mechanism is studied. A quantum transport theory which extends the standard mean-field approach is developed to incorporate short range pairing correlation as well as direct nucleon-nucleon collisions. A time evolution of the nuclear breakup from a correlated system leading to the emission of two particles to the continuum is performed. We show that initial correlations have strong influence on relative angles between particles emitted in coincidence. The present qualitative study indicates that nuclear breakup might be a tool to infer the residual interaction between nucleons in the nuclear medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multicode benchmark on simulated Ti K-edge x-ray absorption spectra of Ti-O compounds

X-ray absorption spectroscopy (XAS) is an element-specific materials characterization technique that is sensitive to structural and electronic properties. First-principles simulated XAS has been widely used as a powerful tool to interpret experimental spectra and draw physical insights. Recently, there has also been growing interest in building computational XAS databases to enable data analytics and machine learning applications. However, there are non-trivial differences among commonly used XAS simulation codes, both in underlying theoretical formalism and in technical implementation. Reliable and reproducible computational XAS databases require systematic benchmark studies. In this work, we benchmarked Ti K-edge XAS simulations of ten representative Ti-O binary compounds, which we refer to as the Ti-O-10 dataset, using three state-of-the-art codes: XSPECTRA, OCEAN and exciting. We systematically studied the convergence behavior with respect to the input parameters and developed a workflow to automate and standardize the calculations to ensure converged spectra. Our benchmark comparison considers a 35 eV spectral range starting from the K-edge onset, representative of widely used near-edge spectra. Quantitative comparison over this range is based on Spearman’s rank correlation score (r sp ). Our results show: (1) the two Bethe-Salpeter equation (BSE) codes (OCEAN and exciting) have excellent agreement with an average $r$ $sp$ of 0.998; (2) good agreement is obtained between the core-hole potential code (XSPECTRA) and BSE codes (OCEAN and exciting) with an average $r$ $sp$ of 0.990, and this smaller $r$ $sp$ reflects the noticeable differences in the main edge spectral shape that can be primarily attributed to the difference in the strength of the screened core-hole potential; (3) simulations from both methods overall reproduce well the main experimental spectral features of rutile and anatase, and the different treatments of the screened core-hole potential have visible impact on pre-edge intensities and the peak ratio of the main edge; (4) there exist moderate differences in the relative edge alignment of the three codes with a standard deviation of about 0.2 eV, which arise from multiple contributions including the frozen core approximation, final state effects, and different approximations used for the self-energy correction. In conclusion, our benchmark study provides important standards for first-principles XAS simulations with broad impact in data-driven XAS analysis.

36 MATERIALS SCIENCE↗

An Application for Validation of Power Distribution System Models in an ADMS Environment

An accurate model of a power distribution system is the foundation for model-based applications that ensure efficient and reliable grid operation in an advanced distribution management system (ADMS) environment. However, these models are error-prone and comprehensive model validation is challenging due to lack of standards-based systems, data originating from disparate databases and other sources, and the constantly evolving nature of modern power distribution systems. In this paper, a novel framework for comprehensive model validation is described. The proposed application, the Model Validator, ensures that a model is both consistent and feasible by validating the derivative static and operational network model. A modular architecture for the application has been implemented and integrated with an open-source standards-based platform for ADMS application development, GridAPPS-D, allowing new validation capability to be added with minimal time and effort. The Model Validator application is demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test cases over three validation scenarios.

Poudel, Shiva↗

The PetscSF Scalable Communication Layer

PetscSF, the communication component of the Portable, Extensible Toolkit for Scientific Computation (PETSc), is designed to provide PETSc's communication infrastructure suitable for exascale computers that utilize GPUs and other accelerators. PetscSF provides a simple application programming interface (API) for managing common communication patterns in scientific computations by using a star-forest graph representation. PetscSF supports several implementations based on MPI and NVSHMEM, whose selection is based on the characteristics of the application or the target architecture. An efficient and portable model for network and intra-node communication is essential for implementing large-scale applications. The Message Passing Interface, which has been the de facto standard for distributed memory systems, has developed into a large complex API that does not yet provide high performance on the emerging heterogeneous CPU-GPU-based exascale systems. Here, we discuss the design of PetscSF, how it can overcome some difficulties of working directly with MPI on GPUs, and we demonstrate its performance, scalability, and novel features.

97 MATHEMATICS AND COMPUTING↗

Quantification of organ motion based on an adaptive image-based scale invariant feature method

Purpose: The availability of corresponding landmarks in IGRT image series allows quantifying the inter and intrafractional motion of internal organs. In this study, an approach for the automatic localization of anatomical landmarks is presented, with the aim of describing the nonrigid motion of anatomo-pathological structures in radiotherapy treatments according to local image contrast.Methods: An adaptive scale invariant feature transform (SIFT) was developed from the integration of a standard 3D SIFT approach with a local image-based contrast definition. The robustness and invariance of the proposed method to shape-preserving and deformable transforms were analyzed in a CT phantom study. The application of contrast transforms to the phantom images was also tested, in order to verify the variation of the local adaptive measure in relation to the modification of image contrast. The method was also applied to a lung 4D CT dataset, relying on manual feature identification by an expert user as ground truth. The 3D residual distance between matches obtained in adaptive-SIFT was then computed to verify the internal motion quantification with respect to the expert user. Extracted corresponding features in the lungs were used as regularization landmarks in a multistage deformable image registration (DIR) mapping the inhale vs exhale phase. The residual distances between the warped manual landmarks and their reference position in the inhale phase were evaluated, in order to provide a quantitative indication of the registration performed with the three different point sets.Results: The phantom study confirmed the method invariance and robustness properties to shape-preserving and deformable transforms, showing residual matching errors below the voxel dimension. The adapted SIFT algorithm on the 4D CT dataset provided automated and accurate motion detection of peak to peak breathing motion. The proposed method resulted in reduced residual errors with respect to standard SIFT, providing a motion description comparable to expert manual identification, as confirmed by DIR.Conclusions: The application of the method to a 4D lung CT patient dataset demonstrated adaptive-SIFT potential as an automatic tool to detect landmarks for DIR regularization and internal motion quantification. Future works should include the optimization of the computational cost and the application of the method to other anatomical sites and image modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment. A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document or procedure into clinical use, associated risks can be identified and mitigated before patient care and clinical workflow are impacted.

60 APPLIED LIFE SCIENCES↗

SU-G-206-05: A Comparison of Head Phantoms Used for Dose Determination in Imaging Procedures

Purpose: To determine similarities and differences between various head phantoms that might be used for dose measurements in diagnostic imaging procedures. Methods: We chose four frequently used anthropomorphic head phantoms (SK-150, PBU-50, RS-240T and Alderson Rando), a computational patient phantom (Zubal) and the CTDI head phantom for comparison in our study. We did a CT scan of the head phantoms using the same protocol and compared their dimensions and CT numbers. The scan data was used to calculate dose values for each of the phantoms using EGSnrc Monte Carlo software. An .egsphant file was constructed to describe these phantoms using a Visual C++ program for DOSXYZnrc/EGSnrc simulation. The lens dose was calculated for a simulated CBCT scan using DOSXYZnrc/EGSnrc and the calculated doses were validated with measurements using Gafchromic film and an ionization chamber. Similar calculations and measurements were made for PA radiography to investigate the attenuation and backscatter differences between these phantoms. We used the Zubal phantom as the standard for comparison since it was developed based on a CT scan of a patient. Results: The lens dose for the Alderson Rando phantom is around 9% different than the Zubal phantom, while the lens dose for the PBU-50 phantom was about 50% higher, possibly because its skull thickness and the density of bone and soft tissue are lower than anthropometric values. The lens dose for the CTDI phantom is about 500% higher because of its totally different structure. The entrance dose profiles are similar for the five anthropomorphic phantoms, while that for the CTDI phantom was distinctly different. Conclusion: The CTDI and PBU-50 head phantoms have substantially larger lens dose estimates in CBCT. The other four head phantoms have similar entrance dose with backscatter hence should be preferred for dose measurement in imaging procedures of the head. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-05: New Dosimetry Methods for CBCT

Purpose: To determine the absorbed dose to water in the moderately filtered (M-series) x-ray beams at the UWADCL and assess the feasibility of transferring this dose to water to a clinical CBCT environment. Methods: The dose was determined in the M-series beams using three dosimetry Methods: the TG-61 protocol, a {sup 60}Co absorbed dose to water calibration, and through the use of a Monte Carlo (MC) model of the x-ray tube. The dose to water in the M-series beams determined by the MC model was used to calibrate an ionization chamber. The calibrated chamber was used to measure the dose to water from a Varian CBCT system. The dose from the CBCT beams was also measured using the same methods as for the M-series beams. Results: The measured surface doses in the M-series beams determined by MC method and TG-61 agreed within 3% for all beams. The dose to water a depth of 2 cm in the M-series beams as determined by the TG-61, {sup 60}Co, and MC methods, agreed within 2%. The dose in the CBCT beams was determined using the same methods as for the M-series beams and using the newly determined x-ray dose to water calibration coefficient. At the phantom surface, the dose values agreed within 1.5% and at a 2 cm depth the values agreed within 3%. Conclusion: New techniques to determine the absorbed dose to water in standard x-ray beams were developed. The dose values were in good agreement with previous techniques, but with much lower uncertainties. The dose to water in the M-series beams was used to calibrate an ionization chamber and the dose in the CBCT beams was measured using this calibration. The CBCT dose at a depth of 2 cm was measured in this manner and it agreed with other dose determination methods.

60 APPLIED LIFE SCIENCES↗

QCD analysis of DIS and SIDIS data

The combined analysis of polarized DIS and SIDIS data is performed in NLO QCD using two alternative procedures: standard fitting procedure and the recently developed direct new method. The results from two methods are compared. The especial attention is paid to the light sea and strange PDFs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗